• 제목/요약/키워드: Side leakage loss

검색결과 39건 처리시간 0.029초

MIDLOOP Code Analysis of a ROSA-IV/LSTF Experiment for the Loss of Residual Heat Removal System Event During Mid- loop Operation

  • Han, Kee-Soo;Lee, Cheol-Sin;Park, Chul-Jin;Kim, Hee-Cheol
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.683-690
    • /
    • 1996
  • The MIDLOOP code has been developed for the evaluation of RES pressurization transients initiated from a loss-of-Residual Heat Removal System (RHRS) during mid-loop operation after reactor shutdown. It provides a fast running and realistic tool for studying parametrically the response of important plant parameters such as pressure, temperature, and level to various plant combinations of the primary side vent, makeup, and leakage procedures and the steam generator (SG) conditions. The code consists of ten nodes representing the primary and secondary sides of a nuclear power plant and can analyze the effect of air on the primary system pressurization and primary to secondary heat transfer. The analysis results of the MIDLOOP code are in good agreement with the ROSA-IV/LSTF experiment without opening in the RCS.

  • PDF

재생펌프의 성능 특성에 관한 실험적 연구 (Performance Characteristic of Regenerative Pumps)

  • 임형수;강신형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.361-366
    • /
    • 2003
  • For regenerative pump performance test we made 5 times enlarged and 3 different kinds blade types impeller with similarity. Due to geometrical characteristic of regenerative pump, there are two kinds of groups which effect on performance of it. One is geometric shape of impeller blade and the other is clearance and inlet/outlet head loss. To study performance of regenerative pump with impeller shape changes, we tested it with reducing clearance. And we reconcile performance data in the case of zero clearance and zero inlet/outlet head loss. Finally we could verify the influence of each group.

  • PDF

중수로 원전 교류전원 완전상실 사고 시 일차측 열수송 펌프 밀봉 누설 영향에 대한 코드 분석 (Code Analysis of Effect of PHTS Pump Sealing Leakage during Station Blackout at PHWR Plants)

  • 유선오;조민기;이경원;백경록
    • 한국압력기기공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.11-21
    • /
    • 2020
  • This study aims to develop and advance the evaluation technology for assessing PHWR safety. For this purpose, the complete loss of AC power or station blackout (SBO) was selected as a target accident scenario and the analysis model to evaluate the plant responses was envisioned into the MARS-KS input model. The model includes the main features of the primary heat transport system with a simplified model for the horizontal fuel channels, the secondary heat transport system including the shell side of steam generators, feedwater and main steam line, and moderator system. A steady state condition was achieved successfully by running the present model to check out the stable convergence of the key parameters. Subsequently, through the SBO transient analyses two cases with and without the coolant leakage via the PHTS pumps were simulated and the behaviors of the major parameters were compared. The sensitivity analysis on the amount of the coolant leakage by varying its flow area was also performed to investigate the effect on the system responses. It is expected that the results of the present study will contribute to upgrading the evaluation technology of the detailed thermal hydraulic analysis on the SBO transient of the operating PHWRs.

지하공간에서의 이동통신 셀 설계에 관한 연구 (Optimized Design of Mobile Communication Antenna In the Underground Area)

  • 오성균
    • 대한전자공학회논문지TC
    • /
    • 제45권1호
    • /
    • pp.27-32
    • /
    • 2008
  • 전파가 도달하지 않는 지하 공간에서는 전파를 중계해주는 중계기가 필요하고, 전파를 방사하기 위한 안테나가 필요하다. 지하공간에서 방사 형태에 따라 안테나 방식과 LCX(Leakage Coxial Cable)방식 또는 RCX(Radiax Coaxcial cable)의 두 종류가 있으며, 설치환경 및 주파수 등 용도에 따라 선택이 틀려질 수 있다. 일반적으로 이동통신에서 주로 많이 사용 되고있는 주파수가 비교적 높은(500MHz대역이상)에서는 안테나 방식을 적용하고, FM, T-DMB, 소방무선, 지하철 자가통신망 등 주파수가 낮은 대역(500MHz이하)에서는 LCX방식을 적용하는 것이 효율적이라고 볼수 있다. 중계망의 설계는 자유공간손실, LCX의 결합/전송 손실의 이론 바탕에서 셀 설계를 할 수 있으며, 무엇보다 필드에서의 실측 실험치의 데이터에 의하여 셀 설계가 가장 현실에 적용하기 적합한 방법이라고 할 수 있다.

