• Title/Summary/Keyword: Silicone cable

Search Result 41, Processing Time 0.03 seconds

Electric Field Distribution Simulation of the Cable Joint Materials (케이블 접속재료의 전계분포 시뮬레이션)

  • 김형주;변두균;신종열;이덕진;이충호;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.601-604
    • /
    • 2001
  • The insulation materials of cables used for underground power transmission requires a higher insulating capability, and the most popular method to examine the cable is partial discharge test due to applying variation voltage. In the thesis, air void, silicone oil, of which may possibly exist real cables, are simulated by Electro 2D program. Also the relations between calculated field strength and the void defect type in the cable joint materials. In the modeling, eclectic field inner to the cable joint material composed by XLPE and EPDM is modeling simulated. We obtained the electric field distribution in void due to two conditions.

  • PDF

Improvement of Tracking Property of Silicone Rubber Used for Out-door Polymer Insulator According to Aluminium Hydrate Filler (고분자애자용(高分子碍子用) 실리콘고무 재료(材料)의 $Al(OH)_3$에 의한 Tracking성(性) 향상(向上) 연구(硏究))

  • Hahn, K.M.;Kim, D.W.;Oh, M.W.;Kweon, H.S.;Kim, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1239-1241
    • /
    • 1993
  • This paper studies on the improvement of non-tracking property which is very important matter for developing polymer insulator. Non-Tracking property of silicon rubber used for polymer insulator was investigated by ASTM D 2303 according to Aluminium Hydrate filler. Furthermore other electrical and mechanical properties were estimated. The optimum amount of Aluminium Hydrate should be considered by following test results.

  • PDF

A Study on the Ultraviolet Aging Characteristics of Outdoor Polymeric Insulating Materials (옥외용 고분자 절연재료의 자외선 열화특성 연구)

  • Kim, Yeong-Seong;Jeong, Sun-Ok
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.409-413
    • /
    • 1999
  • Recently, the polymeric insulators have been accepted in several countries for the outdoor high voltage applications. In comparison with the conventional porcelain, polymeric insulators offer various advantages such as light weight, superior vandal resistance and better contamination performance. The outdoor polymeric insulating materials such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged under the various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-under the various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-ray on the surface of silicone rubber were investigated by using the weather-Ometer. The accelerated aging stresses were simulated by UV radiation, high temperature and humidity as well as water spray. These aging characteristics were examined through contact angle measurements, tracking resistance test, FT-IR and SEM/EDS analysis. The experimental results showed that tracking resistance decreases with increase in the UV-ray irradiation period. But the surface of silicone rubber kept hydrophobicity. It is found that the inorganic filler such as)$ Al(OH_3$ improves tracking resistance and the $Tio_2$is very effective in preventing degradation of silicone rubber surface from UV-ray.

  • PDF

Breakdown characteristics with temperature variation on XLPE 6.9kV cable insulator at power plants (발전소 6.9kV급 XLPE 케이블 절연재의 온도에 따른 절연파괴 특성분석)

  • Park, Noh-Joon;Yang, Sang-Hyun;Lee, Ki-Joung;Kong, Tae-Sik;Kim, Hee-Dong;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.79-79
    • /
    • 2010
  • In this paper, we present results of the dielectric breakdown test in various 6.9kV power cables used in power plants. The dielectric strength of the different conditioned cables was measured by placing the sliced cable sections in silicone oil bath with needle electrode. The results were analyzed by the Weibull distribution. The shape and scale parameters of the Weibull distribution for each cable sections under test were calculated and evaluated. Collected data base was applied to deterioration trend analysis and lifetime guide was also proposed.

  • PDF

Tracking and erosion resistance of polymer for outdoor high voltage insula (초고압 옥외 절연용 고분자 재료의 트래킹 열화특성)

  • Han, Dong-Hee;Park, Hoy-Yul;Kang, Dong-Pil;Kim, In-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1578-1580
    • /
    • 1999
  • Silicone rubber is being used for the housing material of outdoor high voltage insulators such as composite insulator, bushing, surge arrestor and cable terminator because of good tracking and erosion resistance, good hydrophobicity and recovery of hydrophobicity, and chemical stability. In this paper, tracking and erosion resistance of silicone rubber having fluids and different ATH contents were examined. Fluids were selected under the consideration of their molecular weight and chemical structure, expecting the high migration rate, the good pollutant encapsulation, and the long period with good hydrophobicity. Good tracking and erosion resistance and arc resistance have been achieved for the silicone rubber above ATH content 130 phr.

