• Title/Summary/Keyword: Soft Surface

Search Result 975, Processing Time 0.034 seconds

TiO2 Nanotubes Fabricated by Atomic Layer Deposition for Solar Cells

  • Jung, Mi-Hee;Kang, Man-Gu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.161-161
    • /
    • 2011
  • Titanium (IV) dioxide (TiO2) is one of the most attractive d-block transition metal functional oxides. Many applications of TiO2 such as dye-sensitized solar cells and photocatalyst have been widely investigated. To utilize solar energy efficiently, TiO2 should be well-aligned with a high surface area and promote the charge separation as well as electron transport. Herein, the TiO2 nanotubes were successfully fabricated by a template-directed method. The electrospun PEO(Polyethylene oxide, Molecular weight, 400k)fibers were used as a soft template for coating with titanium dioxide using an atomic layer deposition (ALD) technique. The deposition was conducted onto a template at 50$^{\circ}C$ by using titaniumisopropoxide [Ti(OCH(CH3)2)4; TTIP] as precursors of TiO2. While the as-deposited TiO2 layers onto PEO fibers were completely amorphous with atomic layer deposition, the TiO2 layers after calcination at 500$^{\circ}C$ for 1 h were properly converted into polycrystalline nanostructured hallow TiO2 nanotube. The TiO2 nanotube with high surface area can be easily handled and reclaimed for use in future applications related to solar cell fabrications.

  • PDF

The Flexible Characteristic of Reversible and Robust Nanohair Fastener

  • Park, Seung-Ho;Yoon, Young-Seok;Lee, Dong-Woo;Lee, Dong-Ik;You, Kyoung-Hwan;Pang, Chang-Hyun;Suh, Kahp-Yang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.432-432
    • /
    • 2011
  • Dry adhesion caused by Nanoscale contact comes up to important scientific issue. Herein, we introduce bendable nanohairy locking fastener system with high shear strength and mechanically flexible backing. The polymeric patches like velcro are composed of an array of straight nanohairs with 100 nm diameter and $1{\mu}m$ height. To fabricate high aspect vertical nanohairs, we used UV molding method with appropriately flexible and rigid polyurethane acrylate material on PET substrate. Two identical nanohairy patches are easily merged and locked each other induced by van der Waals force. Because nanohairs can be arrayed with high density ${\sim}4{\times}10^8/cm^2$, we can obtain high shear adhesion force on flat surface (~22 N/$cm^2$). Furthermore, we can obtian nanohairy locking system with maximum shear adhesion ~48 N/$cm^2$ of curved surface due to flexibility of PET substrate. We confirm the tendency that shear adhesion force increases, as radius of curvature increases.

  • PDF

Effect of the Surface Oxidation on the Electromagnetic Wave Absorption Behavior of a Fe-based Nanocrystalline Alloy (Fe계 나노결정립 분말의 표면 산화에 따른 전자파 흡수특성)

  • Koo, S.K.;Woo, S.J.;Moon, B.G.;Song, Y.S.;Park, W.W.;Sohn, K.Y.
    • Journal of Powder Materials
    • /
    • v.14 no.5
    • /
    • pp.303-308
    • /
    • 2007
  • The oxidation of $Fe_{73}Si_{16}B_7Nb_3Cu_1$ nanocrystalline powder has been conducted to investigate its influence on the electromagnetic wave absorption characteristics of the soft magnetic material. Oxidation occurred primarily on the surface of nanocrystals. Oxidation reduced the real part of complex permeability due to the reduction of the relative volume of the powder, which otherwise contributes to the permeability. Oxidation reduced the absorption efficiency of the sheet at frequencies over 1GHz, indicating that the relative contribution of skin depth increments to the absorption was not significant. The pulverization and milling process lowered the optimum crystallization temperature of the material by $40{\sim}50^{\circ}C$ because of the internal energy accumulated during the fragmentation and powder thinning processes.

Mechanical and Surface Properties for Akaline Hydrolyzed Polyester Fabrics (알칼리 감량가공 된 폴리에스테르 직물의 역학적 특성과 표면특성에 관한 연구)

  • Kim, Kyung-Ae
    • Journal of the Korean Home Economics Association
    • /
    • v.36 no.8
    • /
    • pp.51-61
    • /
    • 1998
  • This paper discussed the assessment of hand of polyester fabrics changed by alkaline hydrolysis. This study analyzed the relations between the change of mechanical property and the hand value according to the weight loss of polyester fabrics. The results are as follows; Objective hand by KES-FB system, revealed that for tensile properties, as the weight loss increased, WT, RT increased and LT decreased. For bending properties, as the weight loss increased, B and 2HB showed smaller values. For shear properties, as the weight loss increased, G, 2HG and 2HG5 decreased. For surface properties, as the weight loss increased, MIU increased, but MMD and SMD did not show any trend. For compression properties, LC, WC and RC did not show significant differences according to the degree of weight loss. In case of hand value, Koshi(stiffness), Hari(anti-drape stiffness), Kisimi(scrooping feeling) and Shinayakasa(flexibility with soft feeling) showed a meaningful results depending on the degree of weight loss. However, Shari(crispness) and Fukurami(fullness and softness) did not show meaningful result. Koshi, Hari and Shinayakasa are high correlation with tensile property, bendibg property shear properties, thickness and weight. Kisimi is high correlation with tensile property, bending property, thickness and weight. Shari, Fukurami and THV did not show any meaningful difference whth any mechanical properties.

