• 제목/요약/키워드: Solar insolation

검색결과 254건 처리시간 0.024초

청과물 저온저장고의 설계에 관한 연구 (1) -자연환기를 이용한 제주산밀감저장고의 설계- (On the Design of Cold Storage for Fruits and Vegetables (1) -Design of Natural Ventilating Type Store for Citrus Furits in Jejudo-)

  • 허종화;김효경
    • 대한설비공학회지:설비저널
    • /
    • 제5권4호
    • /
    • pp.272-280
    • /
    • 1976
  • A natural ventilating type store was designed for the economic and effective storage of citrus fruits in Jejudo. The material used for the wall is scoria, widely distributed in Jejudo and known for high strength and insulation. Design condition was chosen for the period till March of a year and the dry bulb temperature was taken from TAC $5\%$ base. The temperature of the store can be maintained below the limiting temperature of $8^{\circ}C$ for the time length of $7\frac{1}{2}$ hours under the condition of the atmospheric temp, $15.3^{\circ}C$ and the solar insolation. The limiting temperature can he recovered to the initial temperature $(7^{\circ}C)$ by the natural ventilation for 8 hours in the night.

  • PDF

인공 신경망과 퍼지를 이용한 최대 전력점 추적을 위한 모델 (Model for Maximum Power Point Tracking Using Artificial Neural Network and Fuzzy)

  • 김태오;하은규;김창복
    • 한국정보기술학회논문지
    • /
    • 제17권9호
    • /
    • pp.19-30
    • /
    • 2019
  • 태양광 발전은 일사량 및 온도 등 외부변화에 따른 안정적이고 효율적인 최대 전력 출력 전력점을 추적하기 위한 MPPT 알고리즘이 필요하다. 본 연구는 인공 신경망을 이용하여 기존 MPPT 알고리즘보다 신속하게 MPP를 추적할 수 있는 모델을 구현하였다. 제안 모델은 인공 신경망의 학습 데이터를 위해 다양한 일사량과 온도의 조합에 대해서 기존 MPPT 알고리즘으로 MPP의 전류와 전압을 찾았다. 획득한 MPP 데이터는 입력 노드를 일사량과 온도로 출력 노드를 전류와 전압으로 하여 학습하였다. 실험결과 일사량과 온도 변화가 있는 0~0.3t 구간에서 추적시간은 기존 알고리즘인 P&O와 InC 그리고 Fuzzy는 각각 잘못된 계산식t, 0.49t 그리고 0.4076t이였으며, 제안 모델은 0.32511t로서 기존 알고리즘 보다 0.1t 이상 신속하게 MPP를 추적하였다.

데이터를 활용한 태양광 발전 시스템 모듈온도 및 발전량 예측 (Prediction of module temperature and photovoltaic electricity generation by the data of Korea Meteorological Administration)

  • 김용민;문승재
    • 플랜트 저널
    • /
    • 제17권4호
    • /
    • pp.41-52
    • /
    • 2021
  • 본 연구에서는 태양광발전 출력 및 모듈온도 값을 기상청 데이터를 이용하여 예측해보고 실측 데이터와 날씨, 일사량, 주변온도, 풍속별로 비교 분석해보았다. 날씨별 예측정확도는 눈이 오거나, 새벽에 해무가 끼는 날의 데이터를 가장 많이 보유한 맑은날의 데이터의 예측정확도가 가장 낮았다. 일사량에 따른 모듈온도와 발전량의 예측정확도는 일사량이 커질수록 정확도가 떨어졌으며, 주변 온도에 따른 예측정확도는 모듈온도는 주변 온도가 커질수록, 발전량은 주변온도가 낮을수록 예측정확도가 떨어졌다. 풍속은 모듈온도와 발전량 모두 풍속이 높아질수록 예측정확도가 감소하였지만, 풍속이 영향 다른 기상조건에 의한 영향보다 미미하여 그 상관관계를 정의하기가 어려웠다.

