• Title/Summary/Keyword: Shear Noise

Search Result 428, Processing Time 0.024 seconds

Dynamic Stability Analysis of Thick Plates with Varying Thickness and Concentrated Mass on Inhomogeneous Pasternak Foundation (비균질 Pasternak 지반에 놓인 집중질량을 갖는 변단면 후판의 동적안정해석)

  • Lee, Yong-Soo;Kim, Il-Jung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.8
    • /
    • pp.698-707
    • /
    • 2011
  • This paper is to analyze the stability of the thick plate on inhomogeneous Pasternak foundation, with linearly varying thickness and concentrated mass by finite element method. To verify this finite element method, the results of natural frequencies and buckling stresses by the proposed method are compared with the existing solutions. The dynamic instability regions are decided by the dynamic stability analysis of the thick plate on inhomogeneous Pasternak foundation, with linearly varying thickness and concentrated mass. The non-dimensional Winkler foundation parameter is applied as 100, 1000 and non-dimensional shear foundation parameter is applied as 5. The tapered ratios are applied as 0.25 and 1.0, the ratios of concentrated mass to plate mass as 0.25 and 1.0, and the ratio of in-plane force to critical load as 0.4. As the result of numerical analysis of the thick plate on inhomogeneous Pasternak foundation for $u{\times}v=300cm{\times}300cm$ and $a{\times}b=600cm{\times}600cm$, instability areas of the thick plate which has the larger rigidity of inner area are farther from ${\beta}$-axis and narrower than those which has the larger rigidity of outer area.

Optimal Design of New Magnetorheological Mount for Diesel Engines of Ships (선박용 디젤엔진을 위한 새로운 MR 마운트의 최적설계)

  • Do, Xuan-Phu;Park, Joon-Hee;Woo, Jae-Kwan;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.3
    • /
    • pp.209-217
    • /
    • 2013
  • This paper presents an optimal design of a magnetorheological(MR) fluid-based mount(MR mount) that can be used for to vibration control in diesel engines of ships. In this work, a mount that uses mixed-modes(squeeze mode, flow mode, and shear mode) is proposed and designed. To determine the actuating damping force of the MR mount required for efficient vibration control, the excitation force from a diesel engine is analyzed. In this analysis, a model of a V-type engine is considered. The relationship between the velocity and pressure of gas in terms of the torque acting on the piston is derived. Subsequently, by integrating the field-dependent rheological properties of commercially available MR fluid with the excitation force, the appropriate size of the MR mount is designed. In addition, to achieve the maximum actuating force under geometric constraints, design optimization is undertaken using the ANSYS parametric design language software. Through magnetic density analysis, optimal design parameters such as the bottom gap and radius of coil are determined.

Controller Design of Piezoelectric Milliactuator for Dual Stage System (이중 구동 시스템을 위한 압전 밀리엑추에이터의 제어기 설계)

  • Eo-Jin, Hong;No-Cheol, Park;Hyun-Seok, Yang;Young-Pil, Park
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.12
    • /
    • pp.965-971
    • /
    • 2003
  • To reach high areal density, less track pitch is expected and more servo bandwidth is required. One approach to overcoming the problem is by using dual stage servo system. For this system. we have suggested new milliactuator based on the shear mode of piezoelectric elements to drive the head suspension assembly. In this paper, we introduce milliactuator and controller design method, PQ method. PQ method reduces the controller design problem for DISO (dual-input/single-output) systems to two standard controller design problems for SISO ( single-input/single-output) problems. The first part of PQ method directly addresses the issue of actuator output contribution, and the second part allows the use of traditional loop shaping to achieve the overall system performance. This paper shows how to employ the PQ method to meet aggressive close-loop performance specifications for a disk drive system with a VCM and piezoelectric milliactuator.

