• Title/Summary/Keyword: Signal converter

Search Result 944, Processing Time 0.025 seconds

Modeling of Wavelength Conversion Charateristics in Directionally Coupled Semiconductor Optical Amplifier (반도체 광증폭기로 형성된 방향성 결합기에서의 파장변환 특성 모델링)

  • Chung, Ho-Young;Chung, Young-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.8
    • /
    • pp.43-53
    • /
    • 2001
  • Wavelength conversion devices are essential to build an expanding all-optical network, and various types of wavelength conversion techniques are being researched. Among them, wavelength conversion based on the cross phase modulation in a directionally coupled semiconductor optical amplifier has been introduced and the concept has been experimentally proved. In this paper, a split-step method is applied to properly model the mentioned wavelength converter in the time-domain and various characteristics have been analyzed. It is shown that the present modeling approach can explain the results of the reported experimental results. Furthermore the wavelength conversion is shown to be well performed when the input signal wave and the converted wave travels in the opposite direction. The simulation shows that the positive and negative chirping appear simultaneously at both the leading and trailing of edges of the optical pulse.

  • PDF

Configuration of ETDM 20 Gb/s optical transmitter / receiver and their characteristics (전기적 시분할 다중 방식을 이용한 20 Gb/s 광송,수신기의 제작 및 성능 평가)

  • Lim, Sang-Kyu;Cho, Hyun-Woo;Lyu, Gap-Youl;Lee, Jong-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.295-300
    • /
    • 2002
  • We developed an optical transmitter and receiver for an electrical time division multiplexed (ETDM) 20 Gb/s optical transmission system, and experimentally investigated their characteristics. Especially, the clock extraction circuit, which is a key component in realizing broadband optical transmission receivers, was realized by using an NRZ-to-PRZ converter implemented with a half-period delay line and an EX-OR, a high-Q bandpass filter using a cylindrical dielectric resonator, and a microstrip coupled-line bandpass filter. Finally, the bit-error-rate of demultiplexed 10 Gb/s electrical signal after back to-back transmission was measured, and a high receiver sensitivity [-26.2 dBm for NRZ ($2^{7}-1$) pseudorandom binary sequence (PRBS)] was obtained

Measurement of Cardiac Pulse Transit Time using Photoplethysmography Sensor (광전용적맥파 센서를 이용한 맥파전달시간의 측정)

  • Choi, Byeong-Cheol;Jung, Dong-Keun;Jeong, Do-Un;Ro, Jung-Hun;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.383-391
    • /
    • 2004
  • In this study, we implemented the pulse transit time (PTT) system to examine usefulness of the monitoring method of distensibility and elasticity using photoplethysmography sensor in vivo. PTT is defined as the time interval between the peak of QRS complex in ECG signal and the maximum slope point of photoplethysmography. these two signals were converted to digital data by means of AID converter, then PTT was evaluated by heartbeat using PC. Results of analysis were displayed as a graph using spline interpolation method. The variance of PTT was measured repetitiously to verify efficiency of PTT system in resting state and hyperemic state. Repeated measurement of PTT was not same value but showed that coefficients of correlation were related with each other as 0.8302 (P<0.01) in resting state. And also repeated measurement of PTT showed significant correlation as 0.868 (P<0.01) in the hyperemic state. These result showed that PTT is reflect on transient pressure variance in the artery and is very useful method for the evaluation of prognosis of the hypertension and arteriosclerosis.

Front-End Module of 18-40 GHz Ultra-Wideband Receiver for Electronic Warfare System

  • Jeon, Yuseok;Bang, Sungil
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.3
    • /
    • pp.188-198
    • /
    • 2018
  • In this study, we propose an approach for the design and satisfy the requirements of the fabrication of a small, lightweight, reliable, and stable ultra-wideband receiver for millimeter-wave bands and the contents of the approach. In this paper, we designed and fabricated a stable receiver with having low noise figure, flat gain characteristics, and low noise characteristics, suitable for millimeter-wave bands. The method uses the chip-and-wire process for the assembly and operation of a bare MMIC device. In order to compensate for the mismatch between the components used in the receiver, an amplifier, mixer, multiplier, and filter suitable for wideband frequency characteristics were designed and applied to the receiver. To improve the low frequency and narrow bandwidth of existing products, mathematical modeling of the wideband receiver was performed and based on this spurious signals generated from complex local oscillation signals were designed so as not to affect the RF path. In the ultra-wideband receiver, the gain was between 22.2 dB and 28.5 dB at Band A (input frequency, 18-26 GHz) with a flatness of approximately 6.3 dB, while the gain was between 21.9 dB and 26.0 dB at Band B (input frequency, 26-40 GHz) with a flatness of approximately 4.1 dB. The measured value of the noise figure at Band A was 7.92 dB and the maximum value of noise figure, measured at Band B was 8.58 dB. The leakage signal of the local oscillator (LO) was -97.3 dBm and -90 dBm at the 33 GHz and 44 GHz path, respectively. Measurement was made at the 15 GHz IF output of band A (LO, 33 GHz) and the suppression characteristic obtained through the measurement was approximately 30 dBc.

Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System (패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극)

  • Lee, Jeong Su;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.203-210
    • /
    • 2014
  • Wearable medical device has been a resurgence of interest thanks to the development of technology and propagation of smart phone in recent years. Various types of wearable devices have been introduced and available in market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearable device. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrode to body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram (ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system be adhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-to-digital converter and wireless transmission module and designed to be attached on the body as a patch. To validate the feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethane and adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoring in real-life.