RTDS를 이용한 단독운전 태양광 발전시스템의 실시간 시뮬레이션 (A Real-Time Simulation Method for Stand-Alone PV Generation Systems using RTDS)

  • 김봉태;이재득;박민원;성기철;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.190-193
    • /
    • 2001
  • In order to verify the efficiency or availability and stability of photovoltaic(PV) generation systems, huge system apparatuses are needed, in general, in which an actual size of solar panel, a type of converter system and some amount of load facilities should be installed in a particular location. It is also hardly possible to compare a Maximum Power Point Tracking (MPPT) control scheme with others under the same weather and load conditions in an actual PV generation system. The only and a possible way to bring above-mentioned problem to be solved is to realize a transient simulation scheme for PV generation systems using real weather conditions such as insolation and surface temperature of solar cell. The authors, in this paper, introduces a novel simulation method, which is based on a real-time digital simulator (RTDS), for PV generation systems under the real weather conditions. Firstly, VI characteristic equation of a solar cell is developed as an empirical formula and reconstructed in the RTDS system, then the real data of weather conditions are interfaced to the analogue inputs of the RTDS. The outcomes of the simulation demonstrate the effectiveness of the proposed simulation scheme in this paper. The results shows that the cost effective verifying for the efficiency or availability and stability of PV generation systems and the comparison research of various control schemes like MPPT under the same real weather conditions are possible.

  • PDF

평판형 액체식 집열기 의 각종 변수 가 집열기 의 열성능 에 미치는 영향 (A Study of Parametric Effects on the Thermal Performance of Flat-Plate Liquid-Heating Solar Collectors)

  • 전문헌;윤석범;추교명
    • 대한기계학회논문집
    • /
    • 제8권2호
    • /
    • pp.145-153
    • /
    • 1984
  • 본 연구에서는 먼저 집열기의 열성능에 관한 가장 전형적인 Hottel-Whillier- Bliss의 모델을 사용하여 모의 실험을 수행하였다. 모의 실험에 사용한 집열기의 주 요 변수는 덮개 유리의 수(N), 집열판의 방사율(.epsilon.$_{p}$), 집열판의 흡수율(.alpha.$_{p}$T),집열기 단위 면적당의 유량(G), 집열기 단열재의 $L_{b}$/ $K_{b}$, 집열기 경사각 (S),일사량(I) 등이며 이들 집열기 변수의 대표치(typical values)를 중심으로 각 변 수의 값을 변화시켜서 여기에 따른 집열기 효율 곡선의 변화를 조사하였다. 모의 실 험결과와 비교하고, 모의 실험에 사용한 수학적 모델이 집열기의 열성능을 평가하는 데에 적합한가를 확인하고, 운전중에 인위적으로 그 값을 조절할 수 있는 운전 변수중 특히 유량(G)의 변화에 따른 집열기 효율변화와 최적유량의 범위를 동시에 실험적으로 조사하기 위하여, 액체 가열식 집열기 시험장치의 회로를 보완하여 실제 태양 아래에 서 실험을 수행하였다.

주거용 건물 태양광발전시스템의 설치유형에 따른 발전성능 평가 (Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings)

  • 김덕성;김법전;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제37권2호
    • /
    • pp.35-45
    • /
    • 2017
  • The types of installation of the photovoltaic system applied to domestic residential buildings are classified as follows: Mounted modules with air circulation, semi-integrated modules with air duct behind, integrated modules with fully insulated back. In order to study generation characteristics of PV system, we verified the validity of interpretation program based on long-term measurement data of demonstration house installed in BAPV form and also analyzed the generation characteristics and performance of each installation type. The results are as follows. First, the RMSE of amount of generation and simulation according to annual daily insolation of demonstration system located in Daejeon was 0.98kWh and the range of relative error of monthly power generation was -5.8 to 3.1. Second, the average annual PR of mounted modules was 82%, semi-integrated modules 76.1% and integrated modules 71.9%. This differences were attributed to temperature loss. Third, the range of operating temperature of annual hourly photovoltaic modules was -6.5 to $61.0^{\circ}C$ for mounted modules, $-6.0{\sim}73.9^{\circ}C$ for semi-integrated modules and -5.5 to $88.9^{\circ}C$ for integrated modules. The temperature loss of each installation type was -14.0 to 16.1%, -13.8 to 21.9%, and -13.6 to 28.5%, respectively.

