• 제목/요약/키워드: Single-cell Measurement

검색결과 115건 처리시간 0.028초

Detection of Unbalanced Voltage Cells in Series-connected Lithium-ion Batteries Using Single-frequency Electrochemical Impedance Spectroscopy

  • Togasaki, Norihiro;Yokoshima, Tokihiko;Oguma, Yasumasa;Osaka, Tetsuya
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권4호
    • /
    • pp.415-423
    • /
    • 2021
  • For a battery module where single cells are connected in series, the single cells should each have a similar state of charge (SOC) to prevent them from being exposed to an overcharge or over-discharge during charge-discharge cycling. To detect the existence of unbalanced SOC cells in a battery module, we propose a simple measurement method using a single-frequency response of electrochemical impedance spectroscopy (EIS). For a commercially available graphite/nickel-cobalt-aluminum-oxide lithium-ion cell, the cell impedance increases significantly below SOC20%, while the impedance in the medium SOC region (SOC20%-SOC80%) remains low with only minor changes. This impedance behavior is mostly due to the elementary processes of cathode reactions in the cell. Among the impedance values (Z, Z', Z"), the imaginary component of Z" regarding cathode reactions changes heavily as a function of SOC, in particular, when the EIS measurement is performed around 0.1 Hz. Thanks to the significant difference in the time constant of cathode reactions between ≤SOC10% and ≥SOC20%, a single-frequency EIS measurement enlarges the difference in impedance between balanced and unbalanced cells in the module and facilitates an ~80% improvement in the detection signal compared to results with conventional EIS measurements.

ALU를 위한 단자속 양자 D2 Cell과 Inverter의 설계 (Design of Single Flux Quantum D2 Cell and Inverter for ALU)

  • 정구락;박종혁;임해용;강준희;한택상
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.140-142
    • /
    • 2003
  • We have designed a SFQ (Single Flux Quantum) D2 Cell and Inverter(NOT) for a superconducting ALU (Arithmetic Logic Unit). To optimize the circuit, we have used Julia, XIC and Lmeter for simulations and layouts. We obtained the circuit margin of larger than $\pm$25%. After layout, we drew chip for fabrication of SFQ D2 Cell and Inverter. We connected D2 Cell and Inverter to jtl, DC/SFQ, SFQ/DC and RS flip-flop for measurement.

  • PDF

다수의 계수구역간의 검사체적을 이용한 소형 세포농도센서 (Micro Cell Counter Using a Fixed Control Volume Between Double Electrical Sensing Zones)

  • 이동우;이소연;조영호
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1615-1620
    • /
    • 2005
  • We present a novel flow-rate independent cell counter using a fixed control volume between double electrical sensing zones. The previous device based on the single electrical cell sensing in a given flow-rate requires an accurate fluid volume measurement or precision flow rate control. The present cell counter, however, offers the flow-rate independent method for the cell concentration measurement with counting cells in a fixed control volume of $22.9{\pm}0.98{\mu}{\ell}$. In the experimental study, using the RBC (Red Blood Cell), we have compared the measured RBC concentrations from the fabricated devices with those from Hemacytometer. The previous and present devices show the maximum errors of $20.3\%\;and\;16.1\%$, which are in the measurement error range of Hemacytometer (about $20\%$). The present device also shows the flow-rate independent performance at the constant flow-rates ($5{\mu}{\ell}/min$ and $10{\mu}{\ell}/min$) and the varying flow-rate (4, 2, and $4{\mu}{\ell}/min$). Therefore, we demonstrate that the present cell counter is a simple and automated method for the cell concentration measurement without requiring an accurate fluid measurement and precision flow-rate control.

Performance Evaluation of Platinum Dispersed Self-humidifying Polymer Electrolyte Membrane Prepared by Using RF Magnetron Sputter

  • Kwak, Sang-Hee;Yang, Tae-Hyun;Kim, Chang-Soo;Yoon, Ki-Hyun
    • 한국세라믹학회지
    • /
    • 제40권2호
    • /
    • pp.118-122
    • /
    • 2003
  • The performance evaluation on Pt loading in the self-humidifying polymer electrolyte membrane for Polymer Electrolyte Mem-Brane Fuel Cell(PEMFC) was investigated by using single cell test and measurement of membrane resistance. The self-humidifying membrane comprised two membranes made of perfluorosulfonylfluroride copolymer resin and fine Pt particles tying between them, coated by sputtering. From the results of performance characteristics of self-humidifying membrane cell with different Pt loading, a single cell using self-humidifying membrane with 0.15 mg/$\textrm{cm}^2$ Pt loading showed better performance than that with the others over entire current density. Also, a single cell with 0.15 mg/$\textrm{cm}^2$ Pt loading had a lower resistance value than the other cells under externally nonhumidifying condition. It is indicated that the water produced in the membrane cell with 0.15 mg/$\textrm{cm}^2$ Pt loading showed a higher provision to maintain ionic conductivity of the membrane than the other cells. The optimum amount of Pt particles embedded in the membrane for self-humidifying PEMFC was determined to be about 0.15 mg/$\textrm{cm}^2$.

