• Title/Summary/Keyword: Shot Problem

Search Result 87, Processing Time 0.024 seconds

A Fast Background Subtraction Method Robust to High Traffic and Rapid Illumination Changes (많은 통행량과 조명 변화에 강인한 빠른 배경 모델링 방법)

  • Lee, Gwang-Gook;Kim, Jae-Jun;Kim, Whoi-Yul
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.3
    • /
    • pp.417-429
    • /
    • 2010
  • Though background subtraction has been widely studied for last decades, it is still a poorly solved problem especially when it meets real environments. In this paper, we first address some common problems for background subtraction that occur in real environments and then those problems are resolved by improving an existing GMM-based background modeling method. First, to achieve low computations, fixed point operations are used. Because background model usually does not require high precision of variables, we can reduce the computation time while maintaining its accuracy by adopting fixed point operations rather than floating point operations. Secondly, to avoid erroneous backgrounds that are induced by high pedestrian traffic, static levels of pixels are examined using shot-time statistics of pixel history. By using a lower learning rate for non-static pixels, we can preserve valid backgrounds even for busy scenes where foregrounds dominate. Finally, to adapt rapid illumination changes, we estimated the intensity change between two consecutive frames as a linear transform and compensated learned background models according to the estimated transform. By applying the fixed point operation to existing GMM-based method, it was able to reduce the computation time to about 30% of the original processing time. Also, experiments on a real video with high pedestrian traffic showed that our proposed method improves the previous background modeling methods by 20% in detection rate and 5~10% in false alarm rate.

Study on the Visual Characteristics and Subjectivity in the Live Action Based Virtual Reality (실사기반 가상현실 영상의 특징과 주체 구성에 대한 연구)

  • Jeon, Gyongran
    • Cartoon and Animation Studies
    • /
    • s.48
    • /
    • pp.117-139
    • /
    • 2017
  • The possibility of interactivity of digital media environment is adopted in human expression system and integrates the dynamic aspect of digital technology with expressive structure, thereby transforming the paradigm of image acceptance as well as image expression range. Virtual reality images have an important meaning in that they are changing the one-way mechanism of production and acceptance of images that lead to producers-video-audiences beyond the problem of verisimilitude such as how vividly they simulate reality. First of all, the virtual reality image is not one-sided but interactive image composed by the user. Viewing a virtual reality image does not just see the camera shine, but it gets the same view as in the real world. Therefore, the image that was controlled through framing changes to be configured positively by the user. This implies a change in the paradigm of image acceptance as well as a change in the existing form of the image itself. In addition, the narrative structure of the image and the subjects that are formed in the process are also required to be discussed. In the virtual reality image, the user 's gaze is a fusion of the gaze inside the image and the gaze outside the image. This is because the position of the user as the subject of the gaze in the virtual reality image is continuously restricted by the device of the discourse such as the editing and the narration of the shot. The significance of the virtual reality image is not aesthetically perfect but it is reconstructed according to the user to reflect the existence of the user positively and engage the user in the image.

Fast Scene Change Detection Using Macro Block Information and Spatio-temporal Histogram (매크로 블록 정보와 시공간 히스토그램을 이용한 빠른 장면전환검출)

  • Jin, Ju-Kyong;Cho, Ju-Hee;Jeong, Jae-Hyup;Jeong, Dong-Suk
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.1
    • /
    • pp.141-148
    • /
    • 2011
  • Most of the previous works on scene change detection algorithm focus on the detection of abrupt rather than gradual changes. In general, gradual scene change detection algorithms require heavy computation. Some of those approaches don't consider the error factors such as flashlights, camera or object movements, and special effects. Many scenes change detection algorithms based on the histogram show better performances than other approaches, but they have computation load problem. In this paper, we proposed a scene change detection algorithm with fast and accurate performance using the vertical and horizontal blocked slice images and their macro block informations. We apply graph cut partitioning algorithm for clustering and partitioning of video sequence using generated spatio-temporal histogram. When making spatio-temporal histogram, we only use the central block on vertical and horizontal direction for performance improvement. To detect camera and object movement as well as various special effects accurately, we utilize the motion vector and type information of the macro block.

