• 제목/요약/키워드: Shielding distance

검색결과 136건 처리시간 0.03초

STS 304L의 Nd:YAG 레이저 용접에서 용접조건이 용접부 형상에 미치는 영향 (Effects of the Welding Parameters on the Weld Shape in Nd:YAG Laser Welding of STS 304L)

  • 이형근;석한길;한현수;박울재;홍순복
    • Journal of Welding and Joining
    • /
    • 제22권1호
    • /
    • pp.58-64
    • /
    • 2004
  • The control of the weld bead shape is important in laser welding of the small parts. The effects of laser welding parameters on the weld bead shape in the pulsed Nd:YAG laser welding of STS 304L material were investigated. Shielding gas type, flow rate, pumping voltage, pulse frequency, pulse width, focal position and overlap distance were selected as laser welding parameters. Experiments were designed and conducted using the Taguchi method which was a statistical experimental method. The weld bead width, penetration, area and aspect ratio were measured and analysed as the weld bead shape properties and the welding parameters were optimized to maximize the weld aspect ratio. Weld aspect ratio were greatly affected by the pulse width, pumping voltage and pulse frequency, and somewhat by the overlap distance, and little by the shielding gas type, flow rate and focal position. A confirmation experiment were conducted using the optimized welding parameters.

이동형 방사선 차폐장치의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Portable Radiation Shielding Apparatus)

  • 구본열;한상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.289-295
    • /
    • 2018
  • When using a mobile X-ray unit, primary radiation creates medical images and secondary radiation scatters in many directions, which reduces image quality and causes exposure to patients, care givers and medical personnel. The purpose of this study was to develop a radiation shielding system for effectively shielding secondary radiation and evaluate its effectiveness. Using a mobile X-ray unit, spatial dose according to presence of human equivalent phantom and spatial dose using the developed shielding device were measured, and the phantom at 80 cm equidistance from center of X-ray was compared with spatial dose according to use of a shield. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from the head direction($-90^{\circ}$) to the body direction($+90^{\circ}$). In the spatial dose measurement with and without the phantom, when the human equivalent Phantom was used, the spatial dose was increased by 40% in all directions from 40 cm to 100 cm from the central X-ray, and about 88% of the space dose was reduced when using the developed shields with the phantom. The equidistance dose at 80 cm from the central X-ray was increased by 39% from $5.1{\pm}0.26{\mu}Gy$ to $7.1{\pm}0.15{\mu}Gy$ when the human equivalent phantom was used, and when phantom was used and shielding was used, the spatial dose was reduced by about 90% from $7.1{\pm}0.15{\mu}Gy$ to $0.7{\pm}0.07{\mu}Gy$. The spatial dose of natural radiation was measured to be about $0.2{\pm}0.04{\mu}Gy$ when using the developed shielding with Phantom at a distance of 1 m or more. It is expected that by using the developed shielding system, it will be possible to effectively reduce secondary radiation dose received in all directions and to ensure safe imaging.

방사선(放射線) 차폐물질(遮蔽物質)에서 발생(發生)하는 산란선(散亂線)의 측정(測定) (Some Measurements of Scattered Radiation from Various Radiation Shielding Materials)

  • 김창균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제4권1호
    • /
    • pp.15-22
    • /
    • 1981
  • Half value layer(radiation energy) of $90^{\circ}$ scattered radiation from various radiation shielding materials was measured at 1 m distance from the central ray of the primary beam. Scattered radiation was measured from 100 to 200 kVp for 0-2.0mm Cu+1.0mm Al added filter in the primary beam for a deep therapeutic unit, the obtained results were as follows: 1. The ratio of scattered radiation to primary radiation was increased by using lighter filter. 2. The ratio of scattered radiation to primary radiation was decreased by using heavier filter. 3. The ratio of scattered radiation to primary radiation was independent of tube voltage. 4. The scattered radiation of high energy was produced, when the effective atomic number and density of shielding material were high.

  • PDF

Analysis of the Fume Generation Rates in the Flux Cored Arc welding

  • Chae, H.B.;Kim, J.H.;Yang, S.C.
    • International Journal of Korean Welding Society
    • /
    • 제1권1호
    • /
    • pp.71-77
    • /
    • 2001
  • The characteristics of the fume generation in a flux cored arc welding were investigated using the fume collection chamber developed. The Korean Standard concerning the method for the evaluation of the fume generation rate(FGR) was updated by the evaluation method obtained through this study. It was found that the effect of humidity in the test environment should be considered and the automatic welding method had to be employed for the purpose of the exact evaluation of the fume generation rate. The results showed that the fume generation rate was influenced by the welding parameters. The important factors were the welding current arc voltage, travel speed, and contact tip to work distance(CTWD) that affected the heat input as well as the torch angle and the shielding gas flow rate that influenced the shielding effect. The fume generation rate increased as the heat input increased and the shielding effect decreased. It was also observed that the effect of the welding current is much grater than the other welding parameters.

