• 제목/요약/키워드: Sitting Pressure

Search Result 143, Processing Time 0.021 seconds

A Study on the Prevalence and Risk Factors of Postprandial Hypotension among the Community-Dwelling Aged (재가 노인의 식사후 저혈압 발생에 관한 연구)

  • Yu Su-Jeong;Song Mi-Soon;Kim Hyun-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.9 no.3
    • /
    • pp.434-446
    • /
    • 2002
  • Purpose: This study was to identify the prevalence of postprandial hypotension and its related risk factors, and investigate the relationship between the related symptoms and the occurrence of postprandial hypotension. Method: The data were collected from the 22th of August, 2000 to 7th May, 2001. The participants were 74 aged over 60 in Seoul and Chungju, Korea. Blood pressure was taken in the sitting Position at 15mins, 30mins and 60mins after starting meals. Result: 1) The prevalence of postprandial hypotension was 12.2% at 15mins, 25.7% at 30mins, 25.7% at 60mins after starting meals. 2) There was no significant difference in a9e, but there was significant difference in basal systolic blood pressure between responders and nonresponders to postprandial hypotension over the three different times. 3) There was no significant relation between the occurrence of postprandial hypotension and its related symptoms over the three different times. Conclusion: Findings indicate that this study will contribute to develop an assessment protocol and nursing strategies to identify risk factors and to prevent postrprandial hypotension for the aged.

  • PDF

Real-time position monitoring system using pressure sensor (압력센서를 이용한 자세 모니터링 시스템)

  • Min, Se-Dong;Beak, Jin-Ok;Lee, Hea-Lim;Na, Ye-Ji;Wang, Chang-Won;Jung, Hwa-Young
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.01a
    • /
    • pp.139-142
    • /
    • 2014
  • 앉아서 생활하는 시간이 많은 현대인들에게 올바르게 앉는 자세는 매우 중요하다. 따라서 현대인들이 올바른 자세를 유지할 수 있도록 도와주는 자세 모니터링 시스템을 고안하게 되었다. 이 시스템의 주요 구성으로는 전원부와 계측부, 제어부, 통신부, 안드로이드기반 어플리케이션으로 나눌 수 있다. 전원부는 9V의 건전지 하나로 구성되어 있고, 2개의 레귤레이터를 통해 아날로그 회로(3.3V)와 MCU(5V)에 전원이 공급되어진다. 그리고 계측부는 6개의 압력센서를 이용하여 아날로그 값을 계측한다. 제어부와 통신부는 MCU 보드(MSP430 Launchpad)와 FB155BC Bluetooth Module로 구성되어 있고, 안드로이드기반 어플리케이션은 Bluetooth Module에서 받은 디지털 신호들을 스마트폰의 화면에 UI공정을 거쳐 디스플레이 한다. 본 연구는 잘못된 자세로 의자에 앉는 습관을 스마트폰의 화면을 통해 실시간으로 확인하고, 바른 자세로 앉을 수 있도록 하여 척추교정 및 척추질환 예방에 기여할 것으로 예상된다.

  • PDF

Characteristics of the Muscular Activities on the Feedback Control of Elbow Orthosis Using Pneumatic Rubber Artificial Muscle (공압 고무 인공근육을 장착한 주관절 보조기 피드백 제어 시 근력 특성)

  • Hong, Kyung-Ju;Kim, Kyung;Kwon, Tae-Kyu;Kim, Dong-Wook;Kim, Nam-Gyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.725-728
    • /
    • 2008
  • An elbow orthosis with a pneumatic rubber actuator has been developed to assist and enhance upper limbs movements and has been examined for the effectiveness. The effectiveness of the elbow orthosis was examined by comparing muscular activities during alternate dumbbell curl motion wearing and not wearing the orthosis. The subjects participated in the experiment were younger adults in their twenties. The subjects were instructed to perform dumbbell curl motion in a sitting position wearing and not wearing orthosis in turn and a dynamometer was used to measure elbow joint torque outputs in an isokinetic mode. Orthosis was controlled using contractile muscle force that is measured from force sensor through cDAQ-9172 board. The air pressure of the pneumatic actuator was 0.3MPa the most suitable air pressure. For the analysis of muscular activities, Electromyography of the subjects was measured during alternate dumbbell curl motion. The experiment results showed that the muscular activities wearing the elbow orthosis were reduced. With this, we confirmed the effectiveness of the developed elbow orthosis.

