• 제목/요약/키워드: Simultaneous Measurement

검색결과 484건 처리시간 0.035초

디지털영상처리기술을 이용한 비접촉식 유체-구조물 연동운동 3차원 측정시스템 개발에 관한 연구 (A Study on the Development of a Three-dimensional Measurement System for Flow-Structure Interaction Using Digital Image Processing)

  • 도덕희;조효제;상지웅;황태규;조용범;편용범
    • 한국해양공학회지
    • /
    • 제18권4호
    • /
    • pp.1-7
    • /
    • 2004
  • A simultaneous measurement system that can analyze the flow-structure interaction has been developed. This system consists of four CCD cameras, two for capturing instantaneous flow fields and two for tracking a solid body. The three-dimensional vector fields around a cylinder are measured, while the motion of the cylinder forced by the flow field is measured, simultaneously, with the constructed system. The cylinder is suspended in the working fluid of a water channel, and the surface of the working fluid is forced sinusoidally to make the cylinder bounced. Reynolds number for the mean main stream is about 3500. The interaction between the flow fields and the cylinder motion is examined quantitatively.

Validation and measurement uncertainty of HPLC method for simultaneous determination of 10 dyes in adulterated Phellodendron

  • Lim, Suji;Yun, Choong-In;Ko, Kyung Yuk;Kim, Young-Jun
    • 한국식품과학회지
    • /
    • 제53권4호
    • /
    • pp.391-398
    • /
    • 2021
  • As global interest in herbal medicines has increased, the adulteration of herbal medicines has become a critical safety issue. Adulteration with dyes to improve the appearance of low-quality products is of particular concern. This study aimed to develop a high-performance liquid chromatography (HPLC) method to detect dyes added as adulterants to Phellodendron. Samples were analyzed on a C18 column using 50 mM ammonium acetate and acetonitrile as the mobile phase. All calibration curves showed good linearity (r2 ≥0.9999) over the five-point concentration range (1-50 mg/kg). Limit of detection ranged from 0.04-0.35 mg/kg, and limit of quantification ranged from 0.11-1.07 mg/kg. The repeatability and reproducibility for these measurements were 94.2-103.3% and 96.6-103.8% for accuracy and 0.14-2.28 RSD (%) and 0.80-2.37 RSD (%) for precision. Moreover, the measurement uncertainty of the low, medium, and high concentrations for 10 dyes was considered. Thus, this HPLC method is suitable for detecting color adulteration of Phellodendron.

터보프롭 엔진의 최적 계측 변수 선정을 위한 비선형 GPA 기법에 관한 연구 (A Study on Nonlinear GPA for Optimal Measurement Parameter Selection of Turboprop Engine)

  • 공창덕;기자영
    • 한국추진공학회지
    • /
    • 제5권1호
    • /
    • pp.69-75
    • /
    • 2001
  • 터보프롭 엔진의 성능진단을 위한 선형 GPA(Gas Path Analysis) 및 비선형 GPA 프로그램을 개발하고 최적 계측 변수 선정을 위한 해석을 수행하였다. 엔진의 손상은 압축기 오염과 압축기 터빈 및 동력터빈의 부식이 동시에 발생하는 경우를 가정하였다. 먼저 비선형 GPA에서 반복기법에 대한 영향을 알아보기 위해 독립변수의 저하량을 등간격으로 나누어 반복 해석한 경우와 Newton-Raphson법을 이용하여 해석한 경우를 선형 GPA 해석 결과와 비교하였다. 해석 결과 비선형 GPA의 성능은 반복기법에 의해 많은 영향을 받음을 알 수 있었다. 다음 계측변수 수에 대한 영향을 알아보기 위해 계측변수를 6개, 8개, 10개로 달리하여 각각 선형 GPA 기법과 비선형 GPA 기법을 이용하여 해석을 수행한 후 RMS 오차를 비교하였다. 해석 결과 계측변수가 많으면 보다 정확한 진단 결과를 얻을 수 있으나 계측변수를 잘 선정한다면 보다 적은 계측변수로도 신뢰성 있는 결과를 얻을 수 있음을 확인하였다. 또한 비선형 GPA 기법을 이용한 경우의 RMS 오차가 선형 GPA 기법을 이용한 경우보다 적어 비선형 GPA 기법의 유용성을 알 수 있었다.