Fabrication of Phased Array EMAT and Its Characteristics (위상배열 EMAT의 제작 및 특성 평가)

  • Ahn, Bong-Young;Cho, Seung-Hyun;Kim, Young-Joo;Kim, Ki-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2010
  • EMAT has been applied in various fields for flaw detection and material characterization because it has noncontact property in wave generation and a good mode selectivity. Unfortunately, however, EMAT shows low signal to noise ratio relative to commercial contact transducer because of low energy conversion efficiency. If the phase matching through the control of time delay between each coil consisting of the array EMAT is accomplished, it is expected that it will be a solution for the improvement of low signal to noise ratio. In this experiment, the phased array EMATs which consists of 3 or 4 meander coils and one big magnet were fabricated for surface and vertical shear wave generation. Effect of phased delay control on signal directivity and amplitude enhancement was verified. A slit with the depth of 0.5 mm and a side-drill hole of 0.5 mm diameter were clearly detected by fabricated phased array EMATs, respectively.

Optimal Design of New MR Mount for Diesel Engine of Ship (선박디젤엔진을 위한 새로운 MR 마운트의 최적설계)

  • Do, Xuan-Phu;Park, Joon-Hee;Woo, Jae-Kwan;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.93-99
    • /
    • 2012
  • This paper presents an optimal design of magnetorheological (MR) fluid based mount (MR mount in short) which can be applicable to vibration control of diesel engine of ship. In this work, a mixed - mode including squeeze mode, flow mode and shear mode is proposed and designed. In order to determine actuating damping force of MR mount required for efficient vibration control, excitation force from diesel engine is analyzed. In this analysis, a model of V-type engine is considered and the relationship between velocity and pressure of gas in torque of the piston is derived. Subsequently, by integrating the field-dependent rheological properties of commercially available MR fluid with the excitation force an appropriate size of MR mount is designed. In addition, in order to achieve maximum actuating force with geometric constraints design optimization is undertaken using ANSYS software. Through the magnetic density analysis, optimal design parameters such as bottom gap and radius of coil are determined.

  • PDF

Development of An Integrated Optimal Design Program for Design of A High-Efficiency Low-Noise Regenerative Fan (재생형 송풍기의 고효율 저소음 설계를 위한 통합형 최적설계 프로그램 개발)

  • Heo, Man-Woong;Kim, Jin-Hyuk;Seo, Tae-Wan;Koo, Gyoung-Wan;Lee, Chung-Suk;Kim, Kwang-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.1
    • /
    • pp.35-40
    • /
    • 2014
  • A multi-objective optimization of a regenerative fan for enhancing the aerodynamic and aeroacoustic performance was carried out using an integrated fan design system, namely, Total FAN-Regen$^{(R)}$. The Total FAN-Regen$^{(R)}$ was developed for non-specialists to carry out a series of design process, viz., computational preliminary design, three-dimensional aerodynamic and aeroacoustic analyses, and design optimization, for a regenerative fan. An aerodynamic analysis of the regenerative fan was conducted by solving three-dimensional Reynolds-averaged Navier-Stokes equations using the shear stress transport turbulence model. And, an aeroacoustic analysis of the regenerative fan was implemented in a finite/infinite element method by solving the variational formulation of Lighthill's analogy based on the results of the unsteady flow analysis. An optimum shape obtained by Total FAN-Regen$^{(R)}$ shows the enhanced efficiency and decreased sound pressure level as much as 1.5 % and 20.0 dB, respectively, compared to those of the reference design. The performance test was carried out for an optimized regenerative fan to validate the performance of the numerically predicted optimal design.

