• Title/Summary/Keyword: Signal Phase Shift

Search Result 304, Processing Time 0.019 seconds

Audio /Speech Codec Using Variable Delay MDCT/IMDCT (가변 지연 MDCT/IMDCT를 이용한 오디오/음성 코덱)

  • Sangkil Lee;In-Sung Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.2
    • /
    • pp.69-76
    • /
    • 2023
  • A high-quality audio/voice codec using the MDCT/IMDCT process can perfectly restore the current frame through an overlap-add process with the previous frame. In the overlap-add process, an algorithm delay equal to the frame length occurs. In this paper, we propose a MDCT/IMDCT process that reduces algorithm delay by using a variable phase shift in MDCT/IMDCT process. In this paper, a low-delay audio/speech codec was proposed by applying the low delay MDCT/IMDCT algorithm to the ITU-T standard codec G.729.1 codec. The algorithm delay in the MDCT/IMDCT process can be reduced from 20 ms to 1.25 ms. The performance of the decoded output signal of the audio/speech codec to which low-delay MDCT/IMDCT is applied is evaluated through the PESQ test, which is an objective quality test method. Despite of the reduction in transmission delay, it was confirmed that there is no difference in sound quality from the conventional method.

A GaAs MMIC Multi-Function Chip with a Digital Serial-to-Parallel Converter for an X-band Active Phased Array Radar System (X-대역 능동 위상 배열 레이더 시스템용 디지털 직병렬 변환기를 포함한 GaAs MMIC 다기능 칩)

  • Jeong, Jin-Cheol;Shin, Dong-Hwan;Ju, In-Kwon;Yom, In-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.6
    • /
    • pp.613-624
    • /
    • 2011
  • An MMIC multi-function chip for an X-band active phased array radar system has been designed and fabricated using a 0.5 ${\mu}m$ GaAs p-HEMT commercial process. A digital serial-to-parallel converter is included in this chip in order to reduce the number of the control interface. The multi-function chip provides several functions: 6-bit phase shifting, 6-bit attenuation, transmit/receive switching, and signal amplification. The fabricated multi-function chip with a relative compact size of 24 $mm^2$(6 mm${\times}$4 mm) exhibits a transmit/receive gain of 24/15 dB and a P1dB of 21 dBm from 8.5 GHz to 10.5 GHz. The RMS errors for the 64 states of the 6-bit phase shift and attenuation were measured to $7^{\circ}$ and 0.3 dB, respectively over the frequency.

Hybrid Two-Dimensional Proton Spectroscopic Imaging of Pediatric Brain: Clinical Application (소아 뇌에서의 혼성 이차원 양성자자기공명분광법의 임상적 응용)

  • Sung Won Youn;Sang Kwon Lee;Yongmin Chang;No Hyuck Park;Jong Min Lee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.64-72
    • /
    • 2002
  • Purpose : To introduce and demonstrate the advantages of the new hybrid two-dimensional (2D) proton spectroscopic imaging (SI) over the single voxel spectroscopy (SVS) and conventional 2D SI in the clinical application of spectroscopy for pediatric cerebral disease. Materials and Methods : Eighty-one hybrid 2D proton spectroscopic imaging was performed in 79 children (36 normal infants and children, 10 with hypoxic-ischemic injury, 20 with toxic-metabolic encephalopathy, seven with brain tumor, three with meningoencephalitis, one with neurofibromatosis, one with Sturge-Weber syndrome and one with lissencephaly) ranging in age from the third day of life to 15 years. In adult volunteers (n=5), all three techniques including hybrid 2D proton SI, SVS using PRESS sequence, and conventional 2D proton SI were performed. Both hybrid 2D proton SI and SVS using PRESS sequence were performed in clinical cases (n=). All measurements were performed with a 1.5-T scanner using standard head quadrature coil. The 16$\times$16 phase encoding steps were set on variable field of view (FOV) depending on the size of the brain. The hybrid volume of interest inside FOV was set as $75{\times}75{\times}15{\;}\textrm{mm}^3$ or smaller to get rid of unwanted fat signal. Point-resolved spectroscopy (TR/TE=1,500 msec/135 or 270msec) was employed with standard chemical shift selective saturation (CHESSI pulses for water suppression. The acquisition time and spectral quality of hybrid 2D proton SI were compared with those of SVS and conventional 2D proton SI. Results : The hybrid 2D proton SI was successfully conducted upon all patients.

  • PDF

CACB-Q2PSK Modulation for Efficient Bandwidth Utilization and Constant Amplitude Signal Transmission (효율적인 대역폭 이용과 정진폭 신호 전송을 위한 CACB-Q2PSK 변조)

  • Hong, Dae-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.93-99
    • /
    • 2008
  • In this paper, we propose new modulation schemes using the conventional CACB modulation with constant amplitude property. Also the proposed modulation schemes supports high transmission data rate by increasing the spectral efficiency. In order to obtain the high spectral efficiency, the $Q^2$PSK and CA-$Q^2$PSK are used. We explain the simplest combining modulation scheme of CACB and $Q^2$PSK (i.e., CACB-$Q^2$PSK). However, this modulation scheme cannot support the constant amplitude property. Hence the first CACB-CA-$Q^2$PSK (or CACB-CA-$Q^2$PSK I) modulation scheme is proposed for the constant amplitude property. In the modulation scheme, the redundant constant amplitude encoding (spectral efficiency decrease) is required. Therefore, the second CACB-CA-$Q^2$PSK (or CACB-CA-$Q^2$PSK II) modulation scheme is proposed retaining the constant amplitude and the spectral efficiency. Computer simulations show that the proposed CACB-CA-$Q^2$PSK II is the efficient modulation scheme.