• 제목/요약/키워드: Single domain

검색결과 1,087건 처리시간 0.029초

External Field Dependence of $Fe^57$ NMR in Pure Iron

  • Dho, Joongheo;Kim, Mincheol;Lee, Soonchil;Lee, Wonjong;Kim, Yoonbae
    • Journal of Magnetics
    • /
    • 제1권1호
    • /
    • pp.14-18
    • /
    • 1996
  • The NMR spin echo in pure iron was measured as a function of external magnetic field up to 10 kgauss at room temperature. We observed the signal coming from a single domain formed over 7.5 kgauss which has not been detected in previous works. The resonance frequency shift with external field confirmed that the hyperfine field in iron is -330.2 kgauss. From the comparison of the magnetization curve with the domain wall signal and the resonance frequency in external field, we showed that NMR could give the useful qualitative information on the magnetization process. The extent of the internal strain removed by annealing, which can be hardly seen in hysteresis curves, was clearly shown up in the NMR line-width.

  • PDF

Mixed-Domain Adaptive Blind Correction of High-Resolution Time-Interleaved ADCs

  • Seo, Munkyo;Nam, Eunsoo;Rodwell, Mark
    • ETRI Journal
    • /
    • 제36권6호
    • /
    • pp.894-904
    • /
    • 2014
  • Blind mismatch correction of time-interleaved analog-to-digital converters (TI-ADC) is a challenging task. We present a practical blind calibration technique for low-computation, low-complexity, and high-resolution applications. Its key features are: dramatically reduced computation; simple hardware; guaranteed parameter convergence with an arbitrary number of TI-ADC channels and most real-life input signals, with no bandwidth limitation; multiple Nyquist zone operation; and mixed-domain error correction. The proposed technique is experimentally verified by an M = 4 400 MSPS TI-ADC system. In a single-tone test, the proposed practical blind calibration technique suppressed mismatch spurs by 70 dB to 90 dB below the signal tone across the first two Nyquist zones (10 MHz to 390 MHz). A wideband signal test also confirms the proposed technique.

Conceptual design of buildings subjected to wind load by using topology optimization

  • Tang, Jiwu;Xie, Yi Min;Felicetti, Peter
    • Wind and Structures
    • /
    • 제18권1호
    • /
    • pp.21-35
    • /
    • 2014
  • The latest developments in topology optimization are integrated with Computational Fluid Dynamics (CFD) for the conceptual design of building structures. The wind load on a building is simulated using CFD, and the structural response of the building is obtained from finite element analysis under the wind load obtained. Multiple wind directions are simulated within a single fluid domain by simply expanding the simulation domain. The bi-directional evolutionary structural optimization (BESO) algorithm with a scheme of material interpolation is extended for an automatic building topology optimization considering multiple wind loading cases. The proposed approach is demonstrated by a series of examples of optimum topology design of perimeter bracing systems of high-rise building structures.

정압 스러스트 베어링의 유체-구조물 사이의 상호작용에 관한 연구 (A Study on Fluid-Structure Interaction of a Hydrostatic Thrust Bearing)

  • 김병탁
    • 한국기계가공학회지
    • /
    • 제5권3호
    • /
    • pp.92-98
    • /
    • 2006
  • In this study, the behavior characteristics of a hydrostatic thrust bearing used in hydraulic equipment was analyzed using a commercial finite element program, ADINA. The solid domain was modeled with the fluid domain simultaneously to solve the fully coupled problem, because this is a problem where a fully coupled analysis is needed in order to model the fluid-structure interaction(FSI). The results such as bearing deformation, stress, film thickness and lifting bearing force were obtained through FSI analysis, and then they were compared with the results calculated from the classical method, a single step sequential analysis. It was found that the result difference between two analyses was increased according to the injection pressure. Therefore, in case of high pressure loading, it is desirable to conduct the FSI analysis to examine the deformation characteristics of a hydrostatic slipper bearing.

  • PDF

시간 영역 유한 차분법을 이용한 마이크로스트립 구조의 풀-웨이브 해석 (Full-Wave Analysis of Microstrip Structures by Time-Domain Finite Difference (TDFD) Method)

  • 김동욱;홍성철;이기로
    • 전자공학회논문지A
    • /
    • 제29A권7호
    • /
    • pp.31-38
    • /
    • 1992
  • In this paper, numerical analysis package using Time-Domain Finite Difference (TDFD) method is developed to solve the initial value problem of Maxwell's equation and applied to several microstrip structures. TDFD allows us to show graphically the evolution of the crosswalk between microstrip lines. Moreover, we can obtain transmission line parameters and scattering parameters through Fourier transform of TDFD results in easy and efficient ways. TDFD is successfully applied to :1) wide band electromagnetic wave propagation along the single microstrip line, 2) crosswalk analysis between two microstrip lines, and 3) three metal line side-coupled filter. Our results show much better agreement with other theoretical experimental results reported in the literature. Thus we expect that TDFD is very useful to designing MMIC(Monolithic Microwave Integrated Circuit).

