• 제목/요약/키워드: Source Calibration

검색결과 385건 처리시간 0.028초

APPLICATION OF MERGED MICROWAVE GEOPHYSICAL OCEAN PRODUCTS TO CLIMATE RESEARCH AND NEAR-REAL-TIME ANALYSIS

  • Wentz, Frank J.;Kim, Seung-Bum;Smith, Deborah K.;Gentemann, Chelle
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.150-152
    • /
    • 2006
  • The DISCOVER Project (${\underline{D}}istributed$ ${\underline{I}}nformation$ ${\underline{S}}ervices$ for ${\underline{C}}limate$ and ${\underline{O}}cean$ products and ${\underline{V}}isualizations$ for ${\underline{E}}arth$ ${\underline{R}}esearch$) is a NASA funded Earth Science REASoN project that strives to provide highly accurate, carefully calibrated, long-term climate data records and near-real-time ocean products suitable for the most demanding Earth research applications via easy-to-use display and data access tools. A key element of DISCOVER is the merging of data from the multiple sensors on multiple platforms into geophysical data sets consistent in both time and space. The project is a follow-on to the SSM/I Pathfinder and Passive Microwave ESIP projects which pioneered the simultaneous retrieval of sea surface temperature, surface wind speed, columnar water vapor, cloud liquid water content, and rain rate from SSM/I and TMI observations. The ocean products available through DISCOVER are derived from multi-sensor observations combined into daily products and a consistent multi-decadal climate time series. The DISCOVER team has a strong track record in identifying and removing unexpected sources of systematic error in radiometric measurements, including misspecification of SSM/I pointing geometry, the slightly emissive TMI antenna, and problems with the hot calibration source on AMSR-E. This in-depth experience with inter-calibration is absolutely essential for achieving our objective of merging multi-sensor observations into consistent data sets. Extreme care in satellite inter-calibration and commonality of geophysical algorithms is applied to all sensors. This presentation will introduce the DISCOVER products currently available from the web site, http://www.discover-earth.org and provide examples of the scientific application of both the diurnally corrected optimally interpolated global sea surface temperature product and the 4x-daily global microwave water vapor product.

  • PDF

멀티스펙트럴 재조명을 이용한 균일 조명 색상 보정 (Color Correction for Uniformity Illumination using Multispectral Relighting)

  • 심규동;박종일
    • 방송공학회논문지
    • /
    • 제22권2호
    • /
    • pp.207-213
    • /
    • 2017
  • 다수의 조명을 이용한 멀티스펙트럴 이미징을 정확히 수행하기 위해서는 영상 내 조명의 세기가 균일해야 한다. 멀티스펙트럴 이미징이 아니더라도 정확한 색 정보가 필요한 영상 획득에서는 조명이 정확해야 하고, 정확한 조명 특성을 위해 평면 광원을 사용하거나 조명 캘리브레이션을 수행한다. 본 논문에서는 조명의 세기가 균일하지 않은 영상을 조명의 세기가 균일하도록 색상을 보정하는 방법을 제안한다. 우선 비균일 조명에서 얻은 두 영상으로 멀티스펙트럴 이미징을 수행하여 반사 스펙트럼을 획득하고 획득한 반사 스펙트럼을 형광등이나 태양광과 같은 평면광에서 획득한 영상의 조명 특성으로 재조명한다. 재조명으로 얻은 영상과 평면광 영상의 조도 분포의 차이를 이용해서 비균일 조명 영상을 균일한 영상에서 획득한 영상처럼 색상 보정을 수행한다. 실험 결과로 조명의 비균일성이 균일하게 보정되었는지 확인하고, 이 결과를 통해 영상의 색 정보를 취득하는 데 조명의 제약사항을 줄일 수 있을 것으로 기대된다.

AE 측정을 위한 탐촉자의 보정에 대한 고찰 (A Study on the Transducer Calibration for Acoustic Emission Measurement)

  • 김교원
    • 지질공학
    • /
    • 제6권2호
    • /
    • pp.53-58
    • /
    • 1996
  • 암석 시료의 파괴시에 발생하는 AE신호를 측정하여 파괴와 관련된 미세균열의 발생원에 대한 연구를 위하여서는 탐촉자에서 기록장치까지 전과정에 대한 검증이 필요하다. 특히 탐촉자는 기계적인 진동을 전기신호로 전환하는 기능을 가진 예민한 장치로서 다양한 인자에 의하여 예민도가 달라질 수 있기 때문에 보정시험을 실리하여야 한다. 압전 압력형 PAC 탐촉자를 NBS나 DG의 변위형 탐촉자에 의하여 보정하는 시험을 실시하였다. NBS 및 PAC탐촉자는 파의 입사방위각에는 무관하나 입사각에는 예민하게 반응한다. 즉, 입사각이 $90^{\circ}$ 일 때에는 입사각 $15^{\circ}$ 이하 일 때보다 약 10배의 큰 출력을 나타내었다. 또한, 시험에 사용된 PAC 탐촉자가의 경우 강도에 대한 개별 예민도의 차이가 최대 약 40%이었다. 압력형 PAC 탐촉자는 변위형 표준탐촉자로 절대치 보정시험을 실시한 결과 보정계수는 평균 77mv/pm이었다.

