• Title/Summary/Keyword: Speed change

Search Result 3,185, Processing Time 0.039 seconds

A Study on Construction of Express Lane Applied by Bus Only Lane as Seperation Facility: Focused on Pangyo-Hannam Section of Gyeongbu Expressway (버스전용차로를 분리시설로 활용한 Express Lane 구축에 관한 연구: 경부고속도로 판교-한남 구간을 중심으로)

  • Kim, Min Kyoung;Kim, Ju Hyun;Shin, Eon Kyo
    • Journal of Korean Society of Transportation
    • /
    • v.31 no.4
    • /
    • pp.32-46
    • /
    • 2013
  • Because of short length between interchanges, traffic congestion has been caused by a lot of short trip traffic in the urban section of interregional expressway. Also, in case of expressway with Bus Only Lane, bus causes dangerous situation by conflicting between vehicles and buses in order to access from Bus Only Lane to IC. Therefore, this study aims to propose Express Lane applied by Bus Only Lane as a new lane operation in order to efficiently operate and to analyze the effectiveness on constructing Express Lane to the Pangyo-Hannam section in Gyeongbu Expressway. The study analyzes effectiveness by scenario using the micro traffic simulation tool, VISSIM 5.4. For this, the indicators which evaluate construction effect of Express Lane, are used by average delay time, average speed and total travel time. The results of the study showed the best effectiveness when Express Lane installed one, and it represented an ideal traffic condition when long distance trip traffic of the whole traffic is 25% in the study section. Therefore, the construction of Express Lane using Bus Only Lane achieves positive effectiveness on safety and expense aspect as well as uncongested flow.

The Experimental Study of Various Salts on the Characteristics of Heat Transfer in Indirect Moxibustion with Salt (염(鹽)의 종류(種類)에 따른 격염구(隔鹽灸)의 열전달(熱傳達) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Lee, Geon-mok;Lee, Gun-hyee;Seo, Eun-mi
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.119-135
    • /
    • 2004
  • Objective: The purpose of this study is to investigate the mechanism and effect of moxibustion with salt objectively, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxibustion with salt. Methods: We have selected of the moxibustion with salt of indirect moxibustion. We make a comparative study of the thermodynamic characteristics of moxibustion with salt as a kind of the 4 salt. We examined combustion times, temperatures, temperature gradients in each period during a combustion of moxa. Results: 1. We make out that it is not significantly change the time of thermal conduction of moxibustion with salt as a kind of 4 salt. 2. The heating period of Refined Salt was long and that of Sun-dried Salt was a short time respectively. The heating period of maximum tamperature is high Sun-dried Salt, Mechanical Salt and Refined Salt orderly. Maximun heating speed in the heating period was $0.151{\sim}0.184^{\circ}C/sec$ and at the same tendency of the maximum temperature in the heating period. 3. The retaining period was shorter than the heating period respectively, that is 15~24% of the combustion time of in the heating period. We make out that it is not significantly different the time of the retaining period as a kind of 4 salt. The mean temperature of retaining period was $43.2{\sim}48.1^{\circ}C$, that was extraordinarily high temperature. 4. We make out that it is not significantly different the time of the cooling period as a kind of 4 salt. The cooling period was measured 223~233sec. Beacuse the same density and size of moxa combustion was made an experiment. 5. The effective combustion time of Refined Salt is longer(259sec) than that of Sun-dried Salt(173sec). It is significantly different the time of the combustion time as a kind of 4 salt. 6. It is significantly different the Sample deviation of the combustion time as a kind of 4 salt because of the water content of the 4 salt individually. Conclusions: As the base on this study, we obtained the conclusion as the follows. The salt of moxibustion with salt was fitted for Sun-dried Salt due to making to Mechanical Salt recently. The Refined Salt is composition rate to another and small size comparatively. So It was fitted for the salt of moxibustion with salt. It is necessary to study continuously about the more suitable moxibustion with salt and quantitative analysis about the moxibustion with salt.

  • PDF

A Determination Model of the Data Transmission-Interval for Collecting Vehicular Information at WAVE-technology driven Highway by Simulation Method (모의실험을 이용한 WAVE기반 고속도로 차량정보 전송간격 결정 모델 연구)

  • Jang, Jeong-Ah;Cho, Han-Byeog;Kim, Hyon-Suk
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.4
    • /
    • pp.1-12
    • /
    • 2010
  • This paper deals with the transmission interval of vehicle data in smart highway where WAVE (Wireless Access for Vehicular Environments) systems have been installed for advanced road infrastructure. The vehicle data could be collected at every second, which is containing location information of the vehicle as well the vehicle speed, RPM, fuel consuming and safety data. The safety data such as DTC code, can be collected through OBD-II. These vehicle data can be used for valuable contents for processing and providing traffic information. In this paper, we propose a model to decide the collection interval of vehicle information in real time environment. This model can change the transmission interval along with special and time-variant traffic condition based on the 32 scenarios using microscopic traffic simulator, VISSIM. We have reviewed the transmission interval, communication transmission quantity and communication interval, tried to confirm about communication possibility and BPS, etc for each scenario. As results, in 2-lane from 1km highway segment, most appropriate transmission interval is 2 times over spatial basic segment considering to communication specification. In the future, if a variety of wireless technologies on the road is introduced, this paper considering not only traffic condition but also wireless network specification will be utilized the high value.