Development of a Nonlinear SI Scheme using Measured Acceleration Increment (측정 가속도 증분을 사용한 비선형 SI 기법의 개발)

  • Shin, Soo-Bong;Oh, Seong-Ho;Choi, Kwang-Hyu
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.6 s.40
    • /
    • pp.73-80
    • /
    • 2004
  • A nonlinear time-domain system identification algorithm using measured acceleration data is developed for structural damage assessment. To take account of nonlinear behavior of structural systems, an output error between measured and computed acceleration increments has been defined and a constrained nonlinear optimization problem is solved for optimal structural parameters. The algorithm estimates time-varying properties of stiffness and damping parameters. Nonlinear response of restoring force of a structural system is recovered by using the estimated time-varying structural properties and computed displacement by Newmark-$\beta$ method. In the recovery, no pre-defined model for inelastic behavior has been assumed. In developing the algorithm, noise and incomplete measurement in space and state have been considered. To examine the developed algorithm, numerical simulation and laboratory experimental studies on a three-story shear building have been carried out.

A Study on the Skin Friction Characteristics of SIP and Numerical Model of the Interface Between SIP and Soils (SIP말뚝의 주면마찰특성 및 주면 경계요소의 수치모델에 관한 연구)

  • 천병식;임해식
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.247-254
    • /
    • 2003
  • While the interests in the environmental problem during the construction are increasing, the use of low noise-vibration auger-drilled pilling is increasing to solve noise and vibration problem in pilling. Therefore, in Korea, SIP (Soil-Cement Injected Precast Pile) method is mainly used as auger-drilled pilling. However, there is no proper design criteria compatible with the ground condition of Korea, so which is most wanted. To improve and supplement this situation, direct shear tests for the friction between SIP pile skin interface and soil were executed on various conditions. Through the analysis of test results, skin friction characteristics of SIP were investigated thoroughly Also, hyperbolic model parameter fomulas which describe the friction behavior and the new non-linear unit skin friction capacity model with SM, SC soil were suggested.

Transient Response of a Crack in a Functionally Graded Piezoelectric Strip between Two Dissimilar Piezoelectric Strip (두 개의 서로 다른 압전재료층 사이의 기능경사압전재료 접합층 내부 균열에 대한 과도응답 해석)

  • Shin, Jeong Woo;Lee, Young-Shin;Kim, Sung Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.206-213
    • /
    • 2013
  • Transient response of a crack in a functionally graded piezoelectric material (FGPM) interface layer between two dissimilar homogeneous piezoelectric layers under anti-plane shear is analyzed using integral transform approaches. The properties of the FGPM layer vary continuously along the thickness. Laplace and Fourier transforms are used to reduce the problem to two sets of dual integral equations, which are then expressed to the Fredholm integral equations of the second kind. Numerical values on the dynamic energy release rate (DERR) are presented for the FGPM to show the effects on electric loading, gradient of the material properties, and thickness of the layers. Computed results yield following conclusions: (a) the DERR increases with the increase of the gradient of the material properties of the FGPM layer; (b) certain direction and magnitude of the electric impact loading impedes crack extension; (c) increase of the thickness of the FGPM layer and the homogeneous piezoelectric layer which has larger material properties than those of the crack plane are beneficial to increase of the resistance of transient fracture of the FGPM layer.

  • PDF

H/V Spectral-ratio Analysis of Microtremors in Jeju Island (제주도 상시미동의 H/V 스펙트럼비 분석)

  • Hong, Myung-Ho;Kim, Ki-Young
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.2
    • /
    • pp.144-152
    • /
    • 2010
  • To study the thickness variation of volcanic rocks of Jeju Island, microtremor data were recorded at eight and four sites using short-period and broadband seismometers, respectively, for 30 ~ 60 minutes with a 100 Hz sampling rate. During the daytime, these records show increased cultural noise at frequencies above 1.8 Hz. Natural noise occurs in the frequency range of 0.4 to 0.8 Hz in both daytime and nighttime data. Predominant frequencies determined by the H/V spectral-ratio method are in the range of 0.2 ~ 0.7 Hz. These frequencies decrease gradually as the central part of the Mt. Halla is approached. This may indicate that the basement is warped downward beneath the center of the island, which is consistent with previous gravimetric and magnetic models. Assuming an average shear-wave velocity of 1,800 m/s for the overburden basalts, the depths to basement are estimated to be between 640 and 2,140 m.