• Title/Summary/Keyword: Spectrum data

Search Result 2,069, Processing Time 0.038 seconds

Univariate and Multivariate Analysis of Phenotypic Traits in Mung Beans Reveals Diversity Among Korean, Indian, and Chinese Accessions

  • Kebede Taye Desta;Young-ah Jeon;Myoung-Jae Shin;Yu-Mi Choi;Jungyoon Yi;Hyemyeong Yoon
    • Korean Journal of Plant Resources
    • /
    • v.37 no.3
    • /
    • pp.270-306
    • /
    • 2024
  • This study investigated the diversity of 323 mung bean accessions from Korea, China, and India, along with six cultivars, using 22 agronomical traits. The standardized Shannon-Weaver index (H') for the qualitative traits ranged from 0.11 (terminal leaflet shape) to 0.98 (pubescence density of pod). Likewise, the coefficient of variation for the quantitative traits ranged from 8.76% (days to maturity (DM)) to 79.91% (lodging rate (LR)), indicating a wide genetic variance. Hypocotyl color, pod color, seed shape, and seed coat surface lust showed different distributions among Korean, Indian, and Chinese accessions. Chinese accessions had the highest average germination rate, DM, days from flowering to maturity, and one-hundred seeds weight, followed by Korean and Indian accessions, while the number of seeds per pod (SPP) displayed the opposite trend, with all except SPP showing significant variation (p < 0.05). Similarly, plant height, days to flowering, and number of pods per plant increased in the order of India > Korea > China, with LR showing the opposite trend (p < 0.05). The mung bean accessions were grouped into four major clusters using hierarchical cluster analysis supported by principal component analyses, and all of the quantitative traits showed significant variations between the clusters (p < 0.05). Generally, the mung bean accessions investigated in this study exhibited wide phenotypic trait variations, which could be beneficial for future genomics studies. Moreover, this study identified 77 accessions that outperformed the controls. Consequently, these superior accessions could provide a wide spectrum of options during the development of improved mung bean varieties.

Electroencephalography for Early Detection of Alzheimer's Disease in Subjective Cognitive Decline

  • YongSoo Shim;Dong Won Yang;SeongHee Ho;Yun Jeong Hong;Jee Hyang Jeong;Kee Hyung Park;SangYun Kim;Min Jeong Wang;Seong Hye Choi;Seung Wan Kang
    • Dementia and Neurocognitive Disorders
    • /
    • v.21 no.4
    • /
    • pp.126-137
    • /
    • 2022
  • Background and Purpose: Early detection of subjective cognitive decline (SCD) due to Alzheimer's disease (AD) is important for clinical research and effective prevention and management. This study examined if quantitative electroencephalography (qEEG) could be used for early detection of AD in SCD. Methods: Participants with SCD from 6 dementia clinics in Korea were enrolled. 18F-florbetaben brain amyloid positron emission tomography (PET) was conducted for all the participants. qEEG was performed to measure power spectrum and source cortical activity. Results: The present study included 95 participants aged over 65 years, including 26 amyloid PET (+) and 69 amyloid PET (-). In participants with amyloid PET (+), relative power at delta band was higher in frontal (p=0.025), parietal (p=0.005), and occipital (p=0.022) areas even after adjusting for age, sex, and education. Source activities of alpha 1 band were significantly decreased in the bilateral fusiform and inferior temporal areas, whereas those of delta band were increased in the bilateral cuneus, pericalcarine, lingual, lateral occipital, precuneus, posterior cingulate, and isthmus areas. There were increased connections between bilateral precuneus areas but decreased connections between left rostral middle frontal area and bilateral frontal poles at delta band in participants with amyloid PET (+) showed. At alpha 1 band, there were decreased connections between bilateral entorhinal areas after adjusting for covariates. Conclusions: SCD participants with amyloid PET (+) showed increased delta and decreased alpha 1 activity. qEEG is a potential means for predicting amyloid pathology in SCD. Further longitudinal studies are needed to confirm these findings.

Effect of remimazolam and propofol anesthesia on autonomic nerve activities during Le Fort I osteotomy under general anesthesia: blinded randomized clinical trial

