• Title/Summary/Keyword: Sound Enhancement

Search Result 115, Processing Time 0.028 seconds

Mechanisms of Convective and Boiling Heat Transfer Enhancement via Ultrasonic Vibration (초음파 진동에 의한 대류 및 비등 열전달 촉진 원리에 관한 연구)

  • Kim, Yi-Gu;Kim, Ho-Young;Kang, Seoung-Min;Kang, Byung-ha;Lee, Jin-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.5
    • /
    • pp.612-619
    • /
    • 2003
  • This work experimentally studies the fundamental mechanisms by which the ultrasonic vibration enhances convection and pool boiling heat transfer. A thin platinum wire is used as both a heat source and a temperature sensor. A high speed video imaging system is employed to observe the behavior of cavitation and thermal bubbles. It is found that when the liquid temperature is below its boiling point, cavitation takes place due to ultrasonic vibration while cavitation disappears when the liquid reaches the boiling point. Moreover, when the gas dissolved in liquid is removed by pre-degassing, the cavitation arises only locally. Depending on the liquid temperature, heat transfer rates in convection, subcooled boiling and saturated boiling regimes are examined. In convection heat transfer regime, fully agitated cavitation is the most efficient heat transfer enhancement mechanism. Subcooled boiling is most enhanced when tile local cavitation is induced after degassing. In saturated boiling regime, acoustic pressure is shown to be a dominant heat transfer enhancement mechanism.

Spectral subtraction based on speech state and masking effect

  • 김우일;강선미;고한석
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.599-602
    • /
    • 1998
  • In this paper, a speech enhancement method based on phonemic properties and masking effect is propsoed. It is a modified type of spectral subtraction wherein the spectral sharpening process is exploited in unvoiced state considering the phonemic properties. The masking threshold is used to remove the residual noise. The proposed spectral subtraction shows similar performance as that of the classical spectral subtraction method in view of the SNR. But by the prposed scheme, the unvoiced sound region is shown to exhibit relatively less signal distortion in the enhanced speech.

  • PDF

Comparison of Sleep Pattern, Factors of Sleep Disturbance and Sleep Enhancement Behaviors between Sleep Disturbance and Non-Sleep Disturbance Aged Patients (수면장애 노인 환자와 일반 노인 환자의 수면양상, 수면장애요인 및 수면증진행위)

  • Han, Suk-Jung;Lee, Eun-Young;Kim, Kyung-Mi;Park, Sun-Nam
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.14 no.1
    • /
    • pp.62-71
    • /
    • 2007
  • Purpose: This study was done to compare sleep patterns, factors of sleep disturbance and sleep enhancement behaviors between sleep disturbance and non-sleep disturbance elderly patients. Method: The participants were 117 patients over 65 years old who were hospitalized at 5 general hospitals in Seoul. There were 83 patients in the good sleeper group and 34 in the poor sleeper group. The survey questionnaires included questions on general characteristics, sleep patterns, sleep disturbing factors, and sleep enhancement behaviors of the patients. Results: For sleep patterns and environmental factors of sleep disturbance, the poor sleepers was significantly higher than that of the good sleepers. Significant differences between good sleepers and poor sleepers were also found on the following variables: Environmental factors of sleep disturbance -'Sound of other patient's or care-giver's', 'Discomfort of bed, linen, pillow and patient's gown', 'Light in the room', 'Emergency situations', 'Temperature of patients rooms too hot or too cold'. The significant physical factor of sleep disturbance was 'Hard to breath even without moving' and for sleep enhancement behaviors: 'Use of ear plugs or eye covers' Conclusion: Consequently it is necessary to develop positive and differentiated programs for sleep enhancement for the inactive and poor sleeper among the elderly patients.

  • PDF

Effects of Indirect Forest Experience on Human Psychology (간접적 산림체험이 인체의 심리에 미치는 효과)

  • Jeon, Jin young;Shin, Chang Seob
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.4
    • /
    • pp.420-427
    • /
    • 2017
  • The purpose of this study was to investigate the indirect effects of forest using the forest healing factors such as landscape and hearing factors on mood improvement. The experiment was conducted for about 2 months from October 5, 2016 to November 30, 2016 targeting 30 healthy college students ($23.6{\pm}1.7$ years old). After making 3 factors(image factor, sound factor and image+sound factor) using scenery and sound of both forest and urban space, participants undergone the test in a room. And the effects of these 3 factors on the mood improvement were compared and analyzed using SPSS 18.0 program. Profile of Mood State test (POMS) and Semantic Differential method (SD) were used to measure mood improvement as a psychological test. As a result, indirect forest stimulation showed effects of suppressing tension, fatigue, anger, confusion, depression, and enhancement of vitality. No significant difference was observed in the comparison between forest stimuli. However, Compared with the urban stimuli, the stimulation of the forests has the effect of enhancing pleasant, natural feeling and calmness.

