• Title/Summary/Keyword: Spectrum data

Search Result 2,069, Processing Time 0.031 seconds

Reliability Design Analysis for Underwater Buriend PBA Based on PoF (고장물리 기반 수중 매설형 PBA에 대한 신뢰성 설계 연구)

  • Kim, Ji-Young;Lee, Ki-Won;Yoon, Hong-Woo;Lee, Seung-Jin;Heo, Jun-Ki;Kwon, Hyeong-Ahn
    • Journal of Applied Reliability
    • /
    • v.17 no.4
    • /
    • pp.280-288
    • /
    • 2017
  • Purpose: PBA buried in underwater requires high reliability because of its mission critical characteristic and harsh operational environment during its life cycle. Therefore, various reliability improvement activities are necessary. The defect on PBA manufacturing process have been studied, as a result, many activities and standards have been presented. However, there are less studies regarding failure pattern on physical features based on design. In this paper, we studied a possible failure patten based on physical features that is related with manufacturing process of PBA. And reliability improvement design based on PoF (Physical of Failure) were intruduced in this paper. Methods: A reliability prediction simulation were performed on the components A and B of the H system using Sherlock Software which is a PoF commercial tool from DFR solution. Solder fatigue and PTH fatigue analysis based on thermal cycling profiles and random vibration was analyzed on three earthquake response spectrum. Result: It was validated that life time and reliability improvement design through solder fatigue and PTH fatigue analysis in case of component. For compoenet B, random vibration fatigue was additionally analyzed and validated reliability for earthquakes profile. Conclusion: In design stage prior to manufacturing, PoF can be analyzed, and it is possible to make a reliability improvement/validated design using design data. This study can be applied in every design step and contribute to make more stable development product.

Noise Exposure Assessment in a Dental School

  • Choosong, Thitiworn;Kaimook, Wandee;Tantisarasart, Ratchada;Sooksamear, Puwanai;Chayaphum, Satith;Kongkamol, Chanon;Srisintorn, Wisarut;Phakthongsuk, Pitchaya
    • Safety and Health at Work
    • /
    • v.2 no.4
    • /
    • pp.348-354
    • /
    • 2011
  • Objectives: This cross-sectional study was performed in the Dental School of Prince of Songkla University to ascertain noise exposure of dentists, dental assistants, and laboratory technicians. A noise spectral analysis was taken to illustrate the spectra of dental devices. Methods: A noise evaluation was performed to measure the noise level at dental clinics and one dental laboratory from May to December 2010. Noise spectral data of dental devices were taken during dental practices at the dental services clinic and at the dental laboratory. A noise dosimeter was set following the Occupational Safety and Health Administration criteria and then attached to the subjects' collar to record personal noise dose exposure during working periods. Results: The peaks of the noise spectrum of dental instruments were at 1,000, 4,000, and 8,000 Hz which depended on the type of instrument. The differences in working areas and job positions had an influence on the level of noise exposure (p < 0.01). Noise measurement in the personal hearing zone found that the laboratory technicians were exposed to the highest impulsive noise levels (137.1 dBC). The dentists and dental assistants who worked at a pedodontic clinic had the highest percent noise dose (4.60 ${\pm}$ 3.59%). In the working areas, the 8-hour time-weighted average of noise levels ranged between 49.7-58.1 dBA while the noisiest working area was the dental laboratory. Conclusion: Dental personnel are exposed to noise intensities lower than occupational exposure limits. Therefore, these dental personnel may not experience a noise-induced hearing loss.

Visualizing the distributions and spatiotemporal changes of metabolites in Panax notoginseng by MALDI mass spectrometry imaging

  • Sun, Chenglong;Ma, Shuangshuang;Li, Lili;Wang, Daijie;Liu, Wei;Liu, Feng;Guo, Lanping;Wang, Xiao
    • Journal of Ginseng Research
    • /
    • v.45 no.6
    • /
    • pp.726-733
    • /
    • 2021
  • Background: Panax notoginseng is a highly valued medicinal herb used widely in China and many Asian countries. Its root and rhizome have long been used for the treatment of cardiovascular and hematological diseases. Imaging the spatial distributions and dynamics of metabolites in heterogeneous plant tissues is significant for characterizing the metabolic networks of Panax notoginseng, and this will also provide a highly informative approach to understand the complex molecular changes in the processing of Panax notoginseng. Methods: Here, a high-sensitive MALDI-MS imaging method was developed and adopted to visualize the spatial distributions and spatiotemporal changes of metabolites in different botanical parts of Panax notoginseng. Results: A wide spectrum of metabolites including notoginsenosides, ginsenosides, amino acids, dencichine, gluconic acid, and low-molecular-weight organic acids were imaged in Panax notoginseng rhizome and root tissues for the first time. Moreover, the spatiotemporal alterations of metabolites during the steaming of Panax notoginseng root were also characterized in this study. And, a series of metabolites such as dencichine, arginine and glutamine that changed with the steaming of Panax notoginseng were successfully screened out and imaged. Conclusion: These spatially-resolved metabolite data not only enhance our understanding of the Panax notoginseng metabolic networks, but also provide direct evidence that a serious of metabolic alterations occurred during the steaming of Panax notoginseng.

