전원전압에 따른 초전도 사고전류제한기의 퀜치속도 분석 (Analysis on Quench Velocity of SFCL dependent on Source Voltage)

  • 임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제20권10호
    • /
    • pp.889-894
    • /
    • 2007
  • We investigated the quench velocity of superconducting fault current limiter (SFCL) dependent on the source voltage. $YBa_2Cu_3O_7$ (YBCO) thin film was used as the current limiting element for SFCL. The analysis on the quench velocity of SFCL is essential to determine the capacity of circuit breaker (CB) or coordinate with CB. Generally, the quench velocity of SFCL is related with the short-circuit current. To change the short-circuit current, in this paper, the amplitude of the power source voltage is adjusted. Through the fault current limiting experiments, the quench velocity of SFCL was confirmed to increase fast as the source voltage increased. On the other hand, the peak limited current was shown to increase with steady rate of increase.

교류발전기 병렬운전시 과도현상 해석에 관한 연구 (A Study on the Transient Phenomenon Analysis at the instant of Parallel Running for A.C. Generators)

  • 오세진;김현수;김성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권5호
    • /
    • pp.1065-1075
    • /
    • 2001
  • It is common knowledge amongst electrical and marine engineers that short-circuit in electrical system may cause large mechanical torque on generator and prime mover However, it is not so widely known that the faulty synchronizing of generators may cause even higher torques than that of short-circuit. In this study, the transient phenomena related to the parallel running of synchronous generators are analyzed and the exact computer simulation method is proposed. In result, maximum transient torque and current take place in case of $120^{\circ}$ voltage angle difference between Master and Slave and that may develop higher torque than the short-circuit according to a condition of synchronizing. When synchronizing in power system using only two generators higher torque and current occur Master, but using multimachine system those occur to Slave. The short-circuit of marine generator does not happen frequently but faulty synchronizing sometimes takes place, therefore, it is necessary for designers to consider these phenomena.

  • PDF

500MVA 단락발전기 여자시스템 특성 개선에 관한 고찰 (A study of excitation system of 500MVA short-circuit facilities)

  • 정흥수;나대열;김선구;노창일;김원만;이동준;김선호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.685-686
    • /
    • 2006
  • The excitation system of 500MVA short-circuit generator is very important because of operation of various condition, for example, (over) load switching, short-time current, short-circuit current, etc. This paper introduces a feature of excitation system of 500MVA short-circuit facilities and the function and construction of each part.

  • PDF

GMA용접 시스템의 동적 거동에 대한 해석 (Analysis of Dynamic Behavior in GMAW System)

  • 이재영;최재형;이지혜;유중돈
    • Journal of Welding and Joining
    • /
    • 제18권5호
    • /
    • pp.41-48
    • /
    • 2000
  • Dynamic behaviors of the GMAW system are simulated using the short-circuit transfer model and the characteristic equations fir the power supply, wire system and arc. The conventional wire equation, which relates the rate change of the wire extension to the wire feed rate and melting rate, is modified to include effects of the molten drop attached at the wire tip. The modified wire equation describes behaviors of the GMAW system more precisely and provides information about the initial bridge volume for short-circuit transfer. The proposed short-circuit model predicts the variation of parameters such as the current, voltage, short-circuit frequency and time considering the effects of the surface tension and electromagnetic force due to current. The calculated results are in broad agreements with the experimental results under the argon shielding condition.

  • PDF

회전기의 기여에 의한 시변성의 순간전압강하 예측에 관한 연구 (Investigation of the Estimation of Time-Varying Voltage Sags Considering the Short Circuit Contributions of Rotating Machines)

  • 윤상윤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권6호
    • /
    • pp.315-322
    • /
    • 2005
  • In this article, 1 would like to explore the estimation method of time-varying voltage sags in large industrial systems considering the short circuit contributions of rotating machines. For the power distribution system of KEPCO(Korea Electric Power Corporation), the magnitude of initial symmetrical short circuit current is generally not changed. However, in industrial systems which contain a number of rotating machines, the magnitude of voltage sag is generally changed from the initial to the clearing time of a fault due to the decreasing contribution of rotating machines for a fault current. The time-varying characteristics of voltage sags can be calculated using a short circuit analysis that is considered the time-varying fault currents. For this, the prediction formulations of time-varying voltage sags are proposed using a foreign standard. The proposed method contains the consideration of generator and motor effects. For the test of proposed formulations, a simple system of industrial consumer is used for the comparison conventional and proposed estimation method of voltage sag characteristics.

500MVA급 단락발전기 여자시스템의 특성개선 (A study of excitation system of 500MVA short-circuit generator)

  • 정흥수;김선구;노창일;김원만;이동준;김선호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.989-990
    • /
    • 2007
  • The excitation system of 500 MVA short-circuit generator is very important because of operation of various condition, for example, (over) load switching, short-time withstand current, short-circuit making and breaking current, etc. This paper introduces a feature of excitation system of 500MVA short-circuit generator and the function and construction.

