• 제목/요약/키워드: Spectrum shift

검색결과 364건 처리시간 0.024초

GENERALIZED BROWDER, WEYL SPECTRA AND THE POLAROID PROPERTY UNDER COMPACT PERTURBATIONS

  • Duggal, Bhaggy P.;Kim, In Hyoun
    • 대한수학회지
    • /
    • 제54권1호
    • /
    • pp.281-302
    • /
    • 2017
  • For a Banach space operator $A{\in}B(\mathcal{X})$, let ${\sigma}(A)$, ${\sigma}_a(A)$, ${\sigma}_w(A)$ and ${\sigma}_{aw}(A)$ denote, respectively, its spectrum, approximate point spectrum, Weyl spectrum and approximate Weyl spectrum. The operator A is polaroid (resp., left polaroid), if the points $iso{\sigma}(A)$ (resp., $iso{\sigma}_a(A)$) are poles (resp., left poles) of the resolvent of A. Perturbation by compact operators preserves neither SVEP, the single-valued extension property, nor the polaroid or left polaroid properties. Given an $A{\in}B(\mathcal{X})$, we prove that a sufficient condition for: (i) A+K to have SVEP on the complement of ${\sigma}_w(A)$ (resp., ${\sigma}_{aw}(A)$) for every compact operator $K{\in}B(\mathcal{X})$ is that ${\sigma}_w(A)$ (resp., ${\sigma}_{aw}(A)$) has no holes; (ii) A + K to be polaroid (resp., left polaroid) for every compact operator $K{\in}B(\mathcal{X})$ is that iso${\sigma}_w(A)$ = ∅ (resp., $iso{\sigma}_{aw}(A)$ = ∅). It is seen that these conditions are also necessary in the case in which the Banach space $\mathcal{X}$ is a Hilbert space.

Self-Encoded Spread Spectrum with Iterative Detection under Pulsed-Noise Jamming

  • Duraisamy, Poomathi;Nguyen, Lim
    • Journal of Communications and Networks
    • /
    • 제15권3호
    • /
    • pp.276-282
    • /
    • 2013
  • Self-encoded spread spectrum (SESS) is a novel modulation technique that acquires its spreading code from a random information source, rather than using the traditional pseudo-random noise (PN) codes. In this paper, we present our study of the SESS system performance under pulsed-noise jamming and show that iterative detection can significantly improve the bit error rate (BER) performance. The jamming performance of the SESS with correlation detection is verified to be similar to that of the conventional direct sequence spread spectrum (DSSS) system. On the other hand, the time diversity detection of the SESS can completely mitigate the effect of jamming by exploiting the inherent temporal diversity of the SESS system. Furthermore, iterative detection with multiple iterations can not only eliminate the jamming completely but also achieve a gain of approximately 1 dB at $10^{-3}$ BER as compared with the binary phase shift keying (BPSK) system under additive white gaussian noise (AWGN) by effectively combining the correlation and time diversity detections.

Tone 신호방해 하에서의 DS/SFH 복합 확산대역 시스템의 비트오율 (Error Probability of a Hybrid DS/SFH Spread-Spectrum System under Tone Jamming)

  • 유병석;이재홍;이상철
    • 대한전자공학회논문지
    • /
    • 제27권5호
    • /
    • pp.645-655
    • /
    • 1990
  • A hybrid DS/SFH spread spectrum system is used to achieve a larger gain in some applications. The probability of error for a hybrid DS/SFH(direct sequence/slow frequency hopped) spread-spectrum system is calculated over a channel which suffers from multiple-tone jamming and additive white Gaussian noise. BPSK(binary phase shift keying) is considered as modulation scheme. The probability of error is computed for various system parameters such as a DS/SFH hybrid ratio, the number of jamming tones, a jamming-to-signal ratio, and a siganl-to-noise ratio. It is shown that a DS system or a SFH system achieves smaller probability of error than a hybrid DS/SFH system for most values of system parameters. However, it is also shown that there are hybrid ratios with which a hybrid DS/SFH system achieves smaller probability of error than a DS system and a SFH system achieve for some values of system parameters.

  • PDF

Analysis of the spectral characteristics of white light-emitting diodes under various thermal environments

  • Jeong, Su-Seong;Ko, Jae-Hyeon
    • Journal of Information Display
    • /
    • 제13권1호
    • /
    • pp.37-42
    • /
    • 2012
  • An empirical functional form was suggested for the analysis of the emission spectrum of high-power light-emitting diode (LED) consisting of a sharp blue peak from the LED chips and a broad yellow peak from the phosphor layer. The peak positions, half widths, shape parameters, and amplitudes of these two peaks were reliably obtained as a function of the temperature, and the results were discussed qualitatively in relation with the junction temperature. The adoption of an inert liquid was found to have significantly reduced the LED temperature and the color shift of the emitted light. The phenomenological approach used in this study may be helpful in the simulation of the LED spectrum under various thermal conditions, and may thus be helpful in the improvement of the device performance.

A method of measuring frequency response function by use of characteristic M-sequence

  • Sakata, Masato;Kashiwagi, Hiroshi;Kitajima, Unpei
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국제학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.943-946
    • /
    • 1988
  • A simple method is proposed for determining the frequency response function G(j.omega.) of a system using a pair of characteristic M-sequences (maximum length linear feed back shift register sequence). When a characteristic M-sequence is sampled with q$_{1}$ and q$_{2}$ both of which are coprime with N, where N is the period of the M-sequence, the obtained pair of sequences have conjugate complex frequency spectrum. Making use of this fact, two charcteristic M-sequences having conjugate complex frequency spectrum are applied to a system to be measured. Since the magnitude of spectrium of M-sequence is known, the gain of G(j.omega.) is directly obtained from the Fourier transform of the system output. The phase of G(j.omega.) is obtained simply by taking the average of the two phases of output spectrum.

