• Title/Summary/Keyword: Simple X-ray

Search Result 574, Processing Time 0.028 seconds

Congenital Cystic Adenomatoid Malformation (선천성 낭포성 선종양 기형 -1례 보고-)

  • 장기경
    • Journal of Chest Surgery
    • /
    • v.28 no.7
    • /
    • pp.726-730
    • /
    • 1995
  • Congenital cystic adenomatoid malformation[CCAM of the lung is extremely rare. We have experienced an unusual case of congenital cystic adenomatoid malformation. The patient was 20-year-old male and had chest pain for 10 days. On simple chest x-ray and Thoracic CT scan, there was a large cystic mass surrounded with multiloculated round cysts with air fluid level on the right lower lobe of a lung. Right lower lobectomy was performed and the pathologic result was congenital cystic adenomatoid malformation.

  • PDF

Synchrotron-based Transmission X-ray Microscopy (TXM) Observations of Fully Hydrated Blood Platelets and Their Activation Process

  • Yang, Nuri;Nho, Hyun Woo;Kalegowda, Yogesh;Kim, Jin Bae;Song, Jaewoo;Shin, Hyun-Joon;Yoon, Tae Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2625-2629
    • /
    • 2014
  • Platelets are anuclear discoid-shaped blood cells with key roles in human body. To understand the mechanisms of their activation process, it is required to have analytical imaging techniques capable of acquiring platelet images under fully hydrated conditions. Herein, for the first time, we demonstrate the capability of synchrotron-based transmission X-ray microscopy (TXM) to study platelets (resting and ADP activated) under hydrated and air-dried conditions. To confirm the biological imaging capability of TXM, fixed platelets were imaged and compared with whole mount electron microscopy (EM) images. TXM provided morphological information with sufficient spatial resolution with simple and quick sample preparation procedure. We also observed temporal changes during the platelet activation, which initially had a discoid shape (0 s), formed pseudopodia (30 s) and generated a network of fibrin (5 min). Our results clearly demonstrate the potential of TXM technique to study fully hydrated biological samples under in situ conditions.

Relations between Airway Narrowing and Prevertebral Soft Tissue Swelling after Anterior Cervical Spine Surgery : The Value of Lateral Neck Radiographs

  • Kim, Hee-Seop;Youm, Jin-Young;Kwon, Hyon-Jo;Choi, Seung-Won;Kim, Seon-Hwan;Koh, Hyeon-Song
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.97-102
    • /
    • 2007
  • Objective : The authors attempted to evaluate the pattern of the airway narrowing due to prevertebral soft tissue swelling after surgery of the anterior cervical spine and their clinical significances using plain cervical X-ray images. Methods : Twenty-four patients undergoing anterior cervical spine surgery were reviewed from January 2004 to December 2005. Postoperatively, in daily basis, lateral radiograph of the neck was obtained in neutral position. We measured the upper airway diameter above and below the epiglottis level and prevertebral soft tissue diameter every day for a week and finally 2 weeks after surgery using their simple lateral cervical X-ray films. Results : Both airway narrowing and prevertebral soft tissue swelling were maximum in postoperative 2 days, and decreased rapidly in postoperative 7 days. Airway narrowing was aggravated postoperatively but slowly decreased as prevertebral soft tissue swelling diminished. But, the severity of airway narrowing showed no clinical correlations with clinical symptom and radiologic severity. Conclusion : Not all patients who show severe airway narrowing and prevertebral soft tissue swelling on their plain cervical X-ray film complain respiratory insufficiency. But, the patients with undergoing anterior cervical spine surgery should be monitored carefully for respiratory insufficiency, especially during several days following operation because both airway narrowing and prevertebral soft tissue swelling become peak at postoperative 2-3 days.