Division of Homogeneous Road Sections for National Highway by Genetic Algorithms (유전자 알고리즘을 적용한 국도의 동질성 구간 분할)

  • Oh, Ju-Sam;Lim, Sung-Han;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.41-47
    • /
    • 2005
  • Traffic data such as traffic volume, speed, and vehicle Class are very important basic data for the plan and design of highway. Based on traffic data, the future service level of a specific highway and geometry of newly constructed or expended road is predicted and determined. The Ministry of Construction & Transportation has simultaneously surveyed coverage count and permanent count at highways since 1985. Traffic volume survey sections were determined at jointed nodes of highways and jointed nodes of highways and other roads such as freeway and local highway. Volume survey was performed at these sections. The premise to decide these sections is assumed that links between jointed nodes of main highways exhibit similar traffic characteristics. Recently, due to the change of highway geometries such as construction of detour road and installations of traffic facilities such as installation of media, traffic characteristics of the existing traffic volume survey sections was changed. To reflect these changes, traffic characteristics at homogeneous road sections was widely evaluated and analyzed. Using Genetic Algorithms, a model was developed for the evaluation of traffic characteristics at homogeneous road sections. Traffic volume survey sections were then determined through the application of the developed model for current traffic system.

  • PDF

Effects of Various Acid Etching Methods on the Shear Bond Strength between Iithium Disilicate Ceramic and Composite Resin (다양한 산처리 방법이 lithium Disilicate 도재와 복합레진간의 전단결합강도에 미치는 영향)

  • Kang, Dae-Hyun;Bok, Won-Mi;Song, Jin-Won;Song, Kwang-Yeob;Ahn, Seung-Ggeun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.2
    • /
    • pp.149-159
    • /
    • 2006
  • Statement of problem. Porcelain repair mainly involves replacement with composite resin, but the bond strength between composite resin and all-ceramic coping materials has not been studies extensively. Purpose. The objective of this study was to investigate the influence of composite resin and ceramic etching pattern on shear bond strength of Empress2 ceramic and observe the change of microstructure of ceramic according to etching methods. Material and methods. Eighty-five cylinder shape ceramic specimens (diameter 5mm, IPS Empress 2 core materials) embeded by acrylic resin were used for this study. The ceramic were specimens divided into sixteen experimental groups with 5 specimens in each group and were etched with phosphoric acid(37%, 65%) & hydrofluoric acid (4%, 9%) according to different etching times(30s, 60s, 120s 180s). All etched ceramic surfaces were examined morphologically using SEM(scanning electron microscopy). Etched surfaces of ceramic specimens were coated with silane (Monobond-S) & adhesive(Heliobond) and built up composite resin using Teflon mold. Accomplished specimens were tested under shear loading until fracture on universal testing machine at a crosshead speed 1mm/min; the maximum load at fracture(kg) was recorded. Shear bond strength data were analyzed with one way ANOVA and Duncan tests.(P<.05) Results. Maximum shear bond strength was $30.07{\pm}2.41(kg)$ when the ceramic was etched with 4% hydrofluoric acid at 120s. No significant difference was found between phosphoric etchant group and control group with respect to shear bond strength. Conclusion. Empress 2 ceramic surface was not etched by phosphoric acid, but etched by hydrofluoric acid.

A Study on the Architectural Design Utility of Object-based CAD System (객체기반 CAD 시스템의 건축설계적 효용에 관한 연구)

