• 제목/요약/키워드: Solar Cell System

검색결과 789건 처리시간 0.031초

EMTP형 시뮬레이터를 이용한 태양광발전시스템 모의 방법 (Simulation Method of Photovoltaic Generation Systems using EMTP Type Simulators)

  • 박민원;유인근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권6호
    • /
    • pp.303-308
    • /
    • 2005
  • As the cost of photovoltaic(PV) generation systems continues to decrease, utility interactive systems are becoming more economically viable. Furthermore, increases in consumer awareness correspond to a willingness to pay a premium price for clean electrical energy generated using renewable energy resources. Especially, PV generation systems, in particular, is undergoing a rapid expansion-showing an industrial growth of approximately 40$\%$ per year in the worldwide, as PV cell and systems technology improve new markets become increasingly accessible. This has resulted in an increased demand for the simulation scheme and operational technologies of utility interactive PV devices and systems. The simulation schemes that can be applied to the utility interactive PV generation systems readily and cheaply under various conditions considering the sort of solar cell, the capacity of systems and the converter system as well are strongly expected and emphasized among researchers. So far, authors have been introducing the simulation method of PV generation systems with several papers. In this paper, authors introduce the simulation way of PV generation systems using EMTP type simulators; EMTP/ATP, EMTDC/PSCAD, RTDS, with each examples. And, by connecting the voltage amplifier to the RTDS a novel simulation method which is extremely close to the real condition of PV generation system is also introduced.

A Novel MPPT Control of a Photovoltaic System using an FLC Algorithm

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.17-25
    • /
    • 2014
  • This paper proposes a novel maximum power point tracking (MPPT) system using a fuzzy logic control (FLC) algorithm for robust in-environment changing. The power available at the output of a photovoltaic (PV) cell continues to change with radiation and temperature because a solar cell exhibits nonlinear current-voltage characteristics. Therefore, the maximum power point (MPP) of PV cells varies with radiation and temperature. The MPPT methods are used in PV systems to make full utilization of the PV array output power, which depends on radiation and temperature. The conventional MPPT control methods such as constant voltage (CV), perturbation and observation (PO) and incremental conductance (IC) have been studied but these methods are problematic in that they fail to take into account the changing environment. The proposed FLC controller is based on the fuzzy control algorithm and facilitates robust control with the environmental changes. Also, the PV systems applied FLC controller is modeled by PSIM and the response characteristics of the FLC method according to environmental variations are analyzed through comparison with the performance of conventional methods. The validity of this controller is shown through response results.

Enrichment of Hydrogenotrophic Methanogens in Coupling with Methane Production Using Electrochemical Bioreactor

  • Jeon, Bo-Young;Kim, Sung-Yong;Park, Yong-Keun;Park, Doo-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권12호
    • /
    • pp.1665-1671
    • /
    • 2009
  • Anaerobic digestion sludge was cultivated in an electrochemical bioreactor (ECB) to enrich the hydrogenotrophic methanogens. A modified graphite felt cathode with neutral red (NR-cathode) was charged with electrochemical reducing power generated from a solar cell. The methane and carbon dioxide collected in a Teflon bag from the ECB were more than 80 ml/l of reactant/day and less than 20 ml/l of reactant/day, respectively, whereas the methane and carbon dioxide collected from a conventional bioreactor (CB) was around 40 ml/l of reactant/day, respectively. Moreover, the maximal volume ratios of methane to carbon dioxide (M/C ratio) collected in the Teflon bag from the ECB and CB were 7 and 1, respectively. The most predominant methanogens isolated from the CB on the $20^{th}$, $80^{th}$, and $150^{th}$ days of incubation were hydrogenotrophs. The methanogenic diversity analyzed by temperature gradient gel electrophoresis (TGGE) of the 16S rDNA variable region was higher in the ECB than in the CB. The DNA extracted from the TGGE bands was more than 95% homologous with hydrogenotrophic methanogens in the ECB, but was an aceticlastic methanogen in the CB. In conclusion, the ECB was demonstrated as a useful system for enriching hydrogenotrophic methanogens and increasing the M/C ratio of the gas product.

신재생에너지 산업 기술 정책의 투자효과 분석에 대한 기초 연구 (The Basic Study on the Ripple Effect of Industrial & Technological Policy for New & Renewable Energy)

  • 김정배
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.18-24
    • /
    • 2012
  • This study is to propose the quantitative methods instead of total results on New & Renewable energy R&D investments. To do that, this study used KETEP R&D investment profile, National R&D investment profile, and ISTANS industrial census results. From the analysis, this study firstly showed that the R&D investment on New&Renewable energy is higher than that of other industrial parts. And the investment increase ratio on New&Renewable energy is also very higher during past 10 years. And finally showed that the ripple effects(relatively the employee number, the amount of sales, and the amount of export) of the focus energy group including feul cell, photovoltaic, and wind power was higher than those of general manufacturing industry. This approach was firstly conducted using the poor census results, so other analysis methods will be developed and performed to exact;y show the investment ripple effect.

건물일체형 투명 PV복층창의 설치조건에 따른 단위출력당 발전특성 분석연구 (A Study on the Power Performance Measurement of Transparent Thin-film PV Windows of BIPV Depending on the Inclined Angle)

  • 안영섭;송종화;김석기;이성진;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.55-60
    • /
    • 2008
  • This study is on the analysis of power output of transparent thin-film PV windows which are integrated into the building envelope instead of traditional windows. 3 installation angles of vertical, horizontal and $30^{\circ}C$ inclination are investigated. To measure power output of PV windows, full scale mock-up house was designed and constructed. The power performance of PV window system was analyzed for horizontal angle, declination angle and vertical angle according to incline angle. Monitoring data are gathered from November 2006 to August 2007 and statistical analysis is performed to analysis a characteristics of power performance of transparent PV windows. Results show that annual power output of PV window with horizontal angle is 844.4kWh/kWp/year, declination angle 1,060kWh/kWp/year and vertical angle 431.6 kWh/kWp/year.

