• 제목/요약/키워드: Solar power plants

검색결과 134건 처리시간 0.024초

후처리를 이용한 $CO_2$ 포집이 화력 발전설비 성능에 미치는 영향 해석 (Analysis of the Influence of Post-Combustion $CO_2$ Capture on the Performance of Fossil Power Plants)

  • 탁상현;김동섭;장영수;이대영;김민성
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.545-552
    • /
    • 2010
  • Research and development efforts to reduce $CO_2$ emission are in progress to cope with global warming. $CO_2$ emission from fossil fuel fired power plants is a major greenhouse gas source and the post-combustion $CO_2$ capture is considered as a short or medium term option to reduce $CO_2$ emissions. In this study, the application of the post-combustion $CO_2$ capture system, which is based on chemical absorption and stripping processes, to typical fossil fuel fired power plants was investigated. A coal fired plant and a natural gas fired combined cycle plant were selected. Performance of the MEA-based $CO_2$ capture system combined with power plants was analyzed and overall plant performance including the energy consumption of the $CO_2$ capture process was investigated.

태양열과 지열을 이용한 난방용 공기순환시스템 기초연구 - 태양열을 이용한 트롬월식의 축열성능 중심으로 - (A Basic Study on the Air Circulation System for Heating using Solar and Geothermal Heat - Focused on Trombe Wall Thermal Storage Performance using Solar Heat -)

  • 김병윤;최용석
    • 한국농촌건축학회논문집
    • /
    • 제19권4호
    • /
    • pp.49-56
    • /
    • 2017
  • Each country in the world currently concentrates on shifting into clean energy, which can be alternative energy, for global environment protection and solution to the problem of fossil fuel depletion. The Korean government is predicted to develop renewable energy, such as solar power, ground power, and offshore wind power, and to increase their supply ratios by ending the use of coals and nuclear power plants. This study conducted experiments on thermal storage performance of Trombe wall thermal storage materials using solar power and simulations in order to offer baseline data for the development of a hybrid air circulation system for heating that can maximize efficiency by simultaneously using solar and geothermal power. The study results are as follows: (1) In all the specimens with 3m, 5m, and 7m in the length of thermal storage pipe, $5.7^{\circ}C$, $7.8^{\circ}C$, and $10.5^{\circ}C$ rose, respectively, as the thermal storage effect of the specimens attaching insulation film and black tape to the general funnel. They were most excellent in terms of thermal storage effect. (2) As a result of thermal performance evaluation on the II type specimens, II-3 ($7.8^{\circ}C$ rise) > II-4 ($5.3^{\circ}C$ rise) > II-1 ($3.9^{\circ}C$ rise) > II-2 ($2.3^{\circ}C$ rise) was revealed, and thus II-3 (insulation film + black tape) was most effective as shown in the I type. (3) This study analyzed air current and temperature distribution inside of the greenhouse by linking actually measured values and simulation interpretation results through the interpretation of CFD (computational fluid dynamics). As a result, the parts absorbing heat and discharging heat around the thermal storage pipe could be visibly classified, and temperature distribution inside of the greenhouse around the thermal storage pipe could be figured out.

독립형 소형 풍력발전시스템 구성 및 운전특성 (Configuration and Operation characteristics of a Small stand-alone Wind Power Generation System)

  • 황인호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.65-68
    • /
    • 2002
  • Most of the present demand in the world is met by fossil and nuclear power plants. A small part is met by renewable energy technologies. Among the renewable power sources, wind and solar energy have experienced a remarkably rapid growth in the past 10 years. Recently the utilization of wind power has been receiving close attention in this country, especially for the electrification of off-shore islands. The objective of this study is to demonstrate a small wind energy system as a stand-alone power source.

  • PDF

GIS를 이용한 태양광시설 설치를 위한 적정지역 선정에 관한 연구 (A Study for Planning Optimal Location of Solar Photovoltaic Facilities using GIS)

  • 윤성욱;백이;장재경;최덕규;강동현;손진관;박민정;강석원;권진경
    • 생물환경조절학회지
    • /
    • 제28권3호
    • /
    • pp.243-254
    • /
    • 2019
  • 본 연구에서는 전국을 대상으로 태양광에너지와 관련된 기상 및 지형 대리변수를 고려하여 태양광발전 시설에 대한 취약지역을 분석하였으며, GIS를 이용하여 공간분석을 통해 태양광발전 시설의 적정입지에 대한 평가용 지도를 개발하였다. 본 연구에서 최종적으로 개발된 태양광발전 시설에 대한 취약지도에서는 '취약단계 5(매우 취약)' 지역과 '취약단계 1(매우좋음)' 지역은 나타나지 않았다. '취약단계 4(취약)' 지역은 전라남도가 가장 크게 나타났으며, '취약단계3(보통)' 지역은 광주광역시, 전라북도, 충청북도 및 강원도 등 다수의 행정구역에서 높은 것으로 나타났다. '취약단계 2(좋음)' 지역은 대구광역시, 울산광역시 및 인천광역시 등이 높은 것으로 나타났다. 현재 운영되고 있는 태양광발전소 30곳을 비교 검토한 결과, 대부분 취약단계 2 및 3단계 지역에 위치하며, 상대적으로 태양광에너지가 적합한 지역에 위치함을 나타냈다. 하지만 본 연구의 한계점인 태양광발전소의 제한적인 자료량으로 인해 본 연구결과의 정확성을 명확하게 평가하기는 어렵다. 그럼에도 불구하고 본 연구에서는 GIS 공간분석 기법을 이용하여 다양한 기상 및 지형요소들을 고려하여 전국을 대상으로 태양광발전시설에 대한 취약지도 평가를 시도하였으며, 국내 전 지역에 대한 자료를 제시함으로써 태양광발전과 관련된 부분에 기초자료로 활용할 수 있을 것이다.