  • PDF

Effect of Surface Charge in Hydrophobicity of Insulating Material and Decay of Surface Voltage after Corona Charging

  • Huh, Chang-Su;Youn, Bok-Hee;Seo, You-Jin;Hwang, Sun-Mook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.1-5
    • /
    • 2003
  • This paper presented the effects of accumulation of surface charges on hydrophobicity level and the surface states of silicone polymer used for outdoor insulator treated by ultraviolet irradiation and corona discharge through measuring surface voltage decay of a corona-charged specimen were investigated. The surface resistivity by the method of the surface potential decay was compared with the value by the three electrodes methods. From this study, it was found that the accumulation of surface charges above a critical surface voltage on silicone insulating materials could lead to the temporary loss of surface hydrophobicity. In addtion, uv stress lead to a longer decay time of surface charges. We could conclude that the effects of surface charges on hydrophocity level and the changes of surface state by various artificial treatments were understood through a trend of surface potential decay.

  • PDF

A Possible Sunlight Effect on the Aging Characteristics of Silicone Rubber used for Outdoor Insulation (태양광 모의 열화에 의한 옥외용 실리콘 고무의 열화특성에 관한 연구)

  • Lim, C.R.;Lee, J.H.;Kim, J.T.;Koo, J.Y.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1276-1278
    • /
    • 1998
  • In this paper, aging characteristics of silicone rubber used for outdoor insulation have been investigated with regards to sunlight effect. For this purpose, silicone rubbers were aged under the artificial sunlight by use of xenon arc lamp(1500W) and various tests were performed such as tracking, breakdown, contact angle, stress, strain. And then, in order to elucidate the changes of material, analysis have been followed as follows; FT-IR, SEM and EDS. Regarding the effect of the sunlight, it was obs that the surface of test samples are severely da with decreased hydrophobicity, tracking resistan breakdown strength.

  • PDF

Degradation of Silicone Rubber Used as Outdoor Insulator Under Accelerated Weathering Condition (자외선 가속열화에 따른 전력용 실리콘 절연재료의 열화평가)

  • Youn, B.H.;Bai, K.M.;Lee, S.J.;Paek, J.H.;Kim, S.W.;Jeon, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1906-1908
    • /
    • 2004
  • 본 논문은 옥외용 고분자 절연물로 널리 사용되고 있는 실리콘 고무의 장기 자외선 가속열화에 따른 특성변화를 조사하였다. 이를 위해 전기적인 평가 방법 이외에 각종 화학적 분석기기를 사용하여 보다 정확히 재료의 열화를 판정하고자 하였다. 연구결과, 실리콘 고무는 내후성이 우수하지만, 가속열화가 진행되면서 표면의 전기적 저항률이 높아지고, 전하축적이 용이해지는 표면구조로 변하는 것을 확인하였다. 또한, 재료 내에서 발수성 회복역할을 하는 저분자량 성분이 감소하였고, 열적특성이 변화되는 것을 확인하였다. 이를 통하여, 최근 확산되고 있는 옥외용 고분자 절연물의 성능평가 및 수명예측에 도움이 되고자 하였다.

  • PDF

A Study on Partial Discharge Degradation Properties of PVC Cable due to NaCl (NaCl에 의한 PVC 케이블의 부분방전 열화 특성에 관한 연구)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.10
    • /
    • pp.636-641
    • /
    • 2015
  • In this study, the partial discharge degradation properties for 2-core PVC cable($2cores{\times}1.5mm^2$ cross section, length of 10 cm, 20 cm, 30 cm) following immersion with the salt water that the 2%, 4%, 8% of NaCl is dissolved in 100 g of distilled water for 48 and 96 hours has been measured. The results of this study are as follows. When the degradation time in salt water of 2% NaCl is 48 hours, it found that the number of partial discharge increased as about 40 pps, 50 pps, 90 pps with increasing the length of cable to 10 cm, 20 cm, 30 cm. In case the concentration and degradation time is same, the inception and extinction voltage decreased with increasing the length of cable. When the degradation time in salt water is 96 hours and the length of cable is 20 cm, it found that the number of partial discharge decreased as 3,000 pps, 500 pps, 100 pps with increasing the concentration of NaCl to 2%, 4%, 8%.

Aging Diagnosis of Underground Distribution Power Cables by Isothermal Relaxation Current Measurement Equipment (완화전류 측정에 의한 지중배전케이블의 열화진단)

  • Kim, Ju-Yong;Song, Il-Keun;Kim, Dong-Myung;Yun, Tae-Sang;Jeong, Sang-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.502-505
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this papar we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

  • PDF