• 제목/요약/키워드: Silicon rubber

검색결과 120건 처리시간 0.034초

BB Pellet 재질에 따른 안구 손상 위험성에 관한 실험적 연구 (Experimental Studies on Eye Injury Risks by Different BB Pellet Materials)

  • 김형석;박달재
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.20-24
    • /
    • 2012
  • Experimental studies were performed to investigate the eye injury risks by different BB pellet materials. Four different BB pellet materials were used: plastic (P), silicon (S), rubber (R) and plastic covered with silicon (SR). The BB pellet images penetrating into the gelatine simulant were recorded by a high-speed video camera. The results obtained from the different pellet materials were discussed in terms of impact velocity and penetration depth; threshold velocity and projectile sectional density; eye injury risks by normalized energies. It was found that the P pellets caused higher impact velocity while the lower was SR pellets. The penetration depth and threshold velocity of the pellets were dependent on the impact velocity of the pellets, and the P pellets resulted in the higher eye injury risk while the lower was SP.

INVESTIGATIONS ON THREE-BODY ABRASIVE WEAR BEHAVIOUR OF SILICON CARBIDE AND GRAPHITE FILLED GLASS-VINYL ESTER COMPOSITES

  • Suresha, B.;Chandramohan, G.;Siddaramaiah, Siddaramaiah;Lee, Joong- Hee
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.148-153
    • /
    • 2007
  • The effect of silicon carbide (SiC) and graphite fillers incorporation on the abrasive wear behaviour of glass-vinyl ester (G-V) composites have been investigated. The three-body abrasive wear behaviour was assessed by rubber wheel abrasion tests (RWAT). The worn surfaces were examined using scanning electron microscopy (SEM). The addition of SiC and graphite fillers in G-V composite improves the abrasion resistance under different loads/abrading distances. The SEM studies indicate the reasons for failure of composites and influencing parameters.

  • PDF

약물 전달용 전자력 마이크로 밸브의 설계 및 제작 (Design, Fabrication of Electromagnetic Microvalve for Drug Delivery Systems)

  • 임인호;이기정;윤현중;심우영;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1526-1527
    • /
    • 2007
  • This paper presents the design, fabrication and experimental results of an electromagnetic microvalve for drug delivery systems. The microvalve consists of two silicon substrates with a silicone rubber diaphragm and a flow channel, a PDMS layer, and an electromagnetic actuator. Each substrate is fabricated by using the silicon wet etch, SU-8 mold process and $O_2$ plasma bonding.

  • PDF

압력과 온도측정 기능을 갖는 고성능 플렉시블 촉각센서 (High-Performance Multimodal Flexible Tactile Sensor Capable of Measuring Pressure and Temperature Simultaneously)

  • 장진석;강태형;송한욱;박연규;김민석
    • 한국정밀공학회지
    • /
    • 제31권8호
    • /
    • pp.683-688
    • /
    • 2014
  • This paper presents a high-performance flexible tactile sensor based on inorganic silicon flexible electronics. We created 100 nm-thick semiconducting silicon ribbons equally distributed with 1 mm spacing and $8{\times}8$ arrays to sense the pressure distribution with high-sensitivity and repeatability. The organic silicon rubber substrate was used as a spring material to achieve both of mechanical flexibility and robustness. A thin copper layer was deposited and patterned on top of the pressure sensing layer to create a flexible temperature sensing layer. The fabricated tactile sensor was tested through a series of experiments. The results showed that the tactile sensor is capable of measuring pressure and temperature simultaneously and independently with high precision.

THE NEW TYPE BROAD BEAM ION SOURCES AND APPLICATIONS

  • You, D.W.;Feng, Y.C.;Wang, Y.;Kuang, Y.Z.
    • 한국진공학회지
    • /
    • 제4권S2호
    • /
    • pp.131-138
    • /
    • 1995
  • The broad beam ion sources of hot filament plasma type have widely used for modifications of materials and thin films, and the new type intensive current broad beam metal ion source including reactive gaseous ion beams is needed for preparing the hard coating films such as DLC, $\beta-C_3N_4$ Carbides, Nitrides, Borides etc. Now a electorn beam evaporation(EBE) broad beam metal ion source has been developed for this purpose in our lab. CN film has been formed by the EBE ion source. Study of the CN film shows that it has high hardness(HK=5800kgf/$\textrm {mm}^2$)and good adhesion. This method can widely changes the ratio of C/N atom's concentrations from 0.14 to 0.6 and has high coating rate. The low energy pocket ion source which was specially designed for surface texturing of medical silicon rubber was also developed. It has high efficiency and large uniform working zone. Both nature texturing and mesh masked texturing of silicon rubbers were performed. The biocompatibility was tested by culture of monocytes, and the results showed improved biocompatibility for the treated silicon rubbers. In addition, the TiB2 film synthesized by IBED is being studied recently in our lab. In this paper, the results which include the hardness, thickness of the films and the AES, XRD analysis as well as the tests of the oxidation of high temperature and erosion will be presented.

  • PDF

의치상(義齒床) 개선(改選)에 관한 연구(硏究) (A Study on the Improvement of Denture Base construction)

  • 신무학
    • 대한치과기공학회지
    • /
    • 제14권1호
    • /
    • pp.133-138
    • /
    • 1992
  • The base of a metal base denture that is made of acrylic resin base and metal in lined by soft liner named silicon rubber and its merits are as follows. 1. It has a good retention and fastness. 2. It has a good comfort and stability. 3. It is easy to mix various kinds of base materials. 4. It is easy to repair. 5. The pressure of bone and mucosal tissue is decreased and bite force is dispersed.

