• Title/Summary/Keyword: Spectrum data

Search Result 2,069, Processing Time 0.032 seconds

Ex Vivo ${1}^H$ MR Spectroscopy: Normal gastric and cancer tissue (정상 위 조직과 위암 조직의 시험관 내 수소자기공명분광)

  • Cho Ji Youn;Shin Oon Jae;Choi Ki Seung;Kim Su Hyun;Eun Choong Ki;Yang Young Il;Lee Jung Hee;Mun Chi Woong
    • Journal of Gastric Cancer
    • /
    • v.3 no.3
    • /
    • pp.151-157
    • /
    • 2003
  • Purpose: In this study, we attempted to ascertain the proton magnetic resonance spectroscopy (${1}^H$ MRS) peak characteristics of human gastric tissue layers and finally to use the metabolic peaks of MRS to distinguish between normal and abnormal gastric specimens. Materials and Methods: Ex-vivo ${1}^H$ MRS examinations of thirty-five gastric specimens were performed to distinguish abnormal gastric tissues invaded by carcinoma cells from normal stomach-wall tissues. High-resolution 400-MHz (9.4-T) ${1}^H$ nuclear magnetic resonance (NMR) spectra of two gastric layers, a proper muscle layer, and a composite mucosasubmucosa layer were compared with those of clinical 64- MHz (1.5-T) MR spectra. Three-dimensional spoiled gradient recalled (SPGR) images were used to determine the size and the position of a voxel for MRS data collection. Results: For normal gastric tissue layers, the metabolite peaks of 400-MHz ${1}^H$ MRS were primarily found to be as follows: lipids at 0.9 ppm and 1.3 ppm; alanine at 1.58 ppm; N-acetyl neuraminic acid (sialic acid) at 2.03 ppm; and glutathione at 2.25 ppm in common. The broad and featureless featureless spectral peaks of the 64-MHz MRS were bunched near 0.9, 1.3, and 2.0, and 2.2 ppm in human specimens without respect to layers. In a specimen (Borrmmann type III) with a tubular adenocarcinoma, the resonance peaks were measured at 1.26, 1.36 and 3.22 ppm. All the peak intensities of the spectrum of the normal gastric tissue were reduced, but for gastric tumor tissue layers, the lactate peak split into 1.26 and 1.39 ppm, and the peak intensity of choline at 3.21 ppm was increased. Conclusion: We found that decreasing lipids, an increasing lactate peak that split into two peaks, 1.26 ppm and 1.36 ppm, and an increasing choline peak at 3.22 ppm were markers of tumor invasion into the gastric tissue layers. This study implies that MR spectroscopy can be a useful diagnostic tool for gastric cancer.

  • PDF

Determination of Iodine Contents in Ten kinds of Frequently used Oriental Herb Medicinal Products for Cancer Patient (암환자에게 다빈도로 활용되는 한약제제 10종에 대한 요오드의 함량 분석)

