Numerical Study on Air Egress Velocity of Ancillary Room Pressurization Systems in Apartment Fires (공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구)

  • Kim, Byeongjun;Yang, Ying;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.78-86
    • /
    • 2020
  • In this study, numerical simulations were performed on the air egress velocity of pressurization systems in an ancillary room when a fire occurred in an apartment house. The relationship between the air supply flow rate of a damper and air egress velocity at a fire door is predicted to be linear. Additionally, a minimum flow rate of the damper, which meets national fire safety standards for air egress velocity, i.e., 0.7 m/s can be estimated. Air egress velocity at the fire door is analyzed according to the supply air direction and installation height of the damper. When the damper has an upward supply air direction and is installed at a high level, the egress velocity at the top section of the fire door is larger, whereas the soot concentration at the ancillary room is lower than when the supply direction of the damper is downward. Therefore, it is found that increasing the air egress velocity at the top section of the fire door helps to efficiently prevent the inflow of smoke.

Effects of Sagan-tang and individual herbs on COPD Mice Model (만성폐쇄성폐질환 동물모델에 대한 射干湯 및 구성약물의 효과)

  • Han, Jong-Min;Yang, Won-Kyung;Kim, Seung-Hyeong;Park, Yang-Chun
    • Herbal Formula Science
    • /
    • v.23 no.2
    • /
    • pp.171-187
    • /
    • 2015
  • Objective This study aimed to evaluate the effects of Sagan-tang (SGT) on COPD mouse model. Methods The study was carried out by two ways (in vitro, in vivo). In vitro RAW264.7 cells (mouse macrophage) were used and analysed by flow cytometry, ELISA, Western blot. In vivo LPS and CSS challenged mice were used and its BALF had been analysed by cytospin image, FACS, ELISA, lung tissue by real-time PCR. Results In vitro, SGT maintained 80-100% rate of viablilty on 10 ~ 500 ㎍/㎖ concentration. In ELISA analysis with RAW264.7 cells, SGT significantly decreased NO over 30 ㎍/㎖. In flow cytometry, SGT 100 ㎍/㎖ dosage group displayed a tendency for decrease ROS. In Western blot analysis, SGT 100 ㎍/㎖ dosage group decreased NF-κB. In ELISA analysis, SGT significantly decreased TNF-α, IL-6 over 200 ㎍/㎖. In vivo SGT 200 ㎎/㎏ dosage group, application of SGT significantly decreased increase of neutrophils, TNF-α, IL-6 in BALF, muc5AC, TGF-β, TNF-α, expression of mRNA in lung tissue and histological lung injury. Conclusion This Study suggests usability of SGT for COPD patients by controlling lung tissue injury.

Vortex pairing in an axisymmetric jet using fundamental and subharmonic forcing (기본교란 및 분수조화교란을 이용한 원형제트에서의 보텍스병합)

  • Jo, Seong-Gwon;Yu, Jeong-Yeol;Choe, Hae-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1350-1362
    • /
    • 1997
  • An experimental study has been performed on vortex pairing under fundamental and subharmonic forcing with controlled initial phase differences through hot-wire measurements and a multi-smoke wire flow visualization. For the range of St$_{D}$ < 0.6, vortex pairing was controlled by means of fundamental and subharmonic forcing with varying initial phase differences. Much larger mixing rate was achieved by two-frequency forcing with a proper phase difference than one frequency forcing. As St$_{D}$ decreased, vortex pairing was limited to a narrow region of the initial phase difference between two disturbances and higher amplitudes of the fundamental and its subharmonic at the nozzle exit were required for more stable pairing. As the amplitude of the subharmonic at the nozzle exit increased for fixed St$_{D}$ and fundamental amplitude, the distribution of the subharmonic mode against the variation of the initial phase difference changed from a sine function form into a cusp-like form. Thus, vortex pairing can be controlled more precisely for the former case. For St$_{D}$ > 0.6, non-pairing advection of vortices due to the improper phase difference was sometimes observed in several fundamental forcing amplitudes when only the fundamental was applied. However, when its subharmonic was added, vortex pairing readily occurred. As the initial amplitude of this subharmonic increased, the position of vortex pairing moved upstream. This was thought to be due to the fact that the variation of the initial phase difference between the fundamental and its subharmonic has less effects on vortex pairing in the region of fundamental-only vortex pairing.pairing.