  • PDF

Zn-Al 합금 선재를 이용한 금속용사 공법 적용 콘크리트의 전자파 차폐 성능 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of EMP Shielding Performance of Concrete Applied with ATMSM Using Zn-Al Alloy Wire)

  • 최현준;박진호;민태범;장현오;이한승
    • 한국건축시공학회지
    • /
    • 제19권3호
    • /
    • pp.209-217
    • /
    • 2019
  • EMP(Electromagnetic Pulse)는 통상적으로 고출력 전자기파 (High Power Electromagnetic: HPEM)를 의미한다. EMP를 차폐하기 위한 차폐 판의 경우, 현장 적용 시, 용접 및 볼트의 연결부(접합부)에서 시공자의 숙련도 및 불량시공, 차폐판의 변형 등으로 인한 전자파 차폐성능 저하의 가능성을 유발하고 있으며, 또한 벽체로부터 이격거리로 인한 비효율적인 공간 활용이 문제점으로 지적 되고 있다. 따라서, 본 연구는 콘크리트 벽체를 대상으로 반사손실에 대한 전자파 차폐성능을 확보하기 위한 일환으로서, 콘크리트에 금속용사 공법을 적용하여 최적의 전자파 차폐 조건을 도출하고자 한다. 실험변수로는 콘크리트 벽체 두께, Zn-Al 금속용사 적용 유무이다. 콘크리트 벽체의 경우, 일반적으로 적용되어지고 있는 벽체 두께인 100~300mm이며, 또한 전자파 차폐성능에 관한 Zn-Al 금속용사 공법의 실효성을 평가하기 위해 적용 유무로 구분하여 실험변수를 설정하였다. 실험 결과 두께가 증가할수록 흡수 손실의 증가로 인해 전자파 차폐성능이 증가하였다. 또한 Zn-Al 금속용사 적용 후 모든 시험체에서 평균 56.68 dB의 상당한 차폐성능 증가를 보였으며, 이는 금속용사 피막의 반사손실에 의하여 증가된 것으로 판단된다. 또한, 전도성 혼입재료와 금속 용사 피막을 동시에 적용할 경우 보다 우수한 차폐성능을 나타낼 것으로 판단된다.

방사성의약품 투여 시 피폭선량 저감에 대한 연구 (The Study of Radiation Reducing Method during Injection Radiopharmaceuticals)

  • 조석원;정석;박준영;오신현;남궁혁;오기백;김재삼;이창호
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.80-85
    • /
    • 2012
  • 전신 골 스캔은 골친화성 방사성의약품으로 뼈의 생리적 변화를 영상화하는 검사방법으로, 140 keV의 감마선을 방출하는 방사성핵종이 표지된 방사성의약품을 주사 후 촬영하는 영상기법이다. 외부피폭으로부터 방사선방호의 3원칙은 시간, 거리, 차폐이다. 방사성의약품은 투여 시 개봉선원이 되기 때문에 방사선방호 원칙에 따라 피폭을 줄이기 위하여 빠른 시간 내에 주사하는 것이 좋다. 하지만 방사성의약품은 환자에게 직접 투여하기 때문에 선원으로부터 거리를 멀리할 수 없는 제한점이 있다. 본 연구는 방사성의약품으로부터 거리에 따른 피폭선량 변화를 확인하고, 차폐체를 사용 후 피폭량의 변화를 관찰하여 방사선 종사자의 피폭 관리에 도움이 되고자 한다. 방사성의약품 투여 시 소요되는 주사시간의 평균을 구하기 위하여 훈련된 주사 담당자가 환자에게 주사하는 시간을 총 50회 측정하였고, 그 평균값(약 2분)을 구하였다. 1 mL주사기에 옥시드로산테크네슘 925 MBq를 0.2 mL 로 맞춘 다음 50 cm, 100 cm, 150 cm, 200 cm에서 방사선 측정기(FH-40, Thermo Scientific, USA)로 선량을 측정하였다. 그리고 방사선차폐체(납 6 mm)를 선원으로부터 25 cm에 설치 한 후 50 cm 거리에서 선량을 측정하였다. 모든 선량측정은 각각 20회에 걸쳐 재현성을 검증하였다. 차폐 전과 차폐 후의 선량의 상관관계는 SPSS (ver. 18)을 사용하여 paired t-test로 검증하였다. 차폐체를 설치하지 않은 선원으로부터 거리에 따른 2분간 받는 피폭량은 50 cm에서 $1.986{\pm}0.052{\mu}Sv$, 100 cm에서 $0.515{\pm}0.022{\mu}Sv$, 150 cm에서 $0.251{\pm}0.012{\mu}Sv$, 200 cm에서 $0.148{\pm}0.006{\mu}Sv$로 나타났다. 차폐를 설치 후 측정 시 피폭량은 $0.035{\pm}0.003{\mu}Sv$로 차폐체 사용 전과 후의 피폭선량은 통계적으로 유의한 차이가 있는 것으로 나타났다($p$<0.001).전신 골스캔은 핵의학 검사에서 많은 비중을 차지하고 있기 때문에 방사성의약품 투여 시 피폭을 줄이기 위해서 외부피폭의 방어원칙을 적절히 병행하여 피폭 저감을 위해 노력해야 한다. 하지만 방사성의약품은 환자에게 직접 투여하기 때문에 선원으로부터 거리를 멀리할 수 없고, 환자의 혈관 확보가 어려운 경우 주사시간이 길어질 수 있다. 본 연구를 통해 거리가 멀어짐에 따라 피폭선량이 감소하는 것을 확인하였고, 선원으로부터25 cm 거리에 차폐체 설치 시 피폭선량이 감소하는 것을 확인할 수 있었다. 본 연구를 통해 방사성의약품 투여 시 차폐체를 사용함으로써 방사선 피폭 저감에 도움이 될 것으로 사료된다.

