• Title/Summary/Keyword: Small Image

Search Result 2,352, Processing Time 0.031 seconds

Multi-resolution SAR Image-based Agricultural Reservoir Monitoring (농업용 저수지 모니터링을 위한 다해상도 SAR 영상의 활용)

  • Lee, Seulchan;Jeong, Jaehwan;Oh, Seungcheol;Jeong, Hagyu;Choi, Minha
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_1
    • /
    • pp.497-510
    • /
    • 2022
  • Agricultural reservoirs are essential structures for water supplies during dry period in the Korean peninsula, where water resources are temporally unequally distributed. For efficient water management, systematic and effective monitoring of medium-small reservoirs is required. Synthetic Aperture Radar (SAR) provides a way for continuous monitoring of those, with its capability of all-weather observation. This study aims to evaluate the applicability of SAR in monitoring medium-small reservoirs using Sentinel-1 (10 m resolution) and Capella X-SAR (1 m resolution), at Chari (CR), Galjeon (GJ), Dwitgol (DG) reservoirs located in Ulsan, Korea. Water detected results applying Z fuzzy function-based threshold (Z-thresh) and Chan-vese (CV), an object detection-based segmentation algorithm, are quantitatively evaluated using UAV-detected water boundary (UWB). Accuracy metrics from Z-thresh were 0.87, 0.89, 0.77 (at CR, GJ, DG, respectively) using Sentinel-1 and 0.78, 0.72, 0.81 using Capella, and improvements were observed when CV was applied (Sentinel-1: 0.94, 0.89, 0.84, Capella: 0.92, 0.89, 0.93). Boundaries of the waterbody detected from Capella agreed relatively well with UWB; however, false- and un-detections occurred from speckle noises, due to its high resolution. When masked with optical sensor-based supplementary images, improvements up to 13% were observed. More effective water resource management is expected to be possible with continuous monitoring of available water quantity, when more accurate and precise SAR-based water detection technique is developed.

A Case Study on the Design of Pickup Truck Tuning Equipment according to the Lifestyle of Modern People (현대인의 라이프스타일에 따른 픽업트럭 튜닝 용품 디자인 사례 연구)

  • Lee, Dong-Hun;Park, Hae-Lim;Lee, Sang-Ki
    • Journal of Service Research and Studies
    • /
    • v.13 no.4
    • /
    • pp.131-141
    • /
    • 2023
  • Changes in consumer needs and behaviors according to lifestyle changes lead to consumption culture, affecting the automobile market. However, research and research to provide options tailored to the lifestyle of consumers in related markets are still insufficient. Focusing on pickup truck accessories applied to pickup trucks that reflect lifestyle the most among vehicle types, this study first examined the theoretical background of the aftermarket market and lifestyle of pickup trucks. Second, through image mapping, the market possibilities and opportunity factors of pickup trucks were discovered through market size analysis and possibilities, and through this, user types could be classified. Third, interviews were conducted with those representing user types, the contents were organized, and interviews were conducted centering on related groups to create a persona of a user group, and what needs each group's persona wanted. Finally, a design concept suitable for the issue keywords and insights derived for each user lifestyle type was presented. In this study, the user type was divided into ① outdoor activity type, ② hobby activity type, and ③ small-scale work type, and a design case study was conducted by applying the concept suitable for the keyword for each group. For the outdoor activity type, a variable storage structure and a living space-type accessory design were presented, and for the hobby type, a modular decktop design and a sports coupe-type hardtop design were presented. For the small business type, a partition that is easy to fix the load and a stepper design that is easy to board the cargo box were presented. It is expected that the size of the pickup truck aftermarket will be expanded by diversifying the option designs that users want by lifestyle by applying them to the development of pickup truck accessories that fit the lifestyle of pickup truck users in the automobile market, which is currently mass customized.

