• Title/Summary/Keyword: Specimen type

Search Result 1,385, Processing Time 0.025 seconds

Distribution of Cathodic Protection Potential for Concrete Slab Specimens at Diverse Environmental Conditions

  • Jin, Chung-Kuk;Jeong, Jin-A
    • International Journal of Ocean System Engineering
    • /
    • v.3 no.2
    • /
    • pp.90-94
    • /
    • 2013
  • This study represents the recent laboratory results from cathodic protection (CP) system with the use of sacrificial anodes at different environmental conditions (temperature of $10^{\circ}C$ and $40^{\circ}C$). Specimens were slab type with a dimension of $500mm{\times}50mm{\times}100mm$, and concrete cover thickness were 25mm. Zinc mesh and/or bulk type anodes were installed at the center of specimen to confirm the distance that CP system has influences on the specimen to distribute uniform CP current to rebar. Two different kinds of temperature condition were applied to verify the effect of temperature. Experiments were conducted for 60 days, and the distribution of potential and current that supplied from anode to rebar was measured. From the results, CP potential was varied with time, and temperature played an important role in CP potential variations. Current was also changed with time, and current distribution could be improved by installing additional bulk type anode.

Effect of specimen geometry and specimen preparation on the concrete compressive strength test

  • Aslani, Farhad;Maia, Lino;Santos, José
    • Structural Engineering and Mechanics
    • /
    • v.62 no.1
    • /
    • pp.97-106
    • /
    • 2017
  • This paper discusses an experimental programme that was carried out to study the effects of specimen size-shape and type of moulds on the compressive strength of concrete. For this purpose, cube specimens with 150 mm dimensions, cylinder specimens with $150{\times}300mm$ dimensions, and prism specimens with $150{\times}150{\times}375mm$ dimensions were prepared. The experimental programme was carried out with several concrete compositions belonging to strength classes C20/25, C25/30, C30/37, C40/50 and C60/75. Furthermore, the test results were curve-fitted using the least squares method to obtain the new parameters for the modified size effect law.

Specimen of Storage and Analysis for Genomic Epidemiology (유전체 역학 연구를 위한 시료의 보관과 분석)

  • Lee, Kwan-Hee;Hong, Yun-Chul
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.3
    • /
    • pp.209-212
    • /
    • 2003
  • Because of advances of technologies in the field of genmic epidemiology in the recent years, specimen collection, storage and analysis became an essential part of research methodologies. DNA is now being used in epidemiologic studies to evaluate genetic risk factors and specimens other than the fresh whole blood can De used for PCR. Therefore, All nucleated cells, such as buccal swabs and urine specimens, are suitable for DNA analysis. For an unlimited source of genomic DNA, EBV transformation of lymphocytes can be used for immortalization. However, the type of specimen collected in genomic epidemiologic studies will depend on the study where the epidemiologist play a leading role for the design. We also briefly described various finds of analysis for SNP that is an essential part of the genomic epidemiology.

A Study on the Development of Test Rig for High Speed Frontal Crash and Test of Members

  • Shin-You. Kang;In-Bae. Chang;Jang, Hye-Jeong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.3
    • /
    • pp.21-27
    • /
    • 2002
  • In this paper, a simple test rig of high-speed crash for the front members of vehicles was developed for the improvement of crashworthiness of vehicle's side rail. The cart hanging the specimen is accelerated up to 35 mph by the traction wire and by the force of freely dropping weight and 1:3 accelerating pulleys. The cart with shock absorbers travels on the rail roads, so it does not transfer any additional vibration to the specimen. In order to measure the energy absorbed by the specimen when it collapse to the wall and during it deform, the two strain gage type load cells are used at the wall place. The test rig rated good to test the specimen like a side rail of vehicle as developing the vehicle's structures in the early design stage.