  • PDF

인공지능을 이용한 이종액체 정상 상태 혼합의 혼합과정 해석 (Analyses of Steady State Mixing Process of Two-Liquids Using Artificial Intelligence)

  • 공대경;염주호;조경래;도덕희
    • 한국수소및신에너지학회논문집
    • /
    • 제29권5호
    • /
    • pp.523-529
    • /
    • 2018
  • Two liquids which are generally used as fuels of rockets are mixed and their mixing process is quantitatively investigated by the use of particle image velocimetry (PIV). As working fluids for the liquid mixing, Dimethylfuran (DMF) and JetA1 oils have been used. Since the specific gravity of DMF is larger than that of JetA1 oil, the DMF oil has been set at the lower part of the JetA1 oil. For better visualization of the mixing process, Rhodamin B powder has been blended into the DMF oil. An agitator having 3 blades has been used for mixing the two liquids. For quantitative visualization, a LCD monitor has been used as a light source. A color camera, camcoder, has been used for recording the mixing process. The images captured by the camcoder have been digitized into three color components, R, G, and B. The color intensities of R, G, and B have been used as the inputs of the neural network of which hidden layer has 20 neurons. Color-to-concentration calibration has been performed before commencing the main experiments. Once this calibration is completed, the temporal changes of the concentration of the DMF has been quantitatively analyzed by using the constructed measurement system.

Measurement Uncertainty of Nicotine in Environmental Tobacco Smoke (ETS)

  • Lee, Jeong-Il;Lee, Cheol Min;Shim, In-Keun;Kim, Seong-Mi;Lee, Woo-Seok;Kim, Yoon-Shin
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권8호
    • /
    • pp.2394-2398
    • /
    • 2013
  • Nicotine is the main component of environmental tobacco smoke, and its presence in indoor air is widely used as a secondhand-smoke indicator. Environmental tobacco smoke is a major source of indoor air pollution, but sufficient investigation of the uncertainty of its measurement, which mirrors the reliability of nicotine measurement, has not been performed. We calculated the uncertainty of measurement of indoor air nicotine concentration at low, medium, and high concentrations of 11.3798, 10.1977, $98.3768{\mu}g/m^3$, respectively, and we employed the Guide to the Expression of Uncertainty in Measurements (GUM), proposed by the International Organization for Standardization (ISO). The factors considered in determining the uncertainty were uncertainty of the calibration curve (calibration curve and repeated measurements), desorption efficiency, extraction volume, and sampling airflow (accuracy and acceptable limits of flowmeter). The measurement uncertainty was highest at low concentrations; the expanded measurement uncertainty is $0.9435{\mu}g/m^3$ and is represented as a relative uncertainty of 63.38%. At medium and high (concentrations, the relative uncertainty was 13.1% and 9.1%, respectively. The uncertainty of the calibration curve was largest for low indoor nicotine concentrations. To increase reliability of measurement in assessing the effect of secondhand smoke, measures such as increasing the sample injection rate ($1{\mu}L$ or more), increasing sampling volume to increase collected nicotine, and using gas chromatography-mass spectrometry (GC/MS) or GC/MS/MS, which has a lower quantitation threshold, rather than gas chromatography with nitrogen phosphorous detector, should be considered.

