• Title/Summary/Keyword: Soil hydraulic properties

Search Result 208, Processing Time 0.029 seconds

Physicochemical Properties of Root Zone Soil Based on Sand Blending with Coconut Coir and Peat Moss (코코넛 코이어와 피트모스 혼합 모래 토양의 물리·화학적 특성)

  • Kim, Young-Sun;Bae, Eun-Ji;Choi, Mun-Jin;Kim, Tae-Wooung;Lee, Geung-Joo
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.2
    • /
    • pp.101-107
    • /
    • 2022
  • BACKGROUND: Soil amendment was necessary applied for the sand that had been used to root zone of green ground in golf course because of its low water retention power and cation exchangeable capacity. This study was conducted to evaluate the effect of the mixed ratio of peat moss and coconut coir as soil amendment materials on the soil physicochemical properties applied to rootzone based on sand. METHODS AND RESULTS: The soil amendments were blended at 0, 3, 5, 7 and 10% by soil volume. The pH in the peat moss treatment was lower than that of control (0% soil amendment), and pH and electrical conductivity (EC) in the coconut coir were higher. The blending ratio of peat moss was negatively correlated with pH of rootzone soil (p<0.01), and that of coconut coir positively with EC (p<0.01). As compared with control, capillary porosity, the physical factors such as air-filled porosity, total porosity, and hydraulic conductivity of rootzone soil were increased by applying peat moss and coconut coir. For correlation coefficients between percentage of soil amendments and soil physical factors, peat moss and coconut coir were positively correlated with porosity and hydraulic conductivity (p<0.01). CONCLUSION(S): These results indicated that the application of peat moss and coconut coir affected on the change of physicochemical properties of rootzone soil, and improved soil porosity and hydraulic conductivity.

Decision of Available Soil Depth Based on Physical and Hydraulic Properties of Soils for Landscape Vegetation in Incheon International Airport

  • Jung, Yeong-Sang;Lee, Hyun-Il;Jung, Mun-Ho;Lee, Jeong-Ho;Kim, Jeong-Tae;Yang, Jae E
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.48 no.5
    • /
    • pp.522-527
    • /
    • 2015
  • Decision of available soil depth based on soil physical and hydraulic properties for the $3^{rd}$ Landscape Vegetation Project in the Incheon International Airport was attempted. The soil samples were collected from the 8 sites at different depths, 0-20 and 20-60cm, for the three project fields, A, B, and C area. Physical and chemical properties including particle size distribution, organic matter content and electrical conductivity were analyzed. Hydrological properties including bulk density and water holding capacity at different water potential, -6 kPa, -10 kPa, -33 kPa, and -1500 kPa were calculated by SPAW model of Saxton and Rawls (2006), and air entry value was calculated by Campbell model (1985). Based on physical and hydrological limitation, feasibility and design criteria of soil depth for vegetation and landfill were recommended. Since the soil salinity of the soil in area A area was $19.18dS\;m^{-1}$ in top soil and $22.27dS\;m^{-1}$ in deep soil, respectively, landscape vegetation without amendment would not be possible on this area. Available soil depth required for vegetation was 2.51 m that would secure root zone water holding capacity, capillary fringe, and porosity. Available soil depth required for landscape vegetation of the B area soil was 1.51 m including capillary fringe 0.14 m and available depth for 10% porosity 1.35 m. The soils in this area were feasible for landscape vegetation. The soil in area C was feasible for bottom fill purpose only due to low water holding capacity.

Study on Engineering Properties after Reclamation in Silty Sand Soil Layers of Western Ocean (서해안 지역 실트샌드의 매립직후 공학적 특성에 관한 연구)

  • Yang, Tae-Seon;Shim, Min-Bo;Yang, Tae-Gyu;Kim, Joo-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1054-1059
    • /
    • 2006
  • For reclamaing fill materials, hydraulic fill is needed in domestic parts of the reclamation sites every year. Engineering properties of soils after reclamation is calculated by laboratory. But before or after reclamation, reclamation quatities depend on the depth from the ground surface when hydraulic fill is dumped. In this paper, the engineering properties on the depth from ground surface are assumed by cone penetration test where fine grained soft soil is formed is proposed through several sites.

