• 제목/요약/키워드: Soil resistivity

검색결과 259건 처리시간 0.024초

Assessment and Correlation of Saline Soil Characteristics using Electrical Resistivity

  • Mustapha Maliki;Fatima Zohra Hadjadj;Nadia Laredj;Hanifi Missoum
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권3호
    • /
    • pp.205-214
    • /
    • 2023
  • Soil salinity is becoming one of the most devastating environmental hazards over the years. Soil investigation involves fast, low cost and non disturbing methods to measure soil characteristics for both construction projects as well as for agricultural use. The electrical resistivity of saline soils is greatly governed by salt concentration and the presence of moisture in soil matrix. Experimental results of this investigation highlight that there is a significant relationship between the electrical resistivity of soil samples mixed with chloride solutions (NaCl, KCl, and MgCl2) at various concentrations, and soil physical properties. Correlations represented by quadratic functions were obtained between electrical resistivity and soil characteristics, namely, water content, degree of saturation and salt concentration. This research reveals that the obtained correlations between electrical resistivity, salt concentration, water content and degree of saturation are effective for predicting the characteristics of salt affected soils in practice, which constitute a governing element in the assessment of saline lands sustaining infrastructure.

오염토양의 전기 비저항치 변화 연구 (Electrical Resistivity Variations of Contaminated Soils)

  • 윤길림;이용길
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 창립총회 및 춘계학술발표회
    • /
    • pp.84-89
    • /
    • 2000
  • Parametric studies based on laboratory pilot tests were performed to investigate the relationships between electrical resistivity and contaminated soil properties. Three kinds of sandy soils sampled and leachates from a industrial waste landfill were mixed to model the contaminated soils. Electrical resistivity of soils were measured by using a simulated resistivity cone penetrometer probe. In the experiments, the electrical resistivity were observed with changing the water content, void ratio, unit weight, degree of saturation, and concentration of the leachate. The test results show that the electrical resistivity of soils depends largely on the water content and the electrical property of pore water rather than unit weight and types of soils.

  • PDF

체적함수비 및 주파수에 따른 풍화토의 전기비저항 특성 (Characteristic of electrical resistivity against volumetric water content and frequency in weathered soil)

  • 손영환;봉태호;장병욱
    • 한국농공학회논문집
    • /
    • 제50권5호
    • /
    • pp.63-72
    • /
    • 2008
  • This study was conducted to define a characteristics of Electrical Resistivity of weathered soil against volumetric water content and frequency. It is essential to analyze and understand a characteristics of the Electrical Resistivity for evaluation of soil as subsurface contaminant detection. Before the test, an effect of pore water and ion were checked using four liquids(distilled water, tap water, potassium chloride 1.8mM, and 3.7mM). As a result, the correlation between the volumetric water content and the Electrical Resistivity was estimated. The Electrical Resistivity decreases with increasing frequency and water content. Also, Electrical Resistivity could be described by an exponential function of volumetric water content with the constants.

변전소 접지설계를 위한 대지저항율 측정시 전극간 최대간격이 접지해석에 미치는 영향 (Effects of Maximum Probe Spacing of Soil Resistivity Survery on Substation Grounding Analysis)

  • 정길조;곽희로;최종기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권8호
    • /
    • pp.382-386
    • /
    • 2001
  • Presently, typical maximum probe spacing of soil resistivity survey(Wenners 4 pin method) is 20 m in case of 154 K substation grounding design of KEPCO. This paper examined the effects of maximum probe spacing of wenner method on the equivalent soil modeling and the accuracy of grounding resistance measurement by comparing the calculated FOP(Fall-of-Potential) curves of various soil models with the measured one at 154kV H substation. The comparison results showed that the inaccurate estimation of deep soil resistivity, which is caused from the short probe spacing of soil resistivity survey, can produce large errors on measurement of grounding resistance. In this paper a quantitative analysis of FOP at H substation has been presented.

  • PDF

저압 지중케이블의 토양 열저항률 적용에 관한 연구 (A Study on the Apply to Soil Thermal Resistivity of Low-Voltage Underground Power Cables)

  • 이주철;김기현;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.65-70
    • /
    • 2012
  • The current-carrying capacities in IEC standards for underground refers to a soil thermal resistivity of 2.5[$K{\cdot}m/W$] where no measured data are available. But this value is considered too conservative and may not justifiable economically as to need precaution in using the value. In this paper, the standard practices on the application of soil thermal resistivity of some countries(UK, USA etc) are surveyed and proposed a reasonable representative value 1.0[$K{\cdot}m/W$] of soil thermal resistivity considering the domestic soil thermal properties with regard to the application of IEC standard.