공동주택 단지 배치유형별 PV시스템 최적 설치면적 및 전기부하 기여율 평가 연구 (A Study on the Power Saving Fraction of Site Electrical Load depending on the installation area of PV system in Apartment Complex)

  • 윤종호;박재성;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제28권3호
    • /
    • pp.60-66
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex through the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performed with the hourly simulations of total received insolation on each surface considering the shading effect of buildings. Electrical load profile of typical Korean apartments were investigated for the load matching analysis. To calculate an annual total PV output, we used MERIT program which is a hourly based load matching tool developed by ESRD. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending on a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡtype revealed the best option for the maximum output of PV system.

전력 IT 시스템에서 복합방식의 태양광 발전량 예측 방법 제안 (Suggestion of a Hybrid Method for Estimating Photovoltaic Power Generation)

  • 주우선;장민석;이연식;배석찬;김원구
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.782-785
    • /
    • 2011
  • 최근 세계적으로 에너지원의 고갈, 전력 수요 증가, 기후 환경 변화에 대처하기 위해 신재생에너지원을 활용한 마이크로그리드 개발의 필요성이 점증하고 있다. 특히 태양광 발전은 댁내에 설치하기 용이한 가장 일반적인 신재생에너지원의 하나로써 각광받고 있다. 하지만 태양광은 기후 변화(일사량 및 일조량의 변화)에 따라 출력이 불안정하다는 단점으로 인해, 균일한 전력품질을 제공하기 위해 해결해야 할 기술적인 과제를 가지고 있다. 이 문제의 해결책으로써 에너지저장장치(ESS)이 고려되고 있지만, 이것도 용량이란 한계점을 가지고 있다. 이 문제를 해결하는 방법으로써 본 논문에서는 2가지 기후 요소인 일조량과 일사량에 따른 태양광 발전량을 추정하는 복합적인 방법을 제안한다. 이 연구 결과는 ESS의 정적 용량을 설계하는데 도움을 줄 수 있으며, 댁내 전력 IT 시스템에서 DC/AC 전력 스위칭의 적절한 타이밍을 제공하는데 도움을 줌으로써 전력품질의 균일성을 유지할 수 있도록 해줄 것으로 기대된다.

  • PDF

태양에너지를 이용한 유용목재의 건조 (Seasoning of Commercial Wood Using Solar Energy)

