• 제목/요약/키워드: Slave

검색결과 694건 처리시간 0.032초

의료용 햅틱 마스터-슬레이브 로봇 시스템 : 실험적 성능 평가 (A Haptic Master-slave Robot System : Experimental Performance Evaluation for Medical Application)

  • 오종석;신원기;프엉박;엄창호;최승복
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.41-48
    • /
    • 2013
  • In this work, 4-DOF ER haptic master is proposed and integrated with a slave robot for minimally invasive surgery(MIS). Using a controllable ER fluid, the haptic master can generate a repulsive force/torque with the 4-DOF motion. For realization of master-slave robot system, the motion command of the haptic master is realized by slave surgery robot. In order to follow the 4-DOF motion of the haptic master, novel mechanism of slave surgery robot with gimbal joint is devised. Accordingly, the haptic master-slave robot system is established by incorporating the slave robot with the haptic master device in which the desired repulsive force/torque and position are transferred to each other via wireless communications. In order to obtain the desired force/torque and position trajectories, tracking controllers for haptic master and slave robot are designed and implemented, respectively. It has been demonstrated that the desired effective torque tracking control performance is well achieved using the proposed haptic master-slave robot system.

의료용 햅틱 마스터-슬레이브 로봇 시스템 : 실험적 성능 평가 (A Haptic Master-Slave Robot System : Experimental Performance Evaluation for Medical Application)

  • 오종석;신원기;프엉박;엄창호;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.421-427
    • /
    • 2012
  • In this work, 4 DOF ER haptic master is proposed and integrated with a slave robot for minimally invasive surgery (MIS). Using a controllable ER fluid, the haptic master can generate a repulsive force/torque with the 4-DOF motion. For realization of master-slave robot system, the motion command of the haptic master is realized by slave surgery robot. In order to follow the 4 DOF motion of the haptic master, novel mechanism of slave surgery robot with gimbal joint is devised. Accordingly, the haptic master-slave robot system is established by incorporating the slave robot with the haptic master device in which the desired repulsive force/torque and position are transferred to each other via wireless communications. In order to obtain the desired force/torque and position trajectories, tracking controllers for haptic master and slave robot are designed and implemented, respectively. It has been demonstrated that the desired effective torque tracking control performance is well achieved using the proposed haptic master-slave robot system.

  • PDF

Development of a Master-Slave System for Active Endoscope Using a Multi-DOF Ultrasonic Motor

  • Takemura, Kenjiro;Harada, Dai;Maeno, Takashi
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제4권1호
    • /
    • pp.17-22
    • /
    • 2002
  • Endoscopes for industrial and medical fields are expected to have multi degree-of-freedom (DOF) motions. A multi-DOF ultrasonic motor we developed consists of a spherical rotor and a bar-shaped stator, and the rotor rotates around three perpendicular axes using three natural vibration modes of the stator. In this study, a multi-DOF unilateral master-slave system for active endoscope using the multi-DOF ultrasonic motor is developed. The configurations of master and slave arms for active endoscope are similar, so that an operator can easily handle the master-slave system. First, driving characteristics of the multi-DOF ultrasonic motor are measured in order to design the slave arm and its controller. Next, the master arm and the slave arm are designed. Then, the unilateral feedback controller for the master-slave system is developed. Finally, the motion control tests of rotor are conducted. As a result, the possibility of the endoscope is confirmed.

고속 DIO(Digital I/O) 시스템의 설계와 제작 (Design and Implementation of a Fast DIO(Digital I/O) System)

  • 이종운;조규상
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권5호
    • /
    • pp.229-235
    • /
    • 2006
  • High speed PC-based DIO(Digital I/O) system that consists of a master device and slave I/O devices is developed. The PCI interfaced master device controls all of serial communications, reducing the load on the CPU to a minimum. The slave device is connected from the master device and another slave device is connected to the slave device, it can repeated to maximum 64 slave devices. The slave device has 3 types I/O mode, such as 16 bits input-only, 16 bits output-only, and 8bits input-output. The master device has 2 rings which can take 64 slaves each. Therefore, total I/O points covered by the master is 2048 points. The slave features 3 types of input/output function interchangeability by DIP switch settings. Library, application, and device driver software for the DIO system that have a secure and a convenient functionality are developed.

파이프라인 구조 연산회로를 위한 AMBA AXI Slave 설계 (Design of AMBA AX I Slave Unit for Pipelined Arithmetic Unit)

  • 최병윤
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 춘계학술대회
    • /
    • pp.712-713
    • /
    • 2011
  • 본 논문에서는 파이프라인 구조의 연산회로를 효율적으로 검증하기 위한 AMBA AXI Slave 하드웨어 구조를 제안하고, 설계 예로 파이프라인 곱셈기를 내장한 구조를 제시하였다. 제안한 AXI Slave 회로는 입출력 버퍼 블록 메모리, 제어용 레지스터, 파이프라인 구조 연산 회로, 파이프라인 제어회로, AXI 버스 슬레이브 인터페이스로 구성된다. 주요 동작 과정은 입력 버퍼 메모리와 외부 마스터 사이의 버스트 데이터 전송, 제어 레지스터에 동작 모드 설정, 입력 버퍼 메모리에 담긴 데이터에 대한 반복적인 파이프라인 연산회로 동작, 출력 버퍼 메모리에 담긴 출력 데이터와 외부 마스터 사이의 버스트 데이터 전송으로 나누어진다. 제안한 AXI slave 구조는 범용 인터페이스 구조를 갖고 있으므로 파이프라인 구조 구조의 연산회로를 내장한 AMBA AHB와 AXI slave에 응용이 가능하다.

