• 제목/요약/키워드: Single and Double

검색결과 2,717건 처리시간 0.031초

와이블 고장모형 하에서의 이중샘플링 T2 관리도의 경제적-통계적 설계 (이중샘플링 T2 관리도의 경제적-통계적 설계) (Economic-Statistical Design of Double Sampling T2 Control Chart under Weibull Failure Model)

  • 홍성옥;이민구;이주호
    • 품질경영학회지
    • /
    • 제43권4호
    • /
    • pp.471-488
    • /
    • 2015
  • Purpose: Double sampling $T^2$ chart is a useful tool for detecting a relatively small shift in process mean when the process is controlled by multiple variables. This paper finds the optimal design of the double sampling $T^2$ chart in both economical and statistical sense under Weibull failure model. Methods: The expected cost function is mathematically derived using recursive equation approach. The optimal designs are found using a genetic algorithm for numerical examples and compared to those of single sampling $T^2$ chart. Sensitivity analysis is performed to see the parameter effects. Results: The proposed design outperforms the optimal design of the single sampling $T^2$ chart in terms of the expected cost per unit time and Type-I error rate for all the numerical examples considered. Conclusion: Double sampling $T^2$ chart can be designed to satisfy both economic and statistical requirements under Weibull failure model and the resulting design is better than the single sampling counterpart.

이중 분사 적용에 따른 단기통 디젤엔진의 연소특성에 관한 연구 (Study on Combustion Characteristics of Single-Cylinder Diesel Engine by Double Injection)

  • 이종태;신달호;김형준;윤창완;김정수;박수한
    • 한국연소학회지
    • /
    • 제22권1호
    • /
    • pp.1-7
    • /
    • 2017
  • This paper presents an experimental study on the effect of double injection strategies on combustion characteristics in a single-cylinder diesel engine. These studies are applied to the double injection strategies, such as $2^{nd}$ injection timing variations with fixed injection interval (8 degree) and variations of injection pressures with fixed injection timing and intervals. The injection quantity was 7 + 7 mg for double injections, and 14 mg for single injection. When the injection pressure was increased, the ignition delay was shortened, and the ISFC (indicated specific fuel consumption) was increased due to the fast termination of combustion by the shortened energizing duration. In addition, the retardation of injection timings toward TDC (top dead center) caused the reduction of ignition delay and the decrease of ISFC with the decrease of FMEP (friction mean effective pressure).

단상 인버터의 동작에 의한 이중접속 3상 전압원 인버터의 출력파형 개선 (Output Waveform Improvement of Double-Connected 3-Phase Voltage Source Inverter by Single-Phase Inverter)

  • 최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.330-334
    • /
    • 2000
  • This paper proposes a new double-connected 3-phase voltage source inverter with improved output voltage waveform. An auxiliary single-phase inverter injects a ripple voltage into the double- connected inverter to convert 12-step operation to 36-step operation. The KVA rating of the output phase-shifting transformer is reduced by employing a harmonic canceling reactor. The whole rectifier-inverter system including the proposed technique is introduced and the experimental results are provided.

  • PDF

로우터리 경운(耕耘)시스템이 소요동력(所要動力)에 미치는 영향(影響) (Effects of Rotary Tilling Systems on Power Requirement)