Deformation Pattern of the Pyramid-Core Welded Sandwich Sheet Metal in L-Bending (피라미드코어재를 갖는 접합판재의 L-굽힘가공 특성)

  • Kim, J.H.;Chung, W.J.;Cho, Y.J.;Kim, H.G.;Hong, M.J.;Yooe, J.S.;Seong, D.Y.;Yang, D.Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.316-319
    • /
    • 2008
  • The L-bending of inner-structure bonded sandwich sheet metal is examined by using a bending die attached to the material testing machine. The specimen is composed of top and bottom layers and a middle layer of pyramid-core structure and each layer is bonded by brazing. The variables chosen for experiments were clearance between punch and die, location of bend line on the specimen surface and clamping type of specimen during L-bending. Effects of these variables on deformation of specimen around die-corner radius were investigated. It was shown that the irregular shapes of recess are formed in the inner layer of bended parts and they greatly depend on working conditions.

  • PDF

A STUDY ON THE FATIGUE AND PHYSICAL PROPERTIES OF TITANIUM USED IN REMOVABLE PARTIAL DENTURES (국소의치용 티나늄의 피로도 및 물리적 성질에 관한 연구)

  • Kim Hak-Sun;Kim Kwang-Nam;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.249-267
    • /
    • 1994
  • The purpose of this study was to compare the fatigue, physical properties, flexibility and surface roughness of titanium used in removable partial dentures with those of a type IV and alloy and a cobalt- chromium alloy. Fatigue testing subjected the test specimen to rapid cycling at a given stress until failure occurred by using a small-sized, electrodynamic type bending fatigue testing machine. The S-N curves for the framework materials were generated. For tensile testing, a tensile bar as described in the ADA Specification No.14 was subjected to tensile loading until failure occurred. Load-displacement curves were generated for 18 gauge round specimen and tapered half round specimen. Then the flexibilities were calculated. The surface roughnesses were compared by analyzer. Through analyses of the data, the following conclusions were obtained. 1. The fatigue property of titanium was higher than that of a type IV gold alloy$(p\leq0.05)$, but there was no significant difference between titanium and a cobalt-chromium alloy $(p\geq0.05)$. 2. The yield strength, the ultimate tensile strength and Victors hardness of titanium were higher than those of a type IV gold alloy but lower than those of a coalt-chromium alloy$(p\leq0.05)$. 3. The percentage of elongation and reduction of area of titanium were the highest $(p\leq0.05)$. 4. The surface roughness of titanium was the greatest$(p\leq0.05)$. 5. The flexibility of titanium was lower than that of a type IV gold alloy but higher than that of a cobalt-chromium alloy$(p\leq0.05)$.

  • PDF

Oxidation Behavior of Ti Added Alumina Dispersion Strengthening Copper Alloy (티타늄이 첨가된 알루미나 분산강화 동합금의 산화물 형성 거동)

  • Joh, Hongrae;Han, Seung Zeon;Ahn, Jee Hyuk;Lee, Jehyun;Son, Young Guk;Kim, Kwang Ho
    • Korean Journal of Materials Research
    • /
    • v.25 no.4
    • /
    • pp.202-208
    • /
    • 2015
  • Alumina dispersion strengthening copper(ADSC) alloy has great potential for use in many industrial applications such as contact supports, frictional break parts, electrode materials for lead wires, and spot welding with relatively high strength and good conductivity. In this study, we investigated the oxidation behavior of ADSC alloys. These alloys were fabricated in forms of plate and round type samples by surface oxidation reaction using Cu-0.8Al, Cu-0.4Al-0.4Ti, and Cu-0.6Al-0.4Ti(wt%) alloys. The alloys were oxidized at $980^{\circ}C$ for 1 h, 2 h, and 4 h in ambient atmosphere. The microstructure was observed with an optical microscope(OM) and a scanning electron microscope(SEM) equipped with energy-dispersive X-ray spectroscopy(EDS). Characterization of alumina was carried out using a 200 kV field-emission transmission electron microscope(TEM). As a result, various oxides including Ti were formed in the oxidation layer, in addition to ${\gamma}$-alumina. The thickness of the oxidation layer increased with Ti addition to the Cu-Al alloy and with the oxidation time. The corrected diffusion equation for the plate and round type samples showed different oxidation layer thickness under the same conditions. Diffusion length of the round type specimen had a value higher than that of its plate counterpart because the oxygen concentration per unit area of the round type specimen was higher than that of the plate type specimen at the same diffusion depth.

