• Title/Summary/Keyword: Spatial Resection

Search Result 9, Processing Time 0.018 seconds

Analysis of the Accuracy of Quaternion-Based Spatial Resection Based on the Layout of Control Points (기준점 배치에 따른 쿼터니언기반 공간후방교회법의 정확도 분석)

  • Kim, Eui Myoung;Choi, Han Seung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.4
    • /
    • pp.255-262
    • /
    • 2018
  • In order to determine the three-dimensional position in photogrammetry, a spatial resection is a pre-requisite step to determine exterior orientation parameters. The existing spatial resection method is a non-linear equation that requires initial values of exterior orientation parameters and has a problem that a gimbal lock phenomenon may occur. On the other hand, the spatial resection using quaternion is a closed form solution that does not require initial values of EOP (Exterior Orientation Parameters) and is a method that can eliminate the problem of gimbal lock. In this study, to analyze the stability of the quaternion-based spatial resection, the exterior orientation parameters were determined according to the different layout of control points and were compared with the determined values using existing non-linear equation. As a result, it can be seen that the quaternionbased spatial resection is affected by the layout of the control points. Therefore, if the initial value of exterior orientation parameters could not be obtained, it would be more effective to estimate the initial exterior orientation values using the quaternion-based spatial resection and apply it to the collinearity equation-based spatial resection method.

Comparisons of Single Photo Resection Algorithms for the Determination of Exterior Orientation Parameters (단사진의 외부표정요소 결정을 위한 후방교회법 알고리즘의 비교)

  • Kim, Eui Myoung;Seo, Hong Deok
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.4
    • /
    • pp.305-315
    • /
    • 2020
  • The purpose of this study is to compare algorithms of single photo resection, which determines the exterior orientation parameters used in fields such as photogrammetry, computer vision, robotics, etc. To this end, the algorithms were compared by generating experimental data by simulating terrain based on a camera used in aerial and close-range photogrammetry. Through experiments on aerial photographic camera that was taken almost vertically, it was possible to determine the exterior orientation parameters using three ground control points, but the Procrustes algorithm was sensitive to the configuration of the ground control points. Even in experiments with a close-range amateur camera where the attitude angles of the camera change significantly, the algorithm was sensitive to the configuration of the ground control points, and the other algorithms required at least six ground control points. Through experiments with two types of cameras, it was found that cosine lawbased spatial resection shows performance similar to that of a traditional photogrammetry algorithm because the number of iterations is short and no explicit initial values are required.

Development of a Vehicle Positioning Algorithm Using In-vehicle Sensors and Single Photo Resection and its Performance Evaluation (차량 내장 센서와 단영상 후방 교차법을 이용한 차량 위치 결정 알고리즘 개발 및 성능 평가)

  • Kim, Ho Jun;Lee, Im Pyeong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.25 no.2
    • /
    • pp.21-29
    • /
    • 2017
  • For the efficient and stable operation of autonomous vehicles or advanced driver assistance systems being actively studied nowadays, it is important to determine the positions of the vehicle accurately and economically. A satellite based navigation system is mainly used for positioning, but it has a limitation in signal blockage areas. To overcome this limitation, sensor fusion methods including additional sensors such as an inertial navigation system have been mainly proposed but the high sensor cost has been a problem. In this work, we develop a vehicle position estimation algorithm using in-vehicle sensors and a low-cost imaging sensor without any expensive additional sensor. We determine the vehicle positions using the velocity and yaw-rate of a car from the in-vehicle sensors and the position and attitude of the camera based on the single photo resection process. For the evaluation, we built a prototype system, acquired test data using the system, and estimated the trajectory. The proposed algorithm shows the accuracy of about 40% higher than an in-vehicle sensor only method.

Hepatocellular Carcinoma: Texture Analysis of Preoperative Computed Tomography Images Can Provide Markers of Tumor Grade and Disease-Free Survival