  • 김성래;장동일;권순구;안영호
    • Journal of Biosystems Engineering
    • /
    • 제9권2호
    • /
    • pp.37-47
    • /
    • 1984
  • Using the soil bin systems, this study was carried out to analyze the effects of the angular and tilling speed of the rotary shaft with the edge curves which were $30^{\circ}$ and $40^{\circ}$, and the edged blade which were single and double, on the torque requirement of rotary tillage. In the analyses, we developed the mathematical models for the torque requirments of rotary tillage, and analyzed the optimum conditions of each variable for the minimum tillage torque requriements. The results of the study were summarized as follows. 1. The required tilling torque by one rotary blade has the minimum value when the tilling speed of the rotary blade was low, and the revolution of the rotary blade was fast, in general. 2. The torque requirements of single edged blade was decreased to about 81% in comparing with that of double edged blade of which the edge curved angle was $40^{\circ}$ and the tilling speed was 29.40 cm/sec. But, for the mean values, the maximum torque requirements were decreased to 45%, and the mean torque requirements were decreased to 35%. 3. For the edge curved angle, the torque requirements of ${\theta}=40^{\circ}$ were 48% more than that of ${\theta}=30^{\circ}$ in the maximum tilling torque in case that the rotary blade were double edged blade. but, there was not a difference when the rotary blades were single edged blade. The mean tilling torques of ${\theta}=40^{\circ}$ were 6% more when the rotary blade was double edged blade, and were 11% less at single edged blade, than that of ${\theta}=30^{\circ}$. 4. In order to reduce the torque requirements for tilling, the optimum revolutions of the rotary shaft were analyzed as that 204-240 rpm for the double edged blade and 280-320 rpm for the single edged blade.

  • PDF

프레스 단동로봇의 개발 (A Development of Single Action Press Robot)

  • 허성창;황병복
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1997년도 춘계학술대회논문집
    • /
    • pp.261-264
    • /
    • 1997
  • A single action press robot, which consists of a driving unit, rotator, up-down feed base and feed bar, is developed and applied for the press automation. The driving unit is made up with a face cam and blade cam, which have a phase angle. The feeding system consists of a double speed-up apparatus and linear motion guides, and has a fast motion characteristics. A horizontal feeding speed of the feed bar is increased twice by the double speed-up apparatus. The driving mechanism could be simplified due to the speed-up of the feeding unit.

  • PDF

일중효용 사이클과 일중효용/2단승온 사이클을 이용한 태양열 흡수식 냉방시스템의 비교 (Comparison Between Two Solar Absorption Cooling System Using Single Effect and Single Effect/Double Lift Cycle)

  • 정시영;이상수;조광운;백남춘
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.267-276
    • /
    • 2000
  • A numerical study has been carried out to find out the optimal design condition of a solar absorption cooling system. The system was composed of solar collectors and an absorption chiller with LiBr/water The System performance with commercial single effect(SE) cycle and a new single effect/double lift(SE/DL) cycle utilizing low temperature hot water was calculated and compared. It was found that the required solar collector area grew exponentially as the overall heat loss coefficient of solar collectors increased. For instance, the required area for cooling capacity of 1 USRT was $17m^2$ if heat loss coefficient was 4 W/$m^2\;cdot\;K$. If heat loss coefficient was doubled($8\;W/m^2\;cdot\;$K), the required collector area was increased by 6 times($100m^2$) .It was also found that the SE-cycle as the heat loss coefficient of solar collectors increased. Generally, a SE/DL-cycle seems to be more advantageous than a SE-cycle if loss coefficient of solar collector is greater than 4 W/$m^2\;cdot\;K$.

  • PDF

정밀 마찰측정을 위한 이중 캔틸레버 구조 마찰시험기의 설계에 관한 연구 (A Study on the Design of a Double Cantilever Structure Friction Tester for Precision Friction Measurement)

  • 강원빈;김현준
    • Tribology and Lubricants
    • /
    • 제34권4호
    • /
    • pp.125-131
    • /
    • 2018
  • A precision tribometer consisting of a cantilever was designed to measure frictional forces in the micro-Newton range. As frictional forces are measured based on the bending of the cantilever, vibration of the cantilever is the most significant factor affecting the quality of the friction measurement. Therefore, improved design of the tribometer with double cantilevers and a connecting plate that united the two cantilevers mechanically was suggested. For the verification of the modified design of the tribometer, numerical analysis and experiments were conducted. Examination using the finite element method revealed that the tribometer with a double cantilever and a connecting plate exhibited faster damping characteristics than the tribometer with a single cantilever. In the experiment, effectiveness of the double cantilever and connecting plate for vibration reduction was also confirmed. Vibration of the tribometer with double cantilever decreased eight times faster than that of the tribometer with a single cantilever. The faster damping of the double cantilever design is attributed to the mechanical interaction at the contacting surfaces between the cantilever and the connecting plate. Tribotesting using the tribometer with a single cantilever resulted in random fluctuation of frictional forces due to the stick-slip behavior. However, using the tribometer with a double cantilever and connecting plate for the tribotest gave relatively uniform and steady measurement of frictional forces. Increased stiffness owing to using a double cantilever and mechanical damping of the connecting plate were responsible for the stable friction signal.