  • 정희석;이형우;이남호;이상봉
    • Journal of the Korean Wood Science and Technology
    • /
    • 제16권4호
    • /
    • pp.10-39
    • /
    • 1988
  • This study investigated the temperatures and relative humidities in the semi-greenhouse type solar dryer with a black rock-bed heat storage and without heat storage and outdoor temperature and relative humidity at 9 a.m. and 2 p.m.. A comparison was made of the drying rates, final moisture contents, moisture content distributions, casehardening stresses, drying defects, volumetric shrinkage of dried lumber for solar- and air-drying from the green condition of mixtures of Douglas-fir, lauan, taun, oak and sycamore 25mm- and 50 mm-thick lumber during the same period for four seasons, and heat efficiencies for solar dryer with and without the heat storage for saving of heat energy and the cost of lumber drying using the solar energy. The results from this study were summarized as follows: I. The mean weekly temperatures in the solar dryers were 3 to $6^{\circ}C$ at 9 a.m. and 9 to $13^{\circ}C$ at 2 p.m. higher than mean outdoor temperature during all the drying period. 2. The mean weekly relative humidities in the solar dryers were about 1 to 19% at 9 a.m. higher than the outdoor relative humidity. and the difference between indoor and outdoor relative humidity in the morning was greater than in the afternoon. 3. The temperatures and relative humidities in the solar dryer with and without the heat storage were nearly same. 4. The overall solar insolation during the spring months was highest and then was greater in the order of summer, atumm, and winter month. S. The initial rate of solar drying was more rapid than that of air drying. As moisture content decreased, solar drying rate became more rapid than that of air drying. The rates of solar drying with and without heat storage were nearly same. The drying rate of Douglas-fir was fastest and then faster in the order of sycamore, lauan, taun and oak. and the faster drying rate of species, the smaller differences of drying rates between thicknesses of lumber. The drying rates were fastest in the summer and slowest in the winter. The rates of solar drying during the spring were more slowly in the early stage and faster in the later stage than those during the autumn. 6. The final moisture contents were above 15% for 25mm-thick air dried and about 10% for solar dried lumber, but the mean final MCs for 50mm-thick lumber were much higher than those of thin lumber. The differences of final MC between upper and lower course of pile for solar drying were greater than those of pile for air drying. The differences of moisture content between the shell and the core of air dried lumbers were greater than those of solar dried lumber, smallest in the drying during summer and greatest in the drying during winter among seasons. 7. Casehardening stresses of 25mm- and 50mm-thick dried lumber were slight, casehardening stress of solar dried lumber was severer than that of air dried lumber and was similar between solar dried lumber with and without heat storage, Casehardening stresses of lumber dried during spring were slightest and then slighter in the order of summer, autumn, and winter. Casehardening stresses of Douglas -fir, sycamore and lauan were slight, comparing with those of taun and oak. 8. Maximum initial checks of 25mm-thick lumber occurred above and below fiber saturation point and those of 50mm-thick lumber occurred in the higher moisture content than thin lumber. As the moisture content decreased, most of checks were closed and didn't show distinct difference of the degree of checks among drying methods. The degree of checks were very slight in case of Douglas-fir and lauan, and severe in case of taun and oak. The degree of checks for 50mm-thick lumber were severer than those for 25mm-thick lumber. 9. The degree of warpage showed severe in case of oak and sycamore lumber, but no warping was found in case of Douglas-fir, lauan and taun. 10. The volumetric shrinkages of taun and oak were large and medium in case of Douglas-fir, lauan and sycamore. 11. Heat efficiencies of solar dryer with heat storage were 6.9% during spring, 7.7% during summer, 12.1% during autumn and 4.1% during winter season. Heat efficiency of solar dryer with heat storage was slightly greater than that of without heat storage. As moisture content of lumber decreased, heat efficiency decreased.

  • PDF

한옥의 경사처마와 이중바닥구조에 관한 연구 (A Study on the inclined balcony and double deck structure of Korean traditional housing)

  • 노영숙;김정원
    • 한국산학기술학회논문지
    • /
    • 제16권12호
    • /
    • pp.8408-8415
    • /
    • 2015
  • 본 논문은 공동주택에 적용 가능한 한옥구조 평면기술에 관한 연구로서, 한옥의 특징들을 구조적, 기능적 측면으로 분석하여 이를 공동주택 평면에 적용하는 방안을 제안하였다. 기존 지붕처마 각도를 중심으로 하지, 동지의 남중고도를 반영한 실내 일사깊이를 계산하여 효율적인 슬래브 경사 및 층고를 갖는 경사발코니 구조를 제안하였다. 이는 해당 슬래브 하부층에 적용되는 것으로 기존의 단층적인 한옥의 한계를 극복하여 모든 층의 동일한 일사량 및 전망권을 제공할 수 있으며 한옥의 정원개념을 수직공동주택에 적용가능하게 해준다. 전통 한옥의 처마 내밀기와 귀솟음을 응용한 경사발코니의 각도는 30o도 내외가 적당하고, 층고는 $4.5{\pm}0.25m$가 경제적인 것으로 분석되었다. 또한 기존 한옥의 뜬 바닥 구조를 분석하여 소음, 진동, 온도 전달에 관련된 원리들을 공동 주택 평면에 적용 가능하도록 개선안을 모색하였으며 기존 공동주택과 달리 복층바닥구조는 단일슬래브에 비하여 바닥충격음 66%정도 저감되는 것으로 나타났다. 이중바닥구조는 주택 평면에서 사라지고 있는 수직적 공간(다락 및 하부저장공간)을 제공함으로써 효율적인 내.외부 공간관리가 가능한 것으로 나타났다.