  • PDF

TOPICAL APPLICATION OF TETRACYCLINE GEL IN SCALING AND ROOT PLANING (치석제거 및 치근활택술 시에 테트라싸이클린 젤의 국소적 도포)

  • Han, Soo-Boo;Lee, Jae-Il;Heo, Jeong-Mi;Chang, Mee-Kyung;Shim, Chang-Koo;Lee, Chul-Woo
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.647-658
    • /
    • 1993
  • The purpose of this study is to examine the influence of 5% tetracycline(Tc) gel on healing of gingival tissue and change of diseased root surface when used with nonsurgical procedure. 7 patients with advanced periodontitis were received thorough scaling and root planning, followed by saline irrigation on 10 randomly selected control teeth and Tc gel application for 5 minutes with specifically designed plastic instrument of 10 test teeth in contralateral side. At 0, 1, 7, 14, and 21 days after treatment, biopsy and extraction were carried out. At day 7, Tc group showed decreased inflammation and delayed proliferation of pocket epithelium in comparison with control group which was continued for all experimental days. Scanning electron microscopic finding revealed demineralized and cleaned root surface with exposed dentinal tubules in Tc gel group. In the present study, clinically successful result is expected with combined use of nonsurgical periodontal therapy and intrapocket application of Tc gel.

  • PDF

Field Emission Enhancement by Electric Field Activation in Screen-printed Carbon Nanotube Film

  • Lee, Hyeon-Jae;Lee, Yang-Doo;Cho, Woo-Sung;Kim, Jai-Kyeong;Hwang, Sung-Woo;Ju, Byeong-Kwon
    • Journal of Information Display
    • /
    • v.6 no.4
    • /
    • pp.45-48
    • /
    • 2005
  • By applying a critical field treatment instead of the conventional surface treatments such as soft rubber roller, ion beam irradiation, adhesive taping, and laser irradiation, electron emission properties of screen-printed carbon nanotubes (CNTs) were enhanced and investigated based on the emission current-voltage characteristics through scanning electron microscopy. After nanotube emitters were activated at the applied electric-field of 2.5 V/um, the electron emission current density with good uniform emission sites reached the value of 2.13 mA/$cm^2$ , which is 400 times higher than that of the untreated sample, and the turn-on voltage decreased markedly from 700 to 460 V. In addition, enhancement of the alignment of CNTs to the vertical direction was observed.

Optimization of Electrolytes on Cn ECMP Process (Cu ECMP 공정에 사용디는 전해액의 최적화)

  • Kwon, Tae-Young;Kim, In-Kwon;Cho, Byung-Gwun;Park, Jin-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.78-78
    • /
    • 2007
  • In semiconductor devices, Cu has been used for the formation of multilevel metal interconnects by the damascene technique. Also lower dielectric constant materials is needed for the below 65 nm technology node. However, the low-k materials has porous structure and they can be easily damaged by high down pressure during conventional CMP. Also, Cu surface are vulnerable to have surface scratches by abrasive particles in CMP slurry. In order to overcome these technical difficulties in CMP, electro-chemical mechanical planarization (ECMP) has been introduced. ECMP uses abrasive free electrolyte, soft pad and low down-force. Especially, electrolyte is an important process factor in ECMP. The purpose of this study was to characterize KOH and $KNO_3$ based electrolytes on electro-chemical mechanical. planarization. Also, the effect of additives such as an organic acid and oxidizer on ECMP behavior was investigated. The removal rate and static etch rate were measured to evaluate the effect of electro chemical reaction.

