DOI QR코드

DOI QR Code

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan (Engineering Research Center of Nuclear Technology Application (East China University of Technology), Ministry of Education) ;
  • Zhang, Xiongjie (Engineering Research Center of Nuclear Technology Application (East China University of Technology), Ministry of Education) ;
  • Meng, Xiangting (Engineering Research Center of Nuclear Technology Application (East China University of Technology), Ministry of Education) ;
  • Wang, Bao (Engineering Research Center of Nuclear Technology Application (East China University of Technology), Ministry of Education) ;
  • Wang, Dongyang (Engineering Research Center of Nuclear Technology Application (East China University of Technology), Ministry of Education) ;
  • Zhou, Pengfei (Engineering Research Center of Nuclear Technology Application (East China University of Technology), Ministry of Education) ;
  • Wang, Renbo (Engineering Research Center of Nuclear Technology Application (East China University of Technology), Ministry of Education) ;
  • Tang, Bin (Engineering Research Center of Nuclear Technology Application (East China University of Technology), Ministry of Education)
  • Received : 2021.09.14
  • Accepted : 2021.12.15
  • Published : 2022.06.25

Abstract

A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

Keywords

Acknowledgement

This work was supported by Defense Industrial Technology Development Program of China (No. JCKY2018401C001), Natural Science Foundation of Jiangxi Province (No. 20192BAB202009) and Joint Innovation Fund of China National Uranium Co., Ltd. and State Key Laboratory of Nuclear Resources and Environment (No. NRE2021-03).

