Characterization of RF Sputter-deposited Sodium Phosphorous Oxynitride Thin Films as a Solid-state Sodium-ion Conductor

  • Chun, Sang-Eun
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.4
    • /
    • pp.237-243
    • /
    • 2017
  • We demonstrated the thin film deposition of sodium phosphorous oxynitride (NaPON) via RF magnetron sputtering of $Na_3PO_4$, as a solid-state Na-ion conductor similar to lithium phosphorous oxynitride (LiPON), which is a commonly used solid electrolyte. The deposited NaPON thin film was characterized by scanning electron microscopy, X-ray diffractometry, and electrochemical impedance spectroscopy, to investigate the feasibility of the solid-state electrolyte in several different cell configurations. The key properties of a solidstate electrolyte, i.e., ionic conductivity and activation energy, were estimated from the complex non-linear least square fitting of the measured impedance spectra at various temperatures in the range of $27-90^{\circ}C$. The ionic conductivity of the NaPON film was measured to be $8.73{\times}10^{-6}S\;cm^{-1}$ at $27^{\circ}C$, which was comparable to that of the LiPON film. The activation energy was estimated to be 0.164 eV, which was lower than that of the LiPON film (0.672 eV). The obtained values encourage the use of a NaPON thin film in the future as a reasonable solid-state electrolyte.

High-harmonic Generation from Solid Surface Using an Oscillating Mirror Model and Plasma Mirror System for High Contrast Laser Pulse

  • Kim, I-Jong;Choi, Il-Woo;Janulewicz, Karol Adam;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.15-21
    • /
    • 2009
  • High-order harmonic generation from a solid surface affected by the contrast of a laser pulse was studied using an oscillating mirror model. High-order harmonics generated from solid surfaces have unusual properties such as spectral redshift, and an intensity difference between even- and odd-order harmonics which is not reported for high-order harmonics generated by a gas medium. We confirmed that high-order harmonics from solid surfaces have selectivity of polarization as well as cut-off extension and the enhancement of conversion efficiency proportional to laser intensity. And the principle of operation and the characteristics of a plasma mirror system developed for achieving high contrast laser pulses to pursue the experimental realization of high-harmonic generation from solid surfaces are reported. Energy fluence on the plasma mirrors is tunable between $10\;J/cm^2$ and $1000\;J/cm^2$ and around 1000 shots are available before the plasma mirrors require replacement.

Manufacture of Activated Carbon based on Solid Residue after Lignin Pyrolysis (리그닌 열분해 잔류고형물을 원료로 한 활성탄의 제조)

  • Lee, Jong-Jib;Yoon, Sung-Wook;Lee, Byung-Hak
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.133-139
    • /
    • 2000
  • In this study, activated carbon was prepared from solid residue after lignin pyrolysis by using zinc chloride as an activation agent. The steam activation method was adopted to manufacture activated carbon from solid residue after lignin pyrolysis. The effect of process operation variables such as activation temperature, activation time and mass of activation agent added to char on the pore structure and specific surface area of the activated carbon was investigated. Activated carbon with high surface area and well-developed pore structure could be prepared, when solid residue after lignin pyrolysis was mixed with zinc chloride of 300 wt% and then the mixture was activated for 1 hour at $1000^{\circ}C$ in a stream of nitrogen.

  • PDF

Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13) (상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정)

  • Kim, Ji-Hye;Baek, Tae-Hyeun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.2
    • /
    • pp.203-214
    • /
    • 2011
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.

A HEAVISIDE-FUNCTION APPROACH FOR THE INTERACTION OF TWO-PHASE FLUID AND NON-DEFORMABLE SOLID

  • Kang, Myung-Joo;Min, Cho-Hong
    • The Pure and Applied Mathematics
    • /
    • v.19 no.2
    • /
    • pp.147-169
    • /
    • 2012
  • We introduce a Heaviside-function formulation of the interaction between incompressible two-phase fluid and a non-deformable solid. Fluid and solid interact in two ways : fluid satises the Dirichlet boundary condition imposed by the velocity field of solid, and solid is accelerated by the surface traction exerted by fluid. The two-way couplings are formulated by the Heaviside function to the interface between solid and fluid. The cumbersome treatment of interface is taken care of by the Heaviside function, and the interaction is discretized in a simple manner. The discretization results in a stable and accurate projection method.

Development of Estimation Equations for Solid Deposition in Sewer Systems due to Rainfall (강우로 인한 관거 내 고형물 퇴적량 산정식 개발)

  • Lee, Jae-Soo;Lee, Se-Won
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.9
    • /
    • pp.885-894
    • /
    • 2008
  • The deposition of solids in combined sewer systems results in a loss of flow capacity that may restrict flow and cause a local flooding and enhanced solids deposition. In order to solve these problems and proper pipe management, estimations of solid loads on land surface in a drainage basin and solid deposition in sewer system due to rainfall are needed but these tasks are very difficult and very expensive. In this study, procedures for estimating solid loads on surface in a drainage basin were applied and analyzed in Gunja drainage basin in Korea. Also, this paper presents the development and application of estimation equation for solid deposition in sewer system due to rainfall based on the solid deposition estimated using MOUSE model. As results, the comparison between estimated and measured solid deposition is difficult due to the absent of measured data, but the estimated values using developed equations show applicability compared with the results of MOUSE model and the application of the other basin. The developed estimation equations can be used usefully for the management of combined sewer system.

