• Title/Summary/Keyword: Sludge Interface

Search Result 26, Processing Time 0.025 seconds

THE EFFECT OF THE INTERFACE ACTIVE MATERIAL ON THE TRACKING FAILURE (TRACKING 파괴(破壞)에 미치는 계면활성(界面活性)의 영향)

  • Lee, Bo-Ho;Park, Dong-Wha;Ko, In-Whan
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.486-488
    • /
    • 1987
  • Studine the characteristic or C.T.I affectine on the tracking failure when interface active materials are diffused into the phenolic resin. we conclude as follow: 1) As the density of $NH_4Cl$ increase the quality or sludge increase the value of C.T.I decreases. 2) The materal of ion absorption can make the period of sludge metallic matal generation delay more than times and the value of C.T.I increase. 3) By addition of interface active material that makes forming period delay, the starting voltage of corona blackdown id delayed and the value of C.T.I is increased.

  • PDF

Dewatering Characteristics of Sewage Sludge Produced by the Biological Treatment Process (도시하수 슬러지의 탈수특성 연구)

  • Lee, Jae Bok;Hwang, Jung Wuk;Kwon, Il;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.2
    • /
    • pp.84-96
    • /
    • 1995
  • The dewatering characteristics of the sewage sludge was investigated through the experimental observations and model simulations. The activated sludge and the anaerobically digested sludge were examined for the dewaterability evaluation within the pressure range of $0{\sim}10^6N/m^2$. Modified Buchner funnel test and compression test by the consolidometer were conducted to evaluate average specific resistance, porosity, and moisture percentage of filter cake. Shirato's technique of compression-permeability test was followed for the pressure range lower than about $10^2N/m^2$. The flocculation effects on sludge dewatering was also examined for ferric chloride and polymeric flocculant. The application of hydrated lime which can be used for flue-gas desulfurization showed improved moisture percentage, and was thought to have positive feasibility in combined system of sludge dewatering and incineration. Determined characteristic constants were applied to Tiller's cake filtration model to simulate liquid pressure distribution and porosity distribution in cake. Model simulations showed a sharp drop of the porosity close to the cake-medium interface for the highly compressible material such as the activated sludge and the anaerobically digested sludge.

  • PDF

Thickening of Bulking Sludge using DAF (Dissolved Air Flotation) (DAF(Dissolved Air Flotation)를 이용한 팽화 슬러지 농축)

  • Kim Dong-Seog;Park Young-Seek
    • Journal of Environmental Science International
    • /
    • v.15 no.1
    • /
    • pp.77-84
    • /
    • 2006
  • An effective technique of sludge separation is required for excess sludge of sewage or wastewater plant. The separation of bulking sludge of paper manufacturing plant was studied using DAF(Dissolved Air Flotation) system. The effects of parameters such as nozzle type, A/S(air/solid) ratio. pressure, injection time of pressured water and saturation time were examined. The results showed that the best nozzle type was flat which had small orifice hole, The optimum A/S ratio and pressure were $7.070\times10^{-3}$(recycle ratio of pressured water $20\%$) and 5atm, respectively. Injection times of pressurized water around 20-25 sesc and flotation time of 30 min appeared to be optimal for the DAF operation. The order of performance of packing was 18 mm > 22 mm > 32 mm.

Effective correlation between coagulation efficiency and the sludge settling characteristic (슬러지 응집효율이 침강특성에 미치는 상관관계에 대한 연구)

  • Han, Gee-Bong;Yoon, Ji-Hyun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.1
    • /
    • pp.151-159
    • /
    • 2006
  • In these days, the importance of sludge treatment is emerging due to the London Convention, so this study was conducted to propose the alternatives for the improved sludge treatment on the organic wastewater and sewage sludge with JAR test and settling column equipped with stirrer. The minimum coagulant dosage to earn the optimum sludge settling efficiency resulted from 200mg/l and each critical sludge settling interface showed no distinct difference when PAC was dosed over 200mg/l. Accordingly, Clarification Rate(CR) with 200mg/l dosage was calculated to CR=(Ho-Ht) / Ho=1-0.4=0.6 because the critical sludge settling height stopped at 0.4. The settling velocity of sludge interface was decreased with the increase of MLSS concentration but rather increased with MLSS concentration over 1,000mg/l. This resulted from positive effect of interacted coagulation for floc formation by transfer to the zone of compressed settling when MLSS concentration increased over 1,000mg/l. The settling velocity of sludge interface showed $28.66{\times}10^{-3}/min$ for average settling velocity of sewage sludge which is 6.7 times higher than $4.25{\times}10^{-3}/min$ for average settling velocity of organic wastewater sludge. The increasing rate of CR for organic wastewater activated sludge was higher than that of settling velocity under 200mg/l of PAC dosage but settling velocity was higher than CR over 200mg/l of PAC dosage. However, in case of sewage sludge, the differential rate of CR was low when PAC dosage was increased but the settling velocity was suddenly increased with over 200mg/l dosage. Therefore coagulation effect was more efficient to MLSS settling velocity rather than SS removal effect in the supernatant.