Quadrangular Splatting based on SPH (SPH 기반의 사각 스플렛팅 가시화 기법)

  • Shin, Seung-Ho;Yoon, Jong-Chul;Lee, Jung;Kim, Chang-Hun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.14 no.4
    • /
    • pp.27-33
    • /
    • 2008
  • Physics-based graphic techniques are used when simulating and rendering natural phenomena such as smoke, water and flame with computational physics. We propose novel methods which render simulated particle data fast onto 3D using tetrahedron splat. We calculate the position and the normal vector of splat by SPH(smoothed particle hydrodynamics) method then we reconstruct splat into quadrangular pyramid to reduce seam. We implement this technique for SPH fluid simulation, and animate natural flow of water successfully.

  • PDF

Natural convection cooling of discrete heaters with same heat generation in a vertical open top cavity (상부가 개방된 수직 캐비티내에 장착된 불연속 균일 발열체의 자연대류 냉각)

  • Yu, Gap-Jong;Chu, Hong-Rok;Kim, Byeong-Ha;Choe, Byeong-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 1997
  • Natural convection cooling of discrete heaters located in a two-dimensional vertical open top cavity is investigated experimentally. The five discrete heaters with same heat generation are located on the wall of the cavity. The heaters are arranged in two configurations; flush-mounted on a vertical wall and protruding from the wall about 4.5 mm. The materials used for the vertical walls are copper and epoxy-resin, and air is used as the cooling fluid. The temperature and flow fields in the cavity were visualized by means of Mach-Zehnder interferometer and smoke-method. Also, local temperature measurements are made along the vertical wall. Results are obtained for cavity aspect ratios of 4.6, 7.5 and 9.5 and modified Rayleigh numbers ranging from 10$^{3}$ to 10$^{6}$ . Results indicate that the cooling efficiency for the copper wall is superior to that of the epoxy-resin. For the epoxy-resin wall, the protrusion of the heaters plays a role in decreasing the heat transfer performance. The location of maximum temperature is significantly influenced by the wall materials and heater configurations. Correlations relating the Nusselt number to the modified Rayleigh number are proposed.

The Effect of Control of the VGT and EGR in a Turbocharged Common-Rail Diesel Engine on Emissions under Partial Loads Conditions (부분부하에서 커먼레일 과급 디젤엔진의 VGT와 EGR 제어가 배출물에 미치는 영향)

  • Jeong, Soo-Jin;Chung, Jae-Woo;Kang, Jeong-Ho;Kang, Woo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.6
    • /
    • pp.151-158
    • /
    • 2007
  • The static and dynamic behaviour of VGT and EGR systems has a significant impact on overall engine performance, fuel economy and exhaust emissions. This is because they define the state and composition of the air charge entering the engine. This work focused on the effect of the aperture ratio of VGT and EGR on the emission and flow characteristics under partial loads conditions. The investigation carried out using 2 liter PCCI 4 cylinder diesel engine with VGT and EGR. The result of this study shows that smoke increases with increasing EGR rate and NOx decreases with increasing EGR rate. It was also found that the residual gas contents greatly impact on soot emission under partial load condition. Finally, it can be concluded that VGT and EGR aperture ratio can greatly impact not only on soot and NOx but also air charging.