3D Film Image Classification Based on Optimized Range of Histogram (히스토그램의 최적폭에 기반한 3차원 필름 영상의 분류)

  • Lee, Jae-Eun;Kim, Young-Bong;Kim, Jong-Nam
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.71-78
    • /
    • 2021
  • In order to classify a target image in a cluster of images, the difference in brightness between the object and the background is mainly concerned, which is not easy to classify if the shape of the object is blurred and the sharpness is low. However, there are a few studies attempted to solve these problems, and there is still the problem of not properly distinguishing between wrong pattern and right pattern images when applied to actual data analysis. In this paper, we propose an algorithm that classifies 3D films into sharp and blurry using the width of the pixel values histogram. This algorithm determines the width of the right and wrong images based on the width of the pixel distributions. The larger the width histogram, the sharp the image, while the shorter the width histogram the blurry the image. Experiments show that the proposed algorithm reflects that the characteristics of these histograms allows classification of all wrong images and right images. To determine the reliability and validity of the proposed algorithm, we compare the results with the other obtained from preprocessed 3D films. We then trained the 3D films using few-shot learning algorithm for accurate classification. The experiments verify that the proposed algorithm can perform higher without complicated computations.

A Field Efficacy Trial of Inactivated Hantaan Virus Vaccine ($Hantavax^{TM}$) Against Hemorrhagic Fever with Renal Syndrome (HFRS) in the Endemic Areas of Yugoslavia from 1996 to 1998 ($1996{\sim}1998$년 유고슬라비아에서 실시한 한탄바이러스 불활화 백신($Hantavax^{TM}$)의 면역효과에 대한 야외시험)

  • Chu, Yong-Kyu;Gligic, Anna;Tomanovic, Snezana;Bozovjc, Boyana;Obradovic, Mirceta;Woo, Young-Dae;An, Chang-Nam;Kim, Hun;Jiang, Yang-Seok;Park, Seung-Chul;Kim, Min-Ja;Lee, Eun-Il;Lee, Ho-Wang
    • The Journal of Korean Society of Virology
    • /
    • v.29 no.2
    • /
    • pp.55-64
    • /
    • 1999
  • In Yugoslavia, hemorrhagic fever with renal syndrome (HFRS) is one of the important national health problem, but no vaccine has been used to prevent HFRS. Since first HFRS case in 1952, sporadic cases of HFRS occurred every year and over 4,000 registered cases with $1{\sim}16%$ mortality so far. We performed a prospective, randomized double-blind placebo-controlled trial to evaluate the effectiveness of $Hantavax^{TM}$ against HFRS in 3,900 healthy adults living in the endemic areas of Yugoslavia. 1,900 people were given 0.5 ml of Hantavax subcutaneously twice at one month interval and a booster shot at one year after. For controls other 2,000 healthy people were given 0.5 ml of physiolosical saline as a placebo. We investigated HFRS cases in both the vaccinated and nonvaccinated groups by monitoring the program for patient registration in the areas from 1996 to 1998, and the effect of vaccine was analyzed epidemiologically. No confirmed case of HFRS was observed among 1,900 Hantavax vaccinees, while 20 confirmed cases were observed among 2,000 nonvaccinated control group. There were no remarkable side effects among the vaccinees either locally or in general after inoculation of the vaccine. The Hantavax vaccine showed statistically significant protective efficacy against HFRS among Yugoslavian people.

  • PDF

Seismic wave propagation through surface basalts - implications for coal seismic surveys (지표 현무암을 통해 전파하는 탄성파의 거동 - 석탄 탄성파탐사에 적용)

  • Sun, Weijia;Zhou, Binzhong;Hatherly, Peter;Fu, Li-Yun
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Seismic reflection surveying is one of the most widely used and effective techniques for coal seam structure delineation and risk mitigation for underground longwall mining. However, the ability of the method can be compromised by the presence of volcanic cover. This problem arises within parts of the Bowen and Sydney Basins of Australia and seismic surveying can be unsuccessful. As a consequence, such areas are less attractive for coal mining. Techniques to improve the success of seismic surveying over basalt flows are needed. In this paper, we use elastic wave-equation-based forward modelling techniques to investigate the effects and characteristics of seismic wave propagation under different settings involving changes in basalt properties, its thickness, lateral extent, relative position to the shot position and various forms of inhomogeneity. The modelling results suggests that: 1) basalts with high impedance contrasts and multiple flows generate strong multiples and weak reflectors; 2) thin basalts have less effect than thick basalts; 3) partial basalt cover has less effect than full basalt cover; 4) low frequency seismic waves (especially at large offsets) have better penetration through the basalt than high frequency waves; and 5) the deeper the coal seams are below basalts of limited extent, the less influence the basalts will have on the wave propagation. In addition to providing insights into the issues that arise when seismic surveying under basalts, these observations suggest that careful management of seismic noise and the acquisition of long-offset seismic data with low-frequency geophones have the potential to improve the seismic results.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF