• 제목/요약/키워드: Smoke removing characteristics

검색결과 6건 처리시간 0.019초

실공간에서 공기정화시스템을 이용한 실내 오염 입자 제거 특성에 관한 연구 (A Study on the Removal Characteristics of Indoor Air Pollutants using the Air Cleaning System)

  • 구정환;김성찬;김장우;이주용;이재근;강태욱;이감규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.532-537
    • /
    • 2000
  • The purpose of this study is to determine the performance of a commercial air cleaner in removing tobacco smoke indoors. Following injection of tobacco smoke in a room, decay rates for particle concentrations were obtained far mass concentration at each point. The size distribution of the tobacco smoke particles was approximately $1.266{\mu}m$ in mass median diameter with a geometric standard deviation of 1.313. The air cleaner consisted of an electrostatic filtration unit and a fan operated at a flow rate of 5.98 CMM. The collection efficiency for $>1\;{\mu}m$ was more than 99%. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 30% of initial values within 30 minutes and with air cleaner operation, decreased to 90% of initial values in the test chamber, volume $51.27\;m^3$. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 10% of initial values within 30 minutes and with air cleaner operation, decreased to 30-70% of initial values in the test chamber, volume $149.2\;m^3$.

  • PDF

A Study on the Smoke Removal Characteristics of the ESP Adopting Resonant dc-dc Converter

  • Kim, Su-Weon;Park, Jong-Woong;Joung, Jong-Han;Chung, Hyun-Ju;Choi, Jin-Young;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권5호
    • /
    • pp.193-200
    • /
    • 2004
  • In this study, we propose a small high voltage power supply, which uses a half-bridge ZCS resonant and Cockroft-Walton circuit as its ESP (Electrostatic Precipitator). This power supply transfers energy from the ZCS resonant inverter to the step-up transformer. The transformer secondary is then applied to the Cockroft-Walton circuit for generating high voltage as a discharging source of electrodes. It is highly efficient because its amount of switching losses are reduced by virtue of the current resonant half-bridge inverter, and also due to the small size, low parasitic capacitance in the transformer stage owing to the low number of winding turns of the step up transformer secondary combined with the Cockroft-Walton circuit. Using this power supply, experiments have been carried out as a function of the switching frequency and duty ratio in order to investigate the smoke removal characteristics. From these results, the best operational condition is obtained at the switching frequency of 9 kHz and the duty ratio of 50% in this ESP.

이온교환체에 의한 담배 주류연 중 카보닐 화합물의 선택적 흡착 특성 및 흡착 메카니즘 구명 (Investigation of Adsorption Mechanism and Selective Adsorption of Carbonyl Compounds of Mainstream Tobacco Smoke by Ion Exchangers)

  • 이존태;김효근;지상운;황건중;이문수;박진원
    • 한국연초학회지
    • /
    • 제26권2호
    • /
    • pp.159-167
    • /
    • 2004
  • This work has been conducted to select appropriate filter materials for removing carbonyl compounds in mainstream tobacco smoke. To investigate of the usability of this filter materials, two types of bead ion exchangers were synthesized and their adsorption characteristics for carbonyl compounds were investigated. Sulfonic acid group-containing cation exchanger and ammonium group-containing anion exchanger were synthesized by the suspension polymerization of glycidylmethacrylate(GMA) and divinylbenzene(DVB) followed by the subsequent functionalization, respectively. The removal efficiency of carbonyl compounds by these two ion exchangers increased in the presence of moisture. However, the amount of carbonyl compounds adsorbed on the anion exchanger was larger than that on the cation exchanger under two levels of water contents tested. This phenomenon seems to arise from the electron delocalization in carbonyl group of the anion exchangers. There was not any significant relationship between the amount of carbonyl compounds adsorbed on ion exchangers and the length of adsorption column. From the large ion exchange capacity and rapid ion exchange reaction rate of the anion exchanger, it is suggested that the anion exchanger may be a good filter material for removing carbonyl compounds in the mainstream tobacco smoke.