  • PDF

악관절장애진단에 있어서 동시다층개별화측방단층촬영의 진단효과 (THE DIAGNOSTIC EFFECT OF THE SIMULTANEOUS MULTIFILM INDIVIDUALIZED LATERAL TOMOGRAPHY IN THE DIAGNOSIS OF THE TEMPOROMANDIBULAR DISORDERS)

  • 이우식;박태원
    • 치과방사선
    • /
    • 제21권2호
    • /
    • pp.235-248
    • /
    • 1991
  • This study was designed to evaluate the diagnostic effect of the simulatneous multifilm individualized lateral tomography in the diagnosis of the temporomandibular disorders. The subjects consisted of 29 patients with symptoms of the temporomandibular disorders. The panoramic view, oblique lateral transcranial radiograph (OLTC) (Hirozontal angulation 0°, Vertical angulation 29°), submentovertex view, and simultaneous multifilm individualized lateral tomographs (SMFI) in centric occlusion (2.5㎜ thickness difference, 5 layers) were taken for the patients. This study compared the findings from each radiographs in the determining of mandibular condylar position with dual linear measurement of the subjective closest posterior and subjective closest anterior interarticular space and in the determining of bony changes on the studied 30 temporomandibular joints (TMJ) with symptoms of the temporomandibular disorders. The results were as follows: 1. The distribution of condylar position of OLTC and 5 layers of SMFI depended on the radiographs (p<0.05). The condylar position and the distribution of condylar position of OLTC were more similar to lateral sections of the SMFI than mesial sections, and in the distribution of the condylar position of SMFI, the more lateral sections of SMFI, the more concentric 2. positions. There were 10 cases in which all layers showed the same condylar position as that of OLTC. There were 3 cases in which no layers showed the same condylar position as that of OLTC. 3. In the SMFI of 30 Temporomandibular joints studied, there is 13 cases in which all five layers represented the same condylar position in the same TMJ and 11 cases in which 4 layers represented the same condylar position in the same TMJ and 6 cases in which 3 layers represented the same condylar position in the same TMJ. So at least 3 layers of SMFI represented same condylar position in the same TMJ. 4. The bony changes were not detected in conventional radiographs on the temporomandibular joint and the bony changes were not detected in simultaneous multifilm individualized lateral tomographs. The bony changes were detected in conventional radiographs on the temporomandibular joint and the bony changes were detected in simultaneous multifilm individualized lateral tomographs. SMFI provided a meams for a three dimensional visualization of the shape, the position and the extent of bony changes of TMJ.

  • PDF

수종 상아질 접착제의 결합강도와 중합률에 관한 연구 (A STUDY ON BONE STRENGTH AND THE DEGREE OF CONVERSION OF DENTIN BONDING AGENTS)

  • 김병현;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.68-93
    • /
    • 1998
  • The physical properties of polymer are greatly influenced by the extent to which a resin cures. The presence of un reacted monomer can, have a plasticizing effect on the polymer, thereby altering the physical and mechanical properties of dentin bonding agent (DBA). If the DBA does not polymerize sufficiently, it will leave a weak bonding layer and lead to lower bond strength. The purpose of this study was to evaluate the shear bond strengths(SBS) and the degree of conversion (DC) of 4 commercialy avilable dentin bonding systems which are composed of 2 multi-bottle systems [Scotchbond Multi-Purpose (SMP), AeliteBond(AB)] and 2 onebottle systems [SingleBond(SB), One-Step(OS)]. For shear bond strength measurement, labial surfaces of freshly extracted bovine incisors were ground with # 600 grit SiC paper to expose dentin. Four different groups of samples were formed, with 10 samples. being made for each of the 4 commercial DBA in each group according to the curing sequences of DBA and overlayer thickness of composites: Group I (standard cure and 1mm thick composites) : The DBA was light cured and the composites of 1mm thickness was applied ; Group II (standard cure and 2mm thick composites) : The DBA was light cured and the composites of 2mm thickness was applied; Group III (simultaneous cure and 1mm thick composites) : The DBA was not light-cured and simultaneously cured with composites of 1mm thickness; Group N (simultaneous cure and 2mm thick composites) : The DBA was. not light-cured and simultaneously cured with composites of 2mm thickness. The SBS was measured immediately after the composites was bonded to the bovine dentin using an Instron machine. The DC of the DBA was examined in a thin film under simulated conditions of the experimental groups according to the curing sequences and overlayer thickness of composites in the SBS test. using a Fourier transform Infrared(FTIR) spectrometer. The following results were obtained from SBS tests and DC measurements 1. In SBS tests, the multi-bottle DBA(SMP, AB) had a generally higher bond strength values than the one bottle DBA(SB, OS). In DC measurements, the one bottle DBA(SB, OS) had a significantly higher DC than the multi-bottle DBA(SMP, AB). 2. In all DBAs except OS, there was no significant difference between the bond strength of group I (standard cure and 1mm thick composites) and that of group III (simultaneous cure and 1mm thick composites). SMP, SB in Group I had a significantly higher DC than those in group III, but AB, OS in group I had a significantly lower DC than those in group III 3. All DBAs in Goup II (standard cure and 2mm thick composites) had significantly higher bond strength and DC than those in Group N (simultaneous cure and 2mm thick composites). 4. In all DBAs, there was no significantly different SBS and DC between Group I and Group II, but all DBAs in Group III had significantly higher SBS and DC than those in Group IV.

