• 제목/요약/키워드: Shielding cable

검색결과 32건 처리시간 0.015초

도전성 및 자성 차폐체의 차폐효과 해석과 차폐인수 산정 (Analysis of Shielding Effectiveness and Estimation of Shielding Factor in Conductive and Magnetic Shields)

  • 강대하
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.30-40
    • /
    • 2013
  • In this study the method based on flux linkage in cell was introduced in calculation of eddy currents by cell method. According to this method eddy current distribution and the loss can be evaluated and since the shielding effectiveness by flux cancelation of eddy current can be analyzed, this method is applicable to design of conductive shield. And also the formula of shielding factor were so deduced as to be applicable to finite-width infinite-length shielding sheets and infinite-length underground cable shield. These formula are adaptable to magnetic materials as well as conductive materials. As the results of calculation in model shields are follows. In case of finite-width infinite-length shielding sheet, shielding effectiveness increases with increasing of conductivity. In case of infinite-length underground cable shield, the effectiveness become higher with increasing of permeability. Especially the effectiveness is very high in materials with both high conductivity and permeability in underground cable shield.

고효율 자동차용 고전압 케이블의 차폐특성에 관한 연구 (A Study on Shielding characteristics of Cable used in High-efficiency Automobile)

  • 이봉이;이상선;윤승훈;연복희;박경훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1892-1893
    • /
    • 2007
  • Because High efficiency electric vehicles use electrical energy by an power source, radiated noise at high voltage cable bring on problems at other electric/electronic components. But, in order to insure shielding effectiveness increasing braid density infinitely, it is possible that the cost is more than one third of cost of manufacturing cable. Accordingly in this paper, we studied design of cost-effective and light shield cable using dual shielding system of braid and al-foil.

  • PDF

Feasibility study on the inductive fault current limiting cable

  • Lee, Sang Yoon;Choi, Jongho;Kim, Dong Min;Sim, Kideok;Cho, Jeonwook;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.24-28
    • /
    • 2013
  • Fault current limiting (FCL) cable is a kind of superconducting cable which has a function of limiting the fault current at the fault of power grid. The superconducting cable detours the fault current through its stabilizer to keep the temperature as low as possible. On the other hands, the FCL cable permits the temperature rise within some acceptable limit and the fault current is limited by the consequent increase of the resistance of superconducting cable. This kind of FCL cable is called 'resistive FCL cable' because it uses resistive impedance to limit the fault current. In this paper, we suggest a novel concept of FCL cable, which is named as 'inductive FCL cable'. The inductive FCL cable is similar as the magnetic shielding fault current limiter in its operating mechanism. The magnetic field of superconducting cable is almost perfectly shielded by the induced current at the shielding layer during its normal operation. However, at the fault condition, quench occurs at the shielding layer by the induced current higher than its critical current and the magnetic field is spread out of the shielding layer. It will induce additional inductive impedance to the superconducting cable and the inductive impedance can be increased more by installing some material with high magnetic susceptibility around the superconducting cable. We examined the feasibility of inductive FCL cable with simple elemental experiments. The current limiting performance of inductive FCL cable was estimated considering an arbitrary power grid and its fault condition.

EN50289 동축케이블 전달 임피던스 측정 방법을 이용한 통신 케이블의 차폐 효과 분석 (Shielding Effect Analysis of Communication Cables Using EN50289 for Transfer Impedance Measurement of Coaxial Cable)

  • 이근봉;장난;전지운;송승제;나완수
    • 한국전자파학회논문지
    • /
    • 제25권11호
    • /
    • pp.1156-1163
    • /
    • 2014
  • 본 논문에서는 EN50289 규격에 따른 동축케이블의 전달 임피던스 측정을 이용하여 여러 가지 통신 케이블의 차폐 특성을 분석하였다. EN50289 규격에서의 전달 임피던스 측정 방법은 CENELEC(European Committee For Electrotechnical Standardization)에서 규정한 Triaxial 방법이며, IEC Standard 96-1에서 규정한 Triaxial 방법과 달리 측정하고자 하는 동축케이블과 외부 도체의 직경에 관계없이 동축케이블의 전달 임피던스를 측정할 수 있는 장점이 있다. 본 논문에서는 EN50289 규격에 따른 동축케이블의 전달 임피던스 측정장치를 설계/제작하였으며, 이것을 이용한 실험 결과를 통해 측정 시스템의 신뢰할만한 주파수 대역을 결정하였고, 동축케이블의 쉴딩 기법의 차이에서 오는 영향에 대하여 분석하였다. 전달 임피던스 측정 결과, 케이블의 쉴딩 기법에 따라 전달 임피던스의 상당한 차이가 있음을 보였다. 또한, RG-58 통신용 케이블의 전달 임피던스 이론식에 의한 계산값과 측정값의 비교를 통하여 측정된 데이터가 유효함을 보였다.