References

  1. S. Saxena, A.I. Hawari, Investigation of FPGA based real time adaptive digital pulse shaping for high count rate applications, IEEE Trans. Nucl. Sci. 64 (2017) 1733-1738. https://doi.org/10.1109/TNS.2017.2692219
  2. G.Q. Zeng, J. Yang, T.Y. Hu, L.Q. Ge, X.P. Ouyang, Q.X. Zhang, Y. Gu, Baseline restoration technique based on symmetrical zero-area trapezoidal pulse shaper, Nucl. Instrum. Methods A. 858 (2017) 57-61. https://doi.org/10.1016/j.nima.2017.03.049
  3. J. Yu, J.B. Zhou, Y. Liu, X.G. Tuo, M. Wang, X. Zhu, Pile-up pulse continuous zone reject method, Appl. Radiat. Isot. 165 (2020) 109319, https://doi.org/10.1016/j.apradiso.2020.109319.
  4. H.Q. Zhang, B. Tang, H.X. Wu, Z.D. Li, Study of Sallen-Key digital filters in nuclear pulse signal processing, Nucl. Sci. Tech. 30 (2019) 145, https://doi.org/10.1007/s41365-019-0679-y.
  5. J.B. Zhou, Y. Liu, X. Hong, J. Zhou, Y.J. Ma, M. Wang, Y.C. Hu, B. Chen, A.Z. Yue, Trapezoidal pulse shaping for pile-up pulse identification in X-ray spectrometry, Chin. Phys. C 39 (2015), https://doi.org/10.1088/1674-1137/39/6/068201, 068201.
  6. D.C. Li, Z.G. Ren, L. Yang, Z. Qi, X.T. Meng, B.T. Hu, A novel acquisition method for nuclear spectra based on pulse area analysis, Chin. Phys. C 39 (2015), 046201, https://doi.org/10.1088/1674-1137/39/4/046201.
  7. E.L. Chen, C.Q. Feng, S.B. Liu, C.F. Ye, D.D. Jin, J. Lian, H.J. Hu, Readout electronics for a high-resolution soft X-ray spectrometer based on silicon drift detector, Nucl. Sci. Tech. 28 (2017) 14, https://doi.org/10.1007/s41365-016-0160-0.
  8. F. Fahiman, M. Kafaee, A. Moussavi-Zarandi, M. Fahiman, Efficient digital implementation of signal processing algorithms in state-of-the-art field-programmable gate arrays for gamma-ray spectroscopy, Nucl. Technol. 187 (2014) 69-81. https://doi.org/10.13182/nt13-65
  9. A. Garcia-Duran, V.M. Hernandez-Davila, H.R. Vega-Carrillo, O.O. Ordaz-Garcia, I. Bravo-Munoz, R. Solis-Robles, FPGA embedded multichannel analyzer, Appl. Radiat. Isot. 141 (2018) 282-287. https://doi.org/10.1016/j.apradiso.2018.07.017
  10. V.E. Sani, M. Mohamadian, I. Alizadeh, H. Afarideh, Application of computers in experiments design, building and evaluation of a new generation of multichannel analyzers implemented in Xilinx ZYNQ-7020, Instrum. Exp. Tech. 62 (2019) 771-777. https://doi.org/10.1134/s002044121906006x
  11. Xilinx, Zynq-7000 SoC Technical Reference Manual. https://www.xilinx.com/support/documentation/user_guides/ug585-Zynq-7000-TRM.pdf.
  12. M. Angelone, R. Pilotti, F. Stacchi, M. PiIlon, A. Klix, P. Raj, S. Loreti, G. Pagano, Performance test of radiation detectors developed for ITER-TBM, Fusion Eng. Des. 136 (2018) 1386-1390. https://doi.org/10.1016/j.fusengdes.2018.05.018
  13. G.Q. Zeng, C.H. Hu, S.L. Wei, J. Yang, Q. Li, L.Q. Ge, C.J. Tan, Research and development of a high-performance differential-hybrid charge sensitive preamplifier, Appl. Radiat. Isot. 120 (2017) 95-100. https://doi.org/10.1016/j.apradiso.2016.12.006
  14. S.N. Ahmed, Signal processing, in: S.N. Ahmed (Ed.), Physics and Engineering of Radiation Detection, Elsevier Inc., Sudbury, 2015, pp. 477-540.
  15. J. Pechousek, D. Konecny, P. Novak, L. Kouril, P. Kohout, C. Celiktas, M. Vujtek, Software emulator of nuclear pulse generation with different pulse shapes and pile-up, Nucl. Instrum. Methods A. 828 (2016) 81-85. https://doi.org/10.1016/j.nima.2016.05.032
  16. D. Fasino, A. Fazzi, A Gauss-Newton iteration for total least squares problems, Bit Numer. Math. 58 (2018) 281-299. https://doi.org/10.1007/s10543-017-0678-5
  17. Z. Guzik, S. Borsuk, K. Traczyk, M. Plominski, TUKAN-an 8K pulse height analyzer and multi-channel scaler with a PCI or a USB interface, IEEE Trans. Nucl. Sci. 53 (2006) 231-235. https://doi.org/10.1109/TNS.2006.869819
  18. M. Dambacher, A. Zwerger, A. Fauler, C. Disch, U. Stohlker, M. Fiederle, Development of the gamma-ray analysis digital filter multi-channel analyzer (GMCA), Nucl. Instrum. Methods A. 652 (2011) 445-449. https://doi.org/10.1016/j.nima.2011.02.020
  19. Xilinx, AXI Reference Guide. https://www.xilinx.com/support/documentation/ip_documentation/axi_ref_guide/latest/ug761_axi_reference_guide.pdf.
  20. Datasheet AD8138, Low Distortion and Differential ADC Driver. https://www.analog.com/media/en/technical-documentation/data-sheets/AD8138.pdf.
  21. Datasheet AD9238, 12-Bit 65 MSPS Dual A/D Converter. https://www.analog.com/media/en/technical-documentation/data-sheets/AD9238.pdf.
  22. T. Marchais, B. Perot, C. Carasco, J.L. Ma, P.G. Allinei, H. Toubon, R. Goupillou, J. Collot, Characterization of uranium ore samples by HPGe gamma-ray spectroscopy, IEEE Trans. Nucl. Sci. 67 (2020) 654-661. https://doi.org/10.1109/tns.2020.2966824
  23. A. Virgilio, D.A. Goncalves, T. McSweeney, J.A.G. Neto, J.A. Nobrega, G.L. Donati, Multi-energy calibration applied to atomic spectrometry, Anal. Chim. Acta 982 (2017) 31-36. https://doi.org/10.1016/j.aca.2017.06.040
  24. Y.E. Lavrukhin, O. V Rumyantsev, A.P. Borisov, D.S. Grozdov, S.A. Korolev, Monitoring of Pb-214 and Bi-214 activity with the askro spectrometric channel, At. Energy. 118 (2015) 431-435. https://doi.org/10.1007/s10512-015-0019-1