• Title/Summary/Keyword: Shielding Materials

Search Result 553, Processing Time 0.027 seconds

Electromagnetic Wave and EMF Attenuation by Shielding Materials in home appliances (가전제품 전자파 현황 및 차폐재에 의한 감쇄 효과)

  • Cho, Jae-Cheol;Park, Jae-Hwan
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.711-718
    • /
    • 2019
  • Spectrum analyzer and electromagnetic field meter were used to investigate the EM generation behaviour in different types of home electrical appliances. During microwave oven operation, the EM power measured at a point 30cm apart was measured in the range of 8~11mW/㎡, the strength of the low frequency magnetic field was 60~80mG and the electric field strength was measured at 150~160V/m. For smart phone wireless charging pad, it was measured at an electromagnetic power of 0.4mW/㎡, an electric field of 160 V/m and a magnetic field of 1mG at a point 10cm away. For microwave oven and wireless charging pad, if used within 10cm, the size of the electric field has been measured at a large value that exceeds the human body protection standard and may be hazardous to humans. On the other hand, home appliances such as TVs, hairdryers and refrigerators all showed very low levels of electromagnetic waves, electric fields and magnetic fields, with no harmful effects seen. For electromagnetic shielding, the metal Cu fabric and metal foil had a high level of EM shielding, while polymer films had a low EM shielding characteristic.

Energy build-up factors estimation for BaZr0.10Ti0.90O3, Ba0.90La0.10TiO3 and Ba0.90La0.10Zr0.10Ti0.90O3 ceramics in shielding applications

  • Sarabjeet Kaur;Vidushi Karol;Pankaj Kumar;Gurpreet Kaur;Prianka Sharma;Amandeep Saroa;Amrit Singh
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1822-1829
    • /
    • 2024
  • The search for materials that serve as good shields for radiation has become very important in light of the increasing exposure to ionizing radiation in various vital sectors. The aim is to search for novel materials with better radiation shielding properties that are stable, nontoxic, and abundant and environment friendly. The solidstate reaction approach has been used to synthesize a few ceramics, including BaZrXTi1-XO3, Ba1-XLaXTiO3 and Ba1-XLaXZrXTi1-XO3 (with x = 0.10) i.eBaZr0.10Ti0.90O3 (BZT), Ba0.90La0.10TiO3 (BLT), and Ba0.90La0.10Zr0.10Ti0.90O3 (BLZT). The density of the prepared samples varies from 6.3471 to 11.6003 g/cm3. The X-ray diffraction technique, shows strong peaks to confirm the crystalline structure of prepared ceramic samples. Using the G-P fitting approach, the advanced radiation shielding parameters (build-up factor) have been evaluated in the photon energy region of 1.5 keV-15 MeV. It is observed from the results that exposure buildup factor (EBF) and energy absorption buildup factor (EABF) are maximum for BLZT and has the minimum value for BZT in the entire photon energy regime. The results of this work should be useful in radiation shielding applications such as in industry, medicine, and nuclear engineering.

A Study on Reduction of Radiation Exposure by Nuclear Medicine Radiation Workers (핵의학 방사선 작업종사자 피폭 감소 방안에 대한 연구)

  • Lee, Wanghui;Ahn, Sungmin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.271-281
    • /
    • 2019
  • This study investigated the shielding efficiency of various types of shielding materials and measured the dose by organ using the phantom. Results of Shielding Efficiency Measurement Using Personal Radiation Meter. Among the various shielding materials, 1.1 mm RNS-TX composed of nano tungsten showed the highest shielding efficiency and 0.2 mm lead shielding showed the lowest shielding efficiency. 99mTc 30 mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 20.53 mSv without radiation protective clothing, 8.75 mSv when wearing 0.25 mm Pb protective clothing, 6.03 mSv when wearing 0.5 mm Pb protective clothing. 131I 2 mCi mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 7.71 mSv without radiation protective clothing, 4.88 mSv when wearing 0.25 mm Pb protective clothing, 2.79 mSv when wearing 0.5 mm Pb protective clothing. 18F 5 mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 16.39 mSv without radiation protective clothing, 15.84 mSv when wearing 0.25 mm Pb protective clothing, 12.52 mSv when wearing 0.5 mm Pb protective clothing. None of the radiation workers working in the nuclear medicine department exceeded the dose limit. However, when compared with other workers in the hospital, they showed a relatively high dose. Therefore, it is necessary to prepare measures to reduce and manage the dose of radiation workers in the nuclear medicine department through the wearing of radiation protective clothing made of lightweight, shielding material with good shielding efficiency, circulation task, task sharing, and substitution equipment such as auto dispenser.