  • PDF

액정셀의 선경사각과 액정층의 두께를 함께 재는 개선된 결정회전법 (An improved crystal rotation method for simultaneous measurement of pretilt angle and thickness of a liquid crystal layer)

  • 손공숙;박찬;박희갑;김진승;노봉규;이형종;김재기
    • 한국광학회지
    • /
    • 제7권3호
    • /
    • pp.213-218
    • /
    • 1996
  • 액정셀에서 액정분자의 선경사각과 액정층의 두께를 함께 결정하며 측정범위와 정밀도를 높이는 개선된 결정회전법을 고안하고 그 타당성을 실험으로 확인하였다. 이 방법은 종래의 입사각에 따른 편광투과율의 변화를 재는 대신, 직교하는 두 선편광이 액정셀을 지나올 때의 위상차를 재고 그 결과를 바탕으로 액정층의 두께와 선경사각을 결정한다. 아울러 굴절율이 유리기판과 비슷한 액체가 채원진 액체통에 액정셀을 넣고 실험하여 유리판 표면에서의 빛의 반사를 줄이고 액정층에서의 굴절각의 범위를 늘려서 측정의 정밀도를 높였다. 이 방법을 쓰면 액정층의 두께가 10.mu.m보다 적거나 선경사각이 10.deg. 이상인 액정셀에 대해서도 선경사각과 액정층의 두께를 동시에 잴 수 있다.

  • PDF

IoT 기반 하이브리드 계측시스템 실시간 다점 측정 성능 평가 (Evaluation on real-time multi-point sensing performance of IoT-based hybrid measurement system)

  • 김헌영;강동훈
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.543-550
    • /
    • 2018
  • 4차 산업혁명의 도래와 함께 빠른 속도로 발전하고 있는 IoT 기술은 다양한 센서의 무선화를 가능하게 하였으며 많은 분야에서 응용연구가 활발히 진행되고 있다. 하지만, 철도현장의 경우 수 km에 이르는 교량, 터널 등 계측사이트의 규모가 매우 방대한 특징으로 인해, 보편적으로 활용되는 전기식 센서의 경우 원거리 계측으로 인한 신호 잡음 문제, 전철화에 따른 고전압 환경에 기인한 전자기파 간섭 문제로 계측에 어려움이 있다. 이를 극복하고자, 전기식 센서를 대체하기 위한 광섬유 센서 연구가 많이 수행되었으나, 센서 종류의 다양성 부족 등이 현장 적용의 한계로 작용하고 있는 실정이다. 이런 현장의 상황을 토대로, 전기식 센서와 광섬유 센서를 동시에 사용할 수 있으며 IoT 기술을 통해 무선 데이터 통신이 가능한 하이브리드 계측시스템이 개발되었다. 본 연구에서는, 선행연구를 통해 개발된 하이브리드 계측시스템의 다양한 계측현장 적용성을 평가하기 위해 4가지 형태의 계측환경을 모사하여 실시간 계측 실험을 수행하였다. 실험결과, 전기식 및 광학식 센서 모두 높은 추종성을 보이며 원격지에서 실시간으로 계측이 가능하였으며, 본 계측시스템이 50개의 센서를 동시에 2.5kHz의 샘플링으로 계측할 경우에도 적용 가능한 수준임을 확인하였다. 향후, IoT 기반 하이브리드 계측시스템의 다양한 현장 적용을 통해 실시간 건전성 모니터링 기술 기반의 구조안전성 향상에 기여할 것으로 기대한다.

Isotope Measurement of Uranium at Ultratrace Levels Using Multicollector Inductively Coupled Plasma Mass Spectrometry

  • Oh, Seong-Y.;Lee, Seon-A.;Park, Jong-Ho;Lee, Myung-Ho;Song, Kyu-Seok
    • Mass Spectrometry Letters
    • /
    • 제3권2호
    • /
    • pp.54-57
    • /
    • 2012
  • Mass spectrometric analysis was carried out using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) for the precise and accurate determination of the isotope ratios of ultratrace levels of uranium dissolved in 3% $HNO_3$. We used the certified reference material (CRM) 112-A at a trace level of 100 pg/mL for the uranium isotopic measurement. Multiple collectors were utilized for the simultaneous measurement of uranium isotopes to reduce the signal uncertainty due to variations in the ion beam intensity over time. Mass bias correction was applied to the measured U isotopes to improve the precision and accuracy. Furthermore, elemental standard solution with certified values of platinum, iridium, gold, and thallium dissolved in 3% $HNO_3$ were analyzed to investigate the formation rates of the polyatomic ions of $Ir^{40}$ $Ar^+$, $Pt^{40}$ $Ar^+$, $Tl^{40}$ $Ar^+$, $Au^{40}$ $Ar^+$ for the concentration range of 50-400 pg/mL. Those polyatomic ions have mass-to-charge ratios in the 230-245 m/z region that it would contribute to the increase of background intensity of uranium, thorium, plutonium, and americium isotopes. The effect of the polyatomic ion interference on uranium isotope measurement has been estimated.

