Acknowledgement
This work was supported by Defense Industrial Technology Development Program of China (No. JCKY2018401C001), Natural Science Foundation of Jiangxi Province (No. 20192BAB202009) and Joint Innovation Fund of China National Uranium Co., Ltd. and State Key Laboratory of Nuclear Resources and Environment (No. NRE2021-03).
References
- S. Saxena, A.I. Hawari, Investigation of FPGA based real time adaptive digital pulse shaping for high count rate applications, IEEE Trans. Nucl. Sci. 64 (2017) 1733-1738. https://doi.org/10.1109/TNS.2017.2692219
- G.Q. Zeng, J. Yang, T.Y. Hu, L.Q. Ge, X.P. Ouyang, Q.X. Zhang, Y. Gu, Baseline restoration technique based on symmetrical zero-area trapezoidal pulse shaper, Nucl. Instrum. Methods A. 858 (2017) 57-61. https://doi.org/10.1016/j.nima.2017.03.049
- J. Yu, J.B. Zhou, Y. Liu, X.G. Tuo, M. Wang, X. Zhu, Pile-up pulse continuous zone reject method, Appl. Radiat. Isot. 165 (2020) 109319, https://doi.org/10.1016/j.apradiso.2020.109319.
- H.Q. Zhang, B. Tang, H.X. Wu, Z.D. Li, Study of Sallen-Key digital filters in nuclear pulse signal processing, Nucl. Sci. Tech. 30 (2019) 145, https://doi.org/10.1007/s41365-019-0679-y.
- J.B. Zhou, Y. Liu, X. Hong, J. Zhou, Y.J. Ma, M. Wang, Y.C. Hu, B. Chen, A.Z. Yue, Trapezoidal pulse shaping for pile-up pulse identification in X-ray spectrometry, Chin. Phys. C 39 (2015), https://doi.org/10.1088/1674-1137/39/6/068201, 068201.
- D.C. Li, Z.G. Ren, L. Yang, Z. Qi, X.T. Meng, B.T. Hu, A novel acquisition method for nuclear spectra based on pulse area analysis, Chin. Phys. C 39 (2015), 046201, https://doi.org/10.1088/1674-1137/39/4/046201.
- E.L. Chen, C.Q. Feng, S.B. Liu, C.F. Ye, D.D. Jin, J. Lian, H.J. Hu, Readout electronics for a high-resolution soft X-ray spectrometer based on silicon drift detector, Nucl. Sci. Tech. 28 (2017) 14, https://doi.org/10.1007/s41365-016-0160-0.
- F. Fahiman, M. Kafaee, A. Moussavi-Zarandi, M. Fahiman, Efficient digital implementation of signal processing algorithms in state-of-the-art field-programmable gate arrays for gamma-ray spectroscopy, Nucl. Technol. 187 (2014) 69-81. https://doi.org/10.13182/nt13-65
- A. Garcia-Duran, V.M. Hernandez-Davila, H.R. Vega-Carrillo, O.O. Ordaz-Garcia, I. Bravo-Munoz, R. Solis-Robles, FPGA embedded multichannel analyzer, Appl. Radiat. Isot. 141 (2018) 282-287. https://doi.org/10.1016/j.apradiso.2018.07.017
- V.E. Sani, M. Mohamadian, I. Alizadeh, H. Afarideh, Application of computers in experiments design, building and evaluation of a new generation of multichannel analyzers implemented in Xilinx ZYNQ-7020, Instrum. Exp. Tech. 62 (2019) 771-777. https://doi.org/10.1134/s002044121906006x
- Xilinx, Zynq-7000 SoC Technical Reference Manual. https://www.xilinx.com/support/documentation/user_guides/ug585-Zynq-7000-TRM.pdf.
- M. Angelone, R. Pilotti, F. Stacchi, M. PiIlon, A. Klix, P. Raj, S. Loreti, G. Pagano, Performance test of radiation detectors developed for ITER-TBM, Fusion Eng. Des. 136 (2018) 1386-1390. https://doi.org/10.1016/j.fusengdes.2018.05.018
- G.Q. Zeng, C.H. Hu, S.L. Wei, J. Yang, Q. Li, L.Q. Ge, C.J. Tan, Research and development of a high-performance differential-hybrid charge sensitive preamplifier, Appl. Radiat. Isot. 120 (2017) 95-100. https://doi.org/10.1016/j.apradiso.2016.12.006
- S.N. Ahmed, Signal processing, in: S.N. Ahmed (Ed.), Physics and Engineering of Radiation Detection, Elsevier Inc., Sudbury, 2015, pp. 477-540.
- J. Pechousek, D. Konecny, P. Novak, L. Kouril, P. Kohout, C. Celiktas, M. Vujtek, Software emulator of nuclear pulse generation with different pulse shapes and pile-up, Nucl. Instrum. Methods A. 828 (2016) 81-85. https://doi.org/10.1016/j.nima.2016.05.032
- D. Fasino, A. Fazzi, A Gauss-Newton iteration for total least squares problems, Bit Numer. Math. 58 (2018) 281-299. https://doi.org/10.1007/s10543-017-0678-5
- Z. Guzik, S. Borsuk, K. Traczyk, M. Plominski, TUKAN-an 8K pulse height analyzer and multi-channel scaler with a PCI or a USB interface, IEEE Trans. Nucl. Sci. 53 (2006) 231-235. https://doi.org/10.1109/TNS.2006.869819
- M. Dambacher, A. Zwerger, A. Fauler, C. Disch, U. Stohlker, M. Fiederle, Development of the gamma-ray analysis digital filter multi-channel analyzer (GMCA), Nucl. Instrum. Methods A. 652 (2011) 445-449. https://doi.org/10.1016/j.nima.2011.02.020
- Xilinx, AXI Reference Guide. https://www.xilinx.com/support/documentation/ip_documentation/axi_ref_guide/latest/ug761_axi_reference_guide.pdf.
- Datasheet AD8138, Low Distortion and Differential ADC Driver. https://www.analog.com/media/en/technical-documentation/data-sheets/AD8138.pdf.
- Datasheet AD9238, 12-Bit 65 MSPS Dual A/D Converter. https://www.analog.com/media/en/technical-documentation/data-sheets/AD9238.pdf.
- T. Marchais, B. Perot, C. Carasco, J.L. Ma, P.G. Allinei, H. Toubon, R. Goupillou, J. Collot, Characterization of uranium ore samples by HPGe gamma-ray spectroscopy, IEEE Trans. Nucl. Sci. 67 (2020) 654-661. https://doi.org/10.1109/tns.2020.2966824
- A. Virgilio, D.A. Goncalves, T. McSweeney, J.A.G. Neto, J.A. Nobrega, G.L. Donati, Multi-energy calibration applied to atomic spectrometry, Anal. Chim. Acta 982 (2017) 31-36. https://doi.org/10.1016/j.aca.2017.06.040
- Y.E. Lavrukhin, O. V Rumyantsev, A.P. Borisov, D.S. Grozdov, S.A. Korolev, Monitoring of Pb-214 and Bi-214 activity with the askro spectrometric channel, At. Energy. 118 (2015) 431-435. https://doi.org/10.1007/s10512-015-0019-1