A Study on the Meaning and Strategy of Keyword Advertising Marketing

  • Park, Nam Goo
    • Journal of Distribution Science
    • /
    • v.8 no.3
    • /
    • pp.49-56
    • /
    • 2010
  • At the initial stage of Internet advertising, banner advertising came into fashion. As the Internet developed into a central part of daily lives and the competition in the on-line advertising market was getting fierce, there was not enough space for banner advertising, which rushed to portal sites only. All these factors was responsible for an upsurge in advertising prices. Consequently, the high-cost and low-efficiency problems with banner advertising were raised, which led to an emergence of keyword advertising as a new type of Internet advertising to replace its predecessor. In the beginning of 2000s, when Internet advertising came to be activated, display advertisement including banner advertising dominated the Net. However, display advertising showed signs of gradual decline, and registered minus growth in the year 2009, whereas keyword advertising showed rapid growth and started to outdo display advertising as of the year 2005. Keyword advertising refers to the advertising technique that exposes relevant advertisements on the top of research sites when one searches for a keyword. Instead of exposing advertisements to unspecified individuals like banner advertising, keyword advertising, or targeted advertising technique, shows advertisements only when customers search for a desired keyword so that only highly prospective customers are given a chance to see them. In this context, it is also referred to as search advertising. It is regarded as more aggressive advertising with a high hit rate than previous advertising in that, instead of the seller discovering customers and running an advertisement for them like TV, radios or banner advertising, it exposes advertisements to visiting customers. Keyword advertising makes it possible for a company to seek publicity on line simply by making use of a single word and to achieve a maximum of efficiency at a minimum cost. The strong point of keyword advertising is that customers are allowed to directly contact the products in question through its more efficient advertising when compared to the advertisements of mass media such as TV and radio, etc. The weak point of keyword advertising is that a company should have its advertisement registered on each and every portal site and finds it hard to exercise substantial supervision over its advertisement, there being a possibility of its advertising expenses exceeding its profits. Keyword advertising severs as the most appropriate methods of advertising for the sales and publicity of small and medium enterprises which are in need of a maximum of advertising effect at a low advertising cost. At present, keyword advertising is divided into CPC advertising and CPM advertising. The former is known as the most efficient technique, which is also referred to as advertising based on the meter rate system; A company is supposed to pay for the number of clicks on a searched keyword which users have searched. This is representatively adopted by Overture, Google's Adwords, Naver's Clickchoice, and Daum's Clicks, etc. CPM advertising is dependent upon the flat rate payment system, making a company pay for its advertisement on the basis of the number of exposure, not on the basis of the number of clicks. This method fixes a price for advertisement on the basis of 1,000-time exposure, and is mainly adopted by Naver's Timechoice, Daum's Speciallink, and Nate's Speedup, etc, At present, the CPC method is most frequently adopted. The weak point of the CPC method is that advertising cost can rise through constant clicks from the same IP. If a company makes good use of strategies for maximizing the strong points of keyword advertising and complementing its weak points, it is highly likely to turn its visitors into prospective customers. Accordingly, an advertiser should make an analysis of customers' behavior and approach them in a variety of ways, trying hard to find out what they want. With this in mind, her or she has to put multiple keywords into use when running for ads. When he or she first runs an ad, he or she should first give priority to which keyword to select. The advertiser should consider how many individuals using a search engine will click the keyword in question and how much money he or she has to pay for the advertisement. As the popular keywords that the users of search engines are frequently using are expensive in terms of a unit cost per click, the advertisers without much money for advertising at the initial phrase should pay attention to detailed keywords suitable to their budget. Detailed keywords are also referred to as peripheral keywords or extension keywords, which can be called a combination of major keywords. Most keywords are in the form of texts. The biggest strong point of text-based advertising is that it looks like search results, causing little antipathy to it. But it fails to attract much attention because of the fact that most keyword advertising is in the form of texts. Image-embedded advertising is easy to notice due to images, but it is exposed on the lower part of a web page and regarded as an advertisement, which leads to a low click through rate. However, its strong point is that its prices are lower than those of text-based advertising. If a company owns a logo or a product that is easy enough for people to recognize, the company is well advised to make good use of image-embedded advertising so as to attract Internet users' attention. Advertisers should make an analysis of their logos and examine customers' responses based on the events of sites in question and the composition of products as a vehicle for monitoring their behavior in detail. Besides, keyword advertising allows them to analyze the advertising effects of exposed keywords through the analysis of logos. The logo analysis refers to a close analysis of the current situation of a site by making an analysis of information about visitors on the basis of the analysis of the number of visitors and page view, and that of cookie values. It is in the log files generated through each Web server that a user's IP, used pages, the time when he or she uses it, and cookie values are stored. The log files contain a huge amount of data. As it is almost impossible to make a direct analysis of these log files, one is supposed to make an analysis of them by using solutions for a log analysis. The generic information that can be extracted from tools for each logo analysis includes the number of viewing the total pages, the number of average page view per day, the number of basic page view, the number of page view per visit, the total number of hits, the number of average hits per day, the number of hits per visit, the number of visits, the number of average visits per day, the net number of visitors, average visitors per day, one-time visitors, visitors who have come more than twice, and average using hours, etc. These sites are deemed to be useful for utilizing data for the analysis of the situation and current status of rival companies as well as benchmarking. As keyword advertising exposes advertisements exclusively on search-result pages, competition among advertisers attempting to preoccupy popular keywords is very fierce. Some portal sites keep on giving priority to the existing advertisers, whereas others provide chances to purchase keywords in question to all the advertisers after the advertising contract is over. If an advertiser tries to rely on keywords sensitive to seasons and timeliness in case of sites providing priority to the established advertisers, he or she may as well make a purchase of a vacant place for advertising lest he or she should miss appropriate timing for advertising. However, Naver doesn't provide priority to the existing advertisers as far as all the keyword advertisements are concerned. In this case, one can preoccupy keywords if he or she enters into a contract after confirming the contract period for advertising. This study is designed to take a look at marketing for keyword advertising and to present effective strategies for keyword advertising marketing. At present, the Korean CPC advertising market is virtually monopolized by Overture. Its strong points are that Overture is based on the CPC charging model and that advertisements are registered on the top of the most representative portal sites in Korea. These advantages serve as the most appropriate medium for small and medium enterprises to use. However, the CPC method of Overture has its weak points, too. That is, the CPC method is not the only perfect advertising model among the search advertisements in the on-line market. So it is absolutely necessary that small and medium enterprises including independent shopping malls should complement the weaknesses of the CPC method and make good use of strategies for maximizing its strengths so as to increase their sales and to create a point of contact with customers.

