Test of Independence Between Variables to Estimate the Frequency of Damage in Heat Pipe (열수송관 파손빈도 추정을 위한 변수간 독립성 검정)

  • Myeongsik Kong;Jaemo Kang;Sungyeol Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.61-67
    • /
    • 2023
  • Heat pipes located underground in urban areas and operated under high temperature and pressure conditions can cause large-scale human and economic damage if damaged. In order to predict damage in advance, damage and construction information of heat pipe are analyzed to derive independent variables that have a correlation with frequency of damage, and a simple regression analysis modified model using each variable is applied to the field. However, as the correlation between independent variables applied to the model increases, the independence between variables is harmed and the reliability of the model decreases. In this study, the independence of the pipe diameter, burial depth, insulation level of monitoring system, and disconnection or short circuit of the detection line, which are judged to be interrelated, was tested to derive a method for combining variables and setting categories necessary to apply to the frequency of damage estimation model. For the test of independence, the continuous variables pipe diameter and burial depth were each converted into three categories, insulation level of monitoring system was converted into two categories, and the categorical variable disconnection or short circuit of the detection line status was kept as two categories. As a result of the test of independence, p-value between pipe diameter and burial depth, level of monitoring system and disconnection or short circuit of the detection line was lower than the significance level (α = 0.05), indicating a large correlation between them. Therefore, the pipe diameter and burial depth were combined into one variable, and the categories of the combined variable were set to 9 considering the previously set categories. The insulation level of monitoring system and the disconnection or short circuit of the detection line were also combined into one variable. Since the insulation level is unreliable when the detection line status is disconnection or short circuit, the categories of the combined variable were set to 3.

Development of Silm Type ELCB For Airport Distribution Panel through Increased short Circuit Capacity (단락용량 증대를 통한 슬림형 공항 분전반용 누전 차단기 개발)

  • Joo, Nam-Kyu;Lee, Jong-Myong;Kim, Nam-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.2
    • /
    • pp.360-366
    • /
    • 2012
  • In the power distribution panel installed in airport or industrial facilities, MCCB has been used for main switch and ELCB for branch switch to perform human body and leakage-inducing fire protection as well as overcurrent and short circuit protection. Especially for the airport panel, increase in accident protection is needed for stable power supply due to rapid modernization with fast-growing users, higer capacity and diversification of equipment, the increase of power capacity and the breaker made slim is a main issue for now because the issue for installation space is standing out by making panel with two-row arrangement connection method, etc. due to a many use of branch ELCBs. In this thesis, we designed arc extinguishing mechanism, considered movement direction change of contact in mechanism design. Also, we designed the breaker to work stably in case of miniaturization of leakage detection circuit and reverse connection. We conducted short circuit test to verify its function and developed the breaker that can be improved protection against accidental current with slim size operating leakage function when reverse connection to help solve the problem in using space that is increasing in the airport distribution panel.

Design and fabrication of the Built-in Testing Circuit for Improving IC Reliability (IC 신뢰성 향상을 위한 내장형 고장검출 회로의 설계 및 제작)

  • Ryu, Jang-Woo;Kim, Hoo-Sung;Yoon, Jee-Young;Hwang, Sang-Joon;Sung, Man-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.5
    • /
    • pp.431-438
    • /
    • 2005
  • In this paper, we propose the built-in current testing circuit for improving reliability As the integrated CMOS circuits in a chip are increased, the testability on design and fabrication should be considered to reduce the cost of testing and to guarantee the reliability In addition, the high degree of integration makes more failures which are different from conventional static failures and introduced by the short between transistor nodes and the bridging fault. The proposed built-in current testing method is useful for detecting not only these failures but also low current level failures and faster than conventional method. In normal mode, the detecting circuit is turned off to eliminate the degradation of CUT(Circuits Under Testing). The differential input stage in detecting circuit prevents the degradation of CUT in test mode. It is expected that this circuit improves the quality of semiconductor products, the reliability and the testability.