  • Jiseon Oh;Jeong Min Lee;Junghoan Park;Ijin Joo;Jeong Hee Yoon;Dong Ho Lee;Balaji Ganeshan;Joon Koo Han
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.569-579
    • /
    • 2019
  • Objective: To investigate the usefulness of computed tomography (CT) texture analysis (CTTA) in estimating histologic tumor grade and in predicting disease-free survival (DFS) after surgical resection in patients with hepatocellular carcinoma (HCC). Materials and Methods: Eighty-one patients with a single HCC who had undergone quadriphasic liver CT followed by surgical resection were enrolled. Texture analysis of tumors on preoperative CT images was performed using commercially available software. The mean, mean of positive pixels (MPP), entropy, kurtosis, skewness, and standard deviation (SD) of the pixel distribution histogram were derived with and without filtration. The texture features were then compared between groups classified according to histologic grade. Kaplan-Meier and Cox proportional hazards analyses were performed to determine the relationship between texture features and DFS. Results: SD and MPP quantified from fine to coarse textures on arterial-phase CT images showed significant positive associations with the histologic grade of HCC (p < 0.05). Kaplan-Meier analysis identified most CT texture features across the different filters from fine to coarse texture scales as significant univariate markers of DFS. Cox proportional hazards analysis identified skewness on arterial-phase images (fine texture scale, spatial scaling factor [SSF] 2.0, p < 0.001; medium texture scale, SSF 3.0, p < 0.001), tumor size (p = 0.001), microscopic vascular invasion (p = 0.034), rim arterial enhancement (p = 0.024), and peritumoral parenchymal enhancement (p = 0.010) as independent predictors of DFS. Conclusion: CTTA was demonstrated to provide texture features significantly correlated with higher tumor grade as well as predictive markers of DFS after surgical resection of HCCs in addition to other valuable imaging and clinico-pathologic parameters.

Surgical Strategy of Epilepsy Arising from Parietal and Occipital Lobes (두정엽 및 후두엽 간질에 대한 수술전략)

  • Sim, Byung-Su;Choi, Ha-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.2
    • /
    • pp.222-230
    • /
    • 2000
  • Purpose : Resection of the epileptogenic zone in the parietal and occipital lobes may be relevant although only few studies have been reported. Methods : Eight patients with parietal epilepsy and nine patients with occipital epilepsy were included for this study. Preoperatively, all had video-EEG monitoring with extracranial electrodes, MRI, 3D-surface rendering of MRI using Allegro(ISG Technologies Inc., Toronto, Canada), and PET scans. Sixteen patients underwent invasive recording with subdural grid. Eight had parietal resection including the sensory cortex in two. Seven had partial occipital resection. Two underwent total unilateral occipital lobectomy. The extent of the resection was made based mainly on the data of invasive EEG recordings, MRI, and 3D-surface rendering of MRI, not on the intraoperative electrocorticographic findings as usually done. During resection, electrocortical stimulation was performed on the motor cortex and speech area. Results : Out of eight patients with parietal epilepsy, three had sensory aura, two had gustatory aura, and two had visual aura. Six of nine patients with occipital epilepsy had visual auras. All had complex partial seizures with lateralizing signs in 15 patients. Four had quadrantopsia. One had mild right hemiparesis. Abnormality in MRI was noticed in six out of eight parietal epilepsy and in eight out of nine occipital epilepsy. 3D-surface rendering of MRI visualized volumetric abnormality with geometric spatial relationships adjacent to the normal brain, in all of parietal and occipital epilepsy. Surface EEG recording was not reliable in localizing the epileptogenic zone in any patient. The subdural grid electrodes can be implanted on the core of the structural abnormality in 3D-reconstructed brain. Ictal onset zone was localized accurately by subdural grid EEGs in 16 patients. Motor cortex in nine and sensory speech area in two were identified by electrocortical stimulation. Histopathologic findings revealed cortical dysplasia in 10 patients ; tuberous sclerosis was combined in two, hamartoma and ganglioglioma in one each, and subpial gliosis in six. Eleven patients were seizure free at follow-up of 6 months to 37 months(mean 19.7 months) after surgery. Seizures recurred in two and were unchanged in one. Six produced transient sensory loss and one developed hemiparesis and tactile agnosia. One revealed transient apraxia. Two patients with preoperative quadrantopsia developed homonymous hemianopsia. Conclusion : This study suggests that surgical treatment was relevant in parietal and occipital epilepsies with good surgical outcome, without significant neurologic sequelae. Neuroimaging studies including conventional MRI, 3Dsurface rendering of MRI were necessary in identifying the epileptogenic zone. In particular, 3D-surface rendering of MRI was very helpful in presuming the epileptogenic zone in patients with unidentifiable lesion in the conventional MRI, in planning surgical approach to lesions, and also in making a decision of the extent of the epileptogenic zone in patients with identifiable lesion in conventional MRI. Invasive EEG recording with the subdural grid electrodes helped to confirm a core of the epileptogenic zone which was revealed in 3D-surface rendered brain.

  • PDF

Single Photo Resection Using Cosine Law and Three-dimensional Coordinate Transformation (코사인 법칙과 3차원 좌표 변환을 이용한 단사진의 후방교회법)

  • Hong, Song Pyo;Choi, Han Seung;Kim, Eui Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.3
    • /
    • pp.189-198
    • /
    • 2019
  • In photogrammetry, single photo resection is a method of determining exterior orientation parameters corresponding to a position and an attitude of a camera at the time of taking a photograph using known interior orientation parameters, ground coordinates, and image coordinates. In this study, we proposed a single photo resection algorithm that determines the exterior orientation parameters of the camera using cosine law and linear equation-based three-dimensional coordinate transformation. The proposed algorithm first calculated the scale between the ground coordinates and the corresponding normalized coordinates using the cosine law. Then, the exterior orientation parameters were determined by applying linear equation-based three-dimensional coordinate transformation using normalized coordinates and ground coordinates considering the calculated scale. The proposed algorithm was not sensitive to the initial values by using the method of dividing the longest distance among the combinations of the ground coordinates and dividing each ground coordinates, although the partial derivative was required for the nonlinear equation. In addition, since the exterior orientation parameters can be determined by using three points, there was a stable advantage in the geometrical arrangement of the control points.