레이저 혼탁도 모니터링을 통한 공기청정 특성에 관한 연구 (A study on characteristic of the smoke removal of an air cleaner by monitoring of turbidity with laser)

  • 김수원;박종웅;정종한;정현주;이유수;전진안;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1698-1700
    • /
    • 2003
  • The electrostatic precipitator(ESP) is a device for removing particulate pollutants in the form of either a solid (dust or fumes) or a liquid (mist) from a gas using an electrostatic force, Electrostatic precipitation has been widely used for cleaning gas from almost all industrial processes with a medium to large gas volume(>2,000 $m^3/min$), including utility boilers, blast furnaces, and cement kilns. ESP is also in wide use for air cleaning in living environments (home, offices, hospitals, etc.) ESP has large advantages over other particulate control device : a low operating cost, a high collection performance, and ease of maintenance. The purpose of this study is to investigate the characteristics of the smoke removal of an air cleaner by adjusting variable frequency and monitoring of turbidity three results of this research are as follows ;the first is the best efficient switching frequency which is 60Hz, the second is the smoke removal time which is obtained to 9 seconds, third is that the best efficient firing angle is $90^{\circ}$ As a result, the switching trigger frequency and SCR gate firing angle is very important factor to predict the best collection efficiency.

  • PDF

DC 저온플라즈마를 이용한 디젤엔진 유해 배기가스 저감에 관한 실험적 연구 (The Experimental Study on the Removal of Diesel Engine Pollutant Emissions Using DC Non-Thermal-Plasma(NTP))

  • 채재우;황재원;정지용;한정희;황화자;김석
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.35-42
    • /
    • 2001
  • The diesel engine exhaust gas is know as one of the causes to produce photochemical smog, which causes damage on environmental. However, due to the high thermal efficiency and low carbon dioxide emission, the usage of a diesel engine is prevailed. In this study, the DC non-thermal plasma technology used to the particulate matter (PM) aftertreatment. The exhaust gas characteristics and energy density were investigated on the dynamometer test bed and chassis dynamometer with CVS-75 mode in a passenger diesel car. It was reported that the smoke removal efficiency has around the 70% in the dynamometer test with 80W energy consumption and the PM removal efficiency has the 68% in the real car test. The NOx also reduced the 20% according to electrode type respectively. Considering these results, plasma technology is one of the ways to simultaneously removing method the particulate matter (PM) and NOx.

  • PDF

섬유 텐터 대기오염물질의 선택적 제거를 위한 싸이클론 및 전기 집진 오일필터의 특성 (Characteristics of Cyclone and Electric Dust Collection Oil Filters for Selective Removal of Fiber Tenter Air Pollutants)

  • 정진호;류승한;권순덕;조윤현
    • 한국염색가공학회지
    • /
    • 제35권4호
    • /
    • pp.256-273
    • /
    • 2023
  • Among the dyeing industries, the tenter process is a process that improves the quality of fibers by drying and ironing (heat treatment) dyed fabrics, and drugs such as water repellents, antistatic agents, and fiber softeners are mainly used in these tenter processes. These drugs are vaporized in the process of treatment by high temperatures (180 ~ 230℃), and are observed in a complex form such as white smoke, oil mist, and fine dust, causing odor. To treat the complex exhaust gas at the rear end of the tenter facility, most companies operate by installing a wet scrubber and an adsorption tower alone or in parallel, but there are many problems. In particular, the insoluble oil mist at the rear end of the tenter has significantly low processing efficiency in the cleaning dust collection facility, and there is a problem in the facility by adsorption due to the occlusion phenomenon caused by the oil mist. In addition, the odor gas at the rear end of the tenter contains a lot of aldehydes, and in order to improve these various problems, a complex exhaust purification device using cyclone and electric support collector was developed. This study examined the applicability of economical and efficient technology by removing complex air pollution at the rear end of the tenter and applying improved technology than the existing technology.