Shielding Effectiveness of Mesh Screen Filter of Plasma Display Panel

  • Lim, Heon-Yong;Kim, Min-Seok;Lee, Jeong-Hae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.568-570
    • /
    • 2004
  • A shielding effectiveness of mesh screen filter of plasma display panel (PDP) has been calculated in this paper. Since the screen filter is located near the radiation source, the near field wave impedance of the radiation source, i.e., the PDP electrodes, has been considered to calculate the shielding effectiveness. The near field shielding effectiveness of screen filter at 30${\sim}$300 MHz has been estimated to be more than 65${\sim}$80 dB. The measured shielding effectiveness of screen filter is 10${\sim}$50 dB at 30${\sim}$300 MHz[1]. The resulting discrepancy indicates that there are other EMI emission sources such as emission from PCB and cable besides the PDP electrodes.

  • PDF

교류 아크용접기를 사용하는 작업자의 차폐복 재질에 따른 자계저감 특성검토 (Magnetic Field Reduction Characteristics of Shielding Wear Materials for Workers Using AC Arc Welder)

  • 박준형;민석원;이승호
    • 전기학회논문지
    • /
    • 제59권7호
    • /
    • pp.1265-1271
    • /
    • 2010
  • Power cable of an AC arc welder can surround a body of worker at the moment of welding. Applying the boundary element method, we calculated current densities induced in organs inside a worker to study the magnetic field reduction characteristics of shielding wear materials. We knew shielding wear with high permeability materials lowers current density more than high conductivity materials. We also found current density was lowest when high permeability materials were inside high conductivity materials in double layer shielding wear.

154kV, 1GVA 초전도케이블 설계 (Design of 154kV, 1GVA HTS Cable)

  • 조전욱;심기덕;김석호;이수길;장현만;최창열;이근태;양병모;김성래
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.192-192
    • /
    • 2010
  • DAPAS (Development of Advanced Power system by Applied Superconductivity technologies) program that the, superconductivity national program has been started one of the 21C frontier programs from 2001 in Korea. The 3rd phase of DAPAS program was started at April 2007, and the ultimate goal of HTS cable project is to develop 154kV, 1GVA class HTS cable. The structure of 154kV, 1GVA HTS cable is single core with cold dielectric insulation. The cable core consists of the former, conduction layer, electrical insulation layer, shielding layer. The cable cryostat consists of two corrugated seamless aluminum tubes as its high sealing reliability, the tubes separated through a spacer arrangement. Outdoor termination was developed by LS cable and cryogenic system by CVE for 154kV, 1GVA class HTS cable. The 154kV, 1GVA HTS cable will be installed and be tested in KEPCO Gochang Testing Center from June 2010.

  • PDF

통신케이블 차폐시험방법의 유효성 확인 및 측정불확도 추정 (Validation and Measurement Uncertainty Estimation in the Testing Method of Cable-harness Shielding Effectiveness)

  • 김종상;조남호
    • 한국컴퓨터정보학회논문지
    • /
    • 제7권1호
    • /
    • pp.8-19
    • /
    • 2002
  • 시험기관은 표준화되지 않은 시험방법. 해당기관이 설계/개발한 방법 등에 의한 시험을 수행할 경우 방법의 유효성이 확인되어야만 사용할 수 있으며, 또한 측정값에 대한 불확도(Uncertainty)의 추정이 요구되고 있다. 따라서 케이블-하네스의 EMI 차폐효과시험방법에 대한 측정정밀도를 통계적 분석 방법 에 의거 검토하여 유효성을 확인하는 방법을 제시하고 시험결과에 대한 측정불확도를 추정하는 방법을 제시하였다.

  • PDF

전력 유도 발생 시 케이블 쉬스 접지 여부에 따른 유도 잡음 전압 영향 분석 (Analysis on the Effects of the Induced Noise Voltage with the Grounded or Non-grounded Cable Sheath in the Power Inducting Situation)

  • 이상무;최문환;조평동
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.285-288
    • /
    • 2007
  • This article presents the change characteristics of induced noise whether the sheath layer of the cable is grounded or not. As what affects the induced noise, there are power influence or longitudinal transverse voltages and its weighted filtered voltage. The sheath ground is basicaly predicted to have the effects of alleviation on the power influence. But practically the effects may not happen in the case of common cable's sheath layer. Rather there are cases that the ground of sheath affects so that the noise level could increase. So we need to scrutinize the effects of the sheath gorund in the measures for the protection against electromagnetic induction by powerline or traction line system. And the evaluation of using the designated shielding purpose cable is needed.

  • PDF

FDTD Analsysis of Lightning-Induced Voltages on Shielded Telecommunication Cable with Multipoint Grounding

  • Ju, Jae-Cheol;Lee, Hyun-Young;Park, Dong-Chul;Chung, Nak-Sam
    • Journal of electromagnetic engineering and science
    • /
    • 제1권1호
    • /
    • pp.88-94
    • /
    • 2001
  • In this paper, the lightning-induced voltages on shielded twisted-pair wires with multipoint grounding on cable sheath are calculated by using finite-difference time domain (FDTD) method. The equivalent single-wire line that represents a bundle of twisted-pair wires is adopted for computational efficiency. A finitely conducting ground is also taken into account in both lightning electromagnetic field calculations and surge propagation along the shielded cable for a practical simulation. It is found that multipoint additional grounding on cable sheath provides more shielding effectiveness especially in the early time response of the lightning-induced voltages. From this study, the requirements for lighting surge protection devices in a telecommunication subscriber cab1e can be established.

  • PDF