Design, Implementation and Testing of HF transformers for Satellite EPS Applications

  • Zahran, Mohamed
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.217-227
    • /
    • 2008
  • The electric power subsystems (EPS) of most remote sensing satellites consist of a solar array as a source of energy, a storage battery, a power management and control (PMC) unit and a charge equalization unit (CEU) for the storage battery. The PMC and CEU use high frequency transformers in their power modules. This paper presents a design, implementation and testing results of a high frequency transformer for the EPS of satellite applications. Two approaches are used in the design process of the transformer based on the pre-determined transformer specifications. The transformer is designed based on an ETD 29 ferrite core. The implemented transformer consists of one center-tapped primary coil with eleven center-tapped secondary coils. The offline calculation results and measured values of R, L for transformer coils are convergence. A test circuit for measuring the transformer parameters like voltage, current and B-H hysteresis was implemented and applied. The test results confirm that the voltage waveforms of both primary and secondary coils were as desired. No overlapping occurred between the control signal and the transformer, which was not saturated during testing even during a short circuit test of the secondary channels. The dynamic B-H loop characteristics of the used transformer cores were measured. The sample test results are given in this paper.

An Efficient Test Algorithm for Dual Port Memory (이중 포트 메모리를 위한 효과적인 테스트 알고리듬)

  • 김지혜;송동섭;배상민;강성호
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.1
    • /
    • pp.72-79
    • /
    • 2003
  • Due to the improvements in circuit design technique and manufacturing technique, complexity of a circuit is growing along with the demand for memories with large capacities. Likewise, as a memory capacity gets larger, testing gets harder and testing cost increases, and testing process in chip development gets larger as well. Therefore, a research on an effective test algorithm to improve the chip yield rate in a short time period is becoming an important task. This paper proposes an effective, March C-algorithm based, test algorithm that can also be applied to a dual-port memory since it considers all the fault types, which can be occurred in a single-port as well as in a dual-port memory, without increasing the test length.

An Experimental Study on the Noise Reduction and the Feasibility of Short Current of a Silencer for a High Voltage COS Fuse (고전압 COS 퓨즈용 소음기의 소음저감 및 전류차단 성능에 관한 실험적 연구)

  • Lee, Dong-Hoon;Song, Hwa-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.783-789
    • /
    • 2008
  • This experimental study describes the noise reduction and the feasibility of short current of a silencer for a high voltage COS(cut out switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the strong impulse noise over 150 dB(A) is generated. For the purpose of the reduction of impulse noise, in this study, the diffuser type and the reactive type silencers have been designed and tested, respectively. And also the electrical test on the short current is performed. From the experimental results, the well designed reactive type silencer has been shown to have the noise reduction of about 20 dB(A). It has been found that the feasibility of short current for the COS fuse is closely related to the porosity of the silencer.

A Study on Current Waveform Control and Performance Improvement for Inverter Arc Welding Machine (인버터 아크 용접기의 파형제어기법 및 성능향상에 관한 연구)

  • 채영민;고재석;김진욱;이승요;최해룡;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.128-137
    • /
    • 1999
  • Recently the pelionnance of CO2 arc welding machine has been advanced significantly through the adoption of i invelter circuit topology. which made it possible to improve welding perfonnances such as spatter generation and bead s state. But the conventional inverter arc welding machine generates constant output voltage which cause much spatter g generation dUling short-circuit and arc start time because it is unable to control output current instantaneously. So this p paper representes wavefCnm controlled inverter arc welding machine which control the wavefonn of welding current and t thus to suppress the spatter generation. And the system designed in this paper is the digital controller using single chip m microprocessor of 80C196KC. As a result of perfonnance test for this system, the spatter generation is reduced and s shOlt-circuit time period is stabilized compared to conventional one. And more by using switched mode rectifier for A AC/DC power convelter. unity power factor is maintained and low order halmonic spectrum is supressed.

