The Academic Congress of Korean Shoulder and Elbow Society
/
2005.11a
/
pp.198-205
/
2005
1. Many design features including suture type, anchor size and geometry, and anchor material, play a role in the overall strength of the anchor. In addition, technical considerations such as implant orientation, pattern, and location may affect the ultimate success of the repair. 2. Multiple fixation points provide a biomechanically sounder construct in Bankart repair. The size of the glenoid and its rim make anchor size a critical consideration in implant selection and implementation.
Purpose: The purpose of this study was to evaluate the results of bioabsorbable knotless suture anchoring for isolated type II SLAP. Materials and Methods: Fourteen patients with isolated type II SLAP underwent a surgical repair with bioabsorbable knotless anchor arthroscopically. Instability, rotator cuff tears or simple subacromial decompression were excluded. The UCLA and pain of VAS (Visual Analogue Scale), ADL (Activity of Daily Living, from the American Shoulder and Elbow Society) were evaluated and patients underwent a thorough shoulder examination at a minimum follow-up period of 2 years postoperatively. Results: At a mean of 27.1 months follow-up. The mean UCLA score improved from 14.4 pre-operatively to 31.2 on last follow-up. The mean VAS for pain was 4.9 and on last follow-up 1.0. The mean VAS for instability was 2.6 and on last follow-up 0.5. The mean ADL was 10.4 and on last follow-up 25.0. 12 patients reported their satisfaction as good to excellent and 10 of the 14 patients returned to their pre-injury level of activity (athletics) (P<0.05). Conclusion: Arthroscopic repair with bioabsorbable knotless suture anchors is an effective surgical technique for the treatment of an isolated unstable type II SLAP lesion. Overall satisfaction was only 85.7%. 1 patient had severe stiffness and 1 patient had shoulder pain.
Kim Seung-Ki;Song In-Soo;Seo Hyun Mo;Moon Myung-Sang;Lin Guang
Clinics in Shoulder and Elbow
/
v.7
no.2
/
pp.65-69
/
2004
Purpose: The purpose of this study is to evaluate the short-term clinical outcome of the capsulolabral repair using absorbable suture anchor in traumatic anterior instability of shoulder. Materials and Methods: From June 2000 to September 2001, 15 shoulders with recurrent anterior instability were operated with arthroscopic Bankart repair using absorbable suture-anchor 'PANALOK' (Mitek, westwood, MA), and were followed up over 1 year (average; 13 months). The mean age was 23-years. There were fourteen males and one female. The mean duration from the initial symptoms to the operation was 24 months. Associated pathologies were Hill-Sachs defect in 12 cases, SLAP in 6 cases, and partial rotator cuff tear in 2 cases. The results were evaluated by patien's satisfaction, Modified Rowe Score in regard to joint stability, mobility, pain and function in comparison with the preoperative ones, and other complications. Results: At the last follow-up, the total Rowe Score increased from 38 points to 92 points. There were no recurrence and 14 patients among 15 patients gained pre-operative level of sports activity and no other complications. Conclusion: Effective capsulolabral repair could be obtained by the absorbable anchoring without any untoward complications. This procedure is simple and safe one and this system can be a good substitute for the metallic anchor.
Kim Bo-Hyun;Byun Jae-Yong;Hong Chang-Wha;Hwang Chan-Ha;Yoo Ju-Seok;Kim Sang-Bum
Clinics in Shoulder and Elbow
/
v.8
no.1
/
pp.23-30
/
2005
Purpose: This paper analyzes the results of arthroscopic bankart repair for anterior recurrent dislocation following a trauma on shoulder. Material and Methods: The subjects were twenty-three (23) cases that were available to follow up for more than eighteen months during the period from November 2001 to June 2003 and were chosen from patients to whom arthroscopic bankart repair was applied using a knotless suture anchor for their traumatic anterior recurrent dislocation on the shoulder. Their average age was 28 (ranging from 15 to 60) with 20 males and 3 females. The injury from sports activities accounted for the most cases with 14 subjects. The average follow-up period was 27 months (ranging from 18 months to 35 months). There were 19 cases of bankart lesions, 4 cases of ALPSA lesions and associated with 5 cases of partial tear in the rotator cuff. The anchors employed were knotless anchor (Mitek) for all the cases. Rowe scoring scale was adopted to judge the results after operations. Patients' subjective satisfaction and range of motion of external rotation were addressed together. Results: Rowe scores showed that 20 cases (87%) reaches the level of 'good' and hinger. The average patients' satisfaction accounted for 90 points out of 100. It was also found that external rotations averagely decreased by 6.5 degree when the range of motion was in at the side. Conclusion: There were satisfactory results of arthroscopic bankart repair using knotless suture anchors as an operative treatment for traumatic anterior recurrent dislocation on shoulder.