  • Yoo, Chang-Geun
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.2 no.1
    • /
    • pp.9-15
    • /
    • 2002
  • As architectural forms tend to be large-scaled, high-storied and complicated, use of computer for processing design information has been generalized. However, CAD use in the process of developing architectural design has been neglected greatly in the educational field of architectural field due to the surging of recognition that it may limit the essential property of architectural design. It may be resulted from the limitation of CAD system, that is, it is because of tardy speed of application development for the related areas with the lack of simplicity and clarity of flexibility to be secured on the drawing and user interface. Recent CAD systems, however, overcome such a limitation, convert into object-based design from entity-based drawing, drafting and modeling for implementing design concept of architects and it connects with internet linked to superspeed information communication network and changes process and stream of architectural design. Therefore, this study deals with utility of object based CAD system with products of Autodesk Co. and consequently obtain the following conclusions. First, it expands architect's design areas by supporting cooperative design system based on model-based architectural design and internet. Second, it reduces consumption of personal and material resources and time in the process of drawing production for improving architectural design works. Third, it can reduce the frequent design changes by improving understanding of architectural space with visualization of immediate 3D information, escaping from traditional methods to deliver design information to building owner through 2D drawing or model and perspective drawing requiring much cost and time. Fourth, it keeps exactness without omission or duplication of design information and generate and renew information of all related drawings on a drawing. Fifth, it is possible to change difficult and boring architectural design work into a pleasure owing to immediate modeling and drawing of design idea. In addition, digital drawing generated by using object-based CAD system can playa role of establishing Urban Information System to be used for protecting from building in disaster and urban disasters in connection with GIS numerical map and be used for reference of all kinds of information required fro post-management of buildings. However, what is more important is that surplus time from introduction of object-based CAD system should be used for consideration to be recognized as a good space and building built as a product of this project for comfort to urban people.

  • PDF

A STUDY ON THE TENSILE STRENGTH OF REINFORCED VENEERING COMPOSITE RESINS FOR CROWN (강화형 치관용 복합레진의 인장강도에 관한 연구)

  • Ahn, Seung-Geun;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.226-241
    • /
    • 2000
  • Recently a new generation of crown and bridge veneering resins containing submicron glass fillers was introduced. These ultrasmall particle hybrid composite materials distinguish themselves, compared with conventional microfill crown and bridge resins, through improved mechanical properties. It is claimed that these composites are suitable for metal free crowns and even bridges using fiber reinforcement. The purpose of this study was to evaluate the effect of thermal cycling on the tensile strength of the following veneering composites: Artglass(Heraeus Kulzer Co., Wehrheim, Germany), Estonia(Kuraray Co.. Japan), Sculpture(Jeneric Pentron Co., Wallingford, U.S.A.), and Targis(Ivoclar Co., Schaan Liechenstein). According to manufacturer's instructions, rectangular tensile test specimens measuring $1.5{\times}2.0{\times}4.5mm$ were made using a teflon mold. Whole specimens were divided into two groups. One group was dried in a desiccator at $25^{\circ}C$ for 10 days, and another group was subjected to thermal cycling($10,000{\times}$) in water($5/55^{\circ}C$). All test specimens were placed in a universal testing machine and loaded until fracture with a crosshead speed of 0.5mm/min. Weibull analysis and Tukey's test were used to analyze the data. The fracture surfaces of specimens were observed in SEM and the aliphatic C=C absorbance peak of Estenia and Targis resin was analyzed using Fourier transform infrared(FTIR) spectroscopy. Within the limitations imposed in this study, the following conclusions can be drawn: 1. Both in drying condition and thermal cycling condition, the highest tensile strength was observed in Estenia testing group(p<0.05). 2. The strength data were at to single-mode Weibull distribution, and the Weibull modulus of all veneering composite resin specimens increased after thermal cycling treatment. 3. After thermal cycling test, the highest tensile strength was observed in the Estenia group, and the lowest value was observed in the Targis group. The tensile strength values showed the significant differences between each group(p<0.05) 4. The aliphatic C=C absorbance peak of Estonia and Targis resin was decreased after light curing, and there was no distinct change after thermal cycling.

  • PDF

Evaluation of bone quality in alveolar crest obscured by dental implants ; A pilot study by densitometric digital analysis in mandibular bone specimen (치과 임플란트 주변 협설측 치조골의 변화분석 - 하악골 시편에서의 디지털 농도분석법을 이용한 실험적 고찰 -)

  • Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.900-913
    • /
    • 1998
  • Despite of technical difficulties, the combination of occlusal projection and densitometric digital analysis may ultimately provide a means of detection of subtle bone loss at the facial and lingual side of dental implant (Oblique occlusal view is more useful for $ITI^{(R)}$ dental implant due to its contour of shoulder as like tulip flower). In this study, conventional periapical projections of x-ray beam had shown more high sensitivity to detect the bony defects than oblique occlusal projections in alveolar crest obscured by dental implants or not, even if the difference was not statistically significant. Unlike conventional periapical projections. occusal projections combined with densitometric digital analysis technique may provide a means for detection of subtle bone change at the all around of implants without obscuring effect by implant itself. Although the results from this in vitro study were performed under limited circumstances, these results might afford more possibility and versatile modality of diagnosis options to clinician in the implant practice.