  • PDF

Microstructure and Mgnetic Properties of Electrodeposited Nanocrystalline Low-Nickel Permalloy (전착법으로 제조한 나노결정질 저Ni 퍼멀로이의 미세 조직과 자기적 특성)

  • 허영두;이흥렬;황태진;임태홍
    • Journal of Surface Science and Engineering
    • /
    • v.36 no.6
    • /
    • pp.455-460
    • /
    • 2003
  • Microstructural and magnetic properties of nanocrystalline Fe-46 wt%Ni and Fe-36 wt%Ni alloys were investigated. Alloys were prepared by the electrodeposition process. The electrolytes were iron sulfate/nickel chloride-based and iron chloride/nickel sulfamate-based solutions. Fe-46 wt%Ni alloy was FCC structure with grain size of 10 nm, but FCC and BCC phases were found in Fe-36 wt%Ni alloy and its grain size was smaller. Effective permeability of Fe-36 wt%Ni alloy was higher than that of Fe-46 wt%Ni alloy in the high frequency range because of large electrical resistivity and small eddy current loss resulted from grain size decrease. Up to $300^{\circ}C$ of annealing temperature, grain growth of Fe-Ni alloys slowly occured. Conversely, annealing above $450^{\circ}C$ led to a drastic grain growth. In that case, effective permeability was decreased at the temperature lower than $300^{\circ}C$ but at $300^{\circ}C$ or higher effective permeability was increased. At the high frequency of 1 MHz, electrodeposited Fe-Ni alloys had higher effective permeability with an decrease in the grain size.

The Microstructure And The Mechanical Properties Of(Ti$_{1-x}$AI$_{x}$)N Coatings Deposited By Plasma Enhanced Chemical Vapor Deposition(PECVD) (플라즈마 화학증착법에 의해 제조된 (Ti$_{1-x}$AI$_{x}$)N 박막의 미세조직 및 기계적 특성에 관한 연구)

  • Lee, D.K.;Lee, S.H.;Han, Y.H.;Lee, J.J.
    • Journal of Surface Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.97-104
    • /
    • 2001
  • ($Ti_{ 1-x}$$Al_{ x}$)N has been deposited on high speed steel (HSS) substrate using PECVD from the gas mixture of $TiC1_4$, $AlC1_4$, $NH_3$, $H_2$, and Ar. The correlation between the microstructure and the mechanical properties was investigated. ($Ti_{1-x}$$Al_{ x}$)N showed single phase NaCl-structure up to X=0.87, while a mixed phase of NaCl Type (Ti, Al) N and wurtzite structure AlN was observed for 0.87$Ti_{1-x}$ $Al_{x}$ )N became by degrees as increasing X, which made the hardness of the coating higher by Al addition. When the coating was composed of a mixed phase, however, the hardness decreased abruptly due to the effect of soft AlN phase. The wear volume of the coatings could be obtained as the concentration of the coating was varied, and the relation between the wear volume and hardness or the adhesion strength was discussed.

  • PDF

THE MORPHOLOGICAL OBSERVATION OF HUMAN GINGIVAL FIBROBLASTS ATTACHMENT AND SPREADING ON THE MECHANICAL TREATED TITANIUM PLASMA SPRAYED IMPLANT SURFACE (기계적 표면 처리된 TITANIUM PLASMA SPRAYED IMPLANT에 대한 치은섬유아세포전개양상의 형태학적 관찰)

  • Whang, Yun-Hi;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.741-755
    • /
    • 1995
  • Currently titanium is the material of choice for implants because of its biological acceptance. This high degree of biocompatibility is thought to result, in part, from the protective and stable oxide layer that presumably aids in the bonding of the extracellular matrix at the implant-tissue interface. Endosseous dental implants are interfaced with bone, connective tissue, and epithelium when implanted into the jaw bone. The soft tissue interface including connective tissue and epithelium is one of the most critical factors in the determination of implant maintenance and prognosis. For maintenance of failing or failed implants, it is essential to treat the implant fixture surface to remove bacterial endotoxins and make a surface tolerated by surrounding soft and hard tissues. In this study, the effect of mechanical treatment on titanium plasma sprayed implant on adhesiveness and proliferation of human gingival fibroblasts and changed surface characteristics were studied. titanium plasma sprayed discs manufactured by Friedrichsfeld company were treated with loaw speed stone bur, a rubber point and a jetpolisher. Its surface components were analyzed with Energy dispersive X-ray spectroscopy to evaluate whether the surface characteristics were altered or not. To observe the spreading pattern of the human gingival fibroblasts which attached to the all specimens author used the scanning electron microscope. The results were as follows : Pure titanium and plasma sprayed titanium, stone polished titanium showed titanium peak and small amout of aluminum, so there was no alteration on surface characteristics. Under the scanning electron microscopic examination in the initial attachment of human gingival fibroblast, there was a slight enhancement in pure titanium, stone polished titanium than plasma sprayed titanium. After 6 hours, the pure titanium and stone polished titanium showed human gingival fibroblasts were elongated and connected with numerous processes. Human gingival fibroblasts were more intimately attached on the pure titanium discs than on the other discs. The human gingival fibroblasts attached on the plasma sprayed titanium by thin and elongated processes. After 24 hours, the human gingival fibroblasts connected with each other via numerous processes and compeletly covered the pure titanium and stone polshed titanium discs. Human gingival fibroblasts had multiple point contacts with more long and thin lamellopodia and showed a little bare surface on plasma sprayed titanium discs.

  • PDF