  • Yuto Tsuji;Kyotaro Koshika;Tatsuya Ichinohe
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.24 no.4
    • /
    • pp.273-283
    • /
    • 2024
  • Background: This study evaluated the effect of remimazolam and propofol on changes in autonomic nerve activity caused by surgical stimulation during orthognathic surgery, using power spectrum analysis of blood pressure variability (BPV) and heart rate variability (HRV), and their respective associations with cardiovascular fluctuations. Methods: A total of 34 patients undergoing Le Fort I osteotomy were randomized to the remimazolam (Group R, 17 cases) or propofol (Group P, 17 cases) groups. Observables included the low-frequency component of BPV (BPV LF; index of vasomotor sympathetic nerve activity), high-frequency component of HRV (HRV HF; index of parasympathetic nerve activity), balance index of the low- and high-frequency components of HRV (HRV LF/HF; index of sympathetic nerve activity), heart rate (HR), and systolic blood pressure (SBP). Four observations were made: (1) baseline, (2) immediately before down-fracture, (3) down-fracture, and (4) 5 min after down-fracture. Data from each observation period were compared using a two-way analysis of variance with a mixed model. A Bonferroni multiple comparison test was performed in the absence of any interaction. One-way analysis of variance followed by Tukey's multiple comparisons test was performed when a significant interaction was observed between time and group, with P < 0.05 indicating statistical significance. Results: Evaluation of autonomic nerve activity in comparison with baseline during down-fracture showed a significant increase in BPV LF (P < 0.001), an increasing trend in HRV LF/HF in Group P, and an increasing trend in HRV HF in Group R. There were no significant differences in HR or SBP between the two groups. Conclusion: During down-fracture of Le Fort I osteotomy, sympathetic nerve activity was predominant with propofol anesthesia, and parasympathetic nerve activity was predominant with remimazolam anesthesia.

The Difference of Standardized Uptake Value on PET-CT According to Change of CT Parameters (PET-CT에서 CT의 관전압 및 관전류에 따른 SUV값의 변화)

  • Shin, Gyoo-Seul;Dong, Kyeong-Rae
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2007
  • Purpose : There is difference between PET and PET/CT method on their transmission image for attenuation correction. The CT image is used for attenuation correction on PET/CT and the parameters of CT may be affected on PET image. We performed the phantom study to evaluate whether the change of CT parameters(kilovolts peak and milliampere) affect standardized uptake value(SUV) on PET image. Material and Method: The data spectrum lung phantom containing diluted [18F]fluorodeoxyglucose ([18F]FDG) solution(1.909 mCi for phantom 1, $913\;{\mu}Ci$ for phantom 2) was used. The CT images of phantom were acquired with varying parameters (80, 100, 120, 140 for kVp, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 for mA). The PET images were reconstructed with the each CT images and SUVs were compared. Result : The SUVs of phantom 1 reconstructed with each 80, 100, 120 and 140 kVp showed $12.26{\pm}0.009$, $12.27{\pm}0.005$, $12.27{\pm}0.006$ and $12.27{\pm}0.009$, respectively. The SUVs of phantom 2 revealed $4.52{\pm}0.043$, $4.53{\pm}0.004$, $4.52{\pm}0.007$ and $4.52{\pm}0.005$ with elevation of voltage. There was no statistically significant difference of SUVs between groups based on various kVp. Also SUVs of phantom 1 and 2 showed no significant change with elevation of milliampere in CT parameter. Conclusion : The parameters of CT did not significantly affect SUV on PET image in our study. Therefore we can apply various parameters of CT appropriated for clinical conditions without significant change of SUV on PET CT image.

  • PDF

The Evaluation of TrueX Reconstruction Method in Low Dose (저선량에서의 TrueX 재구성 방법에 의한 유용성 평가)

  • Oh, Se-Moon;Kim, Kye-Hwan;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.83-87
    • /
    • 2011
  • Purpose: Recently in diagnostics area PET/CT is using a variety of areas including oncology, as well as in cardiology, neurology, etc. While increasing in the importance of PET/CT, there are various researches in the image quality related to reconstruction method. We compared and tested Iterative 2D Reconstruction Method with True X Reconstruction method by Siemens through phantom experiment, so we can see increasing of clinical usefulness of PET/CT. Materials and Methods: We measured contrast ratio and FWHM due to evaluating images on dose and experiment using Biograph 40 True Point PET/CT (Siemens, Germany). Getting a result of contrast ratio and FWHM, we used NEMA IEC PET body phantom (Data Spectrum Corp.) and capillary tube. We used the current TrueX and the previous Iterative 2D algorithm for all images which have 10 minutes long. Also, a clinical suitability of parameter for Iterative 2D and a recommended parameter by Siemens for True X are applied to the experiment. Results: We tested FWHM using capillary tube. As a result, TrueX was less than Iterative 2D. Also, the differences of FWHM get bigger in low dose. On the other hand, we tested contrasts ratio using NEMA IEC PET body phantom. As a result, TrueX was better aspect than Iterative 2D. However, there was no difference in dose. Conclusion: In this experiment, TrueX get higher results of contrast ratio and spatial resolution than Itertive 2D through experiment. Also, in the reconstruction result through TrueX, TrueX had better aspect of resolution than Iterative 2D in low dose. However, contrast ratio had no specific difference. In other words, TrueX reconstruction method in PET/CT had higher clinical value in use because TrueX can reduce exposure of patient and had a better quality of screen.