  • PDF

Analysis of Seismic Response of the Buried Pipeline with Pipe End Conditions (II) (단부 경계조건을 고려한 매설관의 동적응답 해석 (II))

  • Lee, Byong-Gil;Park, Byung-Ho;Jeong, Jin-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.328-337
    • /
    • 2005
  • This work reports results of our study on the dynamic responses of the buried pipelines both along the axial and the transverse directions under various boundary end conditions. We have considered three cases, i.e., the free ends, the fixed ends, and the fixed-free ends for the axial direction, and three more cases including the guided ends, the simply supported ends, and the supported-guided ends for the transverse direction. In order to investigate the effect of the boundary end conditions for the dynamic responses of the buried pipeline, we have devised a computer program to find the solutions of the formulae on the dynamic responses (displacements, axial strains, and bending strains) under the various boundary end conditions considered in this study. The dynamic behavior of the buried pipelines for the forced vibration is found to exhibit two different forms, a transient response and a steady state response, depending on the time before and after the transfer of a seismic wave on the end of the buried pipeline. The former is identified by a slight change in its behavior before the sinusoidal-shaped seismic wave travels along the whole length of the pipeline whereas the latter by the complete form of a sinusoidal wave when the wave travels throughout the pipeline. The transient response becomes insignificant as the wave speed increases. We have observed a resonance when the mode wavelength matches the wavelength of the seismic wave, where the mode number(k) of resonance for the axial direction is found to be $\overline{\omega}/{\pi}V+1/2$ for the fixed-free ends, $\overline{\omega}/{\pi}V+1$ for the free ends, and $\overline{\omega}/{\pi}V$ for the fixed ends, respectively. By adding 10 more modes to the mode number(k) of resonance, we were able to study all the dynamic responses of the buried pipeline for the axial direction. On the other hand, we have not been able to observe a resonance in the analysis for the transverse direction, because the dynamic responses are found to vanish after the seventh mode. From the results of the dynamic responses at the many points of the pipeline, we have found that the responses appeared to be dependent critically on the boundary end conditions. Such effects are found to be most prominent especially for the maximum values of the displacement and the strain and its position.

  • PDF

A Study on the Contamination of Solution with Suction used in Tracheostomy Patients (기관지절개술 환자의 흡인시 사용하는 용액의 오염수준 변화 연구)

  • Lim Yun-Hee;Yu Kwang Soo
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.185-200
    • /
    • 1998
  • It has been contributed to public health that the hospital has multiplied in the aspect of number and has been a large size with development of modern medical science, meanwhile the problem of hospital infection is coming out seriously. Respiratory hospital infection among hospital infections develops, very commonly from patients having taken the operation of intubation or tracheostomy, which results from a big factor that the infection developed from medical appliances used for respiration aids, contamination of solution and infection of medical staff. This study is separated into four steps-the time to use normal saline and distillation water for storaging catheter which are the cause of the infection of solution to store distillation water and catheter, not to say the catheter used when the patient who should get tracheostomy operation takes suction. The purpose of this study is to offer the basic data which are needed to check contamination degree as time goes by and nurse intervention and grope for a new nursing intervention. The target of this study is hospitalized 1D an intensive care unit having 700 sickbeds which is located in IKSAN city and it targeted patients before 7 days passed after an operaion of a tracheostormy. Materials collected were analyzed by SPSS PC+ figures program. The result of this study were as follows ; 1. The gradual contamination levels of the normal saline used In suction are showing that colony increase in proportion to the length of time. 2. while colony increases in normal saline with the lapse of time. distillation water mixed with 5cc of potadine did not show any sign of the formation of colony from its preparation until it was used for 8 hours. 3. Such variables as the period of intubation insertion. the length of hospitalization in I.C.U. the age and the level of contamination of normal saline have no inter-relationship. Therefore. as the length of normal saline used In suction. the contamination level increases with the excelleration of the contamination speed. 4. Regarding the number of suction and the contamination level of the normal saline. We can observe correlation contamination level in the 3 step of suction(mean value:13.4) and the saline which was used for one hours(r=0.702. P=0.00l). four hours(r=0.694. P=0.00l). eight hours(r=0.488. P=0.029). Further we can observe contamination in the 4 step of suction (mean value: 17 .8) well as saline used for eight hours; [for one hours (r=0.64l. P=0.002). four hours (r=0.670. P=0.00l). eight hours (r=0.57 4. P=0.008)]. Thesedays clinics use normal saline by changing it. three times a day. however. the timing of saline change and the current suction methoed should be changed given the one hour used normal saline contamination number 79.850. Regarding the number of suction and the contamination lend of the normal saline.

  • PDF