  • PDF

Comparison of CT based-CTV plan and CT based-ICRU38 plan in Brachytherapy Planning of Uterine Cervix Cancer (자궁경부암 강내조사 시 CT를 이용한 CTV에 근거한 치료계획과 ICRU 38에 근거한 치료계획의 비교)

  • Cho, Jung-Ken;Han, Tae-Jong
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • Purpose : In spite of recent remarkable improvement of diagnostic imaging modalities such as CT, MRI, and PET and radiation therapy planing systems, ICR plan of uterine cervix cancer, based on recommendation of ICRU38(2D film-based) such as Point A, is still used widely. A 3-dimensional ICR plan based on CT image provides dose-volume histogram(DVH) information of the tumor and normal tissue. In this study, we compared tumor-dose, rectal-dose and bladder-dose through an analysis of DVH between CTV plan and ICRU38 plan based on CT image. Method and Material : We analyzed 11 patients with a cervix cancer who received the ICR of Ir-192 HDR. After 40Gy of external beam radiation therapy, ICR plan was established using PLATO(Nucletron) v.14.2 planing system. CT scan was done to all the patients using CT-simulator(Ultra Z, Philips). We contoured CTV, rectum and bladder on the CT image and established CTV plan which delivers the 100% dose to CTV and ICRU plan which delivers the 100% dose to the point A. Result : The volume$(average{\pm}SD)$ of CTV, rectum and bladder in all of 11 patients is $21.8{\pm}6.6cm^3,\;60.9{\pm}25.0cm^3,\;111.6{\pm}40.1cm^3$ respectively. The volume covered by 100% isodose curve is $126.7{\pm}18.9cm^3$ in ICRU plan and $98.2{\pm}74.5cm^3$ in CTV plan(p=0.0001), respectively. In (On) ICRU planning, $22.0cm^3$ of CTV volume was not covered by 100% isodose curve in one patient whose residual tumor size is greater than 4cm, while more than 100% dose was irradiated unnecessarily to the normal organ of $62.2{\pm}4.8cm^3$ other than the tumor in the remaining 10 patients with a residual tumor less than 4cm in size. Bladder dose recommended by ICRU 38 was $90.1{\pm}21.3%$ and $68.7{\pm}26.6%$ in ICRU plan and in CTV plan respectively(p=0.001) while rectal dose recommended by ICRU 38 was $86.4{\pm}18.3%$ and $76.9{\pm}15.6%$ in ICRU plan and in CTV plan, respectively(p=0.08). Bladder and rectum maximum dose was $137.2{\pm}50.1%,\;101.1{\pm}41.8%$ in ICRU plan and $107.6{\pm}47.9%,\;86.9{\pm}30.8%$ in CTV plan, respectively. Therefore, the radiation dose to normal organ was lower in CTV plan than in ICRU plan. But the normal tissue dose was remarkably higher than a recommended dose in CTV plan in one patient whose residual tumor size was greater than 4cm. The volume of rectum receiving more than 80% isodose (V80rec) was $1.8{\pm}2.4cm^3$ in ICRU plan and $0.7{\pm}1.0cm^3$ in CTV plan(p=0.02). The volume of bladder receiving more than 80% isodose(V80bla) was $12.2{\pm}8.9cm^3$ in ICRU plan and $3.5{\pm}4.1cm^3$ in CTV plan(p=0.005). According to these parameters, CTV plan could also save more normal tissue compared to ICRU38 plan. Conclusion : An unnecessary excessive radiation dose is irradiated to normal tissues within 100% isodose area in the traditional ICRU plan in case of a small size of cervix cancer, but if we use CTV plan based on CT image, the normal tissue dose could be reduced remarkably without a compromise of tumor dose. However, in a large tumor case, we need more research on an effective 3D-planing to reduce the normal tissue dose.