  • PDF

Comparison of Horizontal and Vertical Noise Power Spectrum in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료 시 전자포털 영상장치를 이용한 잡음전력스펙트럼 수평 및 수직 측정비교)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.171-176
    • /
    • 2016
  • The quality assurance (QA) is very important for diagnostic field and radiation therapy field to evaluate the characteristic of devices. The purpose of this study was to compare different NPS methodologies results which are measuring NPS with regard to horizontal and vertical directions by using megavoltage X-ray energies. The NPS evaluation methods were applied to the International Electro-technical Commission standard (IEC 62220-1). The electronic portal imaging devices (EPID) devices such as Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT and Varian Clinac$^R$ iX aS1000 were used. NPS data were expressed by corresponding each frequency about average of noise value corresponding the each frequency, and NPS were evaluated quantitatively by totaling up the noise values of average frequency which are on horizontal and vertical directions. In NPS results for Elekta iViewGT, NPS of horizontal and vertical by using 4 methods were indicated the difference of 3~5% between horizontal and vertical direction. In the results of Siemens BEAMVIEW$^{PLUS}$ and Varian Clinac$^R$ iX aS1000, the NPS of horizontal and vertical direction were indicated the difference of 15% when averaging the whole values. This study were evaluated the NPS of each devices by totaling up the noise values of average frequency which are on horizontal and vertical directions suggesting the quantitative evaluation method using the data.

NMR Spectroscopy and Mass Spectrometry of Phenylethanol Galactoside synthesized using Escherichia coli 𝛽-Galactosidase (대장균 베타-갈락토시데이즈를 이용하여 합성된 Phenylethanol Galactoside의 NMR Spectroscopy 및 Mass spectrometry)

  • Lee, Hyang-Yeol;Jung, Kyung-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.1323-1329
    • /
    • 2020
  • To characterize the molecular structure of PhE-gal synthesized using Escherichia coli 𝛽-gal, NMR (1H- and 13C-) spectroscopy and mass spectrometry of PhE-gal were conducted. 1H NMR spectrum of PhE-gal showed multiple peaks corresponding to the galactosyl group, which is an evidence of galactosylation on 2-phenylethanol (PhE). Downfield proton peaks at 𝛿H 7.30~7.21 ppm showed the presence of aromatic protons of PhE as well as benzyl CH2 protons at 𝛿H 2.88 ppm. Up field proton peaks at 𝛿H 4.31 ppm, 4.07 ppm and multiple peaks from 𝛿H 3.86~3.38 ppm are indicative of galactocylation on PhE. 13C NMR spectrum revealed the presence of 12 carbons suggestive of PhE-gal. Among 12 carbon peaks from PhE-gal, the four peaks at 138.7, 129.0, 128.6 and 126.5 were assigned aromatic carbons in the phenyl ring. Three peaks at 129.0, 128.6 and 126.5 showed high intensities, indicating CH aromatic carbons. 13C NMR data of PhE-gal showed 6 monosaccharide peaks from galactose and 2 peaks from aliphatic chain of PhE, indicating that PhE-gal was galactosyl PhE. The mass value (sodium adduct ion of PhE-gal, m/z = 307.1181) from mass spectrometry analysis of PhE-gal, and 1H and 13C NMR spectral data were in good agreement with the expecting structure of PhE-gal. We are expecting that through future study it will eventually be able to develop a new additive with low cytotoxicity.

Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System (GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구)

  • Lee, Chung-Il;Shin, Jae-Won;Shin, Hun-Joo;Jung, Jae-Yong;Kim, Yon-Lae;Min, Jeong-Hwan;Hong, Seung-Woo;Chung, Su-Mi;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Cyberknife with small field size is more difficult and complex for dosimetry compared with conventional radiotherapy due to electronic disequilibrium, steep dose gradients and spectrum change of photons and electrons. The purpose of this study demonstrate the usefulness of Geant4 as verification tool of measurement dose for delivering accurate dose by comparing measurement data using the diode detector with results by Geant4 simulation. The development of Monte Carlo Model for Cyberknife was done through the two-step process. In the first step, the treatment head was simulated and Bremsstrahlung spectrum was calculated. Secondly, percent depth dose (PDD) was calculated for six cones with different size, i.e., 5 mm, 10 mm, 20 mm, 30 mm, 50 mm and 60 mm in the model of water phantom. The relative output factor was calculated about 12 fields from 5 mm to 60 mm and then it compared with measurement data by the diode detector. The beam profiles and depth profiles were calculated about different six cones and about each depth of 1.5 cm, 10 cm and 20 cm, respectively. The results about PDD were shown the error the less than 2% which means acceptable in clinical setting. For comparison of relative output factors, the difference was less than 3% in the cones lager than 7.5 mm. However, there was the difference of 6.91% in the 5 mm cone. Although beam profiles were shown the difference less than 2% in the cones larger than 20 mm, there was the error less than 3.5% in the cones smaller than 20 mm. From results, we could demonstrate the usefulness of Geant4 as dose verification tool.

