• 제목/요약/키워드: Sound attenuation

검색결과 210건 처리시간 0.022초

음향인텐시티법을 이용한 공조 덕트소음기의 감음성능평가방법에 관한 연구 (The Estimation of Sound Attenuation Caused by Duct Silencer Using Sound Intensity Method)

  • 김석홍;손장열;오재응;김여식
    • 한국음향학회지
    • /
    • 제6권2호
    • /
    • pp.54-61
    • /
    • 1987
  • 실험실이 아닌 일반음장에서 음향인텐시티법을 이용하여 공조덕트 소기기의 감음성능 평가방법을 검토하였다. 음향인델시티법에 의한 감음량 측정치는 음압법에 의한 측정치보다 이논치와 비교적 잘 일치하였으며, 음향인텐시티법은 음압법에 비하여 음장조건에 따른 영향을 비교적 적게 받는 것으로 나타났다.

  • PDF

공동주택에서의 화재 경보음 전달특성에 관한 연구 (An Study on the Sound Attenuation of Audible Fire Alarm Device in Apartment Buildings)

  • 이민주;김명준;윤명오
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.658-661
    • /
    • 2005
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10dBA. To give the minimum sound level 60dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

  • PDF

Acoustic Properties of Solid Materials: Sound Speed, Transmission Coefficient, and Attenuation

  • Roh Heui-Seol;Lee Kang Il;Jung Kyung-Il;Yoon Suk Wang
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2002년도 하계학술발표대회 논문집 제21권 1호
    • /
    • pp.525-528
    • /
    • 2002
  • The speed of sound, transmission coefficient, and attenuation are measured around the center frequency 1 and 2 MHz in solid materials such as bone, sediment, rubber, and Lucite materials. Common and different characteristics of such materials in the sound speed, transmission coefficient, and attenuation are discussed. Ambiguities in estimating such acoustic characteristics we also addressed. Ultrasonic properties of the first and second kind waves are clarified for different materials. Discussions are concentrated on classes of sound speed, broadband ultrasonic attenuation (BUA), and correlations of sound speed and BUA with apparent density. New correlations of inverse sound speed square and BUA with apparent density are suggested.

  • PDF

공동주택 화재 경보음 전달특성과 개선방안 고찰 (An Study on the Sound Attenuation and the Improvement in Hearing Condition of Fire Alarm Device in Apartment Buildings)

  • 이민주;윤명오;김명준
    • 한국소음진동공학회논문집
    • /
    • 제16권6호
    • /
    • pp.593-601
    • /
    • 2006
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10 dBA. To give the minimum sound level 60 dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

고속도로 교통소음 예측-전달감쇠 산정 (Prediction of Highway Traffic Noise-calculation of Sound Attenuation during Propagation)

  • 조대승;김진형;최태묵;오정한;김성훈
    • 한국소음진동공학회논문집
    • /
    • 제12권3호
    • /
    • pp.236-242
    • /
    • 2002
  • This paper presents some advanced and supplemental methods to enhance the accuracy In case of calculating geometric divergence attenuation, attenuation by multiple screening structures, ground attenuation at unflat surfaces of sound during propagation outdoors by the methods specified in ISO 9613-2. Moreover, a calculation method for considering short-term wind effect, specified in ASJ Model-1998, is also introduced. To verity the accuracy of adopted methods, we have carried out highway traffic noise prediction and measurement at tile twelve locations appearing representative road shapes and structures, such as flat, retained cut, elevated, barrier-constructed roads. From the results, we have confirmed the predicted results show good correspondence with the measured at direct, diffracted and reflected sound fields within 30 m from the center of near side lane.

Theoretical Study of Coherent Acoustic Inverse Method for Bubble Sizing in Bubbly Water

  • Choi, Bok-Kyoung;Yoon, Suk-Wang
    • The Journal of the Acoustical Society of Korea
    • /
    • 제15권4E호
    • /
    • pp.3-8
    • /
    • 1996
  • The bubble size distribution is critical information to understand sound propagation and ambient noise in the ocean. To estimate the bubble size distribution in a bubbly water, the sound attenuation has been only in the conventional acoustic bubble sizing method without considering the sound speed variation. However, the effect of the sound speed variation in bubbly water cannot be neglected because of its compressibility variation. The sound attenuation is also affected by the sound speed variation. In this paper, a coherent acoustic bubble sizing inverse technique is introduced as a new bubble sizing technique with considering sound speed variation as well as the sound attenuation. This coherent sizing method is theoretically verified with the bubble distribution functions of single-size, Gaussian, and power-law functions. Its numerical test results with the coherent acoustic bubble sizing method show good agreement with the given bubble distributions.