배전급 피뢰기용 ZnO 바리스터 소자의 미세구조 및 서지 특성에 관한 연구 (A Study on the microstructure and Surge Characteristics of ZnO varistors for distribution Arrester)

  • 김석수;조한구;박태곤;박춘현;정세영;김병규
    • 한국전기전자재료학회논문지
    • /
    • 제15권2호
    • /
    • pp.190-197
    • /
    • 2002
  • In this thesis, ZnO varistors with various formulation, such as A∼E, were fabricated according to ceramic fabrication method. The microstructure, electrical properties, and surge characteristics of ZnO varistors were investigated according to ZnO varistors with various formulation. In the microstructure, A∼E\`s ZnO varistor ceramics sintered at 1130$\^{C}$ was consisted of ZnO grain(ZnO), spinel phase (Zn$\_$2.33/Sb$\_$0.67/O$\_$4/), Bi-rich phase(Bi$_2$O$_3$) and intergranuler phase, wholly. Lightning impulse residual voltage of A, B, C and E\`s ZnO varistors suited standard characteristics, below 12kV at current of 5kA. On the contrary, D\`s ZnO varistor exhibited high residual voltage as high reference voltage. In the accelerated aging test, leakage current and watt loss of B, C and D\`s ZnO varistors increases abruptly with stress time under the first a.c. stress(115$\^{C}$/3.213kV/300h). Consequently, C varistor exhibited a thermal run away. On the contrary, leakage current and watt loss of A and C\`s ZnO varistors which show low initial leakage current exhibited constant characteristics. After high current impulse test, A\`s ZnO varistor has broken the side of varistor but impulse current flowed. On the contrary, E\`s ZnO Varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After long duration impulse current test, E\`s ZnO varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After high current impulse test and long duration impulse current test, E\`s ZnO varistor exhibited very good characteristics which variation rate of residual voltage is 1.4% before and after test.

AC 모듈형 태양광 모듈 집적형 컨버터를 위한 소프트 스위칭 DC-DC 컨버터 (Soft Switching DC-DC Converter for AC Module Type PV Module Integrated Converter)

  • 윤선재;김영호;정용채;원충연
    • 전력전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.247-255
    • /
    • 2013
  • In this paper, a soft switching DC-DC converter for AC module type photovoltaic (PV) module integrated converter is proposed. A push-pull converter is suitable for a low voltage PV AC module system because the step-up ratio of a high frequency transformer is high and the number of primary side switches is relatively small. However, the conventional push-pull converters do not have high efficiency because of high switching losses by hard switching and transformer losses (copper and iron losses) by high turns-ratio of the transformer. In the proposed converter, primary side switches are turned on at zero voltage switching (ZCS) condition and turned off at zero current switching (ZVS) condition through parallel resonance between secondary leakage inductance of the transformer and a resonant capacitor. Therefore the proposed push-pull converter decreases the switching loss using soft switching of the primary switches. Also, the turns-ratio of the transformer can be reduced by half using a voltage-doubler of secondary side. The theoretical analysis of the proposed converter is verified by simulation and experimental results.

Analysis and Implementation of LC Series Resonant Converter with Secondary Side Clamp Diodes under DCM Operation for High Step-Up Applications

  • Jia, Pengyu;Yuan, Yiqin
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.363-379
    • /
    • 2019
  • Resonant converters have attracted a lot of attention because of their high efficiency due to the soft-switching performance. An isolated high step-up converter with secondary-side resonant loops is proposed and analyzed in this paper. By placing the resonant loops on the secondary side, the current stress for the resonant capacitors is greatly reduced. The power loss caused by the equivalent series resistance of the resonant capacitor is also decreased. Clamp diodes in parallel with the resonant capacitors ensure a unique discontinuous current mode in the converter. Under this mode, the active switches can realize soft-switching during both turn-on and turn-off transitions. Meanwhile, the reverse-recovery problems of diodes are also alleviated by the leakage inductor. The converter is essentially a step-up converter. Therefore, it is helpful for decreasing the transformer turn-ratio when it is applied as a high step-up converter. The steady-state operation principle is analyzed in detail and design considerations are presented in this paper. Theoretical conclusions are verified by experimental results obtained from a 500W prototype with a 35V-42V input and a 400V output.