Analysis of the Impact of Chair Tilt Function on Users' Biometric Signals and Comfort (의자의 틸트 기능이 사용자의 생체 신호 및 안락도에 미치는 영향 분석)

  • Seulki Kyeong
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.2
    • /
    • pp.75-80
    • /
    • 2024
  • This research investigates the influence of chair tilt functionality on biometric signals and user comfort, addressing the ergonomic challenges posed by modern sedentary lifestyles. Through an experimental study involving eight male participants, the impact of chair tilt on electromyography (EMG), heart rate, metabolic rate, pressure distribution, and distance between the lumbar spine and the lumbar support part of the chair was measured across different seating postures. The study utilized chairs with both synchronous and non-synchronous tilt mechanisms to explore how adjustments in chair design affect user comfort and physiological responses during prolonged sitting. Key findings suggest that chair tilt functionality can significantly reduce muscle activity and energy expenditure, enhancing user comfort and potentially mitigating health risks associated with prolonged sedentary behavior. Notably, the study revealed a preference among participants for chairs that aligned the rotational center of the tilt with the hip joint, highlighting the importance of this ergonomic feature in enhancing user comfort. Additionally, the research proposes a novel methodology for assessing seating comfort through the analysis of both biometric and physical signals, providing valuable insights for the development of ergonomic chair designs focused on user health and comfort.

Satisfaction and Experience of Side Effecting in Wearing Skinny Jeans (스키니 진의 착용 만족도 및 부작용 경험)

  • Park, Younghee
    • Journal of Fashion Business
    • /
    • v.22 no.2
    • /
    • pp.74-87
    • /
    • 2018
  • Many people who wear skinny jeans have expressed satisfaction or concern regarding the side effects of wearing the garments, based on specific demographic characteristics. For this study, we disseminated 373 copies of a questionnaire. Study subjects were eighteen-to fifty-nine-year-old man and women Linear regression was used for data analysis. Descriptive statistics included the ${\chi}^2$ test, t-test, ANOVA and Duncan multiple range test. Corresponding results in terms of difference analysis overall were significant when based on gender, marital status, age, occupation and the average score of satisfaction. The values were approximately three points. The qualitative results of difference analysis for side effects in wearing skinny jeans according to demographic characteristics were identified as the experience of displeasure by pressure. There was a significant difference according to gender. Leg edema was also observed based on gender, marital status, age, occupation and the experience of poor circulation of blood. The factor that has the greatest influence on satisfaction on wearing skinny jeans was sitting long hours.

Step Counts and Posture Monitoring System using Insole Type Textile Capacitive Pressure Sensor for Smart Gait Analysis (깔창 형태의 전기용량성 섬유압력센서를 이용한 보행 횟수 검출 및 자세 모니터링 시스템)

  • Min, Se-Dong;Kwon, Chun-Ki
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.8
    • /
    • pp.107-114
    • /
    • 2012
  • We have developed a textile capacitive pressure sensor for smart gait analysis. The proposed system can convert sensor signal into step counts and pressure levels by different posture. To evaluate the performance of insole type textile capacitive sensor, we measured capacitance change by increment of weights from 10 kg to 100 kg with 10 kg increment using M1 class rectangular weights (four 20 kg weights and two 10 kg weights) which have ${\pm}10%$ tolerance. The result showed non-linearity characteristic of a general capacitive pressure sensor. The test was performed according to a test protocol for four different postures (sitting, standing, standing on a left leg and standing on a right leg) and different walking speeds (1 km/h and 4 km/h). Five healthy male subjects were participated in each test. As we expected, the pressure level was changed by pressure distribution according to posture. Also, developed textile pressure sensor showed higher recognition rate (average 98.06 %) than commercial pedometer at all walking speed. Therefore, the proposed step counts and posture monitoring system using conductive textile capacitive pressure sensor proved to be a reliable and useful tool for monitoring gait parameters.

Analysis of Influencing Factors on Strength Characteristics of Cemented Sand (고결모래의 강도특성에 대한 영향요인 분석)

  • Lee, Moon-Joo;Choi, Sung-Kun;Choo, Hyun-Wook;Cho, Yong-Soon;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.12
    • /
    • pp.75-82
    • /
    • 2007
  • The effects of sitting pressure(${\sigma_{sit}}'$) during cementation, relative density and particle characteristics on the cohesion intercept due to cementation bonds and the confining stress inducing the breakage of cementation bonds ${p_i}'_{(BP)}$ are investigated from drained shear tests on the cemented sands confined under the isotropic stress up to 400 kPa. It was observed from the experimental results that the cemented sands, with the same density and gypsum content, show similar values of cohesion intercept and ${p_i}'_{(BP)}$, regardless of ${\sigma_{sit}}'$. Although the cohesion intercept and ${p_i}'_{(BP)}$ of cemented sands are observed to increase with increasing relative density and cementation level, the relative density appears to have more significant effect on ${p_i}'_{(BP)}$ than the cohesion intercept does. From analysing the test results of three different sands, it is shown that the smaller the particle size the larger the cohesion intercept and ${p_i}'_{(BP)}$, due to the increased number of contact points between the particles.