  • PDF

범용 매스터 암을 이용한 원격 조작 시스템의 개발 (A development of a teleoperation system using an universal master arm)

  • 차동혁;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.343-347
    • /
    • 1992
  • In this paper, an unilateral teleoperation system using an universal master arm is developed. This system is composed of an universal master arm, a slave arm and a telerobot controller. The universal master arm has a vertically articulated type link structure, while an industrial robot is used as a slave arm. As the shapes of master arm and slave arm are different, the workspace mapping is needed, which maps the workspace of master arm to that of slave arm. Experimental results show that the slave arm of the developed system effectively follows the operator's motion.

  • PDF

Double-Frequency Jitter in Chain Master-Slave Clock Distribution Networks: Comparing Topologies

  • Piqueira Jose Roberto Castilho;Caligares Andrea Zaneti
    • Journal of Communications and Networks
    • /
    • 제8권1호
    • /
    • pp.8-12
    • /
    • 2006
  • Master-slave (M-S) strategies implemented with chain circuits are the main option in order to distribute clock signals along synchronous networks in several telecommunication and control applications. Here, we study the two types of masterslave chains: Without clock feedback, i.e., one-way master-slave (OWMS) and with clock feedback, i.e., two-way master-slave (TWMS) considering the slave nodes as second-order phase-locked loops (PLL) for several types of loop low-pass filters.

마스터-슬레이브 조작기의 위치추종-힘반영을 위한 제한 구조 슬라이딩모드 제어 (Constrained Structured Sliding Mode Control for Position Tracking-Force Reflection Control of Master-Slave Manipulator)

  • 강민식
    • 한국정밀공학회지
    • /
    • 제27권12호
    • /
    • pp.48-58
    • /
    • 2010
  • In this study, position tracking and force reflection control of a master-slave manipulator which will be used for handling objects contaminated by radioactivity has been addressed. Since available measurements concerning on dynamic motion of the master-slave manipulator are restricted, a simple constrained control structure was suggested. In the consideration of the uncertain dynamic behaviors of the slave manipulator which is dependent upon mass and shape of work pieces grasped and dynamic properties of the environment contacted, a simple structured sliding mode control was suggested to guarantee robustness with respect to parameter uncertainties and external disturbances. The proposed control was applied to a 1-DOF master-slave link system. The control performances were verified along with some computer simulation results.

실시간 운영체제 기반의 복강경 수술 로봇의 모터제어 시스템에 관한 연구 (A Study of a RealTime OS Based Motor Control System for Laparoscopic Surgery Robot)

  • 송승준;김용;최재순;배진용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.218-221
    • /
    • 2006
  • This paper reports on a Realtime OS based motor control system for laparoscopic surgery robot which enables telesurgery and overcomes shortcomings with conventional laparoscopic surgery. The system has a conventional master-slave robot configuration and the control system consists of joint controllers, host controllers, and power units. The robot features (1) a compact slave robot with 5 DOF (Degree Of Freedom) expanding the workspace of each tool and increasing the number of tools operating simultaneously, and (2) direct 1:1 correspondence in the joint of master and slave robot that simplifies control algorithm and enhances reliability. Each master, slave and GUI (Graphical User Interface) host has a dedicated RTOS (RealTime OS), RTLinux-Pro (FSMLabs Inc., U.S.A.) Each master and slave controller set pair has a dedicated CAN (Controller Area Network) channel for control and monitoring signal communication. Total 4 pairs of the master/slave manipulators as current are monitored by one host controller for operation monitoring and higher level motion control. The system showed acceptable performance in both position control precision and master-slave motion synchronization and is now under further development for better safety and control fidelity for clinically applicable prototype.

  • PDF

New slave-node constraints and element for adaptive analysis of C0 plates

  • Sze, K.Y.;Wu, D.
    • Structural Engineering and Mechanics
    • /
    • 제39권3호
    • /
    • pp.339-360
    • /
    • 2011
  • In the h-type adaptive analysis, when an element is refined or subdivided, new nodes are added. Among them are the transition nodes which are the corner nodes of the new elements formed by subdivision and, simultaneously, the mid-side nodes of the adjacent non-subdivided elements. To secure displacement compatibility, the slave-node approach in which the DOFs of a transition node are constrained by those of the adjacent nodes had been used. Alternatively, transition elements which possess the transition nodes as active mid-side/-face nodes can be used. For C0 plate analyses, the conventional slave-node constraints and the previously derived ANS transition elements are implemented. In both implementations, the four-node element is the ANS element. With reference to the predictions of the transition elements, the slave-node approach not only delivers erroneous results but also fails the patch test. In this paper, the patch test failure is resolved by developing a set of new constraints with which the slave-node approach surpasses the transition-element approach. The accuracy of the slave-node approach is further improved by developing a hybrid four-node element in which the assumed moment and shear force modes are in strict equilibrium.