A Study on Noise Cancellation Model in VLC Channel caused by High Luminance of RGB LED, Using Band-Pass Optical Filters (밴드패스 광 필터를 이용한 VLC 채널의 고휘도 RGB LED 잡음 제거 모델에 관한 연구)

  • Nugmanov, Said;Khudaybergenov, Timur;Cha, Jae Sang
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.1
    • /
    • pp.83-90
    • /
    • 2019
  • LED lighting is spreading on the strength of LED lighting, and various government policies are being implemented. VLC research which is a wireless communication technology using lighting has been actively conducted, and it has been proven through many studies that a general LED light source such as a high-speed data transmitter can be used. But from now on, one of the main problems is the noise from side lights, which can be compared to the noise of radio broadcasts. So in this paper, we proposed a noise canceling model to remove the interference of ambient light by using an optical filter for a detachable VLC channel. In order to verify the proposed model, various high brightness RGB LED modules were used for comparative analysis. In addition, the applicability was verified through experiments using High Luminance LED lighting which is applied in real life.

Conservation of Wooden Furniture in Presidential Archives of National Archives of Korea (국가기록원 대통령기록관 소장 목가구 보존처리)

  • Lee, Kwang-Hee;Park, Jung-Hae;Kim, Su-Chul
    • Journal of Conservation Science
    • /
    • v.35 no.3
    • /
    • pp.245-251
    • /
    • 2019
  • In this paper, conservation treatment processes for the wooden furniture in the Presidential Archives are introduced. Conservation treatment strategies for modern wooden cultural heritage have been increasingly studied. The current study uses materials similar to those used by the existing conservation treatment method. Material analysis showed that the chair(Lee136-2) and desk(Yun37) in the Presidential Archives are made of Dipterocarpaceae, and both are coated with two layers of varnishing. FT-IR analysis showed that the varnish has a similar spectrum to that of a nitrocellulose-based lacquer(Lee136-2) and top coat(Yun37) and confirmed that a synthetic material was used. Pollutants had adhered to the surface of the wooden furniture and it was also in structurally unstable condition because of cracks and damage to the varnish and wood. Therefore, a conservation treatment was carried out to restore the damaged areas to their original appearance using similar kinds of materials, based on data obtained by materials analysis.

Develop physical layer analysis algorithm for OFDMA signal based IEEE 802.16e (IEEE 802.16e 기반 OFDMA 물리층 분석 알고리즘 연구)

  • Jang, Min-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.342-349
    • /
    • 2019
  • We describe and anlayzes the methodology and implementation results of H / W configuration and signal characteristics analysis algorithm for analyzing equipment for analyzing OFDMA physical layer based on 802.16e. Recently, demand for signal analysis of instruments that analyze these signals with the development of digital communication signals is rapidly increasing. Accordingly, it is necessary to develop signal analysis equipment capable of analyzing characteristics of a broadband communication signal using a wideband digital signal processing module. In this paper, we have studied the basic theory of OFDMA in order to devise a device capable of analyzing characterisitcs of broadband communication signals. Second, the structure of OFDMA transmitter/receiver was examined. Third, a wideband digitizer was implemented. we design Wimax signal analysis algorithm based on OFDMA among broadband communication methods and propose Wimax physical layer analysis S/W implementation through I, Q signals. The IF downconverter used the receiver module and the LO generation module of the spectrum analyzer. Quantitative analysis result is obtained through the algorithm of Wimax signal analysis by I, Q data.