  • PDF

Microwave Dielectric Characterization of Binary Mixtures of 3-Nitrotoluene with Dimethylacetamide, Dimethylformamide and Dimethylsulphoxide

  • Chaudhari, Ajay;Chaudhari, H.C.;Mehrotra, S.C.
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권9호
    • /
    • pp.1403-1407
    • /
    • 2004
  • Dielectric relaxation measurements on 3-nitrotoluene (3-NT) mixture of dimethylacetamide (DMA), dimethylformamide (DMF) and dimethysulphoxide (DMSO) have been carried out across the entire concentration range using Time domain reflectometry technique at 15, 25, 35 and $45^{\circ}C$ over the frequency range from 10 MHz to 20 GHz. For all the mixtures, only one dielectric loss peak was observed in this frequency range and the relaxation in these mixtures can be well described by a single relaxation time using Debye model. Bilinear calibration method is used to obtain complex permittivity ${\varepsilon}^{*}({\omega})$ from complex reflection coefficient ${\rho}^{*}({\omega})$ over frequency range 10 MHz to 20 GHz. The excess permittivity, excess inverse relaxation time, Kirkwood correlation factor, molar energy of activation are also calculated for these mixtures to study the solute-solvent interaction.

Micromagnetic Modeling of Spin-valve MR Head with Synthetic Antiferromagnet (SyAF)

  • Tahk, Y.W;Lee, K.J;Lee, T.D
    • Journal of Magnetics
    • /
    • 제7권2호
    • /
    • pp.55-58
    • /
    • 2002
  • MR transfer behaviors of the permanent magnet biased spin valve MR sensors with SyAF (synthetic antiferromagnet) layers were studied by micromagnetics modeling. For narrow track MR heads, various height to width ratios were considered together with strength of permanent magnets which stabilities the free layed As the MR sensor width is reduced to $0.12 \mu{m}$, sensor height less than 0.09 ${\mu}{\textrm}{m}$ is needed to show good linearity and the Mr.t of permanent magnets smaller than 0.2 memu/$cm^2$ is sufficient for the domain stabilization. The conditions for single domain behavior of the free layer were also investigated through optimizing the biasing strength of permanent magneto the shield gap and the aspect ratio of MR sensor.

GPR 및 단일채널 탄성파탐사에 의한 터널라이닝 배면공동 조사 (Detection of the Cavity Behind the Tunnel Lining by Single Channel Seismic and GPR Method)

  • 신성렬;조철현;신창수;양승진;장원일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권4호
    • /
    • pp.148-158
    • /
    • 1998
  • Determining the thickness if concrete lining and detecting of the cavity where is located behind tunnel lining plays an important role in the safety diagnosis of tunnel structure and the quality control. In this study, we made use of GPR and seismic method in order to find the cavity or flaw. Although GPR is very useful method in the concrete lining without rebar, it is difficult to detect the cavity in the reinforced concrete lining. We applied mini-seismic method to the reinforced concrete lining. The obtained seismic data was processed by means of seismic section in time domain and image section of power spectrum in frequency domain using Impact-Echo method as well. The proposed method can accurately show the location and depth of the cavity in the reinforced concrete lining.

  • PDF

내진실험 연구를 위한 다지점 가진 지동대의 활용 (Applications of Seismic Test using Multi-platform Shaking Table System)

  • 최형석;김남식;정진환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.126-131
    • /
    • 2013
  • As the testing instrument for seismic research, the multi-platform shaking table system of SESTEC in the Pusan National University was introduced to suggest the multi-support shaking table testing methods and also to investigate its ability and applicability. 2 spans single-pylon cable-stayed bridge model, 3 spans girder bridge model and nuclear piping system model are presented and the acceleration and displacement table feedbacks of the each tests are compared to verify the simultaneous excitation ability in time domain and frequency domain.

  • PDF

Color Domain 및 Gamma Correction 적용에 따른 Retinex 기반 영상개선 알고리즘의 효과 분석 (Performance Analysis of Retinex-based Image Enhancement According to Color Domain and Gamma Correction Adaptation)

  • 김동형
    • 디지털산업정보학회논문지
    • /
    • 제15권1호
    • /
    • pp.99-107
    • /
    • 2019
  • Retinex-based image enhancement is a technique that utilizes the property that the human visual characteristics are sensitive to the difference from the surrounding pixel value rather than the pixel value itself. These Retinex-based algorithms show different characteristics of the improved image depending on the applied color space or gamma correction. In this paper, we set eight different experimental conditions according to the application of color space and gamma correction, and analyze the objective and subjective performance of each Retinex based image enhancement algorithm and apply it to the implementation of Retinex based algorithm. In the case of gamma correction, quantitative low entropy images and low contrast images are obtained. The application of Retinex technique in HSI color space rather than RGB color space is found to be high in overall subjective image quality as well as maintaining color.