선형절삭시험에 의한 더블디스크커터와 싱글디스크커터의 커터 작용력과 축응력에 대한 실험적 평가 (Comparative analysis of cutter acting forces and axial stresses of single and double disc cutters by linear cutting tests)

  • 최순욱;장수호;박영택;이규필;배규진
    • 한국터널지하공간학회 논문집
    • /
    • 제16권2호
    • /
    • pp.181-191
    • /
    • 2014
  • 본 연구는 선형절삭시험 중에 동일한 커터 링 형상을 가진 더블디스크커터와 싱글디스크커터에 발생하는 커터작용력과 각 디스크커터 축에 발생하는 축응력 및 토크를 평가하였다. 선형절삭시험 결과, 선형절삭실험 중에 발생한 더블디스크커터의 연직력과 회전력의 평균값은 싱글디스크커터의 약 두 배 내외인 것으로 측정되었다. 더블디스크커터의 축에 작용하는 축응력의 평균값 역시 연직력과 마찬가지로 싱글디스크커터의 두 배 정도로 나타났지만, 토크의 경우에는 전체적으로 낮은 측정값을 보여 비교의 의미가 없는 것으로 판단되었다. 하지만 더블디스크커터의 연직력의 평균값이 직경 432 mm(17인치) 디스크커터의 허용하중을 상회하기 때문에 테이퍼 롤러 베어링의 내구성능에 대한 검토가 필요한 것으로 판단되었다. 또한 더블디스크커터 축에 작용하는 축응력은 싱글디스크커터의 약 두 배 정도로 발생하였지만, 일반적으로 사용하는 디스크커터 축 재료의 항복강도를 고려할 때 적용 상에 문제가 없는 것으로 나타났다.

Review paper: Application of the Pulsed Eddy Current Technique to Inspect Pipelines of Nuclear Plants

  • Park, D.G.;Angani, C.S.;Kishore, M.B.;Vertesy, G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.342-347
    • /
    • 2013
  • Local wall thinning in pipelines affects the structural integrity of industries, such as nuclear power plants (NPPs). In the present study, a development of pulsed eddy current (PEC) technology that detects the wall thinning of pipelines covered with insulation is reviewed. The methods and experimental results, which have two kinds of probe with a single and double core, were compared. For this purpose, the single and double core probes having one and two excitation coils have been devised, and the differential probe with two Hall sensors has been fabricated to measure the wall thinning in insulated pipelines. The test sample is a stainless steel having different thickness, laminated by plastic insulation to simulate the pipelines in NPPs. The excitation coils in the probe is driven by a rectangular current pulse, the difference of two Hall sensors has been measured as a resultant PEC signal. The peak value of the detected signal is used to describe the wall thinning. The double core probe has better performance to detect the wall thinning covered with insulation; the single core probe can detect the wall thinning up to an insulation thickness of 18 mm, whereas the double probe can detect up to 25 mm. The results show that the double core PEC probe has the potential to detect the wall thinning in an insulated pipeline of the NPPs.

원형 이중겹치기 접착조인트의 해석해에 관한 연구 (An Analytic Study for the Adhesively Bonded Tubular Double Lap Joint)

  • 이수정;이대길
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1412-1420
    • /
    • 1994
  • The adhesively bonded tubular double lap joint has better torque transmission capability and reliability in bonding operation than the single lap joint. In this paper, an analytic solution for the torque transmission capabilities and stress distributions of the adhesively bonded tubular double lap joint was derived assuming the linear properties of the adhesive and adherends. From the calculation, it was found that the torque transmission capabilities of the double lap joint was more than 40% larger compared to that of the single lap joint.