  • PDF

흑연과 실리콘 일산화물의 혼합물로 구성된 리튬이온 이차전지용 음극의 사이클 성능개선 연구 (Improvement of Cycle Performance of Graphite-Silicon Monoxide Mixture Negative Electrode in Lithium-ion Batteries)

  • 김해빈;김태훈;류지헌
    • 전기화학회지
    • /
    • 제22권4호
    • /
    • pp.155-163
    • /
    • 2019
  • 우수한 수명특성을 지니는 흑연과 높은 용량을 지니고 있는 실리콘 일산화물의 혼합전극을 제조하여 리튬이온 이차전지용 음극으로 적용하여 이의 사이클 성능에 대하여 평가하였다. 천연흑연과 실리콘 일산화물을 9:1의 질량비로 혼합하여 제조한 전극은 $480mAh\;g^{-1}$의 가역용량으로 천연흑연에 비하여 33% 이상의 높은 용량을 나타내었다. 그러나, 실리콘 일산화물의 부피변화로 인하여 용량의 퇴화가 지속적으로 발생하였다. 본 연구에서는 전극 및 전해질의 구성에 변수들을 적용하여 각각의 변수가 영향을 주는 전기화학적 특성을 파악하고 이를 통하여 사이클 수명을 향상시킬 수 있는 방안을 모색하고자 하였다. 전극 제조 시에 poly(vinylidene fluoride)(PVdF) 바인더에 비하여 carboxymethyl cellulose (CMC) 바인더는 가장 우수한 사이클 특성을 나타내었으며, CMC와 styrene-butadiene rubber (SBR)을 함께 사용하는 SBR/CMC 바인더의 경우에는 CMC 단독 바인더를 사용하는 경우와 유사한 사이클 특성과 동시에 속도특성에서 장점을 지니고 있었다. 전해액 첨가제로 fluoroethylene carbonate (FEC)를 적용하는 경우에 수명특성이 크게 개선되었다. FEC의 함량이 10 질량%로 높아지게 되면 전지의 속도특성이 저하되기 때문에 5 질량%의 사용이 적절하였다. 또한 전극의 로딩값을 낮추게 되면 사이클 특성을 크게 향상시킬 수 있었으며, 집전체를 사포로 연마하여 거칠기를 증가시키는 것도 사이클 특성의 개선을 가져올 수 있었다.

발변전용 피뢰기의 구조 및 ZnO 바리스터 소자의 전기적 특성 (Structure of Station Class Lightning Arresters and Electrical Characteristics of ZnO Varistor Blocks)

  • 조한구;한세원;이운용;윤한수;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1158-1161
    • /
    • 2004
  • This paper presents structural characteristics of station class lightning arresters and electrical characteristics of manufactured ZnO varistor blocks which are usable in those arresters. Three types of station class lightning arresters were investigated and those are a ceramic arrester, a FRP tube type polymer arrester, and a FRP rod type polymer arrester. Each arrester has merits and demerits with structural characteristics. In general, polymer arresters were made of silicon rubber for housing materials, FRP tube or rod for mechanical strength, ZnO blocks for electrical characteristics, and metal parts for electrical contact and the silicon rubber, the housing materials, was directly injected to the arrester module which was assembly composed of electrodes, ZnO blocks and FRP tube or rod, and to prevent the nonlinear electric fields distribution on upper parts of arresters, the grade ring was adopted to the upper electrodes. The reference voltage, nonlinear coefficient, residual voltage, and voltage ratio of manufactured ZnO varistors are 4.90kV, 50, 9.54kV, 1.94, respectively. Compared to designed electrical characteristics, the reference voltage was low for 600v and the voltage ratio was slightly high. However, the characteristics of discharge withstand was so excellent that the mechanical destruction does not occur at the impulse current of $8/20{\mu}s$ 10kA for 100 times.

  • PDF

혼합 Bacillus sp. BOD 센서 (Mixed Bacillus sp. BOD sensor)

  • 강태영;박현주;박경량;김진두;차근식;남학현
    • 분석과학
    • /
    • 제20권1호
    • /
    • pp.1-9
    • /
    • 2007
  • 용존산소(dissolved oxygen; DO) 전극에 미생물 막과 보호막을 장착하여 BOD(biochemical oxygen demand) 센서를 제작하였다. 토양과 물 그리고 활성슬러지에서 분리한 다양한 미생물들을 BOD 센서에 적용하여 그 감응특성을 조사하여 빠른 산소 호흡력과 회복력을 나타내는 미생물로 Bacillus 종인 HN24와 HN93을 선별하였다. 최종적으로 최적화한 BOD 센서는 Bacillus subtilis, Bacillus sp. HN24 그리고 Bacillus sp. HN93을 혼합한 미생물 막과 DO 전극의 기체투과막을 silicon rubber(SR) 막으로 사용한 것이며, 측정조건으로 완충용액에 50% 산소(질소와의 비율)를 주입하여 감응특성을 향상시켰다. 본 실험에서 제작된 BOD 센서는 100 mg/L BOD 농도 이상까지 우수한 직선감응성($r^2=0.9986$)을 나타냈다.