• 제목/요약/키워드: Simulated Signal Generator

검색결과 58건 처리시간 0.027초

수중에서 펄스초음파 신호에 대한 Sagnac 간섭형 광섬유센서의 특성 연구 (A Study on Characteristics of Sagnac Interferometric Optical Fiber Sensor to Pulsed Ultrasonic Signal in Underwater)

  • 이준호;신대용
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권1호
    • /
    • pp.15-19
    • /
    • 2004
  • In this paper, we present the fabrication and characteristic analysis of Sagnac interferometric optical fiber senior(OFS) system for detecting pulsed ultrasonic signal in underwater. The hollow cylindrical mandrel wound round by single mode optical fiber is used as sensing component. The ultrasonic signal source is simulated by the PZT actuator operated by an function generator. The distance dependency of the OFS's sensitivity was measured. The sensitivity has been shown to be inversely propotional to the square-root of distance between ultrasonic source and sensing component. It has also been shown that the OFS could detect the signals less affected by ultrasonic path comparing to conventional acousto-electric sensor. and accurate location of ultrasonic signal could be carried out using two OFSs.

빗살형 전극을 가지는 정전용량형 습도센서와 그 신호처리회로의 설계와 제작 (The Design and Fabrication of Capacitive Humidity Sensor Having Interdigit Electrodes and its Signal Conditional Circuitry)

  • 박세광;강정호;박진수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권3호
    • /
    • pp.144-148
    • /
    • 2001
  • For the purpose of developing capacitive humidity sensor having interdigit electrodes, interdigit electrode was modeled and simulated to obtain capacitance and sensitivity as a function of geometric parameters like the structural gap and thichness. For the development of ASIC, switched capacitor signal conditioning circuits for capacitive humidity sensor were designed and simulated by cadence using 0.25um CMOS process parameters. The signal conditioning circuits are composed of amplifier for voltage gain control, and clock generator for sensor driving and switch control The characteristics of the fabricated sensors are; 1) sensitivity is 9fF/%R.H., 2) temperature coefficient of offset(TCO) is 0.4%R.H./$^{\circ}C$, 3) nonlinearity is 1.2%FS, 4) hysteresis is 1.5%FS in humidity range of 3%R.H. ${\sim}$ 98%R.H.. The response time is 50 seconds in adsorption and 70 seconds in desorption. Fabricated process used in this capacitive humidity sensor having interdigit electrode are just as similar as conventional IC process technology. Therefore this can be easily mass produced with low cost, simple circuit and utilized in many applications for both industrial and environmental measurement and control system, such as monitoring system of environment, automobile, displayer, IC process room, and laboratory etc..

  • PDF

Voltage-Mode CMOS Squarer/Multiplier Circuit

  • Bonchu, B.;Surakampontorn, W.
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.646-649
    • /
    • 2002
  • In this paper, a low-voltage CMOS squarer and a four-quadrant analog multiplier are presented. It is based on a source-coupled pair and a scaled-floating voltage generator which are modified to work as a voltage squaring and a sum/difference circuits. The proposed squarer/multiplier have been simulated with HSPICE, where -3㏈ bandwidth of 10MHz is achieved. The power consumption is about 0.6㎽, from a ${\pm}$1.5V supply, and the total harmonic distortion is less than 0.7%, with a 1.2V peak-to-peak 1MHz input signal.

  • PDF

카오스 신경망을 위한 CMOS 혼돈 뉴런 (CMOS Chaotic Neuron for Chaotic Neural Networks)

  • 송한정;곽계달
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(3)
    • /
    • pp.5-8
    • /
    • 2000
  • Voltage mode chaotic neuron has been designed in integrated circuit and fabricated by using 0.8$\mu\textrm{m}$ single poly CMOS technology. The fabricated CMOS chaotic neuron consist of chaotic signal generator and sigmoid output function. This paper presents an analysis of the chaotic behavior in the voltage mode CMOS chaotic neuron. From empirical equations of the chaotic neuron, the dynamical responses such as time series, bifurcation, and average firing rate are calculated. And, results of experiments in the single chaotic neuron and chaotic neural networks by two neurons are shown and compared with the simulated results.

  • PDF

GIS 진단시스템의 평가를 위한 PD 모의 펄스발생기 개발에 관한 연구 (A Study on the Development of PD Simulation Pulse Generator for Evaluation of GIS Diagnosis System)

  • 김성주;장석훈;조국희
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.21-27
    • /
    • 2018
  • The expansion and stable operation of electric power facilities are important factors with development of industrial facilities in modern society. In high-voltage equipment such as GIS, the insulation characteristics may be deterioated by environment-friendly gas adaption and miniaturization. There is also the possibility of accidents due to insulation breakdown due to the deterioration of power facilities. Therefore, it is necessary to extend the diagnosis system to continuously monitor the danger signals of these power equipment and to prevent accidents. Most of the internal defects in the GIS system are conductive particles, floating electrode defects, protrusion defects, and the like. In this case, a partial discharge phenomenon is accompanied. These partial discharge signals occur irregularly and various noise signals are included in the field, so it is difficult to evaluate the reliability in the development of the diagnostic system. In this paper, a study was made on equipment capable of generating a partial discharge simulated signal that can be adjusted in size and frequency to be applied to a diagnostic device by electromagnetic wave detection method. The PD simulated pulse generator consists of a user interface module, a high-voltage charging module, a pulse forming circuit, a voltage sensor and an embedded controller. In order to simulate the partial discharge phenomenon similar to the actual GIS, a discharge cell was designed and fabricated. The application of the prototype pulse generator to the commercialized PD diagnosis module confirmed that it can be used to evaluate the performance of the diagnostic device. It can be used for the development of GIS diagnosis system and performance verification for reliability evaluation.