An Implementation of Sound Enhanced MPEG-1 Audio Decoder on Embedded OS Platform (음질향상 알고리즘을 내장한 MPEG-1 오디오 디코더의 Embedded OS 플랫폼에의 구현)

  • Hong, Sung-Min;Park, Kyu-Sik
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.8
    • /
    • pp.958-966
    • /
    • 2007
  • In this paper, we implement a sound-enhanced MPEG-1 audio decoder on embedded OS Platform. Low bit rate lossy audio codecs such as MP3, OGG, and AAC for mitigating the problems in storage space and network bandwidth suffer a major common problem such as a loss of high frequency fidelity of audio signal. This high frequency loss will reproduce only a band-limited low-frequency part of audio in the standard CD-quality audio. In order to overcome this problem, we embedded a sound enhancement algorithm into the MPEG-1 audio decoder and then the algorithms optimized according to the characteristic of the MPEG-1 audio layer I, II, III were implemented on an embedded OS platform. From the experimental results with spectrum analysis and listening test, we confirm the superiority of the proposed system compared to the standard MPEG-1 audio decoder.

  • PDF

DIGITAL IMAGE PROCESSING AND CLINICAL APPLICATION OF VIDEODENSITOMETER (실험적으로 제작한 Videodensitometer의 디지털 영상처리와 임상적 적용에 관한 연구)

  • Park Kwan-Soo;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.273-282
    • /
    • 1992
  • The purpose of this study was to propose the utility which was evaluated the digital image processing and clinical application of the videodensitomery. The experiments were performed with IBM-PC/16bit-AT compatible, video camera(CCdtr55, Sony Co., Japan), an color monitor(MultiSync 3D, NEC, Japan) providing the resolution of 512×480 and 64 levels of gray. Sylvia Image Capture Board for the ADC(analog to digital converter) was used, composed of digitized image from digital signal and the radiographic density was measured by 256 level of gray. The periapical radiograph(Ektaspeed EP-21, Kodak Co., U. S. A) which was radiographed dried human mandible by exposure condition of 70 kVp and 48 impulses, was used for primary X-ray detector. And them evaluated for digitzed image by low and high pass filtering, correlations between aluminum equivalent values and the thickness of aluminum step wedge, aluminum equivalent values of sound enamel, dentin, and alveolar bone, the range of diffuse density for gray level ranging from 0 to 255. The obtained results were as follows: 1. The edge between aluminum steps of digitized image were somewhat blurred by low pass filtering, but edge enhancement could be resulted by high pass filtering. Expecially, edge enhancement between distal root of lower left 2nd molar and alveolar lamina dura was observed. 2. The correlation between aluminum equivalent values and the thickness of aluminum step wedge was intimated, yielding the coefficient of correlation r=0.9997(p<0.00l), the regression line was described by Y=0.9699X+0.456, and coefficient of variation amounting to 1.5%. 3. The aluminum equivalent values of sound enamel, dentin, and alvolar bone were 15.41㎜, 12.48㎜, 10.35㎜, respectively. 4. The range of diffuse density for gray level ranging from 0 to 255 was wider enough than that of photodenstiometer to be within the range of 1-4.9.

  • PDF

Nitrogen allocation of Gracilaria tikvahiae grown in urbanized estuaries of Long Island Sound and New York City, USA: a preliminary evaluation of ocean farmed Gracilaria for alternative fish feeds

  • Johnson, Ronald B.;Kim, Jang K.;Armbruster, Lisa C.;Yarish, Charles
    • ALGAE
    • /
    • v.29 no.3
    • /
    • pp.227-235
    • /
    • 2014
  • The red seaweed, Gracilaria tikvahiae McLachlan, was cultivated in open water farms in urbanized estuaries of Long Island Sound (26-30 psu of salinity) and New York City (20-25 psu), USA in 2011. Plants were harvested monthly from summer (August, $24^{\circ}C$) to fall (November, $13^{\circ}C$) and analyzed for total nitrogen, protein, and amino acid content. On a dry matter (DM) basis, nitrogen and protein significantly increased over the harvest period until October and then plateaued. Nitrogen increased from $22{\pm}1g\;kg^{-1}$ DM in August to $39{\pm}3g\;kg^{-1}$ DM in October (p < 0.001). Protein increased from $107{\pm}13g\;kg^{-1}$ DM in August to $196{\pm}5g\;kg^{-1}$ DM in November (p < 0.001). With two exceptions, amino acid concentrations expressed on a crude protein (CP) basis were similar over the harvest period. Essential amino acids accounted for $48{\pm}1%$ of all amino acids present with lysine and methionine averaging $56{\pm}2g\;kg^{-1}$ CP and $18{\pm}1g\;kg^{-1}$ CP, respectively. Histidine was underrepresented among essential amino acids and averaged $13{\pm}1g\;kg^{-1}$ CP. Taurine ranged from 2.1 to $3.2g\;kg^{-1}$ DM. With its moderate levels of lysine, methionine and taurine, ocean farmed G. tikvahiae has the potential of overcoming many nutrient deficiencies currently associated with terrestrial plant ingredients in alternative feeds for fish and shrimp.