딥러닝을 이용한 부채널 데이터 압축 프레임 워크 (Side-Channel Archive Framework Using Deep Learning-Based Leakage Compression)

  • 정상윤;진성현;김희석
    • 정보보호학회논문지
    • /
    • 제34권3호
    • /
    • pp.379-392
    • /
    • 2024
  • 데이터의 급속한 증가와 함께 저장 공간 절약과 데이터 전송의 효율성이 중요한 문제로 대두되면서, 데이터 압축기술의 효율성 연구가 중요해졌다. 무손실 알고리즘은 원본 데이터를 정확히 복원할 수 있지만, 압축 비율이 제한적이며, 손실 알고리즘은 높은 압축률을 제공하지만 데이터의 일부 손실을 수반한다. 이에 딥러닝 기반 압축 알고리즘, 특히 오토인코더 모델이 데이터 압축 분야에서 활발한 연구가 진행됐다. 본 연구에서는 오토인코더를 활용한 새로운 부채널 분석 데이터 압축기를 제안한다. 제안하는 부채널 데이터 대상 압축기는 부채널데이터 특성을 잘 유지할 뿐만 아니라, 기존의 널리 사용되는 Delfate 압축방식 대비 높은 압축률을 보인다. 로컬 연결 레이어를 사용한 인코더는 부채널 데이터의 시점별 특성을 효과적으로 보존하고, 디코더는 멀티 레이어 퍼셉트론을 사용하여 빠른 압축해제 시간을 유지한다. 상관 전력 분석을 통해 제안된 압축기가 부채널 데이터의 특성을 손실 없이 데이터 압축이 가능을 증명하였다.

압전 변압기를 이용한 인버터식 네온관용 변압기에 관한 연구 (A Study on the Inverter Type Neon Power Supply Using a Piezoelectric Transformer)

  • 변재영;김윤호
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.504-511
    • /
    • 2003
  • 본 연구에서는 네온 변압기를 세라믹 계열의 압전 변압기를 이용한 인버터식 네온관용 변압기를 제안하였다 인버터식 네온관용 압전 변압기의 주요 구성은 정류부, 발진부, 공진형 하프브릿지 인버터회로부 및 압전 변압기부로 구성 제작하였다. 네온관용 변압기는 지금까지 개발된 압전 변압기 용량 보다 대부분 큰 용량을 필요로 하고 있기 때문에 압전 변압기의 용량 증가를 위해 병렬 구동하였다 이때 병렬로 연결된 단층형 압전 변압기간 내부 임피던스 값의 불일치로 발생하는 불평형 전류를 최소화 하기 위하여 압전 변압기별로 LC 필터값을 분석 부착하여 전압의 왜곡율을 최소화 하여 안정된 정현파 출력을 구현하였다. 그리고 이를 컴퓨터 시뮬레이션 실험과 실제 네온관 부착 실험을 통하여 전력 밀도와 절연 레벨이 높고, 누설 자속이 없는 소형, 경량화된, 압전 변압기를 적용한 인버터식 네온관용 변압기가 기존의 자기식 네온관용 변압기 보다 우수함을 비교 입증하였다.

Measured Return Loss and Predicted Interference Level of PCB Integrated Filtering Antenna at Millimeter-Wave

  • Lee Jae-Wook;Kim Bong-Soo;Song Myung-Sun
    • Journal of electromagnetic engineering and science
    • /
    • 제5권3호
    • /
    • pp.140-145
    • /
    • 2005
  • In this paper, an experimental investigation for return loss and a software-based prediction for interference level of single-packaged filtering antenna composed of dielectric waveguide filter and PCB(Printed Circuit Board) slot antenna in transceiver module have been carried out with several different feeding structures in millimeter-wave regime. The implementation and embedding method of the existing air-filled waveguide filters working at millimeter-wave frequency on general PCB substrate have been described. In a view of the implementation of each components, the dielectric waveguide embedded in PCB and LTCC(Low Temparature Co-fired Ceramic) substrates has employed the via fences as a replacement with side walls and common ground plane to prevent energy leakage. The characteristics of several prototypes of filtering antenna embedded in PCB substrate are considered by comparing the wideband and transmission characteristics as a function of bent angle of transmission line connecting two components. In addition, as an essential to the packaging of transceiver module working at millimeter-wave, miniaturization technology maintaining the performances of independent components and the important problems caused by integrating and connecting the different components in different layers are described in this paper.