Development of Low-Cost Data Acquisition Method for Close-range Digital Photogrammetric System (근거리 수치사진측량시스템을 위한 저가격 자료획득방법의 개발)

  • Park, Hong-Gi
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.7 no.2 s.14
    • /
    • pp.143-153
    • /
    • 1999
  • GIS have become easier to use and very popular. In recent year digital photogrammetric systems ire becoming cost-effective tools to build and update GIS databases. In close-range photogrammetry for the acquisition of geospatial data, the bundle adjustment needs both initial approximate values and control points to solve the exterior orientation parameters. This paper gives a review of applied and potential algorithms for estimating Initial approximate values before the bundle adjustment, develope new algorithms for determine the exterior orientation parameters, and gives a cost-effective methods for close-range digital photogrammetric system Modifications of existing DLT algorithm were made in this study for providing an efficient, economic, and more accurate photogrammetric data reduction technique. These modifications include robust approaches for automatic detection and elimination of all lands of gross errors in the measurement data, and incorporation of GPS to reduce the number of control points necessary for a DLT solution. Also, this paper derives a new method for space resection from a monocular image. A major advantage of proposed method is that the solution can be uniquely and analytically determined without initial approximate values of exterior orientation parameters and without iterative computation.

  • PDF

Boundary-Aware Dual Attention Guided Liver Segment Segmentation Model

  • Jia, Xibin;Qian, Chen;Yang, Zhenghan;Xu, Hui;Han, Xianjun;Ren, Hao;Wu, Xinru;Ma, Boyang;Yang, Dawei;Min, Hong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.1
    • /
    • pp.16-37
    • /
    • 2022
  • Accurate liver segment segmentation based on radiological images is indispensable for the preoperative analysis of liver tumor resection surgery. However, most of the existing segmentation methods are not feasible to be used directly for this task due to the challenge of exact edge prediction with some tiny and slender vessels as its clinical segmentation criterion. To address this problem, we propose a novel deep learning based segmentation model, called Boundary-Aware Dual Attention Liver Segment Segmentation Model (BADA). This model can improve the segmentation accuracy of liver segments with enhancing the edges including the vessels serving as segment boundaries. In our model, the dual gated attention is proposed, which composes of a spatial attention module and a semantic attention module. The spatial attention module enhances the weights of key edge regions by concerning about the salient intensity changes, while the semantic attention amplifies the contribution of filters that can extract more discriminative feature information by weighting the significant convolution channels. Simultaneously, we build a dataset of liver segments including 59 clinic cases with dynamically contrast enhanced MRI(Magnetic Resonance Imaging) of portal vein stage, which annotated by several professional radiologists. Comparing with several state-of-the-art methods and baseline segmentation methods, we achieve the best results on this clinic liver segment segmentation dataset, where Mean Dice, Mean Sensitivity and Mean Positive Predicted Value reach 89.01%, 87.71% and 90.67%, respectively.

Development of a multi-modal imaging system for single-gamma and fluorescence fusion images

  • Young Been Han;Seong Jong Hong;Ho-Young Lee;Seong Hyun Song
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3844-3853
    • /
    • 2023
  • Although radiation and chemotherapy methods for cancer therapy have advanced significantly, surgical resection is still recommended for most cancers. Therefore, intraoperative imaging studies have emerged as a surgical tool for identifying tumor margins. Intraoperative imaging has been examined using conventional imaging devices, such as optical near-infrared probes, gamma probes, and ultrasound devices. However, each modality has its limitations, such as depth penetration and spatial resolution. To overcome these limitations, hybrid imaging modalities and tracer studies are being developed. In a previous study, a multi-modal laparoscope with silicon photo-multiplier (SiPM)-based gamma detection acquired a 1 s interval gamma image. However, improvements in the near-infrared fluorophore (NIRF) signal intensity and gamma image central defects are needed to further evaluate the usefulness of multi-modal systems. In this study, an attempt was made to change the NIRF image acquisition method and the SiPM-based gamma detector to improve the source detection ability and reduce the image acquisition time. The performance of the multi-modal system using a complementary metal oxide semiconductor and modified SiPM gamma detector was evaluated in a phantom test. In future studies, a multi-modal system will be further optimized for pilot preclinical studies.