有機하로겐 化合物의 中性子線 照射에 依한 定性放射化 크로마토그래피에 關한 硏究 (Study on a Ridio Paper Partition Chromatography of Organic Halogen Compounds by a Neutron Irradiation. A Qualitative Approach)

  • 김유선;최송자
    • 대한화학회지
    • /
    • 제8권2호
    • /
    • pp.47-56
    • /
    • 1964
  • 展開한 페이퍼크로마토그램을 韓國 Triga-Mark-Ⅱ 硏究用 原子爐의 뉴마딕튜부施設(中性子線束; 1.5{\times}$10^{12}n/cm^2$, sec)을 利用하여 照射하여 본 結果 크로마토그램上에 展開된 스폿트(spot)를 定性的으로 確認할 수 있었다. 有機하로겐 化合物(크로로酸, 크로로에스테르, 沃化物, 及 弗化物)에 있어서 一般發色法으로서는 明確한 着色스폿트(spot)를 나타내지 못한 것에 있어서도, 이 方法으로서 展開된 스폿트를 明確히 區別할 수 있었다. 濾紙成分의 放射化에 依한 誤差를 減少시키기 爲하여 濾紙두께 補正 及 放射化度 補正을 硏究한 結果, 濾紙두께 補正 及 放射能崩壞 補正法을 究明하였으며, 이 方法으로 스폿트를 放射化하여 定性分析하는데 좋은 結果를 얻을 수 있었다. 有機하로겐化合物의 分析 及 確認에 있어서의 이 方法의 效用性에 關하여 論議하였다. 濾紙相으로는 正常相 及 逆相을 함께 使用하였다.

  • PDF

용접 시험편의 디지털 방사선 검사에서 밝기 교정과 중첩 영상에 따른 SNR 및 SRb 비교 연구 (Comparison Research of SNR and SRb with Bright Calibration and Multi Frame Images in Digital Radiography of Welded Test Components)

  • 남문호;양진욱;조갑호
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.731-739
    • /
    • 2021
  • 이 연구는 산업현장에서 구조물의 용접부 검사를 디지털 방사선을 이용한 비파괴검사를 효과적으로 수행할 수 있도록 디지털 방사선의 밝기 교정과 중첩 영상에 따른 신호 대 잡음 비와 기본 공간 분해능을 비교분석 하였다. 평판형 용접 시험편을 대상으로 75Se 방사선원을 사용하였고 촬영 전 밝기 교정과 영상 중첩을 세분화하여 총 130장의 영상을 획득하였다. 연구 결과, 밝기 교정의 수와 영상 중첩의 수가 증가할수록 신호 대 잡음 비가 향상됨을 확인하였다. 기본 공간 분해능은 촬영된 영상 모두 기준치를 만족하였다. 산란 방사선을 대비한 납 차폐를 설치 후 촬영한 영상을 비교하여 신호 대 잡음 비가 비슷함을 확인하였다. 영상 중첩이 증가할수록 신호 대 잡음 비가 증가하지만, 방사선의 노출시간이 증가하면서 작업자의 피폭 및 작업 효율에 영향을 미치기 때문에 적절한 촬영기법을 강구 한다면 좋은 상질의 디지털 방사선 영상을 획득 할 수 있을 것으로 사료된다.

ROADMOD를 이용한 도로청소 및 모래여과시설에 의한 고속도로에서의 강우시 TSS 저감효과 분석 (Removal Efficiency of TSS Loadings from Expressway by Road Sweeping and Sand Filter Facility Using ROADMOD)

  • 강희만;전지홍
    • 한국물환경학회지
    • /
    • 제39권1호
    • /
    • pp.38-45
    • /
    • 2023
  • In this study, the removal efficiency of road sweeping and sand filter facility for removing total suspended solid (TSS) as nonpoint source pollution from expressway was evaluated for the last 10 years (2012~2021) using ROADMOD. ROADMOD is a screening level model and was calibrated for runoff rate and TSS loading both at the inlet, which is the loading from the drainage area, and the outlet, from the sand filter facility. The drainage area is 715 m2 and the dimensions of sand filter facility are 1.5 m (wide) × 3.8 m (length) × 1.5 m (depth). The monitoring period for model calibration was the rainfall event during Aug. 31~Sep. 1, 2021 and the amount of rainfall was 74.5 mm. As a result of calibration, the determination coefficients (R2) of the flow rate were 0.66 and 0.86, for the inlet and outlet, respectively, and those of TSS loading were 0.50 and 0.84, for the inlet and outlet, respectively. Considering that ROADMOD is a screening level model, the calibration results were reasonable to evaluate the best management practices (BMPs) on the expressway. Using ROADMOD simulation results for 2012~2021, the average yearly runoff rate from the expressway was 82% and removal efficiency was 9% for road sweeping, 35% for sand filter facility, and 39% for both road sweeping and sand filter facility.

Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석 (Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter)

  • 장지용;정문택;송종남;하재준;한재복
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.31-37
    • /
    • 2018
  • 단창형의 Geiger-Muller 계수관을 이용한 표면오염검사에서 베타선을 측정하기 위해 외부로 노출된 디텍터를 보호하는 방법으로 랩을 사용하고 있는데 이 방법이 측정계수율과 교정인자에 미치는 영향을 분석하고 방사선작업종사자에게 과도한 랩의 사용은 베타선의 측정값에 영향을 줄 수 있음을 인지시켜주고자 하였다. 실험방법은 3 KBq, 1.5 KBq, 0.3 KBq의 에너지가 다른 베타선을 이용하여 랩 두께에 따른 베타선 측정계수율과 교정인자의 변화를 비교 분석하였다. 실험 대상으로는 2012년 3월 한국인정기구 (KOLAS) 인증을 받은 교정센터에서 보유한 단창형의 Geiger-Muller 계수관을 대상으로 하였으며, Cl-36(Chlorine)과 Sr-90(Strontium)을 베타선 방사선원으로 사용하였다. 측정계수율은 랩 두께가 증가할수록 감소함을 확인 할 수 있었고 교정인자는 랩 두께가 증가할수록 증가하는 것을 알 수 있었다. 측정계수율의 감소와 교정인자의 변화는 기기지시값의 정확도를 감소시킬 수 있지만 디텍터의 오염 및 손상 또한 베타선 측정에서 중요한 영향을 주기 때문에 어느 정도 두께의 랩을 사용함이 가장 효과적인지 알아볼 필요성이 있다. 측정계수율과 교정인자의 낮은 변화율을 보여주는 두께의 랩을 사용한다면 디텍터를 보호하면서 베타선의 측정값에도 영향을 최소한으로 줄 수 있을 것으로 사료된다.

영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구 (Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy)

  • 김진성;조민국;조영빈;윤한빈;김호경;윤명근;신동호;이세병;이레나;박성용;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.209-218
    • /
    • 2008
  • IMRT, 양성자 치료와 같이 방사선 치료 기술이 발전할수록 치료 시 환자의 위치를 확인하고 그 정확성을 평가하는 기술의 중요성이 강조되고 있다. 현재 국립암센터 양성자치료센터에 설치되어 있는 양성자 치료기의 단순 X-선 영상시스템을 이용하여 콘빔 CT (cone-beam CT) 3차원 영상을 획득, 영상유도 방사선 치료의 가능성을 확인하고자 하였다. 양성자 치료기에 설치되어있는 X-선 영상시스템(SDD: 2,108 mm, SOD: 1,511 mm, Varian a277 x-ray tube & Varian Paxscan 4030: a-Si+DRZ screen)을 이용하여 양성자 갠트리를 $2^{\circ}$씩 회전시켜가면서 기하학적인 오차 측정을 위한 팬톰과 인체 팬톰 (Humanoid phantom, Rando, CA, USA)의 투사영상을 획득하였다. 현재 시스템적으로 연속적인 회전과 영상획득이 지원되지 않아서 영상획득 후 갠트리를 회전하는 방법으로 투사영상을 획득하였다. 기하학적 오차측정을 위한 팬텀과 두경부 팬텀에 대해서 $360^{\circ}$를 회전하며 180장의 투사영상($2,304{\times}3,200$, 14 bit with 127${\mu}m$ pixel pitch)을 관전압 85 kVp, 관전류 80 mA, 조사시간 0.5 s의 조건으로 촬영하였다. 콘빔 CT 영상재구성을 위해 Ram-Lak filter를 적용한 Feldkamp cone-beam 알고리즘을 사용하였으며, 획득한 180장의 투사영상을 사용하여 $0.4{\times}0.4{\times}0.4mm^3$의 voxel size를 가진 $512{\times}512{\times}512$ CT영상을 재구성하였다. 기하학적인 오차 측정방법을 통해 X-선 선원, 검출기와 갠트리의 기하학적 정보를 측정하였다. 측정된 결과에 의하면 검출기가 $0.25^{\circ}$ 회전된 오차를 보이는 것을 발견하였다. 기하학적 교정으로 재구성된 콘빔 CT 영상을 multi-planar view (axial, sagittal and coronal view) 및 3차원 영상으로 재구성하여 비교 평가 하였다. 현재 양성자치료기에 설치되어있는 단순 X-선 영상 시스템에서 기하학적 오차 측정을 위한 볼 팬텀을 이용하여 시스템의 오차를 측정하였다. 측정한 오차를 바탕으로 기하학적 교정을 통해서 두경부 및 복부 팬텀에 대한 3차원 영상인 콘빔 CT 영상들을 재구성하였다. 추후 연속적인 회전을 통한 영상획득이 가능하게 된다면, 보다 정확하고 신속한 영상재구성이 가능 하며 콘빔 CT가 영상유도 양성자 치료에 매우 유용할 것으로 사려된다.

  • PDF