• Title/Summary/Keyword: Spatial blurring

Search Result 49, Processing Time 0.02 seconds

Noise Removal Filter Algorithm using Spatial Weight in AWGN Environment (화소값 분포패턴과 가중치 마스크를 사용한 AWGN 제거 알고리즘)

  • Cheon, Bong-Won;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.428-430
    • /
    • 2022
  • Image processing is playing an important part in automation and artificial intelligence systems, such as object tracking, object recognition and classification, and the importance of IoT technology and automation is emphasizing as interest in automation increases. However, in a system that requires detailed data such as an image boundary, a precise noise removal algorithm is required. Therefore, in this paper, we propose a filtering algorithm based on the pixel value distribution pattern to minimize the information loss in the filtering process. The proposed algorithm finds the distribution pattern of neighboring pixel values with respect to the pixel values of the input image. Then, a weight mask is calculated based on the distribution pattern, and the final output is calculated by applying it to the filtering mask. The proposed algorithm has superior noise removal characteristics compared to the existing method and restored the image while minimizing blurring.

  • PDF

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

The Evaluation of Resolution Recovery Based Reconstruction Method, Astonish (Resolution Recovery 기반의 Astonish 영상 재구성 기법의 평가)

  • Seung, Jong-Min;Lee, Hyeong-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Kim, Joong-Hyun;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.58-64
    • /
    • 2011
  • Objective: The 3-dimensional reconstruction method with resolution recovery modeling has advantages of high spatial resolution and contrast because of its precise modeling of spatial blurring according to the distance from detector plane. The aim of this study was to evaluate one of the resolution recovery reconstruction methods (Astonish, Philips Medical), compare it to other iterative reconstructions, and verify its clinical usefulness. Materials and Methods: NEMA IEC PET body phantom and Flanges Jaszczak ECT phantom (Data Spectrum Corp., USA) studies were performed using Skylight SPECT (Philips) system under four different conditions; short or long (2 times of short) radius, and half or full (40 kcts/frame) acquisition counts. Astonish reconstruction method was compared with two other iterative reconstructions; MLEM and 3D-OSEM which vendor supplied. For quantitative analysis, the contrast ratios obtained from IEC phantom test were compared. Reconstruction parameters were determined by optimization study using graph of contrast ratio versus background variability. The qualitative comparison was performed with Jaszczak ECT phantom and human myocardial data. Results: The overall contrast ratio was higher with Astonish than the others. For the largest hot sphere of 37 mm diameter, Astonish showed about 27.1% and 17.4% higher contrast ratio than MLEM and 3D-OSEM, in short radius study. For long radius, Astonish showed about 40.5% and 32.6% higher contrast ratio than MLEM and 3D-OSEM. The effect of acquired counts was insignificant. In the qualitative studies with Jaszczak phantom and human myocardial data, Astonish showed the best image quality. Conclusion: In this study, we have found out that Astonish can provide more reliable clinical results by better image quality compared to other iterative reconstruction methods. Although further clinical studies are required, Astonish would be used in clinics with confidence for enhancement of images.

  • PDF

Compressed-sensing (CS)-based Image Deblurring Scheme with a Total Variation Regularization Penalty for Improving Image Characteristics in Digital Tomosynthesis (DTS) (디지털 단층합성 X-선 영상의 화질개선을 위한 TV-압축센싱 기반 영상복원기법 연구)

  • Je, Uikyu;Kim, Kyuseok;Cho, Hyosung;Kim, Guna;Park, Soyoung;Lim, Hyunwoo;Park, Chulkyu;Park, Yeonok
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In this work, we considered a compressed-sensing (CS)-based image deblurring scheme with a total-variation (TV) regularization penalty for improving image characteristics in digital tomosynthesis (DTS). We implemented the proposed image deblurring algorithm and performed a systematic simulation to demonstrate its viability. We also performed an experiment by using a table-top setup which consists of an x-ray tube operated at $90kV_p$, 6 mAs and a CMOS-type flat-panel detector having a $198-{\mu}m$ pixel resolution. In the both simulation and experiment, 51 projection images were taken with a tomographic angle range of ${\theta}=60^{\circ}$ and an angle step of ${\Delta}{\theta}=1.2^{\circ}$ and then deblurred by using the proposed deblurring algorithm before performing the common filtered-backprojection (FBP)-based DTS reconstruction. According to our results, the image sharpness of the recovered x-ray images and the reconstructed DTS images were significantly improved and the cross-plane spatial resolution in DTS was also improved by a factor of about 1.4. Thus the proposed deblurring scheme appears to be effective for the blurring problems in both conventional radiography and DTS and is applicable to improve the present image characteristics.