APPLICATION OF SUPPORT VECTOR MACHINE TO THE PREDICTION OF GEO-EFFECTIVE HALO CMES

  • Choi, Seong-Hwan;Moon, Yong-Jae;Vien, Ngo Anh;Park, Young-Deuk
    • Journal of The Korean Astronomical Society
    • /
    • v.45 no.2
    • /
    • pp.31-38
    • /
    • 2012
  • In this study we apply Support Vector Machine (SVM) to the prediction of geo-effective halo coronal mass ejections (CMEs). The SVM, which is one of machine learning algorithms, is used for the purpose of classification and regression analysis. We use halo and partial halo CMEs from January 1996 to April 2010 in the SOHO/LASCO CME Catalog for training and prediction. And we also use their associated X-ray flare classes to identify front-side halo CMEs (stronger than B1 class), and the Dst index to determine geo-effective halo CMEs (stronger than -50 nT). The combinations of the speed and the angular width of CMEs, and their associated X-ray classes are used for input features of the SVM. We make an attempt to find the best model by using cross-validation which is processed by changing kernel functions of the SVM and their parameters. As a result we obtain statistical parameters for the best model by using the speed of CME and its associated X-ray flare class as input features of the SVM: Accuracy=0.66, PODy=0.76, PODn=0.49, FAR=0.72, Bias=1.06, CSI=0.59, TSS=0.25. The performance of the statistical parameters by applying the SVM is much better than those from the simple classifications based on constant classifiers.

Cross-Calibration of Domestic Devices and GE Lunar Prodigy Advance Dual-Energy X-Ray Densitometer Devices for Bone Mineral Measurements (국산 이중에너지 방사선흡수 골밀도 장치와 GE Lunar Prodigy의 교차분석 식 도출에 관한 연구)

  • Kim, Jung-Su;Rho, Young-Hoon;Lee, In-Ju;Kim, Kyoung-Ah;Lee, In-Ja;Kim, Jung-Min
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.27-31
    • /
    • 2017
  • Reliable follow-up of bone mineral density (BMD) by dual energy X-ray absorptiometry (DXA) is essential in clinical practice. When there is a difference in the BMD values from DXA systems in the same patient, cross calibration equation is required for the reliable follow-up. Unfortunately, no equation is existed in BMD measure between GE Lunar Prodigy Advance (US, GE Healthcare; LPA) and Osteosys Dexxum T (Korea, Osteosys; ODT) DXA systems. In this study, we evaluate the agreement of BMD values between LPA and ODT and suggest the cross calibration equation using European spine phantom (ESP) with two systems. We performed BMD measurements using ten scans with ESP in each DXA systems. We compared BMD values and calculated cross calibration equation by linear regression analysis. The comparison between the LPA and ODT bone densitometers used the ESP. Compared to the ESP BMD values, ODT underestimated 14.36% and LPA overestimated 12.96%. The average of total BMD measurement values acquired with ODT were 21.44% lower than those from LPA. Cross-calibration equation for LPA and ODT was derived from ESP. We calculated simple cross calibration equation for LPA and ODT DXA systems. Cross-calibration equation is necessary for the reliable follow-up of BMD values in two different systems.

One-pot synthesis of silica-gel-based adsorbent with Schiff base group for the recovery of palladium ions from simulated high-level liquid waste

  • Wu, Hao;Kim, Seong-Yun;Ito, Tatsuya;Miwa, Misako;Matsuyama, Shigeo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3641-3649
    • /
    • 2022
  • A simple solvothermal reaction was used to prepare a 3-aminopropyl-functionalized silica-gel-based adsorbent for adsorbing Pd(II) from the nitric acid solution. Scanning electron microscopy, fourier transform infrared spectroscopy, and thermogravimetry analysis were performed on the as-synthesized adsorbent to demonstrate the successful introduction of Schiff base groups. Batch experiments were used to investigate the effects of contact time, nitric acid concentration, solution temperature, and adsorption capacity. It is worth noting that the prepared adsorbent exhibited a higher affinity toward Pd(II) with the uptake approximately 100% even in a 2 M HNO3 solution. At an equilibrium time of 5 h, the maximum adsorption capacity of Pd(II) was estimated to be 0.452 mmol/g. The adsorbed Pd(II) could be completely eluted by dissolving 0.2 M thiourea solution in 0.1 M HNO3. Using a combination of particle-induced X-ray emission analysis and an X-ray photoelectron spectrometer, the adsorbed Pd was found to be uniformly distributed on the surface of the prepared adsorbent and the existing species were Pd(II) and zero-valent Pd(0). Due to the desirable performances, facile preparation method, and abundant raw material source, the prepared adsorbent demonstrated a high application potential in the recovery of Pd(II) from simulated high-level liquid waste treatment.