  • PDF

The Aeration to Improve Manganese and Chloroform of Effluent at Sludge Thickener of the Conventional Water Treatment Plant (정수장 슬러지 폭기가 방류수 망간 및 클로로포름에 미치는 영향)

  • Choi, Ilgyung;Beak, Inho;Jeong, Chanwoo;Lee, Sungjin;Park, Jungwook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.2
    • /
    • pp.113-118
    • /
    • 2014
  • So many nationwide drinking water treatment plants are under much difficulties by new reinforced discharged effluent standards. Generally, the sludge at thickener should be retended for a long time during usual days. Sometime, the soluble manganese and chloroform may be formed under the anaerobic condition in the sludge thickener when the sludge retention time is longer with low turbidity. This phenomenon results in difficulties to keep regulatory level of the discharged effluent. It was necessary to improve the operation conditions and process itself in order to meet water quality standard recently reinforced. For an effort to overcome the problems, a sludge aeration was successfully implemented into the thickening process. Sludge aeration prevent particle oxidated Manganese eluting soluble de-oxidated Manganese, excrete formated Chloroform from effluent to air, and improve sludge settling through homogenized sludge particle. We aerated sludge at the conventional water treatment plant, measured Manganese and Chloroform of clarified water at upper sludge, and solid-fluid interface height of sludge in mass cylinder. As a result, contaminant's concentrations of the final effluent was much decreased : 41% of manganese, approximately 62% of chloroform and 35% of sludge volume, compared with non-aeration sludge.

Application of Anaerobic Sequencing Batch Reactor to Mesophilic Digestion of Municipal Sewage Sludge (중온 혐기성 연속회분식 공정에 의한 도시하수슬러지의 소화가능성 평가)

  • Hur, Joon-Moo;Chang, Duk;Chung, Tai-Hak;Son, Bo-Soon;Park, Jong-An
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.2
    • /
    • pp.9-19
    • /
    • 1998
  • Laboratory experiments were carried out to investigate the performance of anaerobic sequencing batch reactor(ASBR) for digestion of a municipal sludge. Each cycle of the ASBR comprised feeding, two-or three-day reaction, one-day thickening, and withdrawal. The reactors were operated at an HRT of 10days and 5days with an equivalent organic loading rate of 0.8-1.54 gVS/l/d, 1.81-3.56 gVS/l/d at 35$\circ$C, respectively. Solids accumulation was remarkable in the ASBR during start-up period, and directly affected by settleable solids in the feed sludge. Floatation thickening occured in the ASBRs, and Solids profiles at the end of thickening step dramatically changed at solid-liquid interface. Slight difference in solids concentrations was observed within thickened sludge bed. Efficiencies through floatation thickening were comparable to that of additional thickening of the completely mixed control reactor. Average solids concentrations in the ASBRs were 2.2-2.6 times higher than that in the control throughout the total operation period. The dehydrogenase activity had a strong correlation with the solids concentration. Organics removals based on clarified effluent of the ASBRs were consistently above 86%. Remarkable increase in equivalent gas production of 27-52% was observed at the ASBRs compared with the control though the control and ASBRs showed similiar effluent quality. Thus, digestion of a municipal sludge was possible using the ASBR in spite of high concentration of solids in the sludge.