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

GET Imaging Evaluation of Patients with Esophageal Cancer (식도암 환자의 GET 영상 평가)

  • Moon, Jong Wun;Lee, Chung Wun;Seo, Young Deok;Yun, Sang Hyeok;Kim, Yong Keun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • Purpose: Measure gastric emptying time (GET: Gastric Emptying Time) is a non-invasive and quantitative evaluation methods, mainly by endoscopic or radiological examination confirmed no mechanical obstruction in patients with symptoms of congestion is checked. Such tests are not common gastric emptying time measured esophageal cancer patients (who underwent esophagectomy) patients after surgery for gastric emptying time was measured test. And the period of time for more than one year after the gastric emptying time measurement was performed. By comparing the two kinds of tests in the chest cavity after surgery as the evaluation of gastrointestinal function tests evaluate the usefulness of GET, and will evaluate the characteristics of the image. Materials and Methods: 93 patients who underwent esophagectomy with gastric emptying time measurement of subject tests immediately after surgery and after 1 year or longer were twice. Preparation of the patient before the test is more than 12 hours of overnight fasting is important, in addition to the medicine or to stop smoking, and diabetes insulin injections should be early in the morning is ideal to test. Generally labeled with $^{99m}Tc-DTPA$ resin which is used to make steamed egg, seaweed and fermented milk with a high viscosity after eating, three hours in the standing position was measured. Evaluation of gastric emptying curves on the way intragastric radioactivity level by 50% the time (half-time [T1/2]) was calculated, based on the half-life was divided into three steps: over 180 minutes was defined as delayed gastric emptying, within 180minutes was defined as intermediate gastric emptying and when all the radioisotopes were dumped into the jejunum as soon as swallowed, was defined as rapid gastric emptying. Results: Gastric emptying time of a typical images stomach of antrum and fundus additional images appear stronger over time move on to the small intestine. but esophageal cancer who underwent esophagectomy side of the thoracic cavity showed a strong image. Immediately after surgery, the half-time (T1/2) of rapid gastric emptying appeared to 12.9%, intermediate gastric emptying appeared to 52.7%, delay gastric emptying appeared to 34.4%. After more than a year the results of the half-life after surgery, 67% of rapid gastric emptying to intermediate gastric emptying was changed, 69% of delay gastric emptying to intermediate gastric emptying changed. Intermediate gastric emptying worse in patients rapid gastric emptying and the delay gastric emptying is 24% in the case. Conclusion: Esophagectomy for esophageal cancer who underwent half-time measurement test (T1/2) rapid gastric emptying and delay gastric emptying are the result of the comparison over time, changes were observed intermediate gastric emptying. Mainly seeing of gastric emptying time measurement in the esophagus instead of thoracic cavity to check the evaluation of gastrointestinal function can be useful even means. And segmentation criteria and narrow time interval of checking if more accurate information and analysis of the clinical diagnosis and evaluation seems to be done.

  • PDF

Quantitative Assessment Technology of Small Animal Myocardial Infarction PET Image Using Gaussian Mixture Model (다중가우시안혼합모델을 이용한 소동물 심근경색 PET 영상의 정량적 평가 기술)

