• Title/Summary/Keyword: Smoke protection

Search Result 183, Processing Time 0.035 seconds

An Experimental Study on the Fire Safety Design of Windows in Building (건축물 창호의 화재안전설계를 위한 실험적 연구)

  • Lee, Byeong-Heun;Jin, Seung-Hyun;Han, Ji-Woo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.10-11
    • /
    • 2018
  • In the building, the opening penetrates the wall and serves as a spreading channel for smoke and flame in case of fire. In Korea, more than 1,500 fire plume are generated annually, and the number has increased by about 30% over the past five years. Therefore, in the case of windows protecting the opening, fire protection performance is important to prevent the spread of fire. However, in Korea, the standard for window is not clear. In this study, fire tests (EN 13823) for windows were conducted in Korea, and then fire protection performance of windows was compared. As a result of the experiment, PVC windows showed a phenomenon that they could not withstand the temperature during the fire experiment, and AL windows showed a difference in the degree of cracking of the glass.

  • PDF

A Study on Assessment of Fire and Evacuation Safety in Environmental Energy Facilities (환경에너지시설의 화재 및 피난 안전성 평가에 관한 연구)

  • Jeon, Yong-Han;Han, Sang-Pil
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.39-44
    • /
    • 2019
  • In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.

IR 불꽃화재감지기 개발

  • Gwon, O-Seung;Lee, Bok-Yeong;Park, Sang-Tae
    • Fire Protection Technology
    • /
    • s.29
    • /
    • pp.39-45
    • /
    • 2000
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of a fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage such fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to active a heat detector. In this case the most effective criterion for automatic fire detection is the flame. In fire regulation of korea, the compulsory standard provided that a flame detector shall be installed a place of the attachment hight of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The result of the research and development are discriminated between a flame and other radiant emitters, developed PZT pyroelectric element is based on the use of photo-voltanic cell, developed IR band-pass filter that only allow a 4.3 radiation wavelength to reach the sensors and developed IR flame detector.

  • PDF

조사연구-콘칼로리메타를 이용한 화재시험에 대하여

  • Lee, Du-Hyeong
    • Fire Protection Technology
    • /
    • s.19
    • /
    • pp.22-28
    • /
    • 1995
  • The rate of heat release is probably the single most important measure of fire hazard. Several tech-niques were developed for the measurement of rate of heat release, but were not suitable for fire test-ing purpose. Recently the application of oxygen consumption principle made it possible to development of well-characterized heat release rate measurement apparatus, the furniture calorimeter for large-scale fire tests and the cone calorimeter for bench-scale fire tests. The cone calorimeter can be used to determine the ignitability as well as heat release rate and smoke development, mass loss rate, combustion gas production etc. from burning materials. Thus, test method using cone calorimeter, an internationally recognized and accepted for the evalua-tion of fire properties, is a very promising tool for combustion study on various kind of materials and products.

  • PDF

Design of Over Current Sequence Control Algorithm According to Lithium Battery Fuse Temperature Compensation (리튬 배터리 퓨즈 온도 보상에 따른 과전류 시퀀스 제어 알고리즘 설계)

  • Song, Jung-Yong;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.1
    • /
    • pp.58-63
    • /
    • 2019
  • Lithium-ion batteries used for IT, automobiles, and industrial energy-storage devices have battery management systems (BMS) to protect the battery from abnormal voltage, current, and temperature environments, as well as safety devices like, current interruption device (CID), fuse, and vent to obtain positive temperature coefficient (PTC). Nonetheless, there are harmful to human health and property and damage the brand image of the manufacturer because of smoke, fire, and explosion of lithium battery packs. In this paper, we propose a systematic protection algorithm combining battery temperature, over-current, and interconnection between protection elements to prevent copper deposition, internal short circuit, and separator shrinkage due to frequent and instantaneous over-current discharges. The parameters of the proposed algorithm are suggested to utilize the experimental data in consideration of battery pack operating conditions and malicious conditions.

A Study on the Analysis of Fire Risk for each Building Usage Based on the Reliability of Operation of Fire Protection System (소방설비 작동신뢰성 기반 건축용도별 화재리스크 분석에 관한 연구)

  • Jin, Seung-hyeon;Kim, Hye-Won;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.113-114
    • /
    • 2020
  • In the design and maintenance of buildings, identifying the degree of damage in the event of a fire is an important factor in fire prevention and fire safety design. In order to predict fire damage, safety measures should be established by predicting the nature of evacuation according to fire, smoke and in-house characteristics, and the effects of the operation of fire safety facilities should also be considered, but in Korea, the risk analysis due to the operation of fire safety facilities is insufficient. Accordingly, this study uses fire statistics and sprinkler inspection data to analyze the degree of fire damage caused by the operation of sprinkler facilities in a probabilistic manner.

  • PDF

A Study on the Smoke control Design parameter of Large Volume space by Fire Dynamic Simulation (화재 시뮬레이션(FDS)을 이용한 대형공간의 제연 설계인자에 관한 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.237-243
    • /
    • 2018
  • Performance-oriented design has been introduced in fire protection design, and various efforts have been made to minimize the damage caused by fire in the design stage. We conducted a study to provide information for reasonable design factors using a Fire Dynamic Simulation code provided by the NIST on boundary width and amount of supply. This paper shows that using a living-room air-supply system in a large space and dividing the space by a ventilation boundary are the two factors that are considered to have the greatest influence on the design of the living room ventilation. The results show that for performance-based design, the width of the ventilation boundary is designed to be the maximum limit in the initial design. It is judged that reasonable air volume determination should be made through various methods.

