• 제목/요약/키워드: Shear strengths

검색결과 693건 처리시간 0.034초

대형삼축압축시험 및 대형직접전단시험에 의한 사석재료의 전단강도 평가 (Comparison of Shear Strengths of Crushed Rock Determined by Large Triaxial Test and Direct Shear Test)

  • 신동훈;안태봉;이경필;이한출
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.259-264
    • /
    • 2002
  • In this study the shear strengths of a poorly grad ed rock material(d/sub max/≤50.8mm, C/sub u/=1.86) were determined by large direct shear test and large triaxial test. The obtained stress-strain curves by the above large shear tests for the rock materials are similar to the loose sand's or normally consolidated clay's curve, in which the peak strength does not appear obviously. And for the uniformly graded rock material the shear strength by large direct shear test may be overestimated around 1.54∼1.70 times that of large triaxial test.

  • PDF

화학중합형 및 광중합형 레진접착제가 금속 및 도재브라켓의 전단결합강도에 미치는 영향 (EFFECTS OF CHEMICALLY CURED RESIN AND LIGHT CURED RESIN ON SHEAR BOND STRENGTH OF METAL BRACKET AND CERAMIC BRACKET)

  • 윤덕상;이기수
    • 대한치과교정학회지
    • /
    • 제24권1호
    • /
    • pp.125-134
    • /
    • 1994
  • This study was designed for comparison of shear bond strengths and failure patterns of four experimental groups which combinated mesh-backed metal brackets and texture based ceramic brackets (Transcend series $2000^{(TM)}$) with chemically cured resin (Mono $Lok2^{(TM)}$) and visible light cured resin $(Transbond^{(TM)})$. Brackets were bonded on the extracted human bicuspids, after etching them by manufacturer's recommand, and the shear bond strengths were measured on the Instron machine after 24 hrs passed in the $37^{\circ}C$ water bath. The results were as follows. 1. Ceramic brackets, transcend series $2000^{(TM)}$, bonded with $MonoLok2^{(TM)}$ showed statistically higher shear bond strength than mesh-backed metal brackets bonded with $MonoLok2^{(TM)}$. 2. There was no significant difference in shear bond strengths between metal and ceramic brackets bonded with $(Transbond^{(TM)})$. 3. Ceramic brackets bonded with both $(Transbond^{(TM)})$) and $MonoLok2^{(TM)}$ showed primarily fractures between brackets adhesive interface. 4. Enamel crack was not found in anyone specimen.

  • PDF

복합적 환경인자의 영향에 의한 접착제의 접착전단강도 및 화학구조 변화 (Effect of Combined Environmental Factors on Adhesive Shear Strengths and Chemical Structures of Adhesives)

  • 황영은;윤성호
    • Composites Research
    • /
    • 제24권1호
    • /
    • pp.31-36
    • /
    • 2011
  • 본 연구에서는 유도무기의 탐색기에 적용되는 지존 접착제의 대체 가능성을 조사하기 위해 환경인자의 노출시간에 따른 기존 접착제와 대제 접착제의 접착전단장도들을 평가하고 이들의 화학구조 변화를 조사하였다. 이때 접착제는 기존 접착제와 대체 접착제에 대해 각각 구조용 접착제와 실링용 접착제의 두 종류를 고려하였다. 이들 접착제는 온도, 수분, 자외선 등의 복합적인 환경인자에 최대 1000시간 동안 노출시켰다. 환경인자의 노출시간에 따른 접착제의 접착전단강도를 평가하기 위해 접착전단시험을 수행하고 화학구조 변화를 조사하기 위해 ATR 적외선 분광분석을 수행하였다. 연구결과에 따르면 대체 접착제의 접착전단강도는 기존 접착제의 경우에 비해 높으며 환경인자의 노출에도 매우 안정적으로 나타나 대체 접착제는 기존 접착제의 대체용으로 적용이 가능함을 알 수 있었다.

수침 및 교란 효과에 따른 풍화잔적토의 전단강도 특성 (The Characteristics of Shear Strength on Weathered Residual Soils for the Effect of Soaking and Disturbance)

  • 오세붕;정종혁;이영휘
    • 한국지반공학회논문집
    • /
    • 제15권5호
    • /
    • pp.125-139
    • /
    • 1999
  • 풍화잔적토는 불교란 시료를 채취하기가 곤란하기 때문에 전단강도를 산정하는데 있어서 어려움을 겪고 있다 본 연구에서는 직접 전단시험용 불교란 시료를 용이하게 채취하기 위해서 슈 장착 직접 전단상자를 개발하였으며, 성공적으로 불교란 시료를 채취할 수 있었다. 채취된 분교란 시료의 직접 전단시험을 통해서 포화조건에 따른 전단강도의 변화를 규명하였다. 그리고 교란에 따른 풍화잔적토의 전단거동을 규명하기 위해서 정적시료 성형장치를 제작하였고, 자연함수비 상태에서는 교란에 따른 강도저하가 나타나지만, 수침시에는 강도가 유사함을 확인하였다. 불교란 시료에 대해서 직접전단시험과 삼축압축시험시의 강도를 비교한 결과, 직접 전단시험시 수침시료의 강도가 삼축압축시험의 결과와 유사한 경향을 나타내었다. 그리고 대상 붕괴사면에 대한 역해석을 수행한 결과, 슈 장착 직접 전단상자를 이용하면 풍화잔적토 사면에서의 전단강도 산정이 가능하리라고 판단되었다.