Michael J. Gutman;Jacob M. Kirsch;Jonathan Koa;Mohamad Y. Fares;Joseph A. Abboud
Clinics in Shoulder and Elbow
/
v.27
no.1
/
pp.39-44
/
2024
Background: Displaced olecranon fractures constitute a challenging problem for elbow surgeons. The purpose of this study is to evaluate the role of suture anchor fixation for treating patients with displaced olecranon fractures. Methods: A retrospective review was performed for all consecutive patients with displaced olecranon fractures treated with suture anchor fixation with at least 2 years of clinical follow-up. Surgical repair was performed acutely in all cases with nonmetallic suture anchors in a double-row configuration utilizing suture augmentation via the triceps tendon. Osseous union and perioperative complications were uniformly assessed. Results: Suture anchor fixation was performed on 17 patients with displaced olecranon fractures. Functional outcome scores were collected from 12 patients (70.6%). The mean age at the time of surgery was 65.6 years, and the mean follow-up was 5.6 years. Sixteen of 17 patients (94%) achieved osseous union in an acceptable position. No hardware-related complications or fixation failure occurred. Mean postoperative shortened disabilities of the arm, shoulder, and hand (QuickDASH) score was 3.8±6.9, and mean Oxford Elbow Score was 47.5±1.0, with nine patients (75%) achieving a perfect score. Conclusions: Suture anchor fixation of displaced olecranon fractures resulted in excellent midterm functional outcomes. Additionally, this technique resulted in high rates of osseous union without any hardware-related complications or fixation failures.
Lee, Hyun Il;Ryu, Ho Young;Shim, Sang-Jun;Yoo, Jae Chul
Clinics in Shoulder and Elbow
/
v.18
no.4
/
pp.197-205
/
2015
Background: The purpose of this study was to evaluate the postoperative magnetic resonance imaging (MRI) results of minimal-tying (one medial-row tie among 4 medial-row sutures) on the medial-row in double-row suture-bridge configuration ($2{\times}2$ anchor with $4{\times}4$ suture stands). Methods: From 2011 March to 2012 July, 79 patients underwent arthroscopic rotator cuff repair using $2{\times}2$ anchor double-row configuration. The mean age was 61.3 years (range, 31-81 years). Two double-loaded suture anchors were used for medial-row. Four medial-row stitches were made with only one medial-row knot-tying (the most anterior suture). Lateral-row was secured using the conventional suture-bridge anchor technique; all 4 strands were used for each anchor. Repair integrity was evaluated with MRI at mean 6.2 months postoperatively. Retear and the pattern of retear, change of fatty infiltration, and muscle atrophy of supraspinatus were evaluated using pre- and postoperative MRI. Results: Repaired tendon integrity was 38 for type I, 30 for type II, 6 for type III, 4 for type IV, and 1 for type V, according to Sugaya classification. Considering type IV/V as retear, the rate was 6.3% (5 out of 79 patients). Medial cuff failure was observed in 4 patients. Fatty atrophy of supraspinatus was significantly improved postoperatively according to Goutallier grading (p=0.01). The level of muscle atrophy of supraspinatus was not changed significantly after surgery. Conclusions: Minimal tying technique with suture configuration of four-by-four strand double-row suture-bridge yielded a lower retear rate (6.3%) in medium to large rotator cuff tears.
Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Choi, Eui-Sung;Keum, Sang-Wook;Kil, Kyoung-Min;Lim, Chae-Wook;Park, Sang-Jun
Clinics in Shoulder and Elbow
/
v.17
no.3
/
pp.134-137
/
2014
To report the fracture of proximal humerus in the lateral anchor site after suture bridge repair. A 57-year-old female patient with shoulder pain on the right-side was admitted through the emergency room following a car accident. Seven weeks before the accident, the patient had undergone surgery at a different hospital for the repair of supraspinatus tendon rupture on the right-side via suture bridge technique. Humerus surgical neck fracture was confirmed by X-ray, and proximal humerus fracture at the anchor site was confirmed by magnetic resonance imaging. Following 7 months of conservative treatment resulted in satisfactory bone union and motion of the shoulder joint. We report the need of close observation during and after the arthroscopic repair of the rotator cuff in patients with osteoporosis.
The Academic Congress of Korean Shoulder and Elbow Society
/
2008.03a
/
pp.166-166
/
2008
A 25-year-old man presented with a history of pain and crepitus in the right shoulder; he had been previously treated with arthroscopic anterior stabilization using four metallic suture anchors for recurrent traumatic anterior instability 1 year earlier. In this report, we present a patient with recurrent glenohumeral instability combined with anchor-induced arthropathy who was managed with modified arthroscopic transglenoid reconstruction following arthroscopic suture anchor retrieval.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.