• Title/Summary/Keyword: Shorten method

Search Result 482, Processing Time 0.028 seconds

Study on Concurrent Simulation Technique of EPS and A Full Car Model (EPS와 완전차량모델의 동시시뮬레이션 기술에 관한 연구)

  • Jang, Bong-Choon
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11b
    • /
    • pp.785-787
    • /
    • 2010
  • It is well known that most power steering systems obtain the power by a hydraulic mechanism. Therefore, it consumes more energy because the oil power should be sustained all the times. Recently, to solve this problem the Electric Power System(EPS) or Motor Driven Power System(MDPS) has widely equipped in passenger vehicles. In this research the concurrent simulation technique for an EPS system with MATLAB/SIMULINK and a full vehicle model has been developed. The dynamic responses of vehicle chassis and steering system are evaluated. Then, a full vehicle model interacted with EPS control is concurrently simulated with an impulsive steering wheel torque input to analyze the stability of 'free control' or hands free motion for SUV. This integrated method allows engineers to reduce the prototype testing cost and to shorten the developing period.

  • PDF

Pulse-echo Response of Ultrasonic Transducer Fabricated by PZT-Polymer 3-3 Type Composite Resonator for Distance Measurement Applications (거리측정용 PZT-고분자 3-3형 복합압전체 트랜스듀서의 펄스에코 응답특성)

  • 주용관;박정학;최헌일;사공건
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.205-208
    • /
    • 1995
  • PZT powders were prepared by the molten salt synthesis method. The porous PZT specimens were prepared from a mixture of PZT and Polyvinylalcohol(PVA) powders by BURPS(Burnout Plastic Sphere) technique. The pulse-echo response of PZT-polymer 3-3 type composite transducer with various PVA wt.% were studied, The fall time of pulse-echo response of PZT-polymer 3-3 type composite transducer was shorten to that of solid PZT-maded transducer. Therefore, a good transmitting and receiving properties could be obtained. The distance between transducer and reflector was in good agreement both solid PZT and PZT-polymer 3-3 type composite fabricated transducer.

  • PDF

Productivity Improvement Plan Using Motion Analysis and Facility Relocation : Case Study (동작분석과 설비 재배치를 통한 생산성 향상 방안 : 사례연구)

  • Kim, Dong-Hyun;Park, Dong-Bin;Kwon, Ick-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.1
    • /
    • pp.71-81
    • /
    • 2010
  • Today's fierce competition and global economic recession make most of manufacturing companies in the world difficult to gain a profit. In order to survive such a environment and increase competitiveness, manufacturing companies have to continuously eliminate their wasteful factors through an efficient process analysis, improve quality of products, increase the flexibility of manufacturing processes. In this paper, we consider a case study for the Shanghai New Auto which is a subcontractor of MOBIS in China, to improve productivity by using therblig method, one of the motion analysis, to minimize the work-in-process inventories and to shorten the manufacturing cycle times. We also try to relocate the facility layout to increase the efficiency and flexibility of manufacturing processes.

Three Cases of Korean Medical Treatments of Psoriasis Patients with Psoraleae Semen extract (건선의 한방치험 3례 - 보골지추출물을 병행하여)

  • Kim, Chul-Yun;Yoon, Jung-Jeh;Jo, Su-Ji
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.31 no.3
    • /
    • pp.116-126
    • /
    • 2018
  • Objectives : The purpose of this study is to report the effect of Psoraleae Semen extract and korean medical treatments on 3 psoriasis patients. Methods : 200g of Psoraleae Semen was dipped in $1000m{\ell}$ of alcohol for 7days. The residue was filtered to use the solution. Extract was applied to psoriasis and UVB rays were irradiated for 10 minutes or more. PASI(psoriasis area and severity) score was used to check the prognosis of 3 psoriasis patients. Results : All three cases achieved PASI 50 within 4 weeks and two of 3 cases reached PASI 75 within 4 weeks. Conclusions : Psoraleae Semen extract and korean medical treatments is effective method for treating Psoriasis. It can shorten the duration of treatment of Psoriasis.

Cycle Reduction Simulation for Turning Process (선삭 가공 사이클 단축 시뮬레이션)

  • Kim, Sun-Ho;Cho, Hang-Deuk;Kim, Tae-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Productivity of machining using machine tools is affected by cutting conditions such as cutting speed, feedrate and depth. However, undesirable conditions that lengthen the machining cycle and shorten the tool life occur frequently because determination of cutting condition is known to depend on human experience. This paper presents a method of cycle reduction by removing undesirable conditions. For cycle reduction, maximum cutting load is determined using commercial FEM simulation code. The feedrate in the NC program is altered based on a predetermined cutting load value. To make a decision on the proposed effectiveness, a simulation is performed for the brake hub parts of an automobile. From the evaluation, it was found that the cycle reduction was under 15%.