Assessment and Comparison of SUVs of Three Different PET/CT Scanners (장비에 따른 SUV의 차이와 이에 관한 고찰)

  • Kim, Tae-Yeob;Lim, Jung-Jin;Lee, Hong-Jae;Kim, Hyun-Joo;Kim, Joong-Hyun;Lee, Jae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.34-38
    • /
    • 2011
  • Purpose: The SUV is a widely used semi-quantitative index in PET for the estimation of radio-tracer accumulation in VOI. In this study, SUVs from three different PET/CT scanners were assessed, and differences between SUVs were evaluated. Materials and Methods: The PET/CT scanners which were assessed in this study were GEMINI, GEMINI TF 64 (Philips) and Biograph True Point True V 40 (Siemens). The NEMA PET phantom (Data Spectrum Corp., USA) was used to evaluate SUVs. The NEMA PET phantom has6.8 kg weight and three hot inserts. Two different activity distributions for the background and inserts were tested. The activity ratio were 3.7:3.7:7.4:11.1 MBq (1:1:2:3) and 1.85:7.4:9.25:11.1MBq (1:4:5:6) for each of background, insert 1, insert 2 and insert 3. Acquisition time was 2 minutes per bed position and NEMA PET phantom could be covered by two bed positions for all PET/CT scanners. The SUVs from each PET/CT scanner were compared with calculated true value. Results: For both activity ratios, all scanners showed similar results. The differences between each scanner were insignificant. Each scanner showed 91.2%, 85.9% and 87.2% of true SUV for GEMINI, GEMINI TF 64, Biograph True Point TrueV, respectively. Conclusion: For all scanners, SUVs were slightly lower than true value. However, the difference between scanners was insignificant. The SUVs from these scanners would be clinically meaningful if their consistent underestimation is kept in mind.

  • PDF

The study of nondestructive method for measuring the acidity of the recent record paper in Hanji by using FT-NIR spectroscopy and Integrating sphere (푸리에 변환 근적외선 분광분석기(FT-NIR)와 적분구를 이용한 근대 한지 기록물의 산성도 비파괴 평가방법에 대한 연구)

  • Shin, Yong-Min;Park, Soung-Be;Kim, Chan-Bong;Lee, Seong-Uk;Cho, Won-Bo;Kim, Hyo-Jin
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2011.10a
    • /
    • pp.255-269
    • /
    • 2011
  • The purpose of study has to analyze with non destructive method for researching the tool that could be measured with the status of record written on Hanji speedily. Because the original record should be destructed for analyzing with previous method in the case of the paper record, it was to develop the tool based on non destructive method for overcoming such limit. The study was used with FT NIR (Fourier transform NIR) for analyzing the Hanji for being written and preserved. The FT NIR spectrometer that of NIR spectrometer has the better performance of precision and accuracy than dispersive NIR spectrometer was used. Also the wavelength of FT-NIR was measured with 12,500 to 4,000 $cm^{-1}$, and the integrating sphere as diffuse reflectance type was used for analyzing Hanji. The moisture and acidity (pH) of chemical factors as quality evaluated factor of Hanji was studied for the correlation of NIR spectrum. And then The NIR spectrum was pretreated for showing the coefficients of optimum correlation. MSC and First derivative of Savitzky - Golay was used as pretreated method, and the coefficients of optimum correlation were shown by PLSR(Partial least square regression). And the coefficients of optimum correlation were calculated by PLSR(Partial least square regression). The correlation coefficients of acidity had 0.92 on NIR spectra without pretreatment. Also the SEP of acidity was 0.24. And then The NIR spectra with pretreatment would have more good correlation coefficients ($R^2=0.98$) and more good SEP(=019) on acidity. Therefore the data of correlation coefficients ($R^2$) and SEP with pretreatment was shown to be superior. And NIR spectra data of first derivative had best linearity on the correlation coefficients ($R^2=0.99$) and also SEP(=0.45) was superior. Therefore the correlation coefficients and SEP of first derivative had better than those of NIR spectra of no pretreatment. As such result, it was possible to evaluate the record status of Hanji speedily with integrated sphere and NIR analyzer as non destructive method.

  • PDF