Ag 집전체를 적용한 평판형 SOFC 단전지 (Single Cell Stacked Planar Type SOFC Assembled Using a Ag-Current Collector)

  • 조남웅;황순철;이인성
    • 한국세라믹학회지
    • /
    • 제44권12호
    • /
    • pp.720-726
    • /
    • 2007
  • Current collectors of SOFC play a significant role on the performance of power generation. In this study a single cell stacked SOFC was assembled using Ag-mesh as a cathode current collector, and evaluated its performance. No gas leakages of the single cell stack occurred in the tests of gas detection and OCV measurement. The OCV and initial power of the stack were 1.09V and $0.45W/cm^2$, respectively, under the flow rates of air at 2,500 cc/min and $H_2$ at 1,000 cc/min at the test temperature of $750^{\circ}C$. A degradation rate of 44.0% was measured during the prolonged time of 307 h. The relatively low durability of the tested single cell stack was found to be the evaporation of Ag-mesh at the current corrector.

수퍼 샘플링과 보간을 이용한 생물조직 영상의 면적 측정 (Area Measurement of Organism Image using Super Sampling and Interpolation)

  • 최선완;유숙현
    • 한국멀티미디어학회논문지
    • /
    • 제17권10호
    • /
    • pp.1150-1159
    • /
    • 2014
  • This paper proposes a method for extracting tissue cells from an organism image by an electron microscope and getting the whole cell number and the area from the cell. In general, the difference between the cell color and the background is used to extract tissue cell. However, there may be a problem when overlapped cells are seen as a single cell. To solve the problem, we split them by using cell size and curvature. This method has a 99% accuracy rate. To measure the cell area, we compute two areas, the inside and boundary of the cell. The inside is simply calculated by the number of pixels. The cell boundary is obtained by applying super sampling, linear interpolation, and cubic spline interpolation. It improves the error rate, 18%, 19%, and 120% respectively, in comparison to the counting method that counts a pixel area as 1.

분광기를 이용한 반사형 TN LCD의 셀갭 측정 (Cell gap measurement method far single-polarizer reflective liquid crystal cells)

  • 이기동;박경호;이서헌;윤태훈;김재창
    • 한국광학회지
    • /
    • 제12권6호
    • /
    • pp.468-471
    • /
    • 2001
  • 본 논문에서는 회전 편광자법을 이용한 액정셀의 셀갭측정 방법을 개선하여 반사모드의 TN LCD의 셀갭을 측정할 수 있는 방법을 제안하였다. 측정 시스템에서 액정셀(liquid crystal cell)을 회전시키며 분산 특성을 측정하여, 액정 꼬임각이 알려진 셀의 갭과 파장에 따른 Δnd값을 구할 수 있다.

  • PDF

임피던스 측정법을 이용한 단결정태양전지의 성능 특성 분석 (Performance Analysis of Single Crystal Solar Cell by Impedance Measurement)

  • 정유라;최용성;황종선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.202-202
    • /
    • 2010
  • This study focused on the characteristics of single crystal solar cell using the impedance technique. In this experiment, the impedance was measured according to frequency's from 1mHz until 2MHz. The solar cell is R-L-C series circuit. Capacitance reactance was changed according to changing from low frequency to high frequency. It could know that the impedance was changed according to the frequency increases in solar cell.

  • PDF

연골세포의 기계적 물성치 측정 (Measurement of Biomechanical Property of Chondrocyte)

  • 이권용;;박상국;김병수;박종철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.154-157
    • /
    • 2002
  • A cyto-indentation technique was used to obtain the biomechanical compressive compliance property of an chondrocyte cell attached to glass surface, which was tried to generate joint cartilage by tissue engineering. Piezo-transducer system and dual photo-diode system were used to conduct mechanical indentation through displacement-controlled testing and the measurement of corresponding cell reaction force. The Poisson's ratio of 0.37 was quoted from other report. The compressive compliance of chondrocyte, that was determined by elastic contact theory, was 1.38${\pm}$0.057 kPa. This value is 30% higher than that of MG63 osteoblast-like cell. The cyto-indentation technique employed in this study is so precise that it can quantify the biomechanical property of single cell.

  • PDF