Design and Implementation of the RF Systems for Bi-directional Wireless Capsule Endoscopes

  • Moon, Yeon-Kwan;Lee, Jyung-Hyun;Park, Hee-Joon;Lee, Ju-Gab;Ryu, Jae-Jong;Lee, Wu-Seong;Woo, Sang-Hyo;Won, Chul-Ho;Cho, Jin-Ho;Choi, Hyun-Chul
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.12
    • /
    • pp.1669-1680
    • /
    • 2006
  • This paper explains that the RF systems for hi-directional wireless capsule endoscopes were designed and implemented. The designed RF systems for a capsule endoscope can transmit the images of intestines from the inside to the outside of a body and the behavior of the capsules can be controlled by an external controller simultaneously. The hi-directional wireless capsule endoscope consists of a CMOS image sensor, FPGA, LED, battery, DC to DC Converter, transmitter, receiver, and antennas. The transmitter and receiver which were used in the hi-directional capsule endoscope, were designed and fabricated with $10mm(diameter){\times}3.2mm(thickness)$ dimensions taking into the MPE, power consumption, system size, signal to noise ratio and modulation method. The RF systems designed and implemented for the hi-directional wireless capsule endoscopes system were verified by in-vivo experiments. As a result, the RF systems for the hi-directional wireless capsule endoscopes satisfied the design specifications.

  • PDF

An Enhancement of Speaker Location System Using the Low-frequency Phase Restoration Algorithm and Its Implementation (저주파 위상 복원 알고리듬을 이용한 화자 위치 추적 시스템의 성능 개선과 구현)

  • 이학주;차일환;윤대희;이충용
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.22-28
    • /
    • 2001
  • This paper describes the implementation of a robust speaker position location system using the voice signal received by microphone array. To be robust to the reverberation which is the major factor of the performance degradation, low-frequency phase restoration algorithm which eliminates the influence of reverberations using the low-frequency information of the CPSP function is proposed. The implemented real-time system consists of a general purpose DSP (TMS320C31 of Texas instruments), analog part which contains amplifiers and filters, and digital part which is composed of the external memory and 12-bit A/D converter. In the real conference room environment, the implemented system that was constructed by the proposed algorithms showed better performance than the conventional system. The error of the TDOA estimation reduced more than 15 samples.

  • PDF

Development of High Speed Peak-hold Circuit for Gamma-ray (감마선용 고속 피크홀드회로의 개발)

  • Choi, Ki-seong;Che, Gyu-shik
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.6
    • /
    • pp.612-616
    • /
    • 2016
  • Gamma-ray must be detected and processed immedietely after generation of it in the circumstances where it exists. Software methology may be used to process randomly generated signals, but its memory size and processing time become large. By the way, the hardware circuit to detect randomly generated signals is generalized in industrial site, while those circuits are not able to answer to the cases whose amplitude are very small and also speed high. We researched and developed hardware based peak-hold circuit that is able to detect peaks of gamma-ray signals through direct reading out their values by ADC at the time of maximum reaching for the small amplitude and high speed signals, and proposed and estimated its results in this paper. This peak-hold circuit is adequate to use in the radiation circumstances in which the gamma-rays are heavy because its circuit can catch high speed signals efficiently without software signal processing supports.

The Performance Improvement of a Linear CCD Sensor Using an Automatic Threshold Control Algorithm for Displacement Measurement

  • Shin, Myung-Kwan;Choi, Kyo-Soon;Park, Kyi-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1417-1422
    • /
    • 2005
  • Among the sensors mainly used for displacement measurement, there are a linear CCD(Charge Coupled Device) and a PSD(Position Sensitive Detector) as a non-contact type. Their structures are different very much, which means that the signal processing of both sensors should be applied in the different ways. Most of the displacement measurement systems to get the 3-D shape profile of an object using a linear CCD are a computer-based system. It means that all of algorithms and mathematical operations are performed through a computer program to measure the displacement. However, in this paper, the developed system has microprocessor and other digital components that make the system measure the displacement of an object without a computer. The thing different from the previous system is that AVR microprocessor and FPGA(Field Programmable Gate Array) technology, and a comparator is used to play the role of an A/D(Analog to Digital) converter. Furthermore, an ATC(Automatic Threshold Control) algorithm is applied to find the highest pixel data that has the real displacement information. According to the size of the light circle incident on the surface of the CCD, the threshold value to remove the noise and useless data is changed by the operation of AVR microprocessor. The total system consists of FPGA, AVR microprocessor, and the comparator. The developed system has the improvement and shows the better performance than the system not using the ATC algorithm for displacement measurement.

  • PDF

A Digital Automatic Gain Control Circuit for CMOS CCD Camera Interfaces (CMOS CCD 카메라용 디지털 자동 이득 제어 회로)

  • 이진국;차유진;이승훈
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.5
    • /
    • pp.48-55
    • /
    • 1999
  • This paper describes automatic gain control circuit (AGC) design techniques for CMOS CCD camera interface systems. The required gain of the AGC in the proposed system is controlled directly by digital bits without conventional extra D/A converters and the signal settling behavior is almost independent of AGC gain variation at video speeds. A capacitor-segment combination technique to obtain large capacitance values considerably improves the effective bandwidth of the AGC based on switched-capacitor techniques. A proposed layout scheme for capacitor implementation shows AGC matching accuracy better than 0.1 %. The outputs from the AGC are transferred to a 10b A/D converter integrated on the same chip. The proposed AGC is implemented as a sub-block of a CCD camera interface system using a 0.5 um n-well CMOS process. The prototype shows the 32-dB AGC dynamic range in 1/8-dB steps with 173 mW at 3 V and 25 MHz.

  • PDF