Synthesis of akermanite bioceramics by solid-state reaction and evaluation of its bioactivity (고상반응법에 의한 아커마나이트 분말의 합성 및 생체활성도 평가)

  • Go, Jaeeun;Lee, Jong Kook
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.5
    • /
    • pp.191-198
    • /
    • 2022
  • Zirconia and titanium alloys, which are mainly used for dental implant materials, have poor osseointegration and osteogenesis abilities due to their bioinertness with low bioactivity on surface. In order to improve their surface bioinertness, surface modification with a bioactive material is an easy and simple method. In this study, akermanite (Ca2MgSi2O7), a silicate-based bioceramic material with excellent bone bonding ability, was synthesized by a solid-state reaction and investigated its bioactivity from the analysis of surface dissolution and precipitation of hydroxyapatite particles in SBF solution. Calcium carbonate (CaCO3), magnesium carbonate (MgCO3), and silicon dioxide (SiO2) were used as starting materials. After homogeneous mixing of starting materials by ball milling and the drying of at oven, uniaxial pressing was performed to form a compacted disk, and then heat-treated at high temperature to induce the solid-state reaction to akermanite. Bioactivity of synthesized akermanite disk was evaluated with the reaction temperature from the immersion test in SBF solution. The higher the reaction temperature, the more pronounced the akermanite phase and the less the surface dissolution at particle surface. It resulted that synthesized akermanite particles had high bioactivity on particle surface, but it depended on reacted temperature and phase composition. Moderate dissolution occurred at particle surfaces and observed the new precipitated hydroxyapatite particles in synthetic akermanite with solid-state reaction at 1100℃.

Effects of Laser Parameters and Workpiece Conditions on Cutting Characteristics of Solid Wood and Wood-based Panel(II) - Specific Cutting Energy and Surface Qualities - (레이저변수(變數)와 피삭재조건(被削材條件)이 목재(木材) 및 목질(木質)보드의 절삭특성(切削特性)에 미치는 영향(影響)(II) - 비절삭(比切削)에너지와 절삭면(切削面)의 품질(品質) -)

  • Sim, Jae-Hyeon;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.38-50
    • /
    • 1998
  • Laser cutting tests were conducted to investigate the laser cutting characteristics of solid woods such as 25mm-thick white oak(Quercus acutissima) and maple(Acer mono), and wood-based panels such as 15mm-thick medium density fiberboard and particleboard. Test variables were laser power, cutting speed, grain direction, and moisture content. Specific cutting energy was measured and the qualities of cut surface were estimated in constant laser power. Specific cutting energy of white oak was larger than that of maple, and specific cutting energy of medium density fiberboard was smaller than that of particleboard. For both white oak and maple, specific cutting energy of green wood was smaller than that of air-dried wood because weight loss of moisture evaporation in green wood was larger than that in air-dried wood. In laser-cut surface, wood cells were not deformed and damaged, but in circular saw-cut surface fibers were pushed out and cut, and wood cells were deformed severely. However, mechanical surface roughness of saw-cut surface was smoother than that of laser-cut surface because of the existence of undeformed cell cavity in laser-cut surface.

  • PDF

Solidification Analysis for Surface Defect Prediction of Rheology Forming Process Considering Flow Phenomena of Liquid and Solid Region (액상과 고상의 유동현상을 고려한 레오로지 성형공정의 표면결함예측을 위한 응고해석)

  • Seo, Pan-Ki;Jung, Young-Jin;Kang, Chung-Gil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.10
    • /
    • pp.1971-1981
    • /
    • 2002
  • Two-dimensional solidification analysis during rheology forming process of semi-solid aluminum alloy has been studied. Two-phase flow model to investigate the velocity field and temperature distribution is proposed. The proposed mathematical model is applied to the die shape of the two types. To calculate the velocities and temperature fields during rheology forming process, the each governing equations correspondent to the liquid and solid region are adapted. Therefore, each numerical model considering the solid and liquid coexisting region within the semi-solid material have been developed to predict the defects of rheology forming parts. The Arbitrary Boundary Maker And Cell(ABMAC) method is employed to solve the two-Phase flow model of the Navier-Stokes equation. Theoretical model basis of the two-phase flow model is the mixture rule of solid and liquid phases. This approach is based on using the liquid and solid viscosity. The Liquid viscosity is pure liquid state value, however solid viscosity is considered as a function of the shear rate, solid fraction and power law curves.

Simultaneous Determination and Occurrences of Pharmaceuticals by Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) in Environmental Aqueous Samples

  • Koo, So-Hyun;Jo, Cheon-Ho;Shin, Sun-Kyoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1192-1198
    • /
    • 2010
  • Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in the aquatic environment. Many pharmaceuticals are not completely removed during wastewater treatment, leading to their presence in wastewater treatment effluents, rivers, lakes, and ground water. Here, we developed analytical methods for monitoring ten pharmaceuticals from surface water by LC/ESI-MS/MS. For sample clean-up and extraction, MCX (mixed cation exchange) and HLB (hydrophilic-lipophilic balance) solid-phase extraction (SPE) cartridges were used. The limits of detection (LOD) in distilled water and the blank surface water were in the range of 0.006 - 0.65 and 1.66 - 45.05 pg/mL, respectively. The limits of quantitation (LOQ) for the distilled water and the blank surface water were in the range of 0.02 - 2.17 and 5.52 - 150.15 pg/mL, respectively. The absolute recoveries for fortified water samples were between 62.1% and 125.4%. Intra-day precision and accuracy for the blank surface water were 2.9% - 24.1% (R.S.D.) and -16.3% - 16.3% (bias), respectively. In surface wastewater near rivers, chlortetracycline and acetylsalicylic acid were detected frequently in the range of 0.017 - 5.404 and 0.029 - 0.269 ng/mL, respectively. Surface water near rivers had higher levels than surface water of domestic treatment plants.