  • PDF

Performances of Anaerobic Sequencing Batch Reactor for Digestion of Municipal Sludge at the Conditions of Critical Solid-liquid Separation (혐기성 연속 회분식 공정에 의한 도시하수슬러지 소화시 고액분리 특성에 따른 처리효율평가)

  • Hur, Joon-Moo;Park, Jong-An
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.77-85
    • /
    • 2002
  • The objective of this study was to evaluate the performances of the ASBR under critical conditions of solid-liquid separation, caused by extremely high solids concentration, for wider application of the ASBR to various wastes. The ASBRs and completely-mixed daily-fed control runs were operated using a municipal mixed sludge at 35$^{\circ}C$ and 55$^{\circ}C$. Conversion of completely-mixed daily-fed reactor to sequencing batch mode and changes in HRT of all ASBRs were easily achieved without adverse effect, regardless of digestion temperature. Solids accumulation was remarkable in the ASBRs, and directly affected by settleable solids concentration of the feed sludge. Noticeable difference in solids-liquid separation was that flotation thickening occurred in the mesophilic ASBRs, while gravity thickening was a predominant solid-liquid separation process in the thermophilic ASBRS. Solids profiles at the end of thickening step dramatically changed at solid-liquid interface, and slight difference in solids concentrations was observed within thickened sludge bed. Organics removals based on subnatant or supernatant after thickening always exceeded 80% in all reactors. Thickened sludge volume and gas production of the ASBRs affected mutually. Gas production increased as thickened sludge accumulated, and continuous gas evolution during thickening could cause thickened sludge to expand or resuspend. Thickened sludge volume exceeding a predetermined withdrawal level resulted in loss of organic solids as well as biomass during withdrawal step, leading to decrease in gas production ind SRT. Such an adverse mutual effect was significant in gravity thickening, while it was not sensitive in flotation thickening. Changes in organic loading had no significant effect on organic removals and gas production after build-up of solids in the ASBRs.

Evaluation of water treatment characteristics at the improved circle secondary settling basin (개량 고속원형침전지의 수처리 특성 평가)

  • Jang, Honggyu;Cho, Youngman;Kim, Changwon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.609-614
    • /
    • 2014
  • Researcher of this study improved conventional circle secondary settling basin, through the way such as extend of inlet pipe length, introduction of device for inducting uniforming of flow, keeping of height of sludge interface. Also, we compared conventional circle settling basin to improved circle settling basin the water treatment efficiency. Result of research, when SVI is average 117, improvement rate of SS and BOD were 51.0%, 37.0% approximately compared to conventional settling basin. And when SVI is average 178, improvement rate of SS and BOD were 22.7%, 36.0% approximately. Also when SVI is average 196, improvement rate of SS and BOD were 24.7%, 30.3% approximately. When it's winter, improvement rate of SS, BOD, COD, TN and TP were 20.6%, 17.9%, 13.9%, 13.5%, 12.4% approximately. Therefore, we can be the judge, this improved settling basin can be used as the final settling basin in the waste water treatment plant.

Development of the Underwater Cleaning Robot Platform for a Higher Efficiency (고효율 수중청소로봇 플랫폼 기술 개발)

  • Suh, Jin-Ho;Lee, Jung-Woo;Kim, Jong-Geol;Choi, Young-Ho;Choi, Il-Seop
    • Journal of Power System Engineering
    • /
    • v.21 no.3
    • /
    • pp.74-84
    • /
    • 2017
  • This paper presents the development of the underwater cleaning robot platform for a higher efficiency in manufacturing industry. Human operators directly go into the cistern and clean sludge after drainage of the water so far. It is sometimes dangerous because of the harmful chemical materials from the product making process. In addition, it takes long time for water drainage and supplying it back. However, the robot cleaning operation does not need to drain water so that it could be applied to the sludge cleaning work at any time without the plant pause. Moreover, it can prevent the safety accidents because human operators are not necessary to enter directly the sludge cisterns. This paper shows the performance of cleaning work that can be applied in the industrial field through the design and development of underwater cleaning robot platform. And these results demonstrate that the developed underwater cleaning robot has great possibilities to clean other industrial water cisterns.

Diagnostic Software for Wastewater Treatment Plant using Activated-Sludge Process (활성슬러지 폐수처리장 진단 소프트웨어)

  • 손건태;이재은
    • Journal of Environmental Science International
    • /
    • v.8 no.5
    • /
    • pp.611-616
    • /
    • 1999
  • The diagnostic software for the wastewater treatment plant using activated-sluge process is developed in order to increase the efficiency of management of the wastewater treatment plant. This software is based on the expert system and the visualized user interface, including the diagnosis of quantitative and qualitative data. For the generalization of this software, the initialization of each unit process and updating the files can be possible.

  • PDF