Dispersion Characteristics of Magnetic Particle/Graphene Hybrid Based on Dispersant and Electromagnetic Interference Shielding Characteristics of Composites (분산제에 따른 자성금속 무전해도금 기반 그래핀 분산 특성 및 복합재의 전자파 차폐 특성 연구)

  • Lee, Kyunbae;Lee, Junsik;Jung, Byung Mun;Lee, Sang Bok;Kim, Taehoon
    • Composites Research
    • /
    • v.31 no.3
    • /
    • pp.111-116
    • /
    • 2018
  • In this paper, magnetic FeCoNi particles have been grown through electroless plating on the surface of graphene, and then this hybrid material has been dispersed by various surfactants to prepare films. The pyridine surfactant shows the highest dispersability and low surface resistance value (351 Ohm/sq) and the electromagnetic shielding ability at the frequency of 10 GHz. Specially, the evaporation of the pyridine during the drying process could be able to form the internal conductive network and high dispersion of FeCoNi on the surface of graphene.

Effect of Nitrogen Volume in Ar-N2 Shielding Gas on Microstructure and Hardness of GTA Welded Pure Ti (순 Ti GTA 용접부의 미세조직과 경도에 미치는 Ar-N2 보호가스 중 질소량의 영향)

  • An, Hyun-Jun;Jeon, Ae-Jeong;Hong, Jae-Keun;Jeong, Bo-Young;Lee, Jong-Sub;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.30 no.2
    • /
    • pp.70-75
    • /
    • 2012
  • In this study, effect of nitrogen volume in the shielding gas of Ar-$N_2$ mixing gas on the bead shape, hardness and microstructure of GTA welds of 3mm thick Commercial Pure Ti was investigated. As the nitrogen volume increased, the welding current for full penetration was reduced and hardness in the fusion zone significantly increased compared with that of the base metal, but there is no difference in the hardness of HAZ. Microstructure in the fusion zone with pure Ar gas changed from equiaxed alpha of the base metal to serrated alpha. On the other hand, microstructure using Ar-$N_2$ mixing gas changed to acicular alpha. With the increasing of nitrogen content, the amount of acicular alpha increased and the size of that was fine.

Development of high-performance heavy density concrete using different aggregates for gamma-ray shielding

  • Ouda, Ahmed S.
    • Advances in materials Research
    • /
    • v.3 no.2
    • /
    • pp.61-75
    • /
    • 2014
  • This study aimed to investigate the suitability of some concrete components for producing "high-performance heavy density concrete" using different types of aggregates that could enhances the shielding efficiency against ${\gamma}$-rays. 15 mixes were prepared using barite, magnetite, goethite and serpentine aggregates along with 10% silica fume, 20% fly ash and 30% blast furnace slag to total OPC content for each mix. The mixes were subjected to compressive strength at 7, 28 and 90 days. In some mixes, compressive strengths were also tested up to 90 days upon replacing sand with the fine portions of magnetite, barite and goethite. The mixes containing magnetite along with 10% SF reaches the highest compressive strength exceeding over M60 requirement by 14% after 28 days. Whereas, the compressive strength of concrete containing barite was very close to M60 and exceeds upon continuing for 90 days. Also, the compressive strength of high-performance concrete incorporating magnetite fine aggregate was significantly higher than that containing sand by 23%. On the other hand, concrete made with magnetite fine aggregate had higher physico-mechanical properties than that containing barite and goethite. High-performance concrete incorporating magnetite fine aggregate enhances the shielding efficiency against ${\gamma}$-rays.

Development of Heat Shielding Part for RFID Tag using Porous Aluminum Alloy (알루미늄 다공성소재를 이용한 RFID Tag용 열차폐부품 개발)

  • Bang, Jae-Oh;Lee, Hyo-Soo;Jung, Taek-Kyun;Lee, Min-Ha;Kim, Bum-Sung;Jung, Seung-Boo
    • Journal of Powder Materials
    • /
    • v.18 no.2
    • /
    • pp.135-140
    • /
    • 2011
  • The RFID (Radio-Frequency Identification) is an automatic identification method, relying on storing and remotely retrieving data using devices called RFID tags or transponders. Some RFID tags have been used in severe environment of temperature ranged from $200^{\circ}C$ to $250^{\circ}C$ for a long time and may cause serious problems such as signal error, short life cycle and explosion. Conventionally, the RFID tags for high temperature applications consisted of Fe-alloy housing part, ceramic powder and RFID sensor. However, it has disadvantage of heavy weight, signal noise and heat shield capability. In this study, we newly applied the aluminum porous materials fabricated by polymer leaching process into RFID tags in order to improve heat shielding ability, and compared the properties of RFID tag inserted by aluminum porous with the conventional one.