  • PDF

Electrochemical Ion Migration Sensitivity of Printed Circuit Board Plated with Sn-3.0Ag-0.5Cu and Sn-37Pb (Sn-3.0Ag-0.5Cu, Sn-37Pb 표면처리 기판의 전기화학적 이온 마이그레이션 민감도)

  • Hong, Won-Sik;Park, No-Chang;O, Cheol-Min;Kim, Gwang-Bae
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.136-138
    • /
    • 2006
  • Recently a lots of problems have observed in high densified and high integrated electronic components. One of them is ion migration phenomena, which induce the electrical short of electrical circuit. Ion migration phenomena has been observed in the field of exposing the specific environment and using for a long time. Also as the RoHS restriction was started in July 1st, 2006, Pb-free solder was utilized in electronics assemblies. In this case, it is very important to compatible between components and printed circuit board(PCB), thus surface treatment materials of PCB was changed to Sn, Sn-3.0Ag-0.5Cu, Cu. Therefore these new application become to need to reevaluate the sensitivity about electrochemical ion migration. This study was evaluated the occurrence time of electrochemical ion migration using by water drop test. We utilized PCB(printed circuit board) having a comb pattern as follows 0.1, 0.318, 0.5, 1.0 mm pattern distance. Sn-3.0Ag-0.5Cu and Sn-37Pb were electroplated on the comb pattern. 6.5V and 15.0V were applied in the comb pattern and then we measured the electrical short time causing by occurring the ion migration. In these results, we evaluate the sensitivity and derived the prediction models of ion migration occurrence time depending on the pattern materials, applied voltage and pattern spacing of PCB conductor.

  • PDF

Low-Velocity Impact Detection of Composite Plate Using Piezopolymer Sensor Signals without Charge Amplifier (전하증폭기를 사용하지 않은 고분자 압전센서 신호를 이용한 복합재 평판의 저속충격 탐지)

  • 김인걸;정석모
    • Composites Research
    • /
    • v.13 no.6
    • /
    • pp.47-54
    • /
    • 2000
  • One promising method for impact detection of composite structures is based on the use of piezopolymer thin fim (PVDf) sensor. In this paper, the relationship between the contact force and the signals of the attached strain gage and PVDF sensor to the composite plate subjected to low-velocity impact were derived. The relation for the open circuit and short circuit voltage of PVDF sensor was derived based on the equivalent circuit model of the piezoelectric sensor. The work was then extended to include experimental investigation into the use of short circuit voltage of PVDF sensor without using charge amplifier to detect low-velocity impact. The natural frequencies and damping ratio of the composite plate obtained from the vibration test were used to modify the analytical model and therefore the differences between measured and simulated signal of the modified analytical model in both forward and backward problem were considerably reduced. The reconstructed contact force and simulated sensor signals agreed well with the measured contact force, strain gage signal, and PVDF sensor singanl.

  • PDF

The evaluation of the analysis software for short-circuit current (단락전류 분석프로그램의 성능 평가)

  • Lee Dong-Jun;Roh Chang-il;Jung Heung-Soo;Kim Sun-Koo;Kim Won-Man;La Dae-Ryeol;Kim Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.845-847
    • /
    • 2004
  • 단락시험시 시험회로의 주요 파라미터들은 시험전압과 시험전류를 이용하여 결정된다. 특히, 단락전류의 경우 전류파형의 피크치, RMS, 시간, DC-성분, 역률 등을 분석프로그램을 이용하여 분석하게 된다. 그러나 이러한 분석프로그램은 각 시험기관마다 다르고, 현재까지 분석프로그램을 검증할 국제저인 기준이 존재하지 않았다. 그러나 최근 들어 STL(Short-circuit Testing Liason)에서는 각 시험기관마다 상이한 분석프로그램을 검증할 절차에 대한 연구를 수행하여 왔으며 그 첫 번째로 단락전류 분석프로그램에 대한 성능 평가 절차가 어느 정도 완성되었다. 이에 본 논문에서는 STL에서 배포한 TDG(Test Data Generator)를 이용해reference curve를 생성하고, 전기연구원의 전류분석프로그램을 사용하여 분석프로그램의 신뢰성을 평가하여 보았다.