Ischial Pressure Sore Reconstruction Using Inferior Gluteal Artery Perforator Flap (아래볼기동맥 관통가지피판을 이용한 궁둥 욕창의 치료)

  • Kim, Young Seok;Kang, Jong Wha;Lee, Won Jai;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.209-216
    • /
    • 2007
  • Purpose: The ischial area is by far the most common site of pressure sores found in wheel chair bound paraplegic patients, because greatest pressure is exerted from the body on this area in a sitting position. Even after a series of successful pressure sore treatments, the site is very prone to relapse by the simplest ordinary tasks of everyday life. Therefore, it is crucial to preserve the main pedicle during primary surgery. Various surgical procedures employed to treat pressure sores such as myocutaneous flap and perforator flap have been introduced. After introduction of ischial sore treatment using the inferior gluteal artery perforator (IGAP) has been made, the authors experienced favorable clinical results of patients who have undergone IGAP flap procedure in a three year time period. Methods: A total of 17 patients received IGAP flap surgery in our hospital from January 2003 to May 2006, among which 14 of them being males and 3 females. Surgery was performed on the same site again in 6(35%) patients who had originally relapsed after receiving the conventional method of pressure sore surgery. Patients' average age was 49.4(27-71) years old. Most of the patients were paraplegic(11 cases, 65%) and others were either quadriplegic(4 cases, 23%) or ambulatory(2 cases, 12%). Based on hospital records and clinical photographs, we have attempted to assess the feasibility and practicability of the IGAP flap procedure through comparative analysis of several parameters: size of defective area, treatment modalities, occurrence of relapses, complications, and postoperative treatments. Results: The average follow-up duration of 17 subjects was 25.4 months(5-42 months). All flaps survived without any necrosis. Six cases were relapsed cases from conventional surgical procedures. All of them healed well during our follow-up study. Postoperative complications such as wound dehiscence and fistula developed in some subjects, but all were well healed through secondary treatment. A total of 2 cases relapsed after surgery. Conclusion: The inferior gluteal artery perforator flap is an effective method that can be primarily applied in replacement to the conventional ischial pressure sore reconstructive surgery owing to its many advantages: ability to preserve peripheral muscle tissue, numerous possible flap designs, relatively good durability, and the low donor site morbidity rate.

Machine-Learning based Smart Seat for Correction of Driver's Posture while Driving (기계학습 기반의 주행중 운전자 자세교정을 위한 지능형 시트)

  • Park, Heum;Lee, Changbum
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.4
    • /
    • pp.81-90
    • /
    • 2017
  • This paper presents a smart seat for correction of driver posture while driving. We introduce good postures with seat height, seat angle, head height, back of knees, distances of foot pedals, tilt of seat, etc. There have been some studies on correction of good posture while driving, effects of driving environment on driver's posture, sitting strategies based on seating pressure distribution, estimation of driver's standard postures, and others. However, there are a few studies on guide of good postures while driving for problem of driver's posture using machine leaning. Therefore, we suggest a smart seat for correction of driver's posture based on machine leaning, 1) developed the system to get postures by 10 piezoelectric effect element, 2) collect piezoelectric values from 37 drivers and 28 types of cars, 3) suggest 4 types of good postures while driving, 4) analyze test postures by kNN. As the results, we can guide good postures for bad or problems of postures while driving.

A Study on the Improving Speech Intelligibility of Sound Reinforcement System in Reverberant Rooms (잔향이 많은 공간에서 음향 시스템의 명료도 향상에 관한 연구)

  • Kang, Seong-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.8
    • /
    • pp.468-473
    • /
    • 2011
  • Speech may not be clearly understandable in the room that is highly reverberant, due to the loss of consonants intelligibility. Therefore, it is very important to obtain a high sound pressure level of direct sound in reverberant room. A properly designed sound reinforcement system can not provide the good speech intelligibility without the absorption treatments of walls. With using the highly directional speaker, we can transmit the sound energy into only the areas where people are sitting. This can be help to improve the speech intelligibility. In this paper, even in reverberant rooms, it will be shown that the good speech intelligibility can be obtained by only the directivity control of speaker without the room treatment. Also, it would be more improved by the properly room tuning using an equalizer.