직렬아크신호의 검출 (Detection of Series Arc Signal)

  • 지홍근;박대원;김일권;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.225-229
    • /
    • 2008
  • This paper describes a series arc detection algorithm in a low-voltage wiring system. We designed and fabricated an arc detection circuit which consists of a high-pass filter with the low cut-off frequency of 3 kHz to attenuate power frequency. The series arcing phenomena was simulated by an arc generator specified in UL1699. In the experiment, various loads such as resistive loads, resistive loads controlled by a dimmer, and vacuum cleaners were used. Whether the signal is arc or noise is discriminated by pulse counts and periodicity of the detected signal.

  • PDF

인공지능기법에 근거한 철도 전자연동장치의 연동 지식베이스 자동구축 S/W 개발 (Software Development for Auto-Generation of Interlocking Knowledgebase Using Artificial Intelligence Approach)

  • 고윤석;김종선
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.800-806
    • /
    • 1999
  • This paper proposes IIKBAG(Intelligent Interlocking Knowledge Base Generator) which can build automatically the interlocking knowledge base utilized as the real-time interlocking strategy of the electronic interlocking system in order to enhance it's reliability and expansion. The IIKBAG consists of the inference engine and the knowledge base. The former has an auto-learning function which searches all the train routes for the given station model based on heuristic search technique while dynamically searching the model, and then generates automatically the interlocking patterns obtained from the interlocking relations of signal facilities on the routes. The latter is designed as the structure which the real-time expert system embedded on IS(Interlocking System) can use directly in order to enhances the reliability and accuracy. The IIKBAG is implemented in C computer language for the purpose of the build and interface of the station structure database. And, a typical station model is simulated to prove the validity of the proposed IIKBAG.

  • PDF

시스템 제너레이터 환경에서 순시 절대값을 이용한 가변스텝사이즈 적응알고리즘 (Variable Step Size Adaptive Algorithm using Instantaneous Absolute Value Based on System Generator)

  • 이채욱;류정탁
    • 한국산업정보학회논문지
    • /
    • 제21권3호
    • /
    • pp.1-6
    • /
    • 2016
  • LMS 알고리즘에서, 시간영역의 적응알고리즘은 입력신호의 고유치 분포 폭이 넓게 분포되면, 수렴속도가 느려지기 때문에 가변 스텝 사이즈가 많이 사용된다. 그러나 이 경우 많은 계산량이 필요하다. 본 논문에서는 시간영역의 적응 알고리즘을 변환영역에서 수행한다. 그리고 수렴성능 향상과 계산량을 줄이기 위하여 평균오차의 순시 절대 값을 exponential 함수에 적용한 새로운 알고리즘을 제안한다. 그리고 시스템 제너레이터를 이용하여 시뮬레이션 및 검증을 하였다. 그 결과 순시 절대 값에 비례하여 변화하는 가변스텝사이즈의 적응알고리즘이 기존의 알고리즘과 비교하여 보다 안정되고 성능이 우수함을 입증하였다.

디지털 고주파 메모리 구현에 관한 연구 (A Study on the Implementation of Digital Radio Frequency Memory)

  • 유병석;김영길
    • 한국정보통신학회논문지
    • /
    • 제14권9호
    • /
    • pp.2164-2170
    • /
    • 2010
  • Digital radio frequency memory (이하 DRFM)은 입력되는 RF신호를 저장 후 필요한 시점에 입력된 RF신호로 복원하여 출력하는 기능을 가진 장치로써 Jammer, EW시뮬레이터, Target Echo Generator[1] 등 사용되는 분야가 광범위하다. 본 논문에서는 고주파 입/출력모듈, 국부 발진모듈로 구성된 고주파부와 디지털 처리부로 이루어진 DRFM의 하드웨어적 구현 방안을 제안한다. 그리고 펄스형태의 RF신호를 양자화하는 ADC(A/D conversion), 이 데이터를 저장하고 재생신호를 생산하는 FPGA와 RF 신호를 생산하는 DAC(D/A conversion)로 구성되는 디지털 처리부에서 복제된 신호 생성방안을 제안한다. 이렇게 제안된 방안을 적용하여 제작한 후 모의 신호를 입력하여 얻은 시험결과를 통하여 이 제안방안의 타당성을 확인한다.

수중에서 2개의 광섬유센서를 이용한 초음파 음원의 위치 검출에 관한 연구 (A Study on Ultrasonic Location in Underwater Using the Two Optical Fiber Sensors)

  • 권태호;신대용;이준호;이종길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.62-66
    • /
    • 2002
  • The preliminary results on the application of optical fiber sensor(OFS) for locations of ultrasonic signals in underwater are presented and analyzed. The OFS utilizing the principle of Sagnac interferometry was designed and the hollowed cylindrical mandrel wound by single mode optical fiber was used as sensing component. The ultrasonic signal source was simulated by the PZT actuator operated with function generator. It has been shown that the OFS could detect the signals less affected by ultrasonic path comparing to conventional acousto-electric sensor and accurate location of ultrasonic signal could be carried out using two OFSs.

  • PDF