Objective Evaluation of Beamforming Techniques for Hearing Devices with Two-channel Microphone (2채널 마이크로폰을 이용한 청각 기기에서의 빔포밍에 대한 객관적 검증)

  • Cho, Kyeong-Won;Han, Jong-Hee;Hong, Sung-Hwa;Lee, Sang-Min;Kim, Dong-Wook;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.198-206
    • /
    • 2011
  • Hearing devices like cochlear implant, vibrant soundbridge, etc. try to offer better sound for people. In hearing devices, several beamformers including conventional directional microphone are applicable to noise reduction. Each beamformer has different directional response and it could change sound intelligibility or quality for listeners. Therefore, we investigated the performance of three beamformers, which are first and second order directional microphone, and broadband beamformer(BBF) with a computer simulation assuming hearing device microphone configuration. We also calculated objective measurements which have been used to evaluate speech enhancement algorithms. In the simulation, a single speech and a single babble noisewere propagated from the front and $135^{\circ}$ azimuth degrees respectively. Microphones were configured in an end-fire array and the spacing was varied in comparison. With 3 cm spacing, BBF had about 3 dB higher enhanced SNR than that of directional microphones. However, enhancement of segmental SNR and frequency weighted segmental SNR were similar between the first order directional microphone and broadband beamformer. In addition when steady state noise was used, broadband beamformer showed the increased performance and had the highest enhanced SNR, and segmental SNR.

A study on the application of residual vector quantization for vector quantized-variational autoencoder-based foley sound generation model (벡터 양자화 변분 오토인코더 기반의 폴리 음향 생성 모델을 위한 잔여 벡터 양자화 적용 연구)

  • Seokjin Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.2
    • /
    • pp.243-252
    • /
    • 2024
  • Among the Foley sound generation models that have recently begun to be studied, a sound generation technique using the Vector Quantized-Variational AutoEncoder (VQ-VAE) structure and generation model such as Pixelsnail are one of the important research subjects. On the other hand, in the field of deep learning-based acoustic signal compression, residual vector quantization technology is reported to be more suitable than the conventional VQ-VAE structure. Therefore, in this paper, we aim to study whether residual vector quantization technology can be effectively applied to the Foley sound generation. In order to tackle the problem, this paper applies the residual vector quantization technique to the conventional VQ-VAE-based Foley sound generation model, and in particular, derives a model that is compatible with the existing models such as Pixelsnail and does not increase computational resource consumption. In order to evaluate the model, an experiment was conducted using DCASE2023 Task7 data. The results show that the proposed model enhances about 0.3 of the Fréchet audio distance. Unfortunately, the performance enhancement was limited, which is believed to be due to the decrease in the resolution of time-frequency domains in order to do not increase consumption of the computational resources.

Improved Melody Recognition Performance of a Cochlear Implant Speech Processing Strategy Using Instantaneous Frequency Encoding Based on Teager Energy Operator

  • Choi, Sung-Jin;Ryu, Sang-Baek;Kim, Kyung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.6
    • /
    • pp.417-426
    • /
    • 2010
  • We present a speech processing strategy incorporating instantaneous frequency (IF) encoding for the enhancement of melody recognition performance of cochlear implants. For the IF extraction from incoming sound, we propose the use of a Teager energy operator (TEO), which is advantageous for its lower computational load. From time-frequency analysis, we verified that the TEO-based method provides proper IF encoding of input sound, which is crucial for melody recognition. Similar benefit could be obtained also from the use of a Hilbert transform (HT), but much higher computational cost was required. The melody recognition performance of the proposed speech processing strategy was compared with those of a conventional strategy using envelope extraction, and the HT-based IF encoding. Hearing tests on normal subjects were performed using acoustic simulation and a musical contour identification task. Insignificant difference in melody recognition performance was observed between the TEO-based and HT-based IF encodings, and both were superior to the conventional strategy. However, the TEO-based strategy was advantageous considering that it was approximately 35% faster than the HT-based strategy.