A Novel Video Copy Detection Method based on Statistical Analysis (통계적 분석 기반 불법 복제 비디오 영상 감식 방법)

  • Cho, Hye-Jeong;Kim, Ji-Eun;Sohn, Chae-Bong;Chung, Kwang-Sue;Oh, Seoung-Jun
    • Journal of Broadcast Engineering
    • /
    • v.14 no.6
    • /
    • pp.661-675
    • /
    • 2009
  • The carelessly and illegally copied contents are raising serious social problem as internet and multimedia technologies are advancing. Therefore, development of video copy detection system must be settled without delay. In this paper, we propose the hierarchical video copy detection method that estimates similarity using statistical characteristics between original video and manipulated(transformed) copy video. We rank according to luminance value of video to be robust to spacial transformation, and choose similar videos categorized as candidate segments in huge amount of database to reduce processing time and complexity. The copy videos generally insert black area in the edge of the image, so we remove rig black area and decide copy or not by using statistical characteristics of original video and copied video with center part of frame that contains important information of video. Experiment results show that the proposed method has similar keyframe accuracy to reference method, but we use less memory to save feature information than reference's, because the number of keyframes is less 61% than that of reference's. Also, the proposed method detects if the video is copied or not efficiently despite expansive spatial transformations such as blurring, contrast change, zoom in, zoom out, aspect ratio change, and caption insertion.

Adaptive Block Recovery Based on Subband Energy and DC Value in Wavelet Domain (웨이블릿 부대역의 에너지와 DC 값에 근거한 적응적 블록 복구)

  • Hyun, Seung-Hwa;Eom, Il-Kyu;Kim, Yoo-Shin
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.95-102
    • /
    • 2005
  • When images compressed with block-based compression techniques are transmitted over a noisy channel, unexpected block losses occur. In this paper, we present a post-processing-based block recovery scheme using Haar wavelet features. No consideration of the edge-direction, when recover the lost blocks, can cause block-blurring effects. The proposed directional recovery method in this paper is effective for the strong edge because exploit the varying neighboring blocks adaptively according to the edges and the directional information in the image. First, the adaptive selection of neighbor blocks is performed based on the energy of wavelet subbands (EWS) and difference of DC values (DDC). The lost blocks are recovered by the linear interpolation in the spatial domain using selected blocks. The method using only EWS performs well for horizontal and vertical edges, but not as well for diagonal edges. Conversely, only using DDC performs well diagonal edges with the exception of line- or roof-type edge profiles. Therefore, we combined EWS and DDC for better results. The proposed methods out performed the previous methods using fixed blocks.

A Study on the Pixel-Paralled Image Processing System for Image Smoothing (영상 평활화를 위한 화소-병렬 영상처리 시스템에 관한 연구)

  • Kim, Hyun-Gi;Yi, Cheon-Hee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.11
    • /
    • pp.24-32
    • /
    • 2002
  • In this paper we implemented various image processing filtering using the format converter. This design method is based on realized the large processor-per-pixel array by integrated circuit technology. These two types of integrated structure are can be classify associative parallel processor and parallel process DRAM(or SRAM) cell. Layout pitch of one-bit-wide logic is identical memory cell pitch to array high density PEs in integrate structure. This format converter design has control path implementation efficiently, and can be utilize the high technology without complicated controller hardware. Sequence of array instruction are generated by host computer before process start, and instructions are saved on unit controller. Host computer is executed the pixel-parallel operation starting at saved instructions after processing start. As a result, we obtained three result that 1)simple smoothing suppresses higher spatial frequencies, reducing noise but also blurring edges, 2) a smoothing and segmentation process reduces noise while preserving sharp edges, and 3) median filtering, like smoothing and segmentation, may be applied to reduce image noise. Median filtering eliminates spikes while maintaining sharp edges and preserving monotonic variations in pixel values.

A Study on the Cognitive/Affective Personality and Experiential Factors Influencing on Smart Phone Users' Emotional Exhaustion and Education Performance (스마트폰 이용자의 정서적 소진과 학습 성과에 영향을 주는 인지·감성 성향과 사용 경험에 관한 연구)

  • Ming-Yuan Sun;Sundong Kwon;Yong-Young Kim
    • Information Systems Review
    • /
    • v.18 no.4
    • /
    • pp.69-88
    • /
    • 2016
  • Nowadays, organizations have adopted Smart Work to efficiently manage tasks, such as electronic document approval, customer management, and site inspection, without spatial-temporal constraints. Smartphones, which are commonly used in Smart Work, enable individuals to perform their jobs anytime and anywhere, thus blurring the boundary between work and non-work. To solve the problem of blurred work/non-work boundaries, a construct of self-control and affective factors needs to be considered because business style is changed from command to autonomy in the Smart Work context. Moreover, employees can convey their emotions easily over smartphones. Recent marketing studies have analyzed consumers' behavior based on the combination of cognitive, affective, and behavioral components, and researchers of information systems are also interested in these factors. However, previous research has some limitations, such as not classifying factors into cognitive, affective, and behavioral as well as not covering all three factors. Therefore, we explore the roles of cognitive, affective, and behavioral components in emotional exhaustion and education performance, and conduct a survey on undergraduate and graduate students, who are the major users of smartphones. Findings show that when individuals improve their cognitive capability (self-control) and usage experience (smartphone communication and internet usage), they can decrease emotional exhaustion and increase education performance. In the role of affective capability, increasing education performance is partially accepted. These results imply that organizations should not focus on controlling the usage of smartphones but on promoting appropriate smartphone usage.

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.