  • PDF

The effect of repeated bonding on the shear bond strength of different resin cements to enamel and dentin

  • Bulut, Ali Can;Atsu, Saadet Saglam
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.57-66
    • /
    • 2017
  • PURPOSE. Cementation failures of restorations are frequently observed in clinical practice. The purpose of this study is to compare the effect of initial and repeated bonding on the bond strengths of different resin cements to enamel and dentin. MATERIALS AND METHODS. Ninety human maxillary central incisors were bisected longitudinally. The 180 tooth halves were divided into 2 groups (n = 90) for enamel and dentin bonding. The enamel and dentin groups were further divided into 3 groups (n = 30) for different resin cement types. Composite resin (Filtek Ultimate) cylinders ($3{\times}3\;mm$) were prepared and luted to enamel and dentin using Variolink II (Group V), RelyX ARC (Group R), or Panavia F 2.0 (Group P) resin cement. After 24 hours, initial shear bond strengths of the resin cements to enamel and dentin were measured. Using new cylinders, the specimens were de-bonded and re-bonded twice to measure the first and the second bond strengths to enamel and dentin. Failure modes and bonding interfaces were examined. Data were statistically analyzed. RESULTS. Initial and repeated bond strengths to enamel were similar for all the groups. The first ($15.3{\pm}2.2\;MPa$) and second ($10.4{\pm}2.2\;MPa$) bond strengths to dentin were significantly higher in Group V (P<.0001). Second bond strengths of dentin groups were significantly lower than initial and first bond strengths to dentin (P<.0001). CONCLUSION. All resin cements have similar initial and repeated bond strengths to enamel. Variolink II has the highest first and second bond strength to dentin. Bond strength to dentin decreases after the first re-bonding for all resin cements.

상아질 표면처리후 복합레진 수복시 온도변화가 결합에 미치는 영향 (EFFECT OF THERMOCYCLING ON BONDING OF COMPOSITE RESIN AFTER DENTIN SURFACE TREATMENTS)

  • 이용우;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.126-142
    • /
    • 1991
  • The purpose of this study was to evaluate the effect of various dentin surface treatments on shear bond strength, microhardness and fracture mode before and after thermocycling. Recently extracted 75 human molars were used. The teeth were sagittal sectioned faciolingually to obtain 150 specimens. They were randomly divided into six groups. Mesial and distal dentinal surfaces of specimens were exposed by grinding and treated respectively with GC-DENTIN CONDITIONER. 10-3 solution of 4-Meta, Cleansar and Primer of GLUMA, Scotchprep of Scotchbond 2, DENTIN CONDITIONER and PRIMER A, B of ALL BOND according to the manufacturers directions. Specimens of one group were not treated. Adhesive agent of Scotchbond 2, were applied and cured on the treated dentin surfaces. After P-50 were cured on them, specimens were stored in 31c water for 24 hours before shear bond strength measurement Shear bond strength was measured in 10 specimens of each group. 10 specimens of each group were thermocycled in $20^{\circ}C$, $60^{\circ}C$,$20^{\circ}C$, $4^{\circ}C$, $20^{\circ}C$ water in order, for 30 seconds respectively, 100 times a day for 7 days. After thermocycling shear bond strength was measured. Microhardness was checked on treated dentin surface and fractured dentin surface in 10 specimens respectievly. Francture modes were observed with SEM The following results were obtained. 1. Before thermocycling. shear bond strengths in the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND were significantly higher than those in other specimens(P<0.01). 2. After thermocycling. shear bond strengths in the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2 and DENTIN CONDITIONER and PRIMER A, B of AIL BOND were significantly higher than those in specimens not: treated, treated with GC-DENTIN CONDITIONER and 10-3 solution of 4-Meta(P<0.01). Shear bond strengths in the specimens treated with GC-DENTIN CONDITIONER and PRIMER A, B of ALL BOND were significantly higher than those in other specimens except those treated with Scotchprep of Srotchbond 2(P<0.01). 3. Shear bond strengths after thermocycling were reduced in the specimens not treated, treated with GC-DENTIN CONDITIONER and 10-3 solution of 4-Meta and were increased in the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2, without significance, compared with those before thermocycling. In the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND, shear bond strengths after thermocycling were significantly increased, compared with those before thermocycling(P<0.01). 4. Microhardnesses in the fractured surfaces after shear bond strength measurement were significantly increased in the specimens treated with 10-3 solution of 4-Meta and significantly decreased in the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND, compared with those in the treated dentin surfaces(P<0.01). 5. In the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2 and DENTIN CONDITIONER and PRIMER A, B of ALL BOND, cohesive fracture modes were observed more than adhesive fracture modes.