An Estimation of Concentration of Asian Dust (PM10) Using WRF-SMOKE-CMAQ (MADRID) During Springtime in the Korean Peninsula (WRF-SMOKE-CMAQ(MADRID)을 이용한 한반도 봄철 황사(PM10)의 농도 추정)

  • Moon, Yun-Seob;Lim, Yun-Kyu;Lee, Kang-Yeol
    • Journal of the Korean earth science society
    • /
    • v.32 no.3
    • /
    • pp.276-293
    • /
    • 2011
  • In this study a modeling system consisting of Weather Research and Forecasting (WRF), Sparse Matrix Operator Kernel Emissions (SMOKE), the Community Multiscale Air Quality (CMAQ) model, and the CMAQ-Model of Aerosol Dynamics, Reaction, Ionization, and Dissolution (MADRID) model has been applied to estimate enhancements of $PM_{10}$ during Asian dust events in Korea. In particular, 5 experimental formulas were applied to the WRF-SMOKE-CMAQ (MADRID) model to estimate Asian dust emissions from source locations for major Asian dust events in China and Mongolia: the US Environmental Protection Agency (EPA) model, the Goddard Global Ozone Chemistry Aerosol Radiation and Transport (GOCART) model, and the Dust Entrainment and Deposition (DEAD) model, as well as formulas by Park and In (2003), and Wang et al. (2000). According to the weather map, backward trajectory and satellite image analyses, Asian dust is generated by a strong downwind associated with the upper trough from a stagnation wave due to development of the upper jet stream, and transport of Asian dust to Korea shows up behind a surface front related to the cut-off low (known as comma type cloud) in satellite images. In the WRF-SMOKE-CMAQ modeling to estimate the PM10 concentration, Wang et al.'s experimental formula was depicted well in the temporal and spatial distribution of Asian dusts, and the GOCART model was low in mean bias errors and root mean square errors. Also, in the vertical profile analysis of Asian dusts using Wang et al's experimental formula, strong Asian dust with a concentration of more than $800\;{\mu}g/m^3$ for the period of March 31 to April 1, 2007 was transported under the boundary layer (about 1 km high), and weak Asian dust with a concentration of less than $400\;{\mu}g/m^3$ for the period of 16-17 March 2009 was transported above the boundary layer (about 1-3 km high). Furthermore, the difference between the CMAQ model and the CMAQ-MADRID model for the period of March 31 to April 1, 2007, in terms of PM10 concentration, was seen to be large in the East Asia area: the CMAQ-MADRID model showed the concentration to be about $25\;{\mu}g/m^3$ higher than the CMAQ model. In addition, the $PM_{10}$ concentration removed by the cloud liquid phase mechanism within the CMAQ-MADRID model was shown in the maximum $15\;{\mu}g/m^3$ in the Eastern Asia area.

A Study on the Development of a VR Game to Experience the Fire Evacuation and its Effect Analysis (화재 탈출 체험 VR 게임 개발과 효과 분석)

  • Kim, KyungSik;Park, YongHwan
    • Journal of Korea Game Society
    • /
    • v.20 no.2
    • /
    • pp.153-162
    • /
    • 2020
  • In this research, a VR game was developed to experience the fire evacuation from a fired building, intending calm and fast reaction in urgent fire situations. The user should move out through the fire door, stairs and corridors toward exit door using the VIVE controllers. When the user can't proceed the path because of fire flame or smoke, he/she should turn back to find another path. A building of Hoseo university was modeled and tests were carried out by students with polls focused on the usability and the effectiveness of this VR game. The result has been analyzed to show their responses.

Working Conditions and Health Status of Delivery Workers (배달종사자의 근로환경과 건강)

  • Lee, Bokim
    • Korean Journal of Occupational Health Nursing
    • /
    • v.28 no.3
    • /
    • pp.156-165
    • /
    • 2019
  • Purpose: The purpose of this study was to compare working condition and health status between parcel delivery workers (PDW) and food delivery workers (FDW) and to examine the factors influencing their health status. Methods: This was a secondary analysis of data collected from the fifth Korean Working Conditions Survey (KWCS). Based on existing literature, a set of variables was chosen from the KWCS. Results: The proportion of PDW who carryied/moved heavy loads and experienced high job stress and lack of rest time was significantly higher than that of FDW. However, more FDW than their counterparts worked atypical hours. The differences in fatigue and well-being between PDW and FDW were not statistically significant. The multiple logistic regression analysis revealed low temperature, tobacco smoke, standing for long periods, and job stress were significant predictors of fatigue or well-being of FDW. Among PDW, noise, tobacco smoke, sitting for long periods, quantitative demands, hiding emotions, support from colleagues, job stress, no recovery period, and night work were significant predictors of fatigue or well-being. Conclusion: The findings of this study may be useful in developing nursing interventions for disease protection health promotion of delivery workers.