  • PDF

격자구조로 배열된 실린더에 의한 음파감쇠 (Sound Attenuation by Cylinders Arranged in a Lattice)

  • 김현실;김상렬;김재승;김봉기;이성현
    • 한국소음진동공학회논문집
    • /
    • 제21권11호
    • /
    • pp.1013-1019
    • /
    • 2011
  • Sound attenuation of periodically arranged cylindrical rods is studied numerically and experimentally. Cross section of the cylinder is circular and arrays are in a square lattice. Cylinders are made of steel, and consist of five groups with different diameters from 27.2 mm to 48 mm. Each group has 5 rows, while number of cylinders in a row varies from 17 to 31. The area filling fraction is about 60~61 %, which leads to the stop bandgap(2.9 kHz ~ 8.4 kHz). Sound attenuation is computed using two-dimensional BEM, and measurement is done by using a speaker and microphones in a semi-anechoic room. Comparison of the results by BEM and experiment shows that attenuation spectra are qualitatively in agreement, although experiment gives higher attenuations than BEM. After results by BEM are scaled up in accordance with cylinder diameter, it is observed that attenuation curves are in good agreement, which confirms that analysis by BEM is done correctly. It is also found that the measured bandgaps are shifted toward lower frequency by 0.5 kHz ~ 1.2 kHz, when compared to the predictions obtained from infinitely repeated two-dimensional cylinder arrays.

두 개의 각주형 건물에 의한 도로교통소음의 감쇠에 관한 연구 (A Study on the Attenuation of Road Traffic Noise with two Pillar Buildings)

  • 김화일
    • 한국환경과학회지
    • /
    • 제12권1호
    • /
    • pp.69-76
    • /
    • 2003
  • When houses or buildings are adjacent to roads, with no effective prevention of road traffic noise, neighbors are exposed to it. It is important to understand the properties of sound propagation before taking a countermeasure against road traffic noise. It is easy to estimate the properties of sound propagation without obstacles, but very difficult and complex to estimate them with ones. The purpose of this study is to present a useful tool that can estimate the properties of sound propagation. In the beginning of this study, we investigated the attenuation of road traffic noise with two pillar buildings, and presented practical approximate calculation method, and verified that through scale model. The outcomes from this study are as follows : (1) Over second reflection sound waves can be ignored. (2) Diffraction sound waves that happen when reflection sound and first diffraction wave are projected at the wedge of other building can be ignored.

공동주택 화재경보 발생음 특성에 관한 실험연구 (Experimental study on the sound attenuation of the fire alarm sounder system in apartment buildings)

  • 이민주;강희혁;권봉석;김명준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1162-1168
    • /
    • 2007
  • In many fire emergencies, the audible fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the fire alarm worked. This is the study to show the sound attenuation of the fire alarm sounder system in apartment buildings. We measured and analyzed the sound attenuation level in 17 units, and the results were compared with the minimum sound level at sleeping area by NFPA(National Fire Protection Association) 72. When only the fire alarm worked in stair hall, the sound levels in bedroom were in the range of $30.6{\sim}42.8dB(A)$ and the differences between sound level and ambient sound level in bedrooms were in the range of $7.1{\sim}13.8dB(A)$. And when the emergency broadcasting device in the livingroom and the fire alarm worked simultaneously, the sound levels in bedrooms were in the range of $54.2{\sim}63.0dBA$. Finally, it was showed that the fire alarm sounder system didn't give a sufficient sound level in bedroom to awake out of sleep.

  • PDF

韓半島 周邊海域 海底 表層蓄積物 音波 空曠係數와 생物起源 氣滯含量 (Sound Attenuation Coefficients and Biogenic Gas Content in the Offshore Surficial Sediments Around the Korean Peninsula)

  • 김한준;덕봉철
    • 한국해양학회지
    • /
    • 제25권1호
    • /
    • pp.26-35
    • /
    • 1990
  • 한반도 주변 4개 해혁(포항, 부산, 여수, 군산)의 해저 표층축적물에서 얻은 음향 자료로부터 음속과 음파감쇠를 구하여 물성과의 상관성을 검토하고, 기체함량을 추정 함으로써 음파의 기계적 원인을 분석하였다. 음속 및 음파감쇠의 범위는 각각 1470∼ 1616 m/sec 및 0.0565∼0.6604 dB/kHz-m로서 퇴적물의 유형에 밀접하게 관련된다. 음 파는 coarse silt에서 최대이며 표층퇴적물내 기체 함량의 추정값은 8 ppm 이하로서 퇴적물의 입자가 작을수록 증가한다. Find sand보다 입자가 큰 퇴적물에서는 마찰손실 이 절대적인 음파감쇠의 요인으로 작용하며, 점성손실은 무시할 수 있을 뿐만 아니라 퇴적물의 물성에 따라 변하지 않는다. Coarse silt에서 음파감쇠가 최대인 것은 마찰 손실 뿐만 아니라 silt 입자 차이에 존재하는 더 작은 입자들 간의 결합력이 동시에 작용하기 때문이며 fine 및 medium silt를 경계로 입자가 작아짐에 따라 입자간 결합 력이 주된 감쇠 요인으로 작용한다.

  • PDF