  • PDF

$H_2$ plasma treatment effects on electrical and optical properties of the BZO (ZnO:B) thin films

  • Yoo, Ha-Jin;Son, Chan-Hee;Choi, Joon-Ho;Kang, Jung-Wook;Cho, Won-Tae;Park, Sang-Gi;Lee, Yong-Hyun;Choi, Eun-Ha;Cho, Guang-Sup;Kwon, Gi-Chung
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.309-309
    • /
    • 2010
  • We have investigated the effect of $H_2$ plasma treatment on the BZO (ZnO:B, Boron doped ZnO) thin films. The BZO thin films are prepared by LP-MOCVD (Low Pressure Metal Organic Chemical Vapor Deposition) technique and the samples of BZO thin film are performed with $H_2$ plasma treatment by plasma treatment system with 13.56 MHz as RIE (Reactive Ion Etching) type. After exposing $H_2$ plasma treatment, measurement of transmittance, reflectance and haze spectra in 300~1100 nm, electrical properties as resistivity, mobility and carrier concentration and work function was analysed. Regarding the results of the $H_2$ plasma treatment on the BZO thin films are application to the TCO for solar cells, such as the a-Si thin films solar cell.

  • PDF

후면 환기조건에 따른 건물외피용 태양광발전(BIPV) 모듈의 열적 영향에 관한 실험연구 (Experimental Study on the Thermal Effect of BIPV Modules Depending on the Ventilation Type of PV Module Backside)

  • 윤종호;김재웅
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.81-89
    • /
    • 2006
  • Building integrated photovoltaic (BIPV) system operates as a multi-functional building construction material. They not only produce electricity, but also are building integral components such as facade, roof, window and shading device. On the other hands lots of architectural considerations should be reflected such as Installation position, shading, temperature effect and so on. As PV modules function like building envelope in BIPV, combined thermal and PV performance should be simultaneously evaluated This study is on the combined thermal and PV performance evaluation of BIPV modules. The purpose of this study is to investigate a temperature effect of PV module depending on the ventilation type of PV module backside. Test cell experiment was performed to identify the thermal and power effect of PV modules. Measurement results on the correlation of temperature and power generation were obtained. Those results can be utilized for the development of optimal BIPV installation details in the very early design stage.

펄스형 Nd:YAG 레이저를 이용한 FTO 식각에 대한 연구 (A Study on the Scribing of FTO using Pulsed Nd:YAG Laser)

  • 김희제;박성준;손민규;이동길;이경준
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1407-1411
    • /
    • 2008
  • In material processing, a laser system with optimal laser parameters has been considered to be significant. Especially, the laser scribing technology is thought to be very important for fabricating DSSC(Dye sensitized solar eel!) modules with good quality. Moreover, the $TEM_{00}$ mode laser beam is the most dominant factor to decide the IPCE(Incident photon to current conversion efficiency) characteristics. In order to get the $TEM_{00}$ mode, a pin-hole is inserted within a simple pulsed Nd:YAG laser resonator. And the spatial field distribution is measured by using three size pin-hole diameters of 2.0, 6.0mm respectively. At that moment, each case has the same laser beam energy by adjusting the discharge voltage and pps(pulse per second). From those results, it is known that the pin-hole size of 2.0mm has the perfect $TEM_{00}$ mode. In addition, at the charging voltage of 1000V, 10pps and the feeding speed of 1.11mm/sec, the SEM photo of FTO(Fluorine-doped tin oxide) thin film layers shows the best scribing trace.

박막태양전지 하부전극용 Mo 박막특성 연구 (A Study on properties of Lower Electrode thin films solar cell for Mo thin film)

  • 양현훈;김영준;정운조;박계춘
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.321-322
    • /
    • 2007
  • In order to increase the cost effectiveness of solar cells, module production should be treated more comprehensively. Back contact cells offer distinct advantage in the interconnection of cells to modules. Thereby Mo thin film were prepared in order to clarify optimum conditions for growth of the thin film depending upon process, and then by changing a number of deposition conditions and substrate temperature conditions variously, structural and electrical characteristics were measured. For the manufacture of the Mo were vapor-deposited in the named order. Among them, Mo were vapor-deposited by using the sputtering method in consideration of their adhesive force to the substrate, and the DC power was controlled so that the composition of Mo, while the surface temperature having an effect on the quality of the thin film was changed from R.T$[^{\circ}C]$ to $200[^{\circ}C]$ at intervals of $50[^{\circ}C]$. Micro-structural studies were carried out by XRD (D/MAX-1200, Rigaku Co.) and SEM (JSM-5400, Jeol Co.). Electrical properties were measured by CMT-SR3000 Measurement System.

  • PDF

대용량 태양광 발전용 멀티센트럴 시스템 (Multi-Central System for Large Scale PV Power Generation)

  • 박종형;고광수;김흥근;노의철;전태원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.427-432
    • /
    • 2012
  • This paper proposes efficient operation method of PV system consisted of multi-central which is suitable for large scale system. The multi-central system used switch at a DC-link and applied proposed algorithm can improve the efficiency and the reliability on the existing system. This algorithm, with advantage of Multi-Central system can minimize the effect of different characteristic of each PV array due to a shadow or damaged PV cell. Each system is analysed and maximum power point tracking control, DC-link voltage control and output current control is used commonly. The validity is verified after comparing of the existing system and proposed system by simulation.

  • PDF