Enhancing the performance of a long-life modified CANDLE fast reactor by using an enriched 208Pb as coolant

  • Widiawati, Nina;Su'ud, Zaki;Irwanto, Dwi;Permana, Sidik;Takaki, Naoyuki;Sekimoto, Hiroshi
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.423-429
    • /
    • 2021
  • The investigation of the utilization of enriched 208Pb as a coolant to enhance the performance of a long-life fast reactor with a Modified CANDLE (Constant Axial shape of Neutron flux, nuclide densities, and power shape During Life of Energy production) burnup scheme has performed. The analyzes were performed on a reactor with thermal power of 800 MegaWatt Thermal (MWTh) with a refueling process every 15 years. Uranium Nitride (enriched 15N), 208Pb, and High-Cr martensitic steel HT-9 were employed as fuel, coolant, and cladding materials, respectively. One of the Pb-nat isotopes, 208Pb, has the smallest neutron capture cross-section (0.23 mb) among other liquid metal coolants. Furthermore, the neutron-producing cross-section (n, 2n) of 208Pb is larger than sodium (Na). On the other hand, the inelastic scattering energy threshold of 208Pb is the highest among Na, natPb, and Bi. The small inelastic scattering cross-section of 208Pb can harden the neutron energy spectrum. Therefore, 208Pb is a better neutron multiplier than any other liquid metal coolant. The excess neutrons cause more production than consumption of 239Pu. Hence, it can reduce the initial fuel loading of the reactor. The selective photoreaction process was developing to obtain enriched 208Pb. The neutronic was calculated using SRAC and JENDL 4.0 as a nuclear data library. We obtained that the modified CANDLE reactor with enriched 208Pb as coolant and reflector has the highest k-eff among all reactors. Meanwhile, the natPb cooled reactor has the lowest k-eff. Thus, the utilization of the enriched 208Pb as the coolant can reduce reactor initial fuel loading. Moreover, the enriched 208Pb-cooled reactor has the smallest power peaking factor among all reactors. Therefore, the enriched 208Pb can enhance the performance of a long-life Modified CANDLE fast reactor.

Uncertainty analysis of BRDF Modeling Using 6S Simulations and Monte-Carlo Method

  • Lee, Kyeong-Sang;Seo, Minji;Choi, Sungwon;Jin, Donghyun;Jung, Daeseong;Sim, Suyoung;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.1
    • /
    • pp.161-167
    • /
    • 2021
  • This paper presents the method to quantitatively evaluate the uncertainty of the semi-empirical Bidirectional Reflectance Distribution Function (BRDF) model for Himawari-8/AHI. The uncertainty of BRDF modeling was affected by various issues such as assumption of model and number of observations, thus, it is difficult that evaluating the performance of BRDF modeling using simple uncertainty equations. Therefore, in this paper, Monte-Carlo method, which is most dependable method to analyze dynamic complex systems through iterative simulation, was used. The 1,000 input datasets for analyzing the uncertainty of BRDF modeling were generated using the Second Simulation of a Satellite Signal in the Solar Spectrum (6S) Radiative Transfer Model (RTM) simulation with MODerate Resolution Imaging Spectroradiometer (MODIS) BRDF product. Then, we randomly selected data according to the number of observations from 4 to 35 in the input dataset and performed BRDF modeling using them. Finally, the uncertainty was calculated by comparing reproduced surface reflectance through the BRDF model and simulated surface reflectance using 6S RTM and expressed as bias and root-mean-square-error (RMSE). The bias was negative for all observations and channels, but was very small within 0.01. RMSE showed a tendency to decrease as the number of observations increased, and showed a stable value within 0.05 in all channels. In addition, our results show that when the viewing zenith angle is 40° or more, the RMSE tends to increase slightly. This information can be utilized in the uncertainty analysis of subsequently retrieved geophysical variables.

A Coexistence Study of Low-power Short-range Wireless Network and Incumbent Service in the 6GHz band (6GHz 비면허 대역의 저전력 근접 무선통신과 기존 무선업무와의 공존 연구)

  • Kim, Seung-Nam;Lee, Il-Kyoo;Sung, Joo-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.8
    • /
    • pp.1074-1081
    • /
    • 2021
  • It has recently been noticed that the headway of unlicensed wireless technology is necessary as user's demands of wireless tech increase and the development of high-speed data service by using low-power short-range wireless network is needed. Hence, it is inevitable to study sharing and coexistence for broadband spectrum of diverse unlicensed application with wide bandwidth. In this paper, an interference examination between unlicensed WiFi (Wireless Fidelity) in the 6GHz and OB (Outside Broadcasting) system which is an incumbent service in the same frequency band was conducted and it suggests separation distance for the coexistence. Thus, MCL (Minimum Coupling Loss) and MC (Monte Carlo) methods were used to set up interference scenarios for the interference analysis and compute the separation distance between two systems according to the same frequency band and frequency separation.

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.