How to Avoid Severe Incidents at Hydropower Plants

  • Yasuda, Masashi;Watanabe, Satoshi
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권3호
    • /
    • pp.296-306
    • /
    • 2017
  • Hydropower is now changing its role from the energy generator into the most powerful and reliable tool for stabilizing the electrical network, especially under the increase of intermittent power sources like wind-power and solar-power. Although the hydropower plants are the most robust generating facilities, they are not immune from unexpected severe incidents having long downtime, considerable restoration cost and sometimes fatalities. The present paper provides some study results about severe incidents in the conventional hydropower plants, mainly about the flood, fire and electro-mechanical troubles, except for the incidents of civil facilities. It also provides some possible scenarios which may lead some measures how to avoid such incidents. Finally, it provides some comprehensible recommendations to avoid severe incidents based on experiences.

농촌지역 태양광에너지 도입을 위한 공공데이터 활용방안 (Study on the Utilization of Public Data for the Introduction of Solar Energy in Rural Areas)

  • 김상범;김용균
    • 농촌계획
    • /
    • 제29권4호
    • /
    • pp.175-182
    • /
    • 2023
  • The purpose of this study, the trend of renewable energy, domestic and foreign renewable energy policies, and the flow of the legal system related to renewable energy location were identified, and a location analysis using public data was studied when solar energy was located. First, renewable energy is leading to energy conversion by reducing the proportion of existing fossil fuel-centered energy sources in the global trend and increasing the proportion of renewable energy, an eco-friendly energy source, and changing the institutional and market structure. Second, large-scale solar energy power plants are installed and operated in rural areas where there is no change in insolation and land prices are cheaper than in urban areas where there are many changes in insolation due to surrounding high-rise buildings and street trees. Third, if a preliminary location review is conducted using public data at this time, it will be easy to identify the optimal location for area and size calculation. Fourth, the solar energy location functional area was studied in area A, and the total area of the target area was 624.5km2, with 392.7km2 and 62.9% of the avoidance area where solar power cannot be located.

UAV 추진기관의 종류 및 특성에 관한 기술적 고찰 (Technical Survey on the Classification and Characteristics of UAV's Power Plant)

  • 이동훈;팽기석;김유일;박부민;최성만;허환일
    • 한국추진공학회지
    • /
    • 제14권3호
    • /
    • pp.79-86
    • /
    • 2010
  • 현재 운용중인 UAV 추진기관의 종류 및 각각의 특징과 장단점들을 살펴보았다. 전기추진을 위한 에너지원과 내연기관 추진의 동력원을 상호 비교하였으며, 미래의 UAV에 적합한 추진기관들의 성능 요구 조건을 분석, 제시하였다.

태양광 발전소와 부동산 자산 운용 수익의 경제성 평가에 대한 연구 (Study on Economic Evaluation of Solar Power Plant and Real Estate Asset Management Revenues)

  • 우제택;서미자;이재환
    • 한국전자통신학회논문지
    • /
    • 제13권3호
    • /
    • pp.633-642
    • /
    • 2018
  • 태양광발전소는 급속한 보급을 거듭하며 민간 중심의 부동산 개발과 함께 건물의 부대시설 및 토지, 산악지역과 염전 부지 등 다양한 형태로 수익화 운영을 지속하고 있다. 최근의 태양광발전소는 발전단가의 하락에도 불구하고 주요 설비의 가격 대중화와 기술의 안정화로 발전소 구축이 다시 활발해지고 있다. 그러나 시공에 대한 비용투자와 발전소 운영 수익의 손익분기를 바탕으로 전통적인 부동산 자산 운용과의 수익성 비교검토는 부족한 실정으로 본 논문에서는 부동산 자산운용의 보편화된 형태로 오피스텔과 상가 투자를 바탕으로 태양광 발전시스템의 경제성을 분석하기 위한 검토와 연구를 진행 하였다.

밸러스트 수 이동으로 태양을 추적하는 부유식 태양광 발전시스템 개발 (Note on the Development of Ballast Water Shifting System for Solar Tracking of the Floating Photovoltaic Plant)

  • 오정근;김준호;김승섭;김효철;류재문
    • 대한조선학회논문집
    • /
    • 제53권4호
    • /
    • pp.290-299
    • /
    • 2016
  • The most powerful energy resource in nature is solar energy which becomes directly converted to electric power in worldwide. Most of the photovoltaic power plants are commonly installed on sunny side of the ground. Thus the installation of photovoltaic power plant could produce an unexpected adverse effect by sacrificing the productivity from green field or forest. To avoid these adverse effect floating photovoltaic plant has been devised and installed on inland reservoir. The photovoltaic plant could utilize ignored water surface without sacrificing the productivity of the ground. Additionally the photovoltaic efficiency has been reenforced by the cooling effect induced by the circulating air flow from water surface. The floating photovoltaic plant could be furnished solar tracking ability by tilting the system operated with the aid of the ballast system. This report is provided to introduce the design of the floating structure with solar panel which furnished solar tracking ability with the aid of ballast system.

소수력발전입지의 수문학적 성능특성 (Hydrologic Performance Characteristics of Small Scale Hydro Power Site)

  • 박완순;이철형
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.135-142
    • /
    • 2007
  • The model to predict flow duration characteristics and performance for small scale hydro power(SSHP) plants is studied to analyze the effects of rainfall condition. One existing SSHP plant was selected and performance characteristics was analyzed by using the developed model. The predicted results from the model developed show that the data were in good agreement with operational results of existing SSHP plant. The results show that both the scale parameter and the shape parameter have large effects on the performance of SSHP sites. And also it was found that the model developed in this study can be a useful tool to predict the performance of SSHP sites.