  • Woo, Sang-Keun;Lee, Yong-Jin;Lee, Won-Ho;Kim, Min-Hwan;Park, Ji-Ae;Kim, Jin-Su;Kim, Jong-Guk;Kang, Joo-Hyun;Ji, Young-Hoon;Choi, Chang-Woon;Lim, Sang-Moo;Kim, Kyeong-Min
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.42-51
    • /
    • 2011
  • Nuclear medicine images (SPECT, PET) were widely used tool for assessment of myocardial viability and perfusion. However it had difficult to define accurate myocardial infarct region. The purpose of this study was to investigate methodological approach for automatic measurement of rat myocardial infarct size using polar map with adaptive threshold. Rat myocardial infarction model was induced by ligation of the left circumflex artery. PET images were obtained after intravenous injection of 37 MBq $^{18}F$-FDG. After 60 min uptake, each animal was scanned for 20 min with ECG gating. PET data were reconstructed using ordered subset expectation maximization (OSEM) 2D. To automatically make the myocardial contour and generate polar map, we used QGS software (Cedars-Sinai Medical Center). The reference infarct size was defined by infarction area percentage of the total left myocardium using TTC staining. We used three threshold methods (predefined threshold, Otsu and Multi Gaussian mixture model; MGMM). Predefined threshold method was commonly used in other studies. We applied threshold value form 10% to 90% in step of 10%. Otsu algorithm calculated threshold with the maximum between class variance. MGMM method estimated the distribution of image intensity using multiple Gaussian mixture models (MGMM2, ${\cdots}$ MGMM5) and calculated adaptive threshold. The infarct size in polar map was calculated as the percentage of lower threshold area in polar map from the total polar map area. The measured infarct size using different threshold methods was evaluated by comparison with reference infarct size. The mean difference between with polar map defect size by predefined thresholds (20%, 30%, and 40%) and reference infarct size were $7.04{\pm}3.44%$, $3.87{\pm}2.09%$ and $2.15{\pm}2.07%$, respectively. Otsu verse reference infarct size was $3.56{\pm}4.16%$. MGMM methods verse reference infarct size was $2.29{\pm}1.94%$. The predefined threshold (30%) showed the smallest mean difference with reference infarct size. However, MGMM was more accurate than predefined threshold in under 10% reference infarct size case (MGMM: 0.006%, predefined threshold: 0.59%). In this study, we was to evaluate myocardial infarct size in polar map using multiple Gaussian mixture model. MGMM method was provide adaptive threshold in each subject and will be a useful for automatic measurement of infarct size.

An Exploratory Study on the Effects of Relational Benefits and Brand Identity : mediating effect of brand identity (관계혜택과 브랜드 동일시의 역할에 관한 탐색적 연구: 브랜드 동일시의 매개역할을 중심으로)

