Radiation Shielding Analysis on The Spent Fuel Storage Facility for the Extended Fuel Cycle

장주기(長週期) 핵연료(核燃料) 저장시설(貯藏施設)에서의 방사선차폐해석(放射線遮蔽解析)

  • Published : 1984.12.15

Abstract

Estimated dose rates in spent fuel pool storage with the extended fuel cycle core management were reviewed and compared with design limit after calculation with the aid of DLC-23/CASK(22 n, 18 g) nuclear data and ANISN code. Radioactivity and gamma spectrum within spent fuel assemblies were calculated with ORIGEN code by extended fuel cycle model. In the calculation of dose rate, the fuel pool geometry was assumed to be infinite slab. Also, composition materials and radiation source within assemblies which are being stored in pool storage were assumed to be uniformly distributed throughout all the assemblies. As a result of culculation of dose rate from stored assemblies and waterborne radionuclides in pool water, the calculated dose rates appear to be lower than design basis limit under normal condition as well as abnormal condition.

장주기핵연료(長週期核燃料) 노심기법(爐心技法)에 의한 사용후핵연료(使用後核燃料)가 기존(旣存) 사용후핵연료저장시설(使用後核燃料貯藏施設)의 설계변경(設計變更)없이 동(同) 시설(施設)에 수용(受容) 가능(可能)한지를 결정(決定)하기 위하여 저장시설(貯藏施設)에서의 예상(豫想) 방사선피폭선량률(放射線被曝線量率) DLC-23/CASK (22n, 18g) 단면적(斷面積)자료(資料)와 ANISN-W 전산(電算)코드로 계산(計算)하여 설계기준치(設計基準値)와 비교(比較) 검토(檢討)하였다. 사용후핵연료내(使用後核燃料內)의 방사능량(放射能量) 및 감마선스펙트럼은 핵연료교체(核燃料交替)모델에 따라 ORIGEN 전산(電算)코드로 계산(計算)하였다. 방사선량률(放射線量率)의 계산(計算)에 있어서 저장조(貯藏槽)의 기하학적(幾何學的) 모델은 무한평판모형(無限平板模型)이며 저장(貯藏)된 사용후핵연료(使用後核燃料)의 구성물질(構成物質)과 방사선원(放射線源)은 핵연료집합체내(核燃料集合體內)에 균일(均一)하게 분포(分布)되었다고 가정(假定)하였다. 사용후핵연료저장조(使用後核燃料貯藏槽)에 저장(貯藏)된 핵연료집합체(核燃料集合體) 및 저장용수중(貯藏用水中) 방사성핵종(放射性核種)에 의한 방사선량률(放射線量率)의 계산(計算) 결과(結果)는 정상(正常) 및 사고수면시(事故水面時) 계산(計算)된 방사선량률(放射線量率)이 설계기준치(設計基準値)를 만족(滿足)시켜주는 것으로 나타났다.

Keywords