  • PDF

Estimation of saturated hydraulic conductivity of Korean weathered granite soils using a regression analysis

  • Yoon, Seok;Lee, Seung-Rae;Kim, Yun-Tae;Go, Gyu-Hyun
    • Geomechanics and Engineering
    • /
    • v.9 no.1
    • /
    • pp.101-113
    • /
    • 2015
  • Saturated soil hydraulic conductivity is a very important soil parameter in numerous practical engineering applications, especially rainfall infiltration and slope stability problems. This parameter is difficult to measure since it is very highly sensitive to various soil conditions. There have been many analytical and empirical formulas to predict saturated soil hydraulic conductivity based on experimental data. However, there have been few studies to investigate in-situ hydraulic conductivity of weathered granite soils, which constitute the majority of soil slopes in Korea. This paper introduces an estimation method to derive saturated hydraulic conductivity of Korean weathered granite soils using in-situ experimental data which were obtained from a variety of slope areas of South Korea. A robust regression analysis was performed using different physical soil properties and an empirical solution with an $R^2$ value of 0.9193 was suggested. Besides that this research validated the proposed model by conducting in-situ saturated soil hydraulic conductivity tests in two slope areas.

A Study on Soil-Bentonite Mixed Liner Properties for Waste Landfill (폐기물매립지의 흙-벤토나이트 혼합차수층 특성에 관한 연구)

  • 홍성길;한봉수;장연수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.597-604
    • /
    • 2001
  • In this study, the engineering characteristics of soil-bentonite mixed liner are investigated using the laboratory hydraulic conductivity and strength tests. The soil used for the liner is clayey silt in the site and the weathered granitic soil located near the waste landfill studied. Mixing ratio of the bentonite which satisfies the requirement of hydraulic conductivity is determined and the optimum mixing ratio of betonite is recommended for the landfill. After the mixed liner is constructed, the block samples of the constructed liner are obtained and the properties of interest satisfy the requirements of the liner of the landfill.

  • PDF

Green and Ampt Parameter Estimation Considering Temporal Variation of Physical Properties on Tilled Soil (경운토양의 물리적 특성변화를 고려한 Green And Ampt 매개변수의 추정)

  • 정하우;김성준
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.33 no.2
    • /
    • pp.120-129
    • /
    • 1991
  • This study refers to temporal variation of physical properties of tilled soil under natural rainfalls. Field measurements of porosity, average hydraulic conductivity and average capillary pressure head on a tilled soil were conducted by soil sampler and air-entry permeameter respectively at regular intervals after tillage. Temporal variation of these physical properties were analysed by cumulative rainfall energy since tillage. Field experiment was conducted on a sandy loam soil at Suwon durging April~July in 1989. The followings are a summary of this study results ; 1. Average porosity just after tillage was 0.548cm$^3$/cm$^3$. As cumulative rainfall energy were increased in 0.1070, 0.1755, 0.3849 J/cm$^2$, average porosity were decreased in 0.506, 0.4]95, 0.468m$^3$/cm$^3$ respectively. 2. Average hydraulic conductivity just after tillage was 45.42cm/hr. As cumulative rainfall energy were increased in 0.1755, 0.2466, 0.2978, 0.3849J/cm$^2$ average hydraulic conductivity were decreased in 15.34, 13.47, 9.58, 8.65cm/hr respectively. 3. As average porosity were decreased in 0.548, 0.506, 0.495, 0.468cm$^3$/cm$^3$ average capillary pressure head were increased in 6.1, 6.7, 6.9, 7.4cm respectively. 4. It was found that temporal variation of porosity, average hydraulic conductivity on a tilled soil might be expressed as a function of cumulative rainfall energy and average capillary pressure head might be expressed as a function of porosity. 5. The results of this study may be helpful to predict infiltration into a tilled soil more accurately by considering Temporal variation of physical properties of soil.

  • PDF

Reliability-Based Analysis of Slope Stability Due to Infiltration (침투에 대한 불포화 사면의 신뢰성 해석)

  • Cho, Sung-Eun;Lee, Jong-Wook;Kim, Ki-Young;Jeon, Je-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.649-654
    • /
    • 2005
  • Shallow slope failures in residual soil during periods of prolonged infiltration are common over the world. One of the key factors that dominate slope stability is hydrological response associated with infiltration. Hence, the soil-water profile during rainfall infiltration into unsaturated soil must me examined to evaluate slope stability. However, the hydraulic response of unsaturated soil is complicated by inherent uncertainties of the soil hydraulic properties. This study presents a methodology for assessing the effects of parameter uncertainty of hydraulic properties on the response of a analytical infiltration model using first-order reliability method. The unsaturated soil properties are considered as uncertain variables with means, standard deviations, and marginal probability distributions. Sensitivities of the probabilistic outcome to the basic uncertainties in the input random variables are provided through importance factors.