  • Bang, Jounghae;Jung, Jiyeon;Lee, Eunhyung;Kang, Hyunmo
    • Asia Marketing Journal
    • /
    • v.12 no.2
    • /
    • pp.155-175
    • /
    • 2010
  • Most of the service industries including finance and telecommunications have become matured and saturated. The competitions have become severe while the differences among brands become smaller. Therefore maintaining good relationships with customers has been critical for the service providers. In case of credit card and debit card, the similar patterns are shown. It is important for them to maintain good relationships with customers, and therefore, they have used marketing program which provides customized services to customers and utilizes the membership programs. Not only do they build and maintain good relationships, but also highlight their brands from the emotional aspects. For example, KB Card or Hyundai Card uses well-known designers' works for their credit card design. As well, they differentiate the designs of credit cards to stress on their brand personalities. BC Card introduced the credit card with perfume that a customer would like. Even though the credit card is small and not shown to public easily, it becomes more important for those companies to touch the customers' feelings with the brand personalities and their images. This is partly because of changes in consumers' lifestyles. Y-generations becomes highly likely to express themselves in many different ways and more emotional than X-generations. For the Y-generations, therefore, even credit cards in the wallet should be personalized and well-designed. In line with it, credit cards with good design can be seen as an example of brand identity, where different design for each customer can be used to recognize the membership groups that customers want to belong. On the other hand, these credit card companies offer the special treatment benefits for those customers who are heavy users for the cards. For example, those customers who love sports will receive some special discounts when they use their credit cards for sports related products. Therefore this study attempted to explore the relationships between relational benefits, brand identification and loyalty. It has been well known that relational benefits and brand identification lead to loyalty independently from many other studies, but there has been few study to review all the three variables all together in a research model. Furthermore, as reviewed above, in the card industry, many companies attempt to associate the brand image with their products to fit their customers' lifestyles while relational benefits are still playing an important role for their business. Therefore in our research model, relational benefits, brand identification, and loyalty are all included. We focus on the mediating effect of brand identification. From the relational benefits perspective, only special treatment benefit and confidence benefit are included. Social benefit is not applicable for this credit card industry because not many cases of face-to-face interaction can be found. From the brand identification perspective, personal brand identity and social brand identity are reviewed and included in the model. Overall, the research model emphasizes that the relationships between relational benefits and loyalty will be mediated by the effect of brand identification. The effects of relational benefits which are confidence benefit and special treatment benefits on loyalty will be realized when they fit to the personal brand identity and social brand identity. In the research model, therefore, the relationships between confidence benefit and social brand identity, and between confidence benefit and personal identity are hypothesized while the effects of special treatment benefit on social brand identity and personal brand identity are hypothesized. Loyalty, then, is hypothesized to have positive relationships with personal brand identity and social brand identity. In addition, confidence benefit among the relational benefits is expected to have a direct, positive relationship with loyalty because confidence benefit has been recognized as a critical factor for good relationships and satisfaction. Data were collected from college students who have been using either credit cards or debit cards. College students were regarded good subjects because they are in Y-generation cohorts and have tendency to express themselves more. Total sample size was two hundred three at the beginning, but after deleting those data with many missing values, one hundred ninety-seven data points were remained and used for the model testing. Measurement items were brought from the previous literatures and modified for this research. To test the reliability, using SPSS 14, chronbach's α was examined and all the values were from .874 to .928 exceeding over .7. Using AMOS 7.0, confirmatory factor analysis was conducted to investigate the measurement model. The measurement model was found good fit with χ2(67)=188.388 (p= .000), GFI=.886, AGFI=.821, CFI=.941, RMSEA=.096. Using AMOS 7.0, structural equation modeling has been used to analyze the research model. Overall, the research model fit were χ2(68)=188.670 (p= .000), GFI=.886, AGFI=,824 CFI=.942, RMSEA=.095 indicating good fit. In details, all the paths hypothesized in the research model were found significant except for the path from social brand identity to loyalty. Personal brand identity leads to loyalty while both confidence benefit and special treatment benefit have a positive relationships with personal and social identities. As well, confidence benefit has a direct positive effect on loyalty. The results indicates the followings. First, personal brand identity plays an important role for credit/debit card usage. Therefore even for the products which are not shown to public easy, design and emotional aspect can be important to fit the customers' lifestyles. Second, confidence benefit and special treatment benefit have a positive effects on personal brand identity. Therefore it will be needed for marketers to associate the special treatment and trust and confidence benefits with personal image, personality and personal identity. Third, this study found again the importance of confidence and trust. However interestingly enough, social brand identity was not found to be significantly related to loyalty. It can be explained that the main sample of this study consists of college students. Those strategies to facilitate social brand identity are focused on high social status groups while college students have not been established their status yet.

  • PDF

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF

The Evaluation of Clinical Usefulness on Application of Myocardial Extract in Quantitative Perfusion SPECT (QPS 프로그램에서 Myocardial extract 적용에 따른 임상적 유용성 평가)

  • Yun, Jong-Jun;Lim, Yeong-Hyeon;Lee, Mu-Seok;Song, Hyeon-Seok;Jeong, Ji-Uk;Park, Se-Yun;Kim, Jae-Hwan;Kim, Jeong-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.88-93
    • /
    • 2011
  • Purpose: As to analytical method of data, the AutoQUANT software in which it is used quantitative rating of the myocardial perfusion SPECT are reported that there is a difference. Therefore the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made data of the same patient. The purpose of this study is to offer the comparative analysis of myocardial extract method in Quantitative Perfusion SPECT. Materials and methods: We analyzed the 51 patients who were examined by Tc-99m MIBI gated myocardial SPECT in nuclear medicine department of Pusan National University Hospital from June to December 2010(34 men, 17 women, mean age $66.5{\pm}9.9$). We acquired the extracted image in myocardial extract protocol. QPS program that uses the AutoQUANT software measured TID(Transient Ischemic Dilation), ESD(Extent of Stress Defect), SSS(Summed Stress Score). Then analyzed the results. Results: The correlation of appyling myocardial extract is TID(r=0.98), ESD(r=0.99), SSS(r=0.99). In the 95% confidence limit, there was no satistically significant difference(TID p=0.78, ESD p=0.31, SSS p=0.19). After blinding test with a physician for making a qualitative analysis, there was no difference. Conclusion: Quantitative indices in QPS program showed good correlation and the results showed no statistically signigicant difference. The variance between method was small. therefore, the functional parameters by each method can be used interchangeably. Also, we expect patient's satisfaction.

  • PDF