  • Lee, Chang-Hee;Choi, Jung-Eun;Kim, Sun-Ha;Chung, Yong-Sam;Moon, Jong-Hwa;Yoo, Hwa-Seung
    • Journal of Korean Traditional Oncology
    • /
    • v.16 no.1
    • /
    • pp.41-53
    • /
    • 2011
  • Background and Objectives: Iodine is an essential constituent of the thyroid hormones associated with the growth and development of humans and animals as an inorganic nutrition. This element may be accumulated in human blood, tissues and body through the intake of foodstuffs, a beverage, a nutritional supplement and a medicine, among others. The aim of the research is to find out a better medicinal stuff for the thyroid cancer patient who required a low level of iodine diet. Methods: Neutron activation analysis (NAA) used for the iodine analysis is one of nuclear analytical techniques using radiation and radioisotopes and very useful as sensitive analytical technique for performing both qualitative and quantitative multi-elemental non-destructive analysis of major, minor and trace components in variety of environmental and biological materials. In this study, iodine contents in ten kinds of oriental herb medicinal products, which is frequently used to cancer patients are determined by using instrumental neutron activation analysis (INAA) at the HANARO research reactor. The samples prescribed are manufactured as powdered form for taking medicine easily. The analytical quality control is performed to assure an uncertainty of the measurement and to compensate the measured data using a biological certified reference material, NIST SRM 1572, Citrus Leaves. The measured value is $1.89{\pm}0.35mg/kg$, and the relative error is 2.88%, and relative standard deviation is 19 % due to high counting error by small counts of gamma ray spectrum. The standard deviations for other elements such as Cl, K, Mn and Na were in the range of 2 to 8%. Result: The level of iodine contents of Biki-huan, Chungryong-huan and Chungcho-huan, samples detected is less than 6 mg/kg except Hangam Plus sample (more than 210 mg/kg) and six samples were not detected. Iodine in the samples of Shoxiho-tang, Shopunghualhyl-tang, Shocungryong-tang, Banhasaxim-tang, Insampaedox-san and Myunyuk Plus were not measured, but possible level of content can be estimated from the detection limits. In addition, the concentrations of some major elements like Cl, K, Mn, Na, in the samples were determined with the detection limits. Conclusions: Most of samples showed low iodine contents of less than 6 mg/kg but it turned out that most of testing samples can be used to classify the level of iodine diet samples considering the recommended low level of iodine diet 50 ${\mu}g$/day, and a better medicinal stuff for the thyroid cancer patient can be found.

Synthesis and Emulsion Properties of Self-emulsifiable Polyethylene Waxes (자기유화 폴리에틸렌 왁스의 합성 및 에멀젼 특성 연구)

  • Yang, Jeongin;Lee, Sangjun;Shin, Jihoon;Han, Won Hee;Hong, Min Hyuk;Kim, Young-Wun
    • Applied Chemistry for Engineering
    • /
    • v.28 no.6
    • /
    • pp.670-678
    • /
    • 2017
  • Self-emulsifiable polyethylene (PE) wax was prepared using acrylic acid grafted PE wax with potassium hydroxide and various emulsifiers for the economic production of PE wax emulsion. Modification reaction completion was confirmed that the peak from carbonyl group of acrylic acid disappeared and the new peak from carboxylic acid salts appeared in the FT-IR (Fourier transform infrared) spectrum data. Self-emulsifiable properties of the modified PE wax were investigated by the emulsion size and the stability of wax emulsion without any additional emulsifiers. According to self-emulsifiable properties, the emulsion size and stability were varied on the concentration and structure of the emulsifier. The greater emulsion concentration and hydrophilic poly(ethylene oxide) (PEO) characteristics of the emulsifier resulted in the smaller emulsion size and better emulsion stability. In addition, the use of emulsifiers mixture was more effective to obtain smaller size and uniform distribution of emulsion than that of single emulsifier in PE wax modification reaction. Especially, modified PE wax with OAE-5 and LAE-15 emulsifiers mixture shows excellent performance in terms of the smallest emulsion size ($4.34{\mu}m$) and emulsion stability.

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.

Harmonic Signal Linearization of Nonlinear Power Amplifier Using Digital Predistortion for Multiband Wireless Transmitter (다중 대역 송신을 위한 디지털 사전 왜곡 기법을 이용한 비선형 전력 증폭기의 고조파 신호 선형화)

  • Oh, Kyung-Tae;Ku, Hyun-Chul;Kim, Dong-Su;Hahn, Cheol-Koo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1339-1349
    • /
    • 2008
  • In this paper, a nonlinear relationship between an input complex envelope and an output complex envelope of m-th harmonic zone is theoretically analyzed, and AM/$AM_m$ and AM/$PM_m$ are defined. A scheme to extract these characteristics from measured in-phase and quadrature-phase data is suggested. The proposed analysis is verified with a fundamental-fundamental and fundamental-third harmonic measurements for a InGaP power amplifier(PA). Based on the harmonic-band nonlinear analysis and extraction scheme, a new technique to send a signal in m-th harmonic band with a harmonic signal Linearization Digital Predistortion(DPD) scheme is presented. A numerical analysis and a Look-Up Table(LUT) based DPD algorithms to linearize output signal on m-th harmonic zone are developed. For a 16- and a 64-QAM input signals, a DPD for third harmonic signal linearization is implemented, and output spectrum and signal constellation are measured. The wholly distorted signals are linearized, and thus the measured Error Vector Magnitudes (EVM) are 6.4 % and 6.5 % respectively. The results show that a proposed scheme linearizes a nonlinearly distorted harmonic band signals. The proposed nonlinear analysis and predistortion scheme can be applied to multiband transmitter in next generation software defined radio(SDR)/cognitive radio(CR) wireless system.

