• Title/Summary/Keyword: Small park

Search Result 10,540, Processing Time 0.037 seconds

Modal Test of the 2nd Stage of Small Launch Vehicle (소형 위성 발사체 2단부 모드 시험)

  • Seo, Sang-Hyun;Jeong, Ho-Kyeong;Youn, Se-Hyun;Park, Soon-Hong;Jang, Young-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.258-261
    • /
    • 2006
  • The structure of small launch vehicle can be divided into engine section and payload section. This paper introduces modal test of the payload section of small launch vehicle which is composed to satellite, PLA (Payload Adapter), VEB (Vehicle Equipment Bay), KMS (Kick Motor Support) and KM (Kick Motor). From this test, dynamic properties of the 2nd stage structure of small launch vehicle can be obtained. In this test, to simulate free-free boundary condition, test object was hung by 4 bungee cords and excited by using impact hammer Modal test data are analyzed by using TDAS(Test Data Analysis Software). As the result, modal parameters and mode shapes below 100Hz of the 2nd stage of small launch vehicle were identified.

  • PDF

A Study on the Indwelled Accident Factors in Small & Medium-Sized Construction Sites Utilizing Safety Consulting Data (건설재해예방기술지도 결과자료 분석을 통한 중$\cdot$소 건설 현장의 잠재사고 유발 요인 개선 방안 연구)

  • Hong Sung Man;Yoon Young Goo;Kweon Dae Chul;Park Peom
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.3 s.67
    • /
    • pp.84-88
    • /
    • 2004
  • Accident of small and medium-sized construction sites happens much than large-sized construction sites. The safety consulting for accident prevention of construction sites has been launched in 1995. This research probed latency accident of small and medium-sized construction sites. By method, we used that result data of safety consulting for accident prevention of small and medium-sized construction sites. As a result a fall was examined by the most latency accident factor. In this study, a fall and electric shock, descent, fall down in ground, a fire was examined weighty accident factor of small and medium-sized construction sites.

Feasibility Assessment of Small Hydro Power Plants Using Diversion Weirs for Agricultural Purpose (농업용 보를 이용한 소수력발전소의 타당성 분석)

  • Lee, Chul-Hyung;Park, Wan-Soon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.229-234
    • /
    • 2011
  • Feasibility assessment for small hydropower plants using diversion weirs located in stream for agricultural purpose has been studied. The model, which can predict flow duration characteristic of stream, was developed to analyze the inflow caused from rainfall. And another model to predict hydrologic performance for small hydropower plants is established. Preliminary survey was performed identifying several candidate sites, and two sites were selected finally for actual site reconnaissance. During the course of site survey, generating capacity, construction and equipment cost, and payback through life time of each sites were calculated for economical feasibility analysis. The results of this study have estimated that the small hydropower plants using diversion weirs for agricultural purpose may offer better opportunities in future with increasing fuel cost and nation's energy policy.

  • PDF

Elastic High-temperature Structural Analysis on the Small Scale PHE Prototype Considering the Pipeline Stiffness (배관 강성을 고려한 소형 공정열교환기 시제품에 대한 탄성 고온구조해석)

  • Song, Kee-nam;Kang, J-H;Hong, S-D;Park, H-Y
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.48-53
    • /
    • 2011
  • A PHE (Process Heat Exchanger) is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature Reactor) to the chemical reaction that yields a large quantity of hydrogen. A small-scale PHE prototype made of Hastelloy-X is being tested in a small-scale gas loop at Korea Atomic Energy Research Institute. In this study, as a part of the evaluation on the high-temperature structural integrity of the small-scale PHE prototype, we carried out macroscopic high-temperature structural analysis of the small-scale PHE prototype under the gas loop test conditions considering the pipeline stiffness.

A Simplified MES Implementation for Small-sized Manufacturing Industries with EXCEL VBA (EXCEL VBA를 이용한 중소제조업체용 간이형 MES 구축)

  • Park, Jeong-Hyeon;Yoshida, Atsunori
    • IE interfaces
    • /
    • v.22 no.4
    • /
    • pp.302-311
    • /
    • 2009
  • It's very important to make an effective and optimized production schedule for the small-to-medium-sized factory which have high-variety low-volume manufacturing properties. And now people say that MES is very useful to make scheduling more effectively. But for small-to-medium-sized factory, it is very difficult to build MES system because of fewer infrastructures in the factory, and more to keep it's continuous maintenance and improvement. Therefore it is more important to systematize the production scheduling generation using simpler and easier tools like EXCEL sheet. And it will be needed a new method to make simple MES construction for more efficient production scheduling. This paper proposes the method which can build simple MES easily using a tool of EXCEL VBA for a small-to-medium-sized factory, and introduces an applied case by the proposed method and EXCEL VBA.

