A study on characteristic of the smoke removal of an air cleaner by monitoring of turbidity with laser

레이저 혼탁도 모니터링을 통한 공기청정 특성에 관한 연구

  • 김수원 (부산대학교 전기공학과) ;
  • 박종웅 (부산대학교 전기공학과) ;
  • 정종한 (부산대학교 전기공학과) ;
  • 정현주 (부산대학교 전기공학과) ;
  • 이유수 (부산대학교 전기공학과) ;
  • 전진안 (부산대학교 전기공학과) ;
  • 김희제 (부산대학교 전기공학과)
  • Published : 2003.07.21

Abstract

The electrostatic precipitator(ESP) is a device for removing particulate pollutants in the form of either a solid (dust or fumes) or a liquid (mist) from a gas using an electrostatic force, Electrostatic precipitation has been widely used for cleaning gas from almost all industrial processes with a medium to large gas volume(>2,000 $m^3/min$), including utility boilers, blast furnaces, and cement kilns. ESP is also in wide use for air cleaning in living environments (home, offices, hospitals, etc.) ESP has large advantages over other particulate control device : a low operating cost, a high collection performance, and ease of maintenance. The purpose of this study is to investigate the characteristics of the smoke removal of an air cleaner by adjusting variable frequency and monitoring of turbidity three results of this research are as follows ;the first is the best efficient switching frequency which is 60Hz, the second is the smoke removal time which is obtained to 9 seconds, third is that the best efficient firing angle is $90^{\circ}$ As a result, the switching trigger frequency and SCR gate firing angle is very important factor to predict the best collection efficiency.

Keywords