Directional Postprocessing Techniques to Improve Image Quality in Wavelet-based Image Compression (웨이블릿 기반 압축영상의 화질 향상을 위한 방향성 후처리 기법)

  • 김승종;정제창
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.6B
    • /
    • pp.1028-1040
    • /
    • 2000
  • Since image data has large data amount, proper image compression is necessary to transmit and store the data efficiently. Image compression brings about bit rate reduction but results in some artifacts. This artifacts are blocking artifacts, mosquito noise, which are observed in DCT based compression image, and ringing artifacts, which is perceived around the edges in wavelet based compression image. In this paper, we propose directional postprocessing technique which improved the decoded image quality using the fact that human vision is sensible to ringing artifacts around the edges of image. First we detect the edge direction in each block. Next we perform directional postprocessing according to detected edge direction. Proposed method is that the edge direction is block. Next performed directional postprocessing according to detected edge direction. If the correlation coefficients are equivalent to each directions, postprocessing is not performed. So, time of the postproces ing brings about shorten.

  • PDF

Optimized design of the multimode interferenced-polarization splitter with a photodefinable polyimide (감광성 폴리이미드 재료를 가정한 다중모드 간섭 편광분리 소자의 최적설계)

  • Hong, Jung-Moo;Ryoo, Hyun-Ho;Jeong, Jae-Wan;Lee, Seung-Gol;Lee, El-Hang;Park, Se-Geun;O, Beom-Hoan;Woo, Deok-Ha;Kim, Sun-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04b
    • /
    • pp.101-104
    • /
    • 2002
  • The beam splitter is important in optical communication systems. in this work, thc quasi-state based on four-mode interference in thc MMI coupler is proposed, and so, device length is shorten to be 1/5 of general designed length. We designed thc polarization splitter based on thc concept of quasi-state. Thc analysis has been accomplished by thc effective index method(EIM) and thc mode propagation analysis(MPA) for given structure.

  • PDF

Exposure Does of X-ray Generator on Full Wave Rectification Method (전파정류 방식의 X선 발생장치에서 조사선량)

  • Kim, Tae-Gon;Kim, Young-Pyo;Cheon, Min-Woo;Lee, Ho-Shik;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.138-138
    • /
    • 2010
  • X-ray systems for medical treatment use noninvasive procedures. I fabricated a high tension generator of a full-wave rectification type using a LC resonant inviter. It is said that a full-wave rectifying X-ray equipment such as the fabricated system can shorten initiating period and be precision control because of stable output, compared with the X-ray equipment of a half wave rectifying type used in the usual clinical medicine. In order to evaluate the capability of the fabricated high tension generator, I performed exposure dose characteristics experiments.

  • PDF

Web-based 3D Animation System for Visualization of Motions of Mechanisms (웹기반 3차원 기구 동적 거동 가시화 시스템 개발)

  • 남소정;한형석;이재경;김동성
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1735-1738
    • /
    • 2003
  • The dynamic design and evaluation of mechanisms need to be performed in a collaboration or concurrent system in order to shorten the development period of the product. A web-based system is the most suitable concurrent system to promote effective collaboration. In order to develop such a web-based system, Java Applet, which is not restrained by a computer's H/W and S/W, is widely used. This paper introduces a web-based 3D animation system for visualizing the motions of mechanisms. This web-based 3D animation system uses a JAVA Applet program method, which can be operated in a web-browser, and the Open Inventor for Java, which supports 3D graphics. It does not only allows the user to verify dynamic simulation results and design variables through the web, but it also has the advantage of supporting collaboration among a number of users through simultaneous connections.

  • PDF

Management in the EPC Business for Overseas Power Plant Projects (해외 발전플랜트 EPC 사업의 리스크 분석 및 관리방안)

  • Park, Euiseung;Yoo, Hoseon;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.7 no.3
    • /
    • pp.48-64
    • /
    • 2011
  • In this work, risks in EPC project for overseas power plant projects are analyzed and risk management methods are suggested to reduce cost and to shorten time. 79% of risks occurred in the engineering phase for S project located in South-East Asia. The impact scales of risks on major project objectives which are cost, time, scope, and quality are analyzed as 3.5, 3.8, 2.7, and 3.7, respectively. The level of impact scales is very similar to each other except the impact scale of scope. The risk management methods suggested in this study have to be applied at the appropriate time to manage risks effectively. After that, risks are managed continuously by monitoring.

  • PDF