Accuracy Verification of Theoretical Models for Estimating Microwave Reflection from Rough Sea Surfaces (거친 바다표면의 마이크로파 반사 계산을 위한 이론적 모델 정확도 검증)

  • Park, Sinmyong;Oh, Yisok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.10
    • /
    • pp.788-793
    • /
    • 2017
  • This paper presents the verification of accuracies of theoretical models for calculating the microwave reflections from rough sea surfaces. First of all, the Pierson-Moskowitz ocean spectrum was used to generate the rough sea surfaces. Then the relationship between the significant wave heights, root-mean-square(RMS) heights and wind speed was derived by estimating the significant wave heights and RMS heights of the generated sea surfaces according to various wind speeds, and compared the derived relationship with other measurement data sets. The reflection coefficients of the sea surfaces were calculated by using a numerical method(the moment method). Then, the numerical results were compared with Ament model, PO(Physical Optics) model, GO(Geometrical Optics) model and B-M(Brown-Miller) model for various roughness conditions(wind speed) and incidence angles. It was found that the Ament model is not accurate except for a very low roughness conditions($kh_{rms}$<0.4, k is wavenumber and $h_{rms}$ is RMS height). It was also found that at incidence angles lower than $70^{\circ}$, the PO and the GO models agree well with the numerical results, while the B-M model agrees well with the numerical analysis results at incidence angles higher than $80^{\circ}$ for very rough sea surfaces with $kh_{rms}$>10.

Radiation Shielding Analysis on The Spent Fuel Storage Facility for the Extended Fuel Cycle (장주기(長週期) 핵연료(核燃料) 저장시설(貯藏施設)에서의 방사선차폐해석(放射線遮蔽解析))

  • Lee, Tae-Young;Ha, Chung-Woo;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.90-96
    • /
    • 1984
  • Estimated dose rates in spent fuel pool storage with the extended fuel cycle core management were reviewed and compared with design limit after calculation with the aid of DLC-23/CASK(22 n, 18 g) nuclear data and ANISN code. Radioactivity and gamma spectrum within spent fuel assemblies were calculated with ORIGEN code by extended fuel cycle model. In the calculation of dose rate, the fuel pool geometry was assumed to be infinite slab. Also, composition materials and radiation source within assemblies which are being stored in pool storage were assumed to be uniformly distributed throughout all the assemblies. As a result of culculation of dose rate from stored assemblies and waterborne radionuclides in pool water, the calculated dose rates appear to be lower than design basis limit under normal condition as well as abnormal condition.

  • PDF

Reinterpretation of the protein identification process for proteomics data

  • Kwon, Kyung-Hoon;Lee, Sang-Kwang;Cho, Kun;Park, Gun-Wook;Kang, Byeong-Soo;Park, Young-Mok
    • Interdisciplinary Bio Central
    • /
    • v.1 no.3
    • /
    • pp.9.1-9.6
    • /
    • 2009
  • Introduction: In the mass spectrometry-based proteomics, biological samples are analyzed to identify proteins by mass spectrometer and database search. Database search is the process to select the best matches to the experimental mass spectra among the amino acid sequence database and we identify the protein as the matched sequence. The match score is defined to find the matches from the database and declare the highest scored hit as the most probable protein. According to the score definition, search result varies. In this study, the difference among search results of different search engines or different databases was investigated, in order to suggest a better way to identify more proteins with higher reliability. Materials and Methods: The protein extract of human mesenchymal stem cell was separated by several bands by one-dimensional electrophorysis. One-dimensional gel was excised one by one, digested by trypsin and analyzed by a mass spectrometer, FT LTQ. The tandem mass (MS/MS) spectra of peptide ions were applied to the database search of X!Tandem, Mascot and Sequest search engines with IPI human database and SwissProt database. The search result was filtered by several threshold probability values of the Trans-Proteomic Pipeline (TPP) of the Institute for Systems Biology. The analysis of the output which was generated from TPP was performed. Results and Discussion: For each MS/MS spectrum, the peptide sequences which were identified from different conditions such as search engines, threshold probability, and sequence database were compared. The main difference of peptide identification at high threshold probability was caused by not the difference of sequence database but the difference of the score. As the threshold probability decreases, the missed peptides appeared. Conversely, in the extremely high threshold level, we missed many true assignments. Conclusion and Prospects: The different identification result of the search engines was mainly caused by the different scoring algorithms. Usually in proteomics high-scored peptides are selected and low-scored peptides are discarded. Many of them are true negatives. By integrating the search results from different parameter and different search engines, the protein identification process can be improved.

Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source (코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성)

  • 최태진;이호준;김옥배
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • To achieve the 2D dose distribution around the designed high dose rate Ir-192 source substitution for Co-60 brachytherapy source, we determined the exposure rate constant and tissue attenuation factors as a large depth as a 20 cm from source center. The exposure rate constant is used for apparent activity in designed source with self-absorption and encapsulation steel wall. The tissue dose delivered from the 4401 segments of 2.5 mm in a diameter and 2.5 mm height of disk-type source layer. In the experiments, the tissue attenuation factors include the tissue attenuation and multiple scattering in a medium surrounding the source. The fitted the polynomial regression with 4th order for the tissue attenuation factors are very closed to the experimental measurement data within ${\pm}$1% discrepancy. The Meisberger's constant showed the large uncertainty in large distance from source. The exposure rate constant 4.69 Rcm$^2$/mCi-hr was currently used for determination of apparent activity of source and air kerma strength was obtained 0.973 for tissue absorbed dose from the energy spectrum of Ir-192 source. In our experiments with designed high dose rate brachytherapy source, the apparent activity of Ir-192 source was delivered from the 54.6 % of actual physical source activity through the self-absorption and encapsulation wall attenuations. This paper provides the 2-dimensional dose tabulation from unit apparent activity in a water medium for dose planning includes the multiple scattering, source anisotropy effect and geometric factors.

  • PDF

A Molecular Dynamics Simulation Study of Hydroxyls in Dioctahedral Phyllosilicates (분자동역학 시뮬레이션을 이용한 이팔면체 점토광물 수산기 연구)

  • Son, Sangbo;Kwon, Kideok D.
    • Journal of the Mineralogical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.209-220
    • /
    • 2016
  • Clay minerals are a major player to determine geochemical cycles of trace metals and carbon in the critical zone which covers the atmosphere down to groundwater aquifers. Molecular dynamics (MD) simulations can examine the Earth materials at an atomic level and, therefore, provide detailed fundamental-level insights related to physicochemical properties of clay minerals. In the current study, we have applied classical MD simulations with clayFF force field to dioctahedral clay minerals (i.e., gibbsite, kaolinite, and pyrophyllite) to analyze and compare structural parameters (lattice parameter, atomic pair distance) with experiments. We further calculated vibrational power spectra for the hydroxyls of the minerals by using the MD simulations results. The MD simulations predicted lattice parameters and interatomic distances respectively deviated less than 0.1~3.7% and 5% from the experimental results. The stretching vibrational wavenumber of the hydroxyl groups were calculated $200-300cm^{-1}$ higher than experiment. However, the trends in the frequencies among different surface hydroxyl groups of each mineral was consistent with experimental results. The angle formed by the surface hydroxyl group with the (001) plane and hydrogen bond distances of the surface hydroxyls were consistent with experimental result trends. The inner hydroxyls, however, showed results somewhat deviated from reported data in the literature. These results indicate that molecular dynamics simulations with clayFF can be a useful method in elucidating the roles of surface hydroxyl groups in the adsorption of metal ions to clay minerals.