QUANTITATIVE MONITORING OF TISSUE OXYGENATION BY TIME-RESOLVED SPECTROSCOPY

  • Yamashita, Yutaka;Oda, Motoki;Ohmae, Etsuko;Tsuchiya, Yutaka
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.2101-2101
    • /
    • 2001
  • Near-infrared spectroscopy is now being used in clinical diagnosis as a non-invasive monitor of tissue oxygenation state. However, due to lack of the optical pathlength information within tissues, it is still difficult to quantitate the hemoglobin concentration with present CW techniques. Time-resolved spectroscopy (TRS), which measures temporal profiles of emerging light from tissues, enables to estimate the pathlength distribution within tissues by converting time to distance. Consequently, quantitative measurement of tissue oxygenation is possible by analyzing the data with optical diffusion equation 1) or our Microscopic Beer-Lambert law2). Time-Resolved Spectroscopy System : TRS-1O3) Our TRS-10 system consists of a three-wavelength (759, 797, 833 nm) PLP as pulsed light source, a high speed PMT with high sensitivity and three signal-processing circuits for time-resolved measurement (CFD/TAC, A/D converter and histogram memory). Optical pulse train consisting of 759, 797 and 833nm is generated by PLP at 5㎒ repetition rate and irradiated a sample through a single optical fiber. The diffuse-reflected light from the sample is collected by a bundle fiber and then detected by the PMT for single photon measurement. After being amplified by a following fast amplifier, the electrical signals for each wavelength are picked out by CFD/TAC module. Then, a signal processing circuit integrated the TRS data for each wavelength individually. The simultaneous TRS measurement for three wavelengths achieved without any optical or mechanical switch. Experiment and Results Input and detection fibers of TRS-10 were attached at the human forehead with a fiber separation of 3cm. TRS measurements were continuously performed for about 20 minutes including 2 minutes hyper ventilation. It was observed that the total hemoglobin concentration was decreasing during the hyper ventilation and recovered until 2 minutes after hyper ventilation. On the other hand, the deoxy-hemoglobin concentration began to increase after hyper ventilation and had its peak at around 2 minute later, showing 502 drop from 75% to 60% due to inhibition of breathing by performing hyper ventilation. The results showed that this system might be able to quantitate the concentrations of oxy- and deoxy-hemoglobin in the human brain.

  • PDF

심전도와 심탄도의 무구속적 동시 측정을 위한 의자 등받이 개발 (Development of Chair Backrest for Non-intrusive Simultaneous Measurement of ECG and BCG)

  • 임용규
    • 융합신호처리학회논문지
    • /
    • 제19권3호
    • /
    • pp.104-109
    • /
    • 2018
  • 심전도와 심탄도를 무구속적으로 동시에 측정하는 시스템을 개발하였다. 제안된 시스템은 의자의 보조 등받이에 설치되어 맥파전달시간(PAT), Pre-ejection period (PEP) 등의 심혈관계 역학 정보를 일상생활에서 무구속적으로 측정하는 것을 목적으로 개발되었다. 본 연구에서는, 의자의 등받이에 부착된 용량성 능동전극과 용량성 접지를 이용한 간접접촉 심전도 (IDC-ECG) 측정 방법에 의해 무구속적으로 심전도를 측정하였으며, 등받이에 부착된 EMFi 압력 센서를 사용하여 무구속적으로 심탄도(ballistocardiogram)를 측정하였다. 제안된 시스템으로 심전도와 심탄도가 무구속적으로 동시에 측정됨을 확인하였으며, 측정된 심탄도는 피검자 사이에서 일정한 패턴을 보이는 것을 알 수 있었다. 또한 심전도의 Q파와 심탄도의 첫 번째 첨두간의 시간차가 pre-ejection period와 높은 상관관계를 보이는 것도 확인할 수 있었다. 이 연구에서 개발된 시스템은 심혈관계의 다양한 지표(심전도, 심박수, PAT, PEP 등)를 무구속적으로 일상생활에서 측정할 수 있음을 보였다.