  • PDF

횡 보강된 프리캐스트와 현장타설 콘크리트 합성보의 전단강도 (Shear Strength of PC-CIP Composite Beams with Shear Reinforcement)

  • 김철구;박홍근;홍건호;강수민
    • 콘크리트학회논문집
    • /
    • 제26권2호
    • /
    • pp.189-199
    • /
    • 2014
  • 최근 들어, 압축강도가 서로 다른 프리캐스트 콘크리트와 현장타설 콘크리트의 합성 부재의 사용이 증가하고 있지만 현행 콘크리트 구조기준에는 서로 다른 강도로 복합화된 부재의 수직 전단강도에 대해 검증되지 않은 다양한 계산법들이 제시되어있다. 그래서 이번 연구에서는 기존에 연구되었던 무횡보강 합성보와 같은 철근비와 전단경간비를 갖는 횡보강 합성보의 전단강도 실험을 통해 횡보강 합성 부재의 전단강도에 대해 알아보았다. 변수로는 단면형상, 전단철근 간격, 그리고 전단경간비(a/d)를 고려하였다. 실험 결과와 현행 기준에서 제시하는 합성 부재의 수직전단강도 기준식을 비교하였다. 실험 결과를 분석해보면 횡보강 부재의 수직전단강도는 유효콘크리트 강도와 압축대 콘크리트 강도에 영향을 받았고 휨 균열 강성에 비례하였고 압축대 콘크리트 강도에 따라 전단철근의 기여도의 차이를 보였다.

Direct Shear Test of Retrofit Anchors Using Deformed Reinforcement and Adhesive

  • Choi, Dong-Uk;Kim, Yong-Gon
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.91-99
    • /
    • 2000
  • A new type of retrof=t anchor bolt that uses deformed reinforcing bars and a commercial adhesive was developed and then an experimental study was carried out to determine the behavior of the anchors in direct shear. The steel-to-concl몫ete interface was tested. Plain concrete slabs with about 20-MPa compressive strength were used for 23 direct shear tests performed Test variables were anchor diameters (D16, D22. and D29) and edge effect. Three different shear tests were completed: simple shear, edge shear where anchors were pulled against the concrete core, and edge shear where anchors were pushed against the concrete cover In the simple and the edge shear tests where the anchors were pulled against the core, the theoretical dowel strength determined by (equation omitted) was achieved but with relatively large displacements. The shear resistances increased with the increasing displacements. In the edge shear test where the anchors were pushrd against the cover, the peak shear strengths signif=cantly lower than the theoretical dowel strength were determined due to cracks developed in concrete when the edge distance was 80 mm. The peak strengths were about 50% of the dowel strength for Dl6 bar. and about 25% or less of the dowel strength for D22 and D29 bars. Test results revealed that the edge shear where the anchor was pushed against the cover controled.

  • PDF

새로운 형태의 선설치 인서트 앵커에 대한 단조 인장 및 전단강도 평가 (Tensile and Shear Strengths of New Type of Cast-in-Place Concrete Insert Anchors Under Monotonic Loading)

  • 전주성;김지훈;오창수;이창환
    • 한국공간구조학회논문집
    • /
    • 제21권2호
    • /
    • pp.49-56
    • /
    • 2021
  • The damage to non-structural elements in buildings has been increasing due to earthquakes. In Korea, post-installed anchors produced overseas have been mainly used for seismic anchorage of non-structural components to structures. Recently, a new cast-in-place concrete insert anchor installed in concrete without drilling has been developed in Korea. In this paper, an experimental study was conducted to evaluate the tensile and shear strengths of the newly developed anchor under monotonic load. The failure modes of the tension specimens were divided into concrete breakout failure and steel failure, and all shear specimens showed steel failure. In both tension and shear, the maximum loads of specimens were greater than the nominal strengths predicted by the concrete design code (KDS 14 20 54). As a result, it is expected that the current code can also be used to calculate the strength of the developed cast-in anchor.

Interaction of internal forces of interior beam-column joints of reinforced concrete frames under seismic action

  • Zhou, Hua;Zhang, Jiangli
    • Structural Engineering and Mechanics
    • /
    • 제52권2호
    • /
    • pp.427-443
    • /
    • 2014
  • This paper presents detailed analysis of the internal forces of interior beam-column joints of reinforced concrete (RC) frames under seismic action, identifies critical joint sections, proposes consistent definitions of average joint shear stress and average joint shear strain, derives formulas for calculating average joint shear and joint torque, and reports simplified analysis of the effects of joint shear and torque on the flexural strengths of critical joint sections. Numerical results of internal joint forces and flexural strengths of critical joint sections are presented for a pair of concentric and eccentric interior connections extracted from a seismically designed RC frame. The results indicate that effects of joint shear and torque may reduce the column-to-beam flexural strength ratios to below unity and lead to "joint-yielding mechanism" for seismically designed interior connections. The information presented in this paper aims to provide some new insight into the seismic behavior of interior beam-column joints and form a preliminary basis for analyzing the complicated interaction of internal joint forces.