Development of a roller supported piston type loading platen reducing the frictional restraint along the interfaces between the specimen and platens under the biaxial loading condition (이축압축 조건에서 실험체/재하판 경계면상의 마찰저항 감소를 위한 롤러 지지된 피스톤 형태의 하중재하판의 개발)

  • SaGong, Myung;Kim, Se-Chyul;Lee, J.S.;Park, Du-Hee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.3
    • /
    • pp.303-312
    • /
    • 2008
  • Multi-axial compression tests have been frequently adopted for the evaluation of material properties of rock cores and rock fracture model tests. Special care has to be applied on the boundary condition between the specimen and loading platen to draw the precise test results of the multi-axial compression tests. With the use of dry steel platen, the stress rotation will occur, due to the frictional restraint from the boundary between the specimen and loading platen. The restraint will deviate the expected test results under the conditions of the given external pressures. Various methods have been applied to reduce the side restraint along the specimen/loading platen interface. The steel brush type loading platen is one example of the attempts. In this paper, a new type of loading platen is introduced to overcome the limitation caused by the use of the brush type loading platen, which requires some internal space for the installation of the brushes. The new type of loading platen, roller supported steel piston type loading platen. is constituted of shot steel pistons which have sufficient stiffness to deliver the external pressure and the shaft type roller installed at the rear of the pistons. The pistons are designed to follow the local deformation of the specimens. In this paper, structural details of the loading platen are presented and frictional and biaxial compression tests results are shown to verify the required functions of the loading platen. Furthermore, calibration process is followed by a comparison between the test results and numerical analyses.

  • PDF

Observation of Castability of Dental DLP 3D Printer Materials (치과용 DLP 3D Printer 가공체의 주조성 관찰)

  • Song, Joon-boo;Park, Yu-jin;Choi, Sung-min
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.255-262
    • /
    • 2019
  • Purpose: Recently, the production technology of dental prosthesis using 3D Printer workpeices has been developed. However, the lack of information on the work processes and casting techniques of materials for 3D printing casting is expected to require research. Therefore, in this study, we intend to cast a Dental DLP 3D Printer workpiece, which is being commercialized, to identify its appearance and internal clearance, and to observe its castability. Methods: Castability of the 3D Printer workpiece was evaluated. The specimen is prepared in a cylindrical shape and in a 1 mm thick coping shape. The control specimen is made of wax and the experimental specimen is made of resin using two types of 3D printers. After casting, the appearance of the casting body was observed and the internal clearance of the coping was measured. Results: RP1 and RP2, cylindrical specimens, were partially cast or fin. When coping-type specimens were measured before casting, the internal clearance of PE2 was more accurate than that of PC and PE1. When coping-type specimens were measured after casting, CE1 was the most accurate in occlusal clearance and CE2n was the most accurate in axial clearance. Conclusion: 1. Exterior observations of the casting body indicated casting defects and fins. 2. Internal clearance observations show that the occlusal clearance of the castings is larger after casting, and the axial clearance of the castings is smaller after casting. 3. It is judged that the RP2 specimen is more likely to be applied for casting than the RP1 specimen.

PFC Ultrasonic Decontamination Efficiency on the Various Types of Metal Specimens (금속 시편 형태에 따른 PEC 초음파 제염 성능)

  • Won Hui-Jun;Kim Gye-Nam;Jung Chung-Hun;Park Jin-Ho;Oh Won-Zin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.293-300
    • /
    • 2005
  • Ultrasonic decontamination of the type 304 stainless steel specimen loosely contaminated with $Eu_2O_3$ powders was investigated. Decontamination factors (DFs) by the three kinds of ultrasonic media such as water, pure PFC (Pefluorocarbon, $C_7F_{16}$) and a mixed solution of $99.9\;vol\%\;PFC\;and\;0.1\;vol\%$ anionic surfactant were determined. The determined DF values were 20, 50 and 200, respectively. This significant difference in the decontamination factors for the different decontamination solution was well explained by the surface tension of the media as well as the interaction between the positively charged surface of $Eu_2O_3$ powders and the anionic surfactant. Ultrasonic decontamination behavior of the loosely contaminated metal specimens such as plate, pipe, welding specimen and crevice specimen in the mixed solution of PFC and anionic surfactant was also investigated. The contaminants were completely removed for the tested specimens except for the longest specimen. For 6-cm long pipe specimen, however, $98.5\%$ of the contaminants were removed.

  • PDF