  • PDF

THE NIGHT SKY SPECTRUM OF MOUNT BOHYUN

  • SHEEN YUN-KYEONG;BYUN YONG-IK
    • 천문학회지
    • /
    • 제37권2호
    • /
    • pp.87-90
    • /
    • 2004
  • Spectrophotometry of the night sky over Mount Bohyun is presented for the nearly entire visible wavelengths of $3600{\~}$8600{\AA}$. The data was obtained under moonless clear sky in February 2004 with the 1.8-m telescope and the long slit spectrograph. The sky spectrum shows a number of strong emission lines originated from light pollution, especially due to high pressure sodium lamps. When compared to the night sky of Kitt Peak, our sky continuum is 1 to 2 magnitude brighter at all wavelengths, the worst being around the broad emission region near 6000${\AA}$. The night sky spectrum presented here with almost complete line identifications is a useful reference for arc-independent wavelength calibrations to check the gravity flexure of the spectrograph and the wavelength shift between FeNeArHe arc frames and science frames.

가스크로마토그래피 질량분석기의 질량 스펙트럼 해상도 개선 알고리즘 (Algorithm to Improve Mass Spectral Resolution of Gas Chromatography Mass Spectrometer)

  • 최훈
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1232-1238
    • /
    • 2018
  • This paper proposes methods for improving mass spectral resolution for a gas chromatograph mass spectrometer. The slope signs of the 1st and 2nd fitting functions for the ion signal block of each mass index are obtained, and the unnecessary element signals in the ion signal block are removed. The spectrum can be obtained by obtaining the second-order fitting function of the reconstructed ion signal block using only the effective ion signals. In addition, the resolution of the mass spectrum can be improved by correcting the error caused by the shift of the spectral peak position. To verify the performance of the proposed methods, computer simulations were performed using the actual ion signals obtained from the GC-MS system under development. Simulation results show that the proposed method is valid.

회전 표적의 고주파수 후방산란단면적 해석 (High-frequency Back-scattering Cross Section Analysis of Rotating Targets)

  • 김국현;조대승;김진형
    • 한국군사과학기술학회지
    • /
    • 제10권3호
    • /
    • pp.16-24
    • /
    • 2007
  • The high-frequency analysis method of back-scattering cross section spectrum of rotating targets is established. The time history of the back-scattering cross section is calculated using a quasi-stationary approach, based on a physical optics and a physical theory of diffraction, combining an adaptive triangular beam method to consider the shadow effect. And the spectra of back-scattering cross section by the Doppler effect are analyzed applying a simple fast Fourier transform method to its time history. The numerical calculation for rotating targets, such as rotating metal plates and underwater propeller, are carried out. The time history appears to be periodic with respect to the number of wings. The backscattering cross section spectrum level and its frequency shift are dependent on the rotating speed, direction, and the shape of the targets.

Neutron Spectrum Effects on TRU Recycling in Pb-Bi Cooled Fast Reactor Core

  • Kim Yong Nam;Kim Jong Kyung;Park Won Seok
    • Nuclear Engineering and Technology
    • /
    • 제35권4호
    • /
    • pp.336-346
    • /
    • 2003
  • This study is intended to evaluate the dependency of TRU recycling characteristics on the neutron spectrum shift in a Pb-Bi cooled core. Considering two Pb-Bi cooled cores with the soft and the hard spectrum, respectively, various characteristics of the recycled core are carefully examined and compared with each other. Assuming very simplified fuel cycle management with the homogeneous and single region fuel loading, the burnup calculations are performed until the recycled core reached to the (quasi-) equilibrium state. The mechanism of TRU recycling toward the equilibrium is analyzed in terms of burnup reactivity and the isotopic compositions of TRU fuel. In the comparative analyses, the difference in the recycling behavior between the two cores is clarified. In addition, the basic safety characteristics of the recycled core are also discussed in terms of the Doppler coefficient, the coolant loss reactivity coefficient, and the effective delayed neutron fraction.

Interaction between Norfolxacin and Single Stranded DNA

  • 여정아;조태섭;Kim, Seog K.;문형랑;준길자;남원우
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권4호
    • /
    • pp.449-457
    • /
    • 1998
  • We compared various spectroscopic properties of a norfloxacin-single stranded DNA complex with those of norfloxacin-double stranded DNA complex. Norfloxacin binds to both double-and single stranded DNA, and we observed the following spectroscopic changes for both complexes: hypochromism in the norfloxacin absorption region in the absorption spectrum, the characteristic induced CD spectrum consisting of a weak positive band at 323 nm and a strong positive band at 280-300 nm followed by a negative band in the 260 nm region, a strong decrease in the fluorescence intensity and a red-shift in the fluorescence emission spectrum, and shorter fluorescence decay times. These results indicate that the environments of the bound norfloxacin in both DNAs are similar, although the equilibrium constant of the norfloxacin-single stranded DNA was twice as high as the norfloxacin-double stranded DNA complex. Both complexes were thermodynamically favored with similar negative Δ$G^o$. Negative Δ$H^o$ terms contribute to these spontaneous reactions; Δ$S^o$ term was unfavorable.