γ-ray Radiation Induced Synthesis and Characterization of α-Cobalt Hydroxide Nanoparticles

  • Kim, Sang-Wook;Kwon, Bob-Jin;Park, Jeong-Hoon;Hur, Min-Goo;Yang, Seung-Dae;Jung, Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.4
    • /
    • pp.910-914
    • /
    • 2010
  • A novel synthetic route has been developed to prepare $\alpha$-cobalt hydroxide with intercalated nitrate anions. It was successfully synthesized by $\gamma$-ray irradiation under simple conditions, i.e., air atmosphere, without base. Under $\gamma$-ray irradiation, it leads to the formation of layered cobalt hydroxynitrate compounds which have small crystalline size and have the role of a generator of hydroxyl anion. Structural and morphological characterizations were performed by using power X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), and high resolution transmission electron microscopy (HR-TEM). The component and thermal stability of the sample were respectively measured by Fourier transform infrared (FT-IR) spectroscopy, elemental analysis, and thermal analyses, including thermogravimetry (TG) and differential thermal analysis (DTA).

Speckle Reduction based on Neuro-Fuzzy Technique (뉴로-퍼지를 이용한 스펙클 제거)

  • Kil, Se-Kee;Jeon, Yu-Yong;Oh, Hyung-Seok;Nishimura, Toshihiro;Kwon, Jang-Woo;Lee, Sang-Min
    • Journal of IKEEE
    • /
    • v.12 no.3
    • /
    • pp.158-166
    • /
    • 2008
  • Medical ultrasound has benefits in mobility and safety than any other medical techniques such as X-ray, CT and MRI but has speckle noise which decrease the ability of an observer to distinguish the fine details in diagnostic examination. But simple removing of speckle often causes losing boundary information. Then, in this paper, we presented a novel neuro-fuzzy method which could remove speckle efficiently without loss of boundary information. Proposed method consists of image clustering by fuzzy algorithm and image processingby neural networks which was learned by back propagation. From the experiments for simulation image and real ultrasound image, we could verify the proposed method.

  • PDF

Spontaneous Hemothorax in a Patient with Posterior Mediastinal Neurilemmoma -A case report- (자발성 혈흉을 동반한 후종격동 신경섬유초종)

  • 김혁;양주민;정기천;김영학;강정호;정원상
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.1019-1021
    • /
    • 2004
  • Neurogenic tumors are common in posterior mediastinal tumors. In most cases, tumors were accidentally showed on simple chest X-ray. In some cases, they were presented by symptoms which were induced by nerve compression or airway compression. But as in our case, neurogenic tumor with spontaneous hemothorax is very rare. A 45-year-old man admitted to emergency room of other hospital because of acute right chest pain and dyspnea. A chest X-ray showed a right pleural effusion. Hemothorax was diagnosed after closed thoracostomy. Following chest CT showed posterior mediastinal mass. The patient was transferred to our hospital. T spine MRI showed dumbbell shaped mass. Diagostic impression was neurogenic tumor. The pathologic result was neurilemmoma after surgical resection.

A facile chemical synthesis of a novel photo catalyst: SWCNT/titania nanocomposite

  • Paul, Rima;Kumbhakar, Pathik;Mitra, Apurba K.
    • Advances in nano research
    • /
    • v.1 no.2
    • /
    • pp.71-82
    • /
    • 2013
  • A simple chemical precipitation technique is reported for the synthesis of a hybrid nanostructure of single-wall carbon nanotubes (SWCNT) and titania ($TiO_2$) nanocrystals of average size 5 nm, which may be useful as a prominent photocatalytic material with improved functionality. The synthesized hybrid structure has been characterized by transmission electron microscopy (HRTEM), energy-dispersive X-ray analysis (EDAX), powder X-ray diffractometry (XRD), Fourier transform infrared spectroscopy (FTIR) and Raman spectroscopy. It is clearly revealed that nearly monodispersed titania nanocrystals (anatase phase) of average size 5 nm decorate the surfaces of SWCNT bundles. The UV-vis absorption study shows a blue shift of 16 nm in the absorbance peak position of the composite material compared to the unmodified SWCNTs. The photoluminescence study shows a violet-blue emission in the range of 325-500 nm with a peak emission at 400 nm. The low temperature electrical transport property of the synthesized nanomaterial has been studied between 77-300 K. The DC conductivity shows semiconductor-like characteristics with conductivity increasing sharply with temperature in the range of 175-300 K. Such nanocomposites may find wide applications as improved photocatalyst due to transfer of photo-ejected electrons from $TiO_2$ to SWCNT, thus reducing recombination, with the SWCNT scaffold providing a firm and better positioning of the catalytic material.