  • PDF

고에너지 방사선치료에서 차폐물 경계부위의 선량분포에 관한 고찰 (A Study on the dosimetry in boundary of shielding block in high energy irradiation)

  • 김명세;김성규;신세원
    • Journal of Yeungnam Medical Science
    • /
    • 제7권2호
    • /
    • pp.115-120
    • /
    • 1990
  • 18MeV 선형가속기와 코발트 원격치료기를 사용하여 방사선 조사면적 내에 차폐물이 있는 경우, 차폐물에 의한 산란선이 선량분포에 미치는 영향에 관하여 고찰하여 다음과 같은 결과를 얻었다. 1. 차폐물이 이루는 각이 예각일수록 산란선의 효과는 더 크게 나타났다. 2. 차폐물의 넓이가 좁을수록 산란선의 효과는 더 크게 나타났다. 3. 조사면적에 따른 출력특성은 선형적이지만, 차폐물에 의한 출력특성은 조사면적에 대하여 선형가속기는 거의 무관하게 나타났으며, 코발트 원격치료기는 기울기가 적은 선형성을 나타내었다.

  • PDF

Multimedia 기기에의 적용을 위한 CFRTP에 대한 전자파 특성의 평가 (The Evaluation of the Characteristics of Electromagnetic Waves on CFRTP for Multimedia Instrument Applications)

  • 김동진
    • 한국전자파학회논문지
    • /
    • 제8권3호
    • /
    • pp.254-263
    • /
    • 1997
  • 通信 및 電子훌業의 發達에 따라, 電磁波放射에 對한 밟素鐵維彈化樹(CFRTP)의 電磁波 避廠效果(SE)를 冊究하는 것은 重要하다. 本R究에서는 밟素熾維(CF)의 避빼옷效果를 電波8홉室內에서, 驗的으로 測定하였다. 使用한 樹服는 PC, PP, PEl, PMMA 및 PA이다. 實嚴은 分光分析器에 의해 鋼避蘇箱子와 모노폴안테나를 使用해 修行하였다. 훌훌結果로부터 CF는 良好한 電磁波適嚴材의 한 候補임을 알 수 있었다. SE는 CF의 積層의 增加에 따라 增加하였다. 徵小한 揚傷의 增加는 CF의 平面密度, 透過두께 및 反射角의 增加로 인해 SE를 增加 시켰다. SE에 미치는 다른 特性들은 母材樹服, 안테나問의 距離 및 노이즈의 周波數에 따라 달랐다.

  • PDF

일반영상 검사 시 몬테칼로 시뮬레이션을 이용한 3D 프린팅 차폐기구의 효용성 평가 (Evaluation of the Effectiveness of 3D Printing Shielding Devices using Monte Carlo Simulation in Plain Radiography)

  • 조용인;김정훈
    • 한국방사선학회논문지
    • /
    • 제14권3호
    • /
    • pp.303-311
    • /
    • 2020
  • 일반영상 검사 시 발생되는 산란선은 검사목적 부위 외 다른 장기 및 조직에 대해 2차적인 피폭을 유발할 수 있다. 현재 방사선 피폭을 저감하기 위해 사용되는 차폐기구는 종사자들의 방사선 방호 목적으로 대부분 사용되며, 환자의 방사선 방호는 거의 이뤄지지 않고 있다. 이에 본 연구에서는 모의실험을 통해 일반 영상 검사 시 산란선에 의한 장기 선량과 3D 프린팅 재료를 통한 방사선 차폐기구로의 효용성을 평가하고자 한다. 그 결과, 검사 시 장기별 흡수선량은 선원과의 거리가 인접하고, 피부표면에 근접한 장기일수록 2차 산란선에 의해 높은 영향을 나타내었다. 이를 방호하기 위한 3D 프린팅 차폐기구 사용에 따른 선량감소효과는 플라스틱 계열에 비해 혼합 프린팅 재료의 경우 더 높은 차폐효과를 나타내었다.