Burner combustion characteristics of hybrid type water mixing emulsion fuel (하이브리드형 물혼합 에멀젼 연료의 버너 특성)

  • Kim, Cheol-Jeong;Kim, Dong-Kwon;Park, Kweon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.308-315
    • /
    • 2013
  • Water emulsion technology has the problem of unstable combustion due to the rapid separation of water. To solve the problem, a hybrid mixing device was developed. The device attached on the burner was tested. As a result, the fuel consumption reduced to 12% in the similar condition of exhaust emissions and flame temperature, and 45.5%, 98.5% and 97.2% of NOx, CO, and smoke were reduced at the same inlet air and fuel flow rate.

Design of Data Center Environmental Monitoring System Based On Lower Hardware Cost

  • Nkenyereye, Lionel;Jang, Jongwook
    • Journal of Multimedia Information System
    • /
    • v.3 no.3
    • /
    • pp.63-68
    • /
    • 2016
  • Environmental downtime produces a significant cost to organizations and makes them unable to do business because what happens in the data center affects everyone. In addition, the amount of electrical energy consumed by data centers increases with the amount of computing power installed. Installation of physical Information Technology and facilities related to environmental concerns, such as monitoring temperature, humidity, power, flood, smoke, air flow, and room entry, is the most proactive way to reduce the unnecessary costs of expensive hardware replacement or unplanned downtime and decrease energy consumed by servers. In this paper, we present remote system for monitoring datacenter implementing using open-source hardware platforms; Arduino, Raspberry Pi, and the Gobetwino. The sensed data displayed through Arduino are transferred using Gobetwino to the nearest host server such as temperature, humidity and distance every time an object hitting another object or a person coming in entrance. The raspberry Pi records the sensed data at the remote location. The objective of collecting temperature and humidity data allows monitoring of the server's health and getting alerts if things start to go wrong. When the temperature hits $50^{\circ}C$, the supervisor at remote headquarters would get a SMS, and then they would take appropriate actions to reduce electrical costs and preserve functionality of servers in data centers.

Exhaled Nitric Oxide(NO) Among Adult Male Workers (성인남성 근로자들의 호기중 일산화질소)

  • 하태규;백도명
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.3
    • /
    • pp.35-42
    • /
    • 2003
  • Nitric Oxide(NO) is produced in many organs of the body, including the lung and airways, and it is detectable in the exhaled air. The measurement of exhaled NO(eNO) provides a simple non-invasive means for measuring airway inflammation, such as asthma. We measured eNO among adult male workers to examine the distribution of eNO in healthy people and to find factors affecting eNO. We measured eNO in a sample of 921 adult workers who also performed lung function test and skin prick test. Exhaled NO was measured in a sitting posture without using a nose clip and NO free gas. NO was measured at three expiratory rates(l8; 42; 71 $m\ell$/sec) and the flow rate of 71 $m\ell$/sec was used in analysis. The average eNO concentration was 5.29 $\pm$ 2.98 ppb. The level increased with age but not significantly(P=0.0529). Exhaled NO showed positive relations to the height(P=0.0001), pollen 1 (P=0.0124), asthma history(P=0.0212), allergic rhinitis symptom(P=0.0302). Exhaled NO Concentration of smokers( 4.62 ppb) was significantly lower than that of nonsmokers(5.99 ppb; P<0.0001).

A Study on Reduction Method of Stack Effect at Stairwell of High-Rise Building (고층건물 피난계단에서의 연돌효과 저감방안 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.14-20
    • /
    • 2011
  • As the height of the building increases, the stack effect in stairwell that is main facilities for evacuation becomes stronger. While the pressure rise in stairwell causes difficulties on opening the door for evacuation and has effect on smoke control system, reduction of stack effect will be necessary for providing more safe evacuation environment. The field experiments on pressure field in high-rise building are carried out to present reduction method of stack effect and the numerical analyses using network model are proceeded to design quantitatively the reduction method. As the air flow supplied from outside in lower stair and exhausted to outside in upper stair is formed in stairwell, the stack effect in stairwell is expected to be decreased.