토양의 저항률 및 비유전율의 주파수의존성을 고려한 접지봉의 접지임피던스의 해석 (Analysis of the Grounding Impedance of a Ground Rod Considering the Frequency-Dependent Resistivity and Relative Permittivity of Soil)

  • 안창환;최종혁;이복희
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.54-60
    • /
    • 2012
  • When the transient current with high frequency components such as lightning surges are injected the grounding electrodes, the performance of grounding electrodes should be evaluated as grounding impedance. It is restricted to analyze the grounding impedance by measurement approach since the grounding impedance is very different with the shape and size of grounding electrodes, resistivity and relative permittivity of soil and the frequency component of the injected current. So a variety of simulation approaches have been developed. Typically, the soil resistivity measured with low frequency and relative permittivity between 1 and 80 are used for simulation of the grounding impedance. However, the resistivity and relative permittivity of soil are changed with frequency of injected current. In this paper, the frequency-dependent resistivity and relative permittivity of soil are measured and these parameters are reflected in the simulation of the grounding impedance of a ground rod. The simulated results are compared with the measured results. As a result, the simulated results with frequency-dependent soil parameters show capacitive aspect like measured results in the frequency of lower than 100[kHz] and they are more consistent with the measured results in wide frequency range.

Use of Two Dimensional Electrical Resistivity Tomography to Identify Soil Water Dynamics and the Effective Plant Root Zone

  • Yoon, Sung-Won;Zhang, Yong-Seon;Han, Kyung-Hwa;Jo, Hee-Rae;Ha, Sang-Keun;Park, Sam-Kyeu;Sonn, Yeon-Kyu
    • 한국토양비료학회지
    • /
    • 제45권3호
    • /
    • pp.353-359
    • /
    • 2012
  • The identification of effective root zone would clarify dynamics of plant available water and soil water balance. Using the relationship between soil properties and electrical resistivity (ER) the purpose of this research is to identify soil zone affected by a plant root activity using electrical resistivity tomography (ERT) technique. Four plastic containers were prepared for two different soil textures (clay and sandy loam) and one container for each texture was selected for planting four corn seedlings (Zea mays L.) and the others were prepared for the blank. For ERT monitoring, we prepared 0.8 m plastic sticks with 17 electrodes installed with 5 cm space. The Ministing (AGI Inc., Texas) instrument for electrical resistivity measurement and semi-auto converter of electrode arrangement were set up for dipole-dipole array. During 2 months of the corns growing, ERT monitoring was made 3 to 4 days after the irrigation practice. Despite of the same amount water supplied into soils, two textures showed very different apparent resistivity values due to different clay content. The apparent electrical resistivity is consistently lower in clay loam comparing to sandy loam soil implying that plant root does not significantly alter the overall trend of resistivity. When plant root system, however, is active both soils with plants showed 2-7 times higher electrical resistivity and higher coefficient variation than soils without plant, implying the effect of root system on the resistivity, in which may caused by. This result suggests plant root activities regulating the soil water dynamics mainly control the variation of electrical resistivity over soil textural difference. Therefore the identification of water uptake zone would highly be correlated to plant root activities, thus ERT will be feasible approach to identify spatial characteristics of a plant root activity.

과천지역의 상세 토양비저항도(1/5000) 작성 (Development of Detailed Soil Resistivity Map(1/5000) in Kwachon)

  • 이현구;김대경;배정효;하태현;정성환;최상봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.315-317
    • /
    • 1999
  • Soil resistivity has a relation with the corrosion of underground buried structures as a water pipeline, gas pipeline and power cable casing. And it's a main factor in the cathodic protection and earth design. This paper presents soil resistivity maps each depth through measuring the soil resistivity in Kwachon, Kyonggi province. Also examines the soil resistivity characteristics on a change of temperature, moisture content and ion content in the laboratory.

  • PDF

대지저항률에 따른 매설지선의 접지임피던스의 주파수의존성 (Frequency-Dependent Grounding Impedances of Counterpoises Associated with Soil Resistivity)

  • 김태기;최영철;최종혁;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권5호
    • /
    • pp.114-121
    • /
    • 2010
  • 본 논문에서는 대지저항률과 매설지선의 길이 그리고 접지전류의 인가점에 따른 매설지선 접지임피던스의 주파수 의존성에 대하여 살펴보았다. 단일 구조와 2층 구조의 대지에 설치된 매설지선의 접지임피던스를 1[kHz]에서 10[MHz]의 주파수 범위에서 측정하고 분석하였다. 그 결과, 접지임피던스의 주파수 의존성은 대지저항률에 크게 영향을 받는 것으로 나타났으며, 그리고 높은 대지저항률의 대지에 설치된 매설지선의 접지임피던스는 수십 [kHz] 이하의 주파수에서 용량성 특성을 나타내었다. 높은 대지저항률을 갖는 대지에 설치된 매설지선의 끝단에 접지전류를 인가한 경우 접지임피던스는 높은 주파수 영역에서 증가하였다.

역전과 알고리즘(BP)을 이용한 대지저항률 추청 방법에 관한 연구 (A Study on Methodology of Soil Resistivity Estimation Using the BP)

  • 류보혁;위원석;김정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권2호
    • /
    • pp.76-82
    • /
    • 2002
  • This paper presents the method of sail-resistivity estimation using the backpropagation(BP) neural network. Existing estimation programs are expensive, and their estimation methods need complex techniques and take much time. Also, those programs have not become well spreaded in Korea yet. Soil resistivity estimation method using BP algorithm has studied for the reason mentioned above. This paper suggests the method which differs from expensive program or graphic technology requiring many input stages, complicated calculation and professional knowledge. The equivalent earth resistivity can be presented immediately after inputting apparent resistivity through the personal computer with a simplified Program without many Processing stages. This program has the advantages of reasonable accuracy, rapid processing time and confident of anti users.