  • PDF

보조전원장치의 단락부하 차단기 개방을 위한 제어방법 (Control Method for Cut-out of Shorted Load in the Auxiliary Power Supply)

  • 황광철;조국춘;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.249-254
    • /
    • 1998
  • This paper describes the control methods to cut out the NFB(No Fuse Breaker) of shorted load in the auxiliary power supply, Generally, when the short-circuit occurs in the load of the auxiliary power supply, the auxiliary power supply stops the operation according to the protection sequence. Finally, the other auxiliary power supply stops the operation by the same fault, To resolve this problem, we suggest the control method to trip the NFB of shorted load. That is, when the short circuit occurs, the controller changes control mode from voltage mode to current mode without the operation of output contactor(SIVK) in the auxiliary power supply. The auxiliary power supply provides a large current for the short-circuit load. After some time, the NFB of the short-circuit load is cut off and the auxiliary power supply Provides stable voltage for the loads except for the short-circuit load.

  • PDF

고온초전도 한류기의 전력계통 적용에 관한 연구 (A Study on the Power System Application of High-Tc Superconducting Fault Current Limiter)

  • 배형택;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.115-116
    • /
    • 2006
  • Since the discovery of the high-temperature superconductors, many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means to limit fault current in power systems. The SFCLS, in contrast to current limiting reactors or high impedance transformers, are capable of limiting short circuit currents without adding considerable voltage drop and energy loss to power systems during normal operation. Under fault conditions, a resistance is automatically inserted into the power grid to limit the peak short-circuit current by transition from the superconducting state to the normal state, the quench. The advantages, like fail safe operation and quick recovery, make SFCL very attractive, especially for rapidly growing power systems with higher short-circuit capacities. In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current and voltage stability assessment in a sample distribution system and a transmission system are performed by the PSCAD/EMTDC based simulation method. Through the simulation, the advantage of SFCL application is shown, and the effective parameters of the SFCL are also recommended for both distribution and transmission systems. A resistive type component of SFCL is adopted in the analysis. The simulation results demonstrate not only the effectiveness of the proposed simulation scheme but also SFCL parameter assessment technique.

  • PDF

태양전지의 전기적인 출력특성이 태양전지모듈에 미치는 영향 (The Effects of PV Cell's Electrical Characteristics for PV Module Application)

  • 김승태;강기환;박지홍;안형근;유권종;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.36-41
    • /
    • 2008
  • In this paper, we study The Effects of PV Cell's Electrical Characteristics for PV Module Application. Photovoltaic module consists of serially connected solar cell which has low open circuit voltage and high short circuit current characteristics. The whole current flow of PV module is restricted by lowest current of one solar cell. For the experiment, we make PV module composing the solar cells that have short circuit current difference of 0%, 1%, 3% and Random. The PV module exposed about 35days, its the maximum power drop ratio was 4.282% minimum and 6.657% maximum. And PV module of low current characteristics has electrical stress from other modules. The solar cell temperature of PV module was higher compared to PV cell. To prevent early degradation, it is need to have attention to PV cell selection.

  • PDF

$CO_2$ 용접의 천이이행 조건에서 스패터 발생과 파형인자와의 관계 (Relationship between Spatter Generation and Waveform Factors in Transitional Condition of $CO_2$ Welding)

  • 강봉용;이창한;김희진;장희석
    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.39-46
    • /
    • 1998
  • $CO_2$ gas shielded arc welding has been characterized with its harsh arc compared to Ar-based shielding gases and with its high level of spattere specially in welding current range of 250~300 amperes. In this range of welding current, the metal transfer mode showed to be changed from short circuit to globular with the increase of welding voltage resulting in so-called the transitional mode in which both modes of transfer appeared together. To characterize the transitional mode, the short circuit events were divided into two groups, i.e. normal short circuit (N.S.C) which has short circuit time $(t_s)$ over 2msec and instantaneous short circuit (I.S.C) of $t_s$$\leq$2msec. The experimental results showed that the number of N.S.C decreased almost linearly with the increase of welding voltage and appeared to be not related with spatter generation rate. However I.S.C became to be pronounced in the transitional condition and its number reached the maximum value at around 29.0 volts. Considering the relation with the spatter generation rate, it was found that the number of I.S.C had a very strong correlation with the spatter generation rate of the transitional condition. It was further demonstrated that spatter generation rate decreased quite linearly with the decrease of I.S.C frequency. It implies that I.S.C is the most important waveform factor controlling the spatter generation of the transitional mode, i.e. in the middle range of welding current. Based on these results, It was discussed that in the transitional mode the basic concept of waveform control for suppressing spatter generation would be different from the one applied for typical short circuit transfer mode of low welding current.

  • PDF