  • PDF

하천 바닥 퇴적층의 투수성시험과 누수계수 추정

  • Ha Gyu-Cheol;Go Dong-Chan
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.371-374
    • /
    • 2006
  • To quantify the hydraulic connection between river and aquifer, riverbed leakance values are required to be estimated. Silt, clay, and organic materials are often deposited in rivers resulting in the streambed having a lower hydraulic conductivity than the underlying alluvial aquifer The riverbed hydraulic conductivities are measured through vertical and oblique permeameter test. Anisotropic and heterogeneous properties of riverbed hydraulic conductivity were identified. Grain size analysis and flood wave response technique were checked along with the permeameter test for the riverbed hydraulic conductivity.

  • PDF

Relative Contribution rate on Soil Physico-chemical properties Related to Fruit Quality of 'Fuji' apple (사과 '후지' 품종의 품질에 미치는 토양이화학성의 상대적 기여도)

  • Kim, Seung-Heui;Choi, In-Myung;Han, Jeom-Wha;Cho, Jung-Gun;Son, In-Chang;Lim, Tae-Jun;Yun, Hea-Keun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.722-726
    • /
    • 2011
  • The management standard on soil conditions in 'Fuji' apple to produce high quality fruit were not yet made. Therefore, this study was carried out to investigate the optimum soil environmental conditions of ten contents on production of high quality fruit in 'Fuji' apple. The soil and fruit characteristics were analyzed at total 60 orchards in major apple producing areas such as Chungju, Moonkyeung, yeongju, andong, yeosan and yeongcheon (10 orchards an area). The soil environmental factors affected fruit weight was highest relative contribution in saturated hydraulic conductivity of 36.5%. The bulk density and soil pH were low as relative contribution. The fruit weight was influenced by soil physical properties more than soil chemical properties. The soil environmental factors affected sugar content were hydraulic conductivity of 28.3% and organic matter content of 18.2%. The cultivation layer depth and soil pH were low as relative contribution. The fruit coloring was highest relative contribution in saturated hydraulic conductivity 55.9%. while soil pH, cation and soil texture were low. Fruit coloring was high influenced over 70% by soil physical properties. Finally, relative contribution on fruit quality related with sugar content, fruit weight, and coloring were high influenced by saturated hydraulic conductivity of 21.% and organic matter content of 18.7% but bulk density and cultivation layer depth were low relative contribution. The fruit growth and saturated hydraulic conductivity in 'Fuji' apple were very closely related. Therefore, orchard soil management to produce high quality fruit was very importance drainage management and organic matter application. We concluded that scientific soil management is possible by qualifiable of soil management factors.

Change of Soil Physicochemical Properties by Mixed Ratio of 4 Types of Soil Amendments Used in Golf Course (골프장에 사용되는 4가지 토양개량제들의 혼합비율에 따른 토양이화학성의 변화)

  • Kim, Young-Sun;Ham, Suon-Kyu;Lim, Hye-Jung
    • Asian Journal of Turfgrass Science
    • /
    • v.24 no.2
    • /
    • pp.205-210
    • /
    • 2010
  • This study was conducted to investigate the effect of the mixed ratio of the soil amendments, peat, humate, peatmoss and zeolite, on the soil physicochemical properties. The mixed ratios of soil amendments were 0%, 3%, 5%, 7% and 10% (v/v) incorporated with sand which met to the USGA (United State of Golf Association) recommendation. It was measured pH, EC and CEC as a chemical properties. Porosity, capillary porosity, air-filled porosity, bulk density and hydraulic conductivity were also measured to analyze the changes of physical properties. Chemical properties were significantly different by mixture ratios of peat, humate, peatmoss and zeolite. When the results were applied to the USGA standard of the soil physical properties, the optimum mixture ratios of peat, humate and peatmoss were 5%, 3% and 7%, respectively. Air-filled porosity was factor involved in soil physical properties by blending with soil amendments and it was affected on volume of porosity and hydraulic conductivity. To analyze the corelation of mixture ratio versus to physical characters, the ratio of peat and peatmoss was significantly related to capillary porosity and hydraulic conductivity (P<0.05), that of humate hydraulic conductivity (P<0.01), and that of zeolite air-filled porosity and volume of porosity (P<0.05). These results could be used as a basic data for construction USGA sand green.