The Effect of Heat Input and Shielding Gas Composition on Corrosion Resistance of TIG Weld Metal of New Lean Duplex Stainless Steel S82441

  • Niagaj, J.;Brytan, Z.
    • Corrosion Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.278-284
    • /
    • 2017
  • The effects of TIG welding and post-treatment procedures on the microstructure and the pitting corrosion resistance of welded lean duplex stainless steel S82441 were investigated. Autogenous TIG welding was used with different amounts of heat input and shielding gases such as Ar, and mixtures of $Ar-N_2$ and Ar-He. The addition of 5% to 15% of nitrogen to argon practically did not affect the level of the pitting corrosion resistance. However, the application of gas mixtures (50% Ar + 50% He) resulted in a significant decrease in pitting corrosion resistance. We found that increased current (200 A and 250 A) led to lower values of CPT of welds compared with welds obtained with 50 A, 100 A and 150 A. In addition, the removal of the weld surface layer (0.2 ~ 0.3 mm thickness) in most cases not only resulted in a significant increase in resistance to the pitting corrosion but also post-treatment of weld, implying that corrosion resistance depended on factors such as surface roughness or the presence of undesirable oxides.

A Study of Shielding Properties of X-ray and Gamma in Barium Compounds

  • Seenappa, L.;Manjunatha, H.C.;Chandrika, B.M.;Chikka, Hanumantharayappa
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.26-32
    • /
    • 2017
  • Background: Ionizing radiation is known to be harmful to human health. The shielding of ionizing radiation depends on the attenuation which can be achieved by three main rules, i.e. time, distance and absorbing material. Materials and Methods: The mass attenuation coefficient, linear attenuation coefficient, Half Value Layer (HVL) and Tenth Value Layer (TVL) of X-rays (32 keV, 74 keV) and gamma rays (662 keV) are measured in Barium compounds. Results and Discussion: The measured values agree well with the theory. The effective atomic numbers ($Z_{eff}$) and electron density (Ne) of Barium compounds have been computed in the wide energy region 1 keV to 100 GeV using an accurate database of photon-interaction cross sections and the WinXCom program. Conclusion: The mass attenuation coefficient and linear attenuation coefficient for $BaCO_3$ is higher than the $BaCl_2$, $Ba(No_3)_2$ and BaSO4. HVL, TVL and mean free path are lower for $BaCO_3$ than the $BaCl_2$, $Ba(No_3)_2$ and $BaSO_4$. Among the studied barium compounds, $BaCO_3$ is best material for x-ray and gamma shielding.

Radiation protective qualities of some selected lead and bismuth salts in the wide gamma energy region

  • Sayyed, M.I.;Akman, F.;Kacal, M.R.;Kumar, A.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.860-866
    • /
    • 2019
  • The lead element or its salts are good radiation shielding materials. However, their toxic effects are high. Due to less toxicity of bismuth salts, the radiation shielding properties of the bismuth salts have been investigated and compared to that of lead salts to establish them as a better alternative to radiation shielding material to the lead element or its salts. The transmission geometry was utilized to measure the mass attenuation coefficient (${\mu}/{\rho}$) of different salts containing lead and bismuth using a high-resolution HPGe detector and different energies (between 81 and 1333 keV) emitted from point sources of $^{133}Ba$, $^{57}Co$, $^{22}Na$, $^{54}Mn$, $^{137}Cs$, and $^{60}Co$. The experimental ${\mu}/{\rho}$ results are compared with the theoretical values obtained through WinXCOM program. The theoretical calculations are in good agreement with their experimental ones. The radiation protection efficiencies, mean free paths, effective atomic numbers and electron densities for the present compounds were determined. The bismuth fluoride ($BiF_3$) is found to have maximum radiation protection efficiency among the selected salts. The results showed that present salts are more effective for reducing the intensity of gamma photons at low energy region.