Development of Evaluation Method and Experimental Verification of a 300kW Small Engine Cogeneration System (300kW급 소형 엔진 열병합발전시스템의 평가기술 개발 및 실증시험)

  • Choi, Jae-Joon;Park, Hwa-Choon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.453-458
    • /
    • 2007
  • The importance of the evaluation and verification of small-size cogeneration system has been emphasized because there is no KS-code related to the small-size cogeneration system. The evaluation method of small-size engine cogeneration system was investigated by the reference of Japan evaluation code, JIS B-8122 and international standard organization, ISO-8528. Evaluation method was introduced such as start-test, rapid-load-up and rapid-load-down, etc. The evaluation method was applied to the 300kW small-size gas engine cogeneration system newly developed. The precise and strict evaluation and verification of the system will help the developing cogeneration system to optimum condition. It will also be a base document of KS-Code.

  • PDF

Modeling and Small-Signal Analysis of Controlled On-time Boost Power Factor Correction Circuit (도통 시간 제어형 승압형 역률보상회로의 모델링과 소신호 해석)

  • Park, Hyo-Gil;Hong, Seong-Su;Choe, Byeong-Jo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.5
    • /
    • pp.364-370
    • /
    • 2000
  • A large-signal average model for the controlled on-time boost power factor correction(PFC) circuit is developed and subsequently linearized resulting in a small-signal model for the PFC circuit. Ac analyses are performed using the small-signal model, revealing new results new on small-signal dynamics of the PFC circuit. The analysis results and model predictions are confirmed with experimental measurements on 200W prototype PFC circuit.

  • PDF

FPGA based POS MPPT Control for a Small Scale Charging System of PV-nickel Metal Hydride Battery (FPGA를 이용한 소형 태양광 발전 니켈 수소 전지 충전 시스템의 POS MPPT 제어)

  • Lee, Hyo-Guen;Seo, Hyo-Ryong;Kim, Gyeong-Hun;Park, Min-Won;Yu, In-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.80-84
    • /
    • 2012
  • Recently, the small scale photovoltaic (PV) electronic devices are drawing attention as the upcoming PV generation system. The PV system is commonly used in small scale PV applications such as LED lighting and cell phone. This paper proposes photovoltaic output sensorless (POS) maximum power point tracking (MPPT) control for a small scale charging system of PV-nickel metal hydride battery using field-programmable gate array (FPGA) controller. A converter is connected to a small scale PV cell and battery, and performs the POS MPPT at the battery terminal current instead of being at the PV cell output voltage and current. The FPGA controller and converter operate based on POS MPPT method. The experimental results show that the nickel metal hydride battery is charged by the maximum PV output power.

Output Characteristic Analysis of Small Hydropower Plant (소수력발전소의 출력특성 분석)

  • Park, Wan-Soon;Lee, Chul-Hyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.491-494
    • /
    • 2006
  • The output performance characteristics for surveyed sites were analyzed, using developed model. It consists of two main parts, the deciding flow duration characteristic of river and performance prediction model to estimate the output characteristics of small hydropower plants. As a result, it was found that the flowrate concerning with 25% of time ratio on flow duration curve can be selected to design flowrate of small hydropower plants, and the output characteristics of small hydropower plants having overflow dam are different from large scale hydropower plants.

  • PDF

A File Merging Scheme for Efficient Handling of Small Files in Hadoop Distributed File System (Hadoop Distribute file system에서 Small file을 효과적으로 처리하기 위한 파일 병합 기법 연구)

  • Park, Jong-Chang;Youn, Hee-Yong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.11a
    • /
    • pp.15-17
    • /
    • 2013
  • HDFS(Hadoop Distribute File System)는 대용량 파일 처리를 목적으로 설계 되었으며 현재 이상적인 분산 파일 시스템으로 각광 받고 있다. 이러한 HDFS는 기존 분산파일 시스템과 많은 유사성을 가지고 있으나, Fault Tolerance를 제공하고, 데이터 엑세스 패턴을 스트리밍 방식으로 지원하여 대용량 파일을 효율적으로 저장할 수 있다는 차별성을 가지고 있다. 하지만 실제 HDFS 데이터 집합에는 Small file이 차지하는 비중이 상당히 높으며, 이러한 다수의 Small file 은 데이터 처리에 있어 높은 비용을 초래할 뿐 아니라 Master Node 의 파일 처리 및 메모리 성능에 악영향을 미친다. 따라서 본 논문에서는 HDFS에서 Small file 이 미치는 영향을 분석하고 이러한 문제점